| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.9 LAccepted-AOC SHIV BARI ROAD NEAR KASUMAL HOTEL BIKANER 334003 RAJASTHAN | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC Lowest and reasonable bidder | |
| 2 | L2₹4.9 L+₹55,732 (12.8%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder. | |
| 3 | L3₹5.2 L+₹80,377 (18.4%)Rejected-Finance BEHIND POWER HOUSE WARD NO 6 UDASAR BIKANER RAJASTHAN 334022 | BIKANER | RAJASTHAN | 334022 | L3 | Rejected-Finance Other than lowest bidder. |
Tender Value
₹5 L
EMD Value
₹10,000
Closing Date
23 Jul 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF NAL
GE AF NAL
AS DESCRIBED IN BILL OF QUANTITIES
2024_MES_661430_1
GE (AF) NAL/T-15/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
183 days
GE AF NAL
AS PER NIT AND TENDER DOCUMENTS
8 documents required · 8 mandatory
₹300
GE AF NAL
₹10,000
Yes
13 Sept 2024
26 Jun 2024
25 Jul 2024
26 Jun 2024
23 Jul 2024
10 Jul 2024
26 Jun 2024 - 5 Jul 2024
Amount
Dismantling/taking down old unserviceable ACSR conductor of any size from LT / HTpoles over head electric line after disconnecting from insulators complete all as specified and directed.
Supplying and Fixing Aluminium conductor, steel reinforced (ACSR) of any size, straining properly on insulators and binding on existing LT / HT poles or new poles with and incl 02mm dia aluminium binding wire all as specified & directed. Make of ACSR : ICC/ NICCO/ BHARAT CONDUCTORS. Note : The 3% for sag, joints & jumpers shall be added in measurements.
Re-stretching the existing LT/HT over head line consisting of 5/4/3 conductors of any size and one GI wire after removing serviceable/unserviceable separators carefully including opening and reconnecting of jumpers binding conductor over the insulator properly with the help of binding wire 14 SWG and re-fixing separators in its original position complete all as specified and directed by Engineer-in-charge Note : 1. The cost of binding wire is deemed to be included in quoted rates. 2. The distance between two poles for single HT conductor/earth wire will be consider as one span.
Taking down of old rusted GI wire of any description / size from HT Poles of any size, complete all as specified & directed.
Supply and fixing contineous GI earth wire/gaurd/cradles of 4mm dia including GI binding wire 1.63 mm and GI holding hook on HT poles, complete all as specified and directed.
Taking down / dismantling of old unserviceable insulators any type from cross arms / pole of any size, complete all as specified & directed.
S&F pin type porcelain vitreous white or brown insulator incl one galvanised MS spindle, two washers and one galvanised iron nut, 150mm height, 150mm dia for 11000 volts grade fixed on poles/cross arms of upto 11 m long complete all as specified.
Supply and fixing Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green with tension clamps for conductors, working pressure 11 Kv complete all as specified and directed.
Dismantling old stay assembly complete incl demolition of cement concrete and removing drbris outside MOD Land, complete all as specified and directed. Note : (i) Unit rate of this item includes the loose/disconnect the all accessories which are connected to stay assy includng necessary excavation as directed. (ii) Existing stay assy are fixed on the LT/HT pole of PCC or steel tubular pole, nothing extra shall be paid on this account.
Material and Labour for Stay assembly complete with accessories as shown in electrical plate No 1 including GI Adjustable Stay Rod of 18 mm Dia, GI Stay wire of size 7/4 mm incl stay clamps, loop type insulator, including excavation in soft/ loose soil including providing PCC 1:3:6 concrete all as specified and directed. Note:- Unit rate of this item includes the cost of earthwork, loop type insulator, PCC and stay wire.
Dismantling of cross arms, supports, clamps and back plates incl nut bolts washers, any shape or size as indicated complete all as directed. Note :- (i) Existing MS work is of different sizes and fixed at different locations. While dismantling, ACSR conductor shall be loosened properly as per direction of Engr-in-Charge (ii) T & P required for dismantling shall be arranged by the contractor at his own cost.
M & L for mild steel works in Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and as directed.
Supply and fixing in repair Lightning Arresters expulsion type complete with all fittings , transmission class , discharge capacity 65 kilo Amp, 11000 Volts, complete all as specified and as directed.
Taking down air break gang operated switch vertical / horizontal mounted including insulators and operating mechanism / replacement of old unserviceable air break switches of 400 Amps complete all as specified and directed.
Supply & fixing 11 KV 3 Phase Gang operated air break switch 400 amp capacity, horizontal type complete with locking arrangement and fixing the gang operated switch on existing two/four pole structure including making all jumper connections with insulated leads of suitable size with line tops etc, all as specifed and directed.
Material and labour for galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick, buried directly in ground, vertically to a depth not less than 2.25 mtr deep below ground level with top edge of the earth plate at depth not less than 1.5 mtr below ground level earth plate surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, earth lead GI strip 32mmx6mm by means of bolts, nuts, check-nuts and washers of galvanized iron and thimbles and of earth wire protected by galvanized iron pipe light grade 40mm bore and water pipe 20 mm bore GI medium grade with funnel and wire mesh complete including excavation and earth work, PCC chamber and cover in cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregate in lieu of CI cover and frame etc all as specified and shown in electrical plate No. 3 of SSR-2009 (Part-I) and taking out exhisting old unservciable earthing, complete all as specified and as directed.
Disconnecting the HT 11 KV supply from VCB SF 6 unit , removing the top cover of VCB for carrying out complete servicing of incoming and outgoing feeders (one incoming feeders and two outgoing feeders) completely by air blower and removing the dust deposited over all mechanical parts, oiling, greasing the mechanical moving parts and replacement of worn out parts cumuliative costing upto Rs 2000 and testing the VCB for smooth operations, Caliberation of IDMT relays, for over current and earth fault and resetting the same as per load on the feeders, complete all as directed. Note :- Servicing and calibration of VCB shall be done by authorised service provider of OEM i.e. ABB.
M&L in repairs 40mm thickness, 2nd class hardwood planks, n exc. 25 cm in width and fixing on angle iron frame of 2/4 pole structure, screwing with existing iron structure complete suitable length laying adjust one by one including one coat of paint over a coat of pink primer complete all as specified. Note : Width and length of plank shall be as per existing / as directed.
Trimming of tree branches on both sides of LT aluminium conductor overhead complete all as specified and directed. Note :- (i) Lenth of Overhead electric line covered by the tree branches shall only be considered for payment and shall be be jointly assesed before cutting tree branch. (ii) Cut branches shall be dumped inside the air force premises as directed by engg-in-charge. (iii) Contractor shall arrange the ladder of required size including T&P for cutting branched and necessary saftey equipments to his worker and nothing extra shall be paid on this account.
Dismantling of damaged PCC/steel tubular pole of size 11 mtr for disposal all as specified and as directed. Note:- Unit rate of this item includes the cost of dismantling of PCC and excavation and earthwork complete as directed.
Supply, installation and erection in true vertical position steel tubular swaged welded poles complete with MS base plate of 6 mm thick of size 300mm x 300mm, finial taper plug, pole cap, bolts, nuts and washers and screwed, pole made out of ERW MS tubing conforming to IS-2713 ( Part II),1980 type 410-SP-44, 11 meters long H.T. pole including drilling of holes of required size and Nos for fixing of cross arms, painting with one coat of red oxide primer and two coats of aluminium paint for exposed surfaces and two coats of black bituminous paint for portion embeded in concrete, painting with two coats of aluminium paint over a coat of primer including excavation incl PCC complete in post hole in any type of strata, PCC 1:2:4 foundation, filling, in post holes with PCC 1:3:6 and cylinderical coping with PCC 1:2:4 of size 0.45x.3 complete all as specified and directed.
Taking out existing unserviceable XLPE insulated armoured, heavy duty, electric cable with aluminium conductors 11000 volts of any size laid in trenches, ducts along the walls, through pipes, under road, pole etc. complete all as specified and directed.
Taking out old unserviceable/serviceable un-reinforced concrete PCC cable covers from excavated trench all as directed.
Excavation in trenches in soft/loose soil not exceeding 1.5 mtr wide and not exceeding 1.5m deep, getting out the excavated earth, forming bottom surfaces to required gradient complete all as specified and directed.
Removal of excavated material / soils to a distance n exc 50m and depositing where directed at a level not exceeding 1.5m above the straight point complete all as specified and directed.
Returning filling in, including spreading, levelling watering and well ramming in layers n exc 25 cm in soft / loose soil complete all as specified and directed.
M&L sand cushioning using dry and clean tibba sand in two layers, first layers of 80mm thick before laying of cable and second layer of 150mm thick after laying of cable in trenches/ducts including consolidation of each layers (overall thickness after consolidation should be 180 mm complete all as specified and directed.
Material and labour for fixing of new un-reinforced pre-cast concrete cable covers, class HV, Type 1, flat, size 300mmx 180mm x 40mm complete all as specified and as directed.
Supply and Laying XLPE insulated armoured of size 120 Sqmm 3 Core, heavy duty, electric cable with aluminium conductors 11000 volts laid in floors, ducts, pipes drawn across the road/paths/drain/along poles/walls/floor/equivalent etc including jointing & testing complete all as specified and as directed.
Supplying and fixing Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, complete all as specified and as directed.
M/S BIKANER CHEMICAL LABORATORIES (BID ID -3072267)
BIDAWAT ENTERPRISES (BID ID -3072457)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .