Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance BHARSALA PARA NABAPALLY P O P S RAMPURHAT DIST BIRBHUM WB PIN 731224 | RAMPURHAT | BIRBHUM | WEST BENGAL | 731224 | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance 6 VANARAI SHOPPING COMPLEX W E HIGHWAY GOREGAON E MUMBAI 400065 | MUMBAI SUBURBAN | MAHARASHTRA | 400065 | Admitted-Finance |
| 5 | Admitted-Finance 201 ASHRAM AVENUE BEHIND KOCHRAB ASHRAM KOCHRAB VILLAGE PALDI AHMEDABAD GUJARAT 380006 | AHMADABAD | GUJARAT | 380006 | Admitted-Finance |
Tender Value
₹80.8 L
EMD Value
₹1.6 L
Closing Date
30 Jun 2025, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Project Director, INRPC,NRB,BARC Tarapur
Project Director office, INRPC, NRB, BARC, Tarapur, Maharashtra(401502)
Electrification Jobs of Block No-110 at INRP Site, Tarapur
2025_NRB_863251_1
BARC(T)/NRB/INRPC/ELE-61/2025/ 890
Open Tender
Electrical Works
Item Rate
180 days
INRP Site, BARC Tarapur
As per NIT
8 documents required · 8 mandatory
₹0
₹1.6 L
Meeting Room,Project Director office, INRPC
31 Jul 2025
7 Jun 2025
1 Jul 2025
7 Jun 2025
30 Jun 2025
17 Jun 2025
7 Jun 2025 - 15 Jun 2025
16 Jun 2025
Amount
Supply, Installation, Testing and Commissioning of following configuration 415V, 3-phase, 4 wire, double door, with R Y B Phase indication and MCB position indication through glass front, IP-54, Prewired with HFFR copper wires, horizontal type, metallic Double Door, Phase Segregated three pole and neutral MCB Distribution Board fabricated out of 2 mm thick ,powder coated with RAL7035 shade, pre-galvanised G.I. sheet steel, suitable for surface mounting complete with appropriate rating of tinned copper bus bar (fork type), neutral bus bar, earth bar, din bar, brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes, neoprene gasket, etc. as per drawing, specifications & generally as per relevant IS & as per instructions of Engineer-in-charge.
6 way having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 1 no. 25A, Isc=10kA, DP, MCB and RCCB(100mA) as incomer for each phase and 18 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type "C" curve, 10 kA breaking capacity and as per tender technical specifications.
Supply
Installation, Testing and Commissioning
4 way having 1 no. main incomer of 25A TPN MCB, Isc=10kA, Type C with 1 no. 25A, Isc=10kA, DP, MCB and RCCB(100mA) as incomer for each phase and 12 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type "C" curve, 10 kA breaking capacity and as per tender technical specifications.
Supply
Installation, Testing and Commissioning
Supply, Installation, Testing and Commissioning of following configuration 240V, 1-phase, 2 wire, with Phase and MCB position indication through glass front, Pre-wired with HFFR copper wires, IP-54, MCB Distribution Board fabricated out of 2mm thick Pre Galvanised G. I sheet steel, powder coated with RAL7035 shade, suitable for surface mounting complete with appropriate rating of tinned copper bus bar/Cu Wire, neutral bus bar, brass neutral link, brass earthing studs, phase distribution drawing, danger board, name plate, earth bar, din bar for MCB mounting, 2 mm thick removable gland plate on both top and bottom side with required number of knock out holes, neoprene gasket, check-nuts etc. as required as per tender technical specifications.
8 way having 1 no. main incomer of 40A DP MCB and RCCB(100mA), Isc=10kA, Type C and 8 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type "C" curve, 10 kA breaking capacity and as per tender technical specifications.
Supply
Installation, Testing and Commissioning
8 way having 1 no. main incomer of 25A DP MCB and RCCB(100mA), Isc=10kA, Type C and 8 nos. outgoing of 16A SPN MCB. suitable for 240V rating, Type "C" curve, 10 kA breaking capacity and as per tender technical specifications.
Supply
Installation, Testing and Commissioning
6 way having 1 no. main incomer of 16A DP MCB and RCCB(100mA), Isc=10kA, Type C and 6 nos. outgoing of 6A SPN MCB. suitable for 240V rating, Type "C" curve, 10 kA breaking capacity and as per tender technical specifications.
Supply
Installation, Testing and Commissioning
6 way having 1 no. main incomer of 16A DP MCB and RCCB(100mA), Isc=10kA, Type C and 6 nos. outgoing of 6A DP MCB. suitable for 240V rating, Type "C" curve, 10 kA breaking capacity and as per tender technical specifications.
Supply
Installation, Testing and Commissioning
4 way having 1 no. main incomer of 16A DP MCB and RCCB(100mA), Isc=10kA, Type C and 4 nos. outgoing of 6A DP MCB. suitable for 240V rating, Type "C" curve, 10 kA breaking capacity and as per tender technical specifications.
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, Industrial box type (approx. dim.130mm x 95mm x 1219mm), surface mounted 4ft fixture along with two nos. of 18W, 2340 lm, minimum 130 lm/w system efficacy, CCT 6500K and CRI>80, THD<10%, PF>0.95, 4ft LED tube. The luminaire shall meet IP20 rating. The LED shall be mounted on extruded aluminium box which acts as heat sink with extruded poly carbonate material which gives diffused light. The total power consumption should not exceed 38W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation and Testing
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED 4ft Industrial Batten (approx. dim. 75mm x 95mm x 1219mm) with a nominal system lumen output of 2500 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 6500K and CRI>80. The luminaire shall meet IP20 rating with THD < 10% and PF > 0.95. The luminaire housing should have made of Extruded Aluminium with extruded PC diffuser. The total power consumption should not exceed 20W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation and Testing
4ft Industrial Batten (approx. dim.140mm x 105mm x 1219mm) with 2x18W LED Tube (acid & corrosion proof) with a nominal system lumen output of 4320 lumens and a minimum system efficacy not less than 120lm/W. The luminaire should have a colour temperature of 6500K and CRI>80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should have made of • Body - glass reinforced polyester (GRP), RAL 7035 • Gasket - polyurethane • Diffuser - UV stabilised prismatic acrylic material. The total power consumption should not exceed 38W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation and Testing
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED Bulkhead with a nominal system lumen output of 1200 lumens and a minimum system efficacy of 120 lm/W. The luminaire should have a CCT of 6500K and CRI > 80. The luminaire shall meet IP65 rating with THD < 10% and PF > 0.95. The luminaire housing should have made of High pressure die cast Aluminium with high quality PMMA diffuser. The total power consumption should not exceed 10W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED peripheral luminaire with a nominal system lumen output of 4200 lumens and a minimum system efficacy of not less than 120 lumens/watt. The luminaire should have CCT of 5700K and a CRI>70. The luminaire shall meet IP66, IK 07 rating with THD<10% & Pf>0.95. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 35W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED High-bay with a nominal system lumen output of 18000 lumens and a minimum system efficacy of not less than 140 lm/W. The luminaire shall have a rated system lifetime of 50,000 burning hours at L70B50. The luminaire should have a CCT of 5700K and CRI > 80 and SDCM<5. The luminaire shall meet IP66 and IK 08 rating with THD < 10% and PF > 0.95 and in-built surge protection of 4kV. The luminaire housing should have made of High Pressure die cast Aluminium with wide beam optics and having gasket of heat proof silicone rubber ring. The total power consumption should not exceed 130W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED integral driver flood light with a nominal system lumen output of 16,800 lumens and a minimum system efficacy of 140 lumens/watt. The luminaire shall have rated system lifetime of 50,000 burning hours at L70B50.The luminaire should have a CCT of 5700K and a CRI>70. The luminaire shall meet IP66 rating with THD<10% & Pf>0.95. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 120W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED Recessed 2ft x 2ft Luminaire with a nominal system lumen output of at least 4000 lumens and a minimum system efficacy of 125 lm/W. The luminaire should have a CCT of 5700K and CRI>80. The luminaire shall meet IP20 rating with THD<5% and PF >0.95, UGR<16% & SDCM <= 4. The luminaire housing should have made of powder coated metallic CRCA with high efficiency optic diffuser. The total power consumption should not exceed 36W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED integral driver flood light (acid & corrosion proof) with a nominal system lumen output of 5000 lumens and a minimum system efficacy of 140 lumens/watt. The luminaire should have CCT of 6500K and a CRI>80. The luminaire shall meet IP66 rating with THD<10% & Pf>0.95 The luminaire housing should be made of Stainless steel. The total power consumption should not exceed 36W (including BIS Compliant integrated driver) and other requirements shall be as per tender technical specifications.
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including supply of fixing SS accessories, flexible GI metallic conduit sleeves, PVC conduit bushes, Cu cable lugs, suitable PVC terminal box, LED integral driver flood light with a nominal system lumen output of 10,000 lumens and a minimum system efficacy of 140 lumen/watt. The luminaire should have CCT of 6500K and a CRI>80. The luminaire shall meet IP66 rating with THD<10% & Pf>0.95. The luminaire housing should be made of pressure die cast aluminium. The total power consumption should not exceed 72W (including driver).
Supply
Installation, Testing and Commissioning
SITC of LED light fittings complete with light fitting accessories, including accessories, flexible GI conduit sleeves, PVC conduit bushes, Cu cable lugs, LED Down lighter with a nominal system lumen output of 2400 lumens and a minimum system efficacy of 130 lm/W. The luminaire should have a CCT of 5700K and CRI > 80. The luminaire shall meet IP20 rating and IK06 rating, Lifetime (L70/B50): 50,000 h with THD < 10% and PF > 0.9. The luminaire housing should have made of High pressure die cast Aluminium with high quality Polycarbonate diffuser. The total power consumption should not exceed 19W (including BIS Compliant integrated driver). Approx. dimensions of down lighter shall be 250 dia and 75 height in mm and other parameters as per tender technical specifications.
Supply
Installation, Testing and Commissioning
1 no. of 6A and 1 no of 16A, Single phase Industrial three pin Socket with corresponding Type C-Curve, Industrial type MCBs, Isc=10kA, along with pre- powder coated GI sheet steel Face Plate, Industrial Plug Tops and suitable DIN rail and mounting arrangements as per technical specification.
Supply
Installation in existing embedded GI Box
Pre-Galvanised sheet steel Distribution box with 1 no. of 6A and 1 no. of 16A, Single phase Industrial three pin Socket along with Industrial Plug Tops with corresponding Type C-Curve, Industrial type MCBs, Isc=10kA,mounted on suitable DIN rail and as per technical specifications
Supply
Installation on concrete/brick wall
1 no. of 16A, Single phase Industrial three pin Socket with corresponding Type C-Curve, Industrial type MCB, Isc=10kA, along with pre- powder coated GI sheet steel Face Plate, Industrial Plug Tops and suitable DIN rail and mounting arrangements as per technical specification.
Supply
Installation in existing embedded GI Box
Pre-Galvanised sheet steel Distribution box with 1 no. of 16A, Single phase Industrial three pin Socket along with Industrial Plug Top with corresponding Type C-Curve, Industrial type MCB, Isc=10kA, mounted on suitable DIN rail and as per technical specifications
Supply
Installation on concrete/brick wall
1 no. of 6A, Single phase Industrial three pin Socket with corresponding Type C-Curve, Industrial type MCB, Isc=10kA, along with pre- powder coated GI sheet steel Face Plate, Industrial Plug Tops and suitable DIN rail and mounting arrangements as per technical specification.
Supply
Installation in existing embedded GI Box
Pre-Galvanised sheet steel Distribution box with 1 no. of 6A, Single phase Industrial three pin Socket along with Industrial Plug Top with corresponding Type C-Curve, Industrial type MCB, Isc=10kA, mounted on suitable DIN rail and as per technical specifications
Supply
Installation on concrete/brick wall
1 nos. of 6A, Single Pole, Isc=10kA, Type C-Curve, MCB along with pre- Galvanised sheet steel Face Plate and suitable DIN rail and mounting arrangements as per technical specification.
Supply
Installation in existing embedded GI Box
Pre-Galvanished sheet steel Distribution box with 1 no. of 6A Single Pole, Isc=10kA, Type C-Curve, MCB, mounted on suitable DIN rail and as per technical specifications
Supply
Installation on concrete/brick wall
2 nos. of 6A, Single Pole, Isc=10kA, Type C-Curve, MCB along with pre- Galvanised sheet steel Face Plate and suitable DIN rail and mounting arrangements as per technical specification.
Supply
Installation in existing embedded GI Box
Pre-Galvanished sheet steel Distribution box with 2 nos. of 6A Single Pole, Isc=10kA, Type C-Curve, MCB, mounted on suitable DIN rail and as per technical specifications
Supply
Installation on concrete/brick wall
3 nos. of 6A, Single Pole, Isc=10kA, Type C-Curve, MCB along with pre- Galvanised sheet steel Face Plate and suitable DIN rail and mounting arrangements as per technical specification.
Supply
Installation in existing embedded GI Box
Pre-Galvanished sheet steel Distribution box with 3 nos. of 6A Single Pole, Isc=10kA, Type C-Curve, MCB, mounted on suitable DIN rail and as per technical specifications
Supply
Installation on concrete/brick wall
Pre-Galvanised sheet steel Distribution box with 1 no. of 6A, Single phase Industrial three pin Socket along with Industrial Plug Top, and as per technical specifications
Supply
Installation on concrete/brick wall
1no. of 6A, Single phase Modular Decorative Type Switch with heavy duty polycarbonate Box, Face Plate and suitable mounting arrangements as per technical specification.
Supply
Installation on concrete/brick wall
2 nos. of 16A, Single phase Modular Decorative Type three pin Socket with Polycarbonate box, accordingly rated Switches for each Socket and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification.
Supply
Installation on concrete/brick wall
3nos. of 16A, Single phase Modular Decorative Type three pin Socket with Polycarbonate box, accordingly rated Switches for each Socket and heavy duty polycarbonate Face Plate, plug tops and suitable mounting arrangements as per technical specification.
Supply
Installation on concrete/brick wall
Occupancy Sensor with 3 way switch
Supply
Installation and Testing
Supply and fixing of heavy duty Class-B Galvanised steel (G.I.) ERW 25mm conduit pipe of following sizes along with all accessories such as bends, junction box, socket, check nut, etc. including making threads, removing burrs, connection of accessories, cleating with heavy duty GI saddles or suit to site clamps on RCC wall, column, steel structural, etc. as required under the instruction of Engineer-in-incharge. Surface type junction box shall be provided.
Supply
Installation
Supply and laying of 14 SWG tinned solid copper conductor throughout along the conduit including fixing with hose clips, lugs, brazing etc as required.
Supply
Installation
Supply of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100 V as per the IS 17048: 2018 (latest edition) and as per conductor class 2 of IS: 8130 / 1984 as per technical specification
Installation/drawing through concealled/ surface conduit and wiring and termination at both ends of Single Core HFFR wires (Copper) of size mentioned below in voltage grade 1100 V as per the IS 17048 : 2018. As per conductor class 2 of IS: 8130 / 1984 as per technical specification
Supply and laying of 10 sq. mm tinned copper conductor, connection with earth pad at one end and DBs at other end clamping, brazing etc. and as tender technical specifications.
Supply
Laying of conductor after chasing floor or wall and finishing the same.
Supply and installation of test link box for earth pit connection and interconnection of down conductor from lightning protection system to lightning earth pit and should consist of 2mm thick powder coated pre-galvanised G.I. weather proof sheet enclosure with cover, having 2 parallel paths of 50 mm x 3mm copper strip link, teflon sealing after connection, earthing stud, suitable for connecting of 8 nos. of 95sqmm earthing conductors etc as required.
Supply
Installation of test link box on wall and termination of earthing conductor using lugs
Supply and Installation of 25 mm X 3 mm thick copper strip including connection/ terminating with brass nut, bolt, washer etc. as required.
Supply
Installation, Testing
Supply and fixing vertical air termination made up of 20mm dia, 1 mtr long copper rod attached to 145 mm dia. Copper sphere having drilled and tapped holes for fixing 5 nos. of 390mm long spikes and square copper base plate of 150 mm length and 10 mm thickness as per technical specification and approved drawing.
Supply
Installation and Testing
Supply of tinned Cu Lugs , ring type, of following sizes as per attached technical specification
95sqmm stranded bare tinned copper conductor
10sqmm stranded bare tinned copper conductor
Supply of required material and making of straight exothermic braze joints of copper conductors (95 sqmm) as per technical specification.
Supply of required material and making of 'T' type exothermic braze joints of copper conductors (95 sqmm) as per technical specification.
Supply and Installation of 2mm thick pre-galvanished GI sheet including marking,cutting (as per site requirement)and erection on top of JB openings on wall and ceiling at approximate height of 5mtrs.
Supply
Installation
National Construction (BID ID -3239942)
POZITRON ENGINEERING SYSTEMS (BID ID -3240219)
Moon Light (BID ID -3240127)
SARASWAT ENGINEERING SERVICES (BID ID -3240854)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .