Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.3 CrAccepted-AOC | ₹14.3 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹14.3 CrRejected-Finance | ₹14.3 Cr | L2 | Rejected-Finance L2 |
| 3 | L3₹14.5 CrRejected-Finance | ₹14.5 Cr | L3 | Rejected-Finance L3 |
Tender Value
₹12.6 Cr
EMD Value
₹25.3 L
Closing Date
22 Jan 2020, 2:00 pmClosed
SE-MPHC Ltd.,Imphal.
Old 6th M.R Complex, Imphal.
Establishment of Infectious Disease at JNIMS, Porompat, Imphal East in Manipur under NESIDS.
2020_MPHCL_767_1
No. e-Tender 03/SE/MPHC/2019-20/332
Open Tender
Civil Works - Buildings
365 days
As Per Tender Document.
Please refer Tender documents.
11 documents required · 11 mandatory
₹1,500
MD, MPHC Ltd, Imphal.
₹25.3 L
29 Aug 2020
9 Jan 2020
22 Jan 2020
10 Jan 2020
22 Jan 2020
11 Jan 2020
11 Jan 2020 - 21 Jan 2020
Amount
(SH:- A) Civil Component - Main Building - (G+2 ) RCC framed structure.)
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
Providing, laying naturally occurred sand gravel -III free from organic or other deleterious constituants including watering ramming,consolidating in layers not exceeding 150mm (Spread thickness)and dressing etc. complete as directed by the Engineer-in-charge
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) 1:5:10 (1 cement :5 Kanhaighat sand :10 graded stone aggrt. 40mm nominal size).
(c) 1:2:4 (1 cement :2 Kanhaighat coarse sand :4 graded stone aggrt. 20mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(b) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply) ( a) Foundation footings, bases of columns etc. and mass concrete.
(b) Columns, pillars, posts and struts (square, rectangular or polygon in plan).
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(d)Flat surface such as suspended flloor,roofs, landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floor not exceeding 1m in depth
(f) Staircase (e/c landing) slopping or stepped soffits i/c riser and strings etc.
(g) Vertical surface such as walls (any thickness), partition and the like including attached pilasters, buttreese, plinth and the string courses and the like
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 Cem: 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure. (a) Above plinth level upto 1st floor level.
(b) Above 1st floor level upto 2nd floor level
(c) Above 2nd floor level upto 3rd floor level
WOOD WORK
Providing wood work in frames of doors, windows, clerestory windows and other frames wrought framed and fixed in position a) Local best quality Teak wood
Providing and fixing 38 mm thick panalled,glazed or panelled and glazed shutters fordoors,windows, c/windows etcincluding bright finished brass hinges with necessary screws.(a)Local best quality Teak wood.
Providing 40x3mm flat iron hold fast 40cm long i/c fixing to frames with 10mm dia bolts, nuts and wooden plugs and embedding to cement concrete block 30x10x15cm 1:3:6 (1 cement : kanhaighat coarse sand : 6 stone aggrt. 20mm nominal guage).
Providing and fixing aluminium hanging floor door stopper,ISI marked,anodised (anodic coating not less than grade AC 10 as per IS :1868 ) transparent or dyed to required colour and shade,with necessary screws etc. complete. (b) Twin rubber stopper
Providing and fixing Brass sliding bolts bright finished or black enamelled with nuts & screws etc. complete. A) 300 x 16 mm
Providing & fixing Brass Tower bolts (barrel type) with screws etc. complete. (a) 250x10 mm
Providing & fixing Brass handles with necessary screws etc. complete.(a) 125mm
Mild STEEL WORKS & STAINLESS STEEL WORKS
Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge.
Providing & fixing in position collapsible steel shutters with vertical channels 20 mm X 10 mm X 2 mm & braced with flat iron diagonals 20 mm X 5 mm sizes with top & bottom rails of T iron 40 mm X 40 mm X 6 mm with 38 mm dia steel pullets complete with bolts & nuts, looking arrangement, stoppers, handles i/c applying a priming coat of red lead paint.
FLOORING
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by manufacturer ), with water absorption less than 0.08 % and conforming to IS : 15622, of approved make , in all colours & shade ,in laid on 20 mm thick cement mortar 1:4 ( 1 cem : 4 Kanhaighat coarse sand ) , i/c grouting the joints with white cement and matching pigments etc complete.1.1) Size of tile 600x600 mm (Single charged) Branded
Providing and laying vitrified tiles in different sizes (thickness to be specified by manufacturer ), with water absorption less than 0.08 % and conforming to IS : 15622, of approved brand and manufacturer , in all colours & shade ,in skirting , riser of steps,over 12 mm thick bed of cement mortar 1:3( 1 cement: 3 Kanhaighat coarse sand),including grouting the joint with white cement & matching pigmnets etc.complete. 1.1) Size of tile 600x600 mm (Single charged) Branded
Granite stone slab flooring over 20 mm (average) thick base of cement mortar 1 : 6 (1 Cement: 6 kanhaighat coarse sand ) laid and jointed with grey cement slurry including rubbing and polishing complete with -(a) Granite slab 20 mm slab thick (i)Jade Black 60 x 120 cm
ALUMINIUM WINDOWS
Providing and fixing glazing in aluminium door,window, ventilator,shutters and partition etc. with EPDM Rubber Neoprene gasket etc complete with float glass paints of 4 mm thick with frames of aluminium hollow tube of 50 x 50 mm and angle of 25 x 40 mm fastened with stainless steel screws, nuts bolts washers cleats weather silicon sealant backer rods etc
Providing and fixing anodised aluminium grill of approved design/pattern,with approved standard section and fixed to the existing window frame with C.P. brass / stainless steel screws @200 mm centre to centre, including cutting the grill to proper openings size for fixing and operation of handles and fixing approved anodisied aluminium standard section around the opening, all complete as per requirement and direction of Engineer- in charge.
FINISHING
12mm cement plaster 1:4 (1 cement : 4 kanhaighat coarse sand).
15mm cement plaster 1:4 (1 cement : 4 Kanaighat coarse sand).
15 mm cement plaster 1:3(1 cement:3 Kanhaighat coarse sand)finished with a floating coat of neat cement.
Painting (two or more coats excluding priming coat) with superior ready mixed paint for steel work of approved quality in all shades on new steel work to give an even shade.
Applying ready mixed priming coat pink primer of appd. quality on wood work.
Painting two or more coats (excluding priming coat) with superior ready mixed paint for wood work of appd. quality in all shades on new work to give an even shade
Providing and applying white cement base putty of 2mm thickness over plastered surface to prepare the surface even and smooth complete.
Painting on wall with (two coats) of plastic emulsion paint of approved quality in all shades on new work to give an even shade.
Applying one coat of cement primer of approved quality on wall surface.
Finishing wall weather shield paint of approved quality on new work (three or more coats) to give an even shade.
Making khurras 450 mm x450 mm with 50 mm thick cement concrete 1:3:6 (1Cem : 3 kanhaighat coarse sand :6 hard ballast 19 mm & down gauge) finished with 12 mm cement plaster 1:3 ( 1 Cem : 3 kanhaighat coarse sand ) with a coat of neat cement rounding the edges & making good & finishing the outlet complete.
Providing & fixing on wall face G.I. rain water pipe i/c filling the joints with spun yarn soaked in neat cement slurry & cement mortar 1:2 (1 cement : 2 fine sand) a) 150 mm diameter.
Providing & fixing M.S. holder bat clamps embedded in & i/c cement concrete blocks 112.5 mm X 112.5 mm of 1:2:4 mix (1 cement:2 coarse sand:4 hard stone bollast 20 mm & down gauge). a) 150 mm diameter.
Providing & fixing on walls face G.I. head for rain water pipe i/c filling the joints spun yarn soaked in neat cement slurry & cement mortar 1:2(1 cement:2 fine sand). a) 150 mm diameter.
Supplying and applying Dr. Fixit primeseal (after making dilution with water in the ratio 2:1 ( 2 primesial : 1 water ) on new roof at 1 litre per 9.3 sqm after cleaning the surface using wire brush or approprite tools (surface to be washer off with water)and allow drying of 2 -3hours before applying Dr. Fixit New coat over this coat as per direction of the Engineer - in -charge.
Supplying and applying Dr. Fixit New coat on primeseal roof surface in three different coats at 1 litre per 1.95 sqm . per coat laying fibre mesh with adhesive primer ( consuning 20 litre for 80 sheet of 3 x 10 m fibre mesh ) after 1 st coat of new coat 2nd coat of newcoat should be applied immediately after laying of fibre mesh 3rd coat of Dr. Fixit newcoat should be applied after allowing drying of the 2nd coat for 6 to 8 hrs. Each coat should be applied in perpendicular direction to the underlaying layer. the entire process should be carried out under strict supervision and direction of the Engineer - in -charge.
Boring ,providing and installation bored cast-in-situ reinforced cement underreamed pile of specified diameter and length below the pile cap M 25 with one under reamer (two and half time the bore dia.) in cement concrete, to carry a safe working load not less than specified ,excluding the cost of steel reinforcement but including the cost of boring with catching and / or bentonite solution and the length of pile to be embeded in the pile cap etc. all completed (Length of the pile for payment shall be measured up to top of pile cap i/c dismantling of cast pile for 0.85 m at the top ).i) 500 mm diameter pile for 18.85 metre.
Boring ,providing and installation bored cast-in-situ reinforced cement pile of specified diameter and length below the pile cap M 25 with in cement concrete, to carry a safe working load not less than specified ,excluding the cost of steel reinforcement but including the cost of boring with catching and / or bentonite solution and the length of pile to be embeded in the pile cap etc. all completed (Length of the pile for payment shall be measured up to top of pile cap i/c dismantling of cast pile for 0.85 m at the top ).i) 500 mm diameter pile for 18.85 metre.
Conducting Pile load test as per IS 2911 Pt-IV for calculation of safe load capacity of pile i/c mobilisation and demobilisation of all requisite machineries and equipments along with submission of reports etc. complete as per direction of the Engineer - in-charge
Providing of water supply and sanitary installations (W.S. & S.I.)
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a) 1:5:10(1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).
(b) 1:3:6 (1 cem :3 Kanhaighat Coarse sand:6 graded stone aggrt.40mm n/size).
(c) 1:2:4 (1 cement :2 Kanhaighat coarse sand :4 graded stone aggrt. 20mm nominal size).
REINFORCED CEMENT CONCRETE WORK
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : (a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. up to floor five level,excluding cost of centering, shuttering, finishing and reinforcement :(a)1:1:2 (1 cement :1 Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1:2 (1 cement :1Kanhaighat coarse sand:2 graded stone aggregate 20 mm nominal size.)
Steel reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete.(b) Thermo-Mechanically Treated bars.
FORMWORK
Providing form work i/c centering & shuttering so as to give a rough finish strutting and propping etc. height of propping and centering below supporting floor to ceiling not exceeding 4m and removal of the same for insitu reinforced concrete to and plain concrete work in.(using 12mm shuttering ply) ( a) Foundation footings, bases of columns etc. and mass concrete.
(c) Sides and soffits of beams, beam haunchings, cantilivers, girders, bressumers and lintels not exceeding 1m in depth.
(d)Flat surface such as suspended flloor,roofs, landing & the like ( i) floor etc upto 200mm in thickness
(e)Edges of slab and breaks in floor not exceeding 1m in depth
(g) Vertical surface such as walls (any thickness), partition and the like including attached pilasters,
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 Cem: 4 Kanhaighat coarse sand)
Half brick masonry 2nd class (local first class) in cement mortar 1:4 (1 cement : 4 kanhaighat coarse sand) in superstructure.
15 mm cement plaster 1:3(1 cement:3kanhaighat coarse sand )finished with a floating coat of neat cement.
Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/ 8 litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required :a)Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern
Providing and fixing laboratory sink white glazed vitreous china (Indian make) with R.S. or C.I. brackets painted white a pair of 12.5 mm C.P. brass pillar tap 323 mm rubber plugs and C.P. brass chain 32 mm C.P. brass waist of standard pattern 32 mm diameter M.I./C.P. brass traps and unions complete i/c cutting and making good the walls Indian fittings. With overflow a) 530 x 430 x 180 mm
P / F kitchen sink white glazed vitreous china Indian make with RS or CI brackets painted white a pair of 12.5 mm CP brass pillar tap 323mm rubber plugs and CP brass chain 32mm CP brass waist of standard pattern 32 mm dia. MI/CP brass traps and unions complete i/c cutting and making good the walls Indian fittings.a) 610 x 450 x 250 mm
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required:White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P.
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing 600 x120 x 5 mm glass shelf (Indian make) with C.P. brass brackets guard nail complete fixed to wooden cleats with C.P. brass screws.
Providing and fixing 600 x 20 mm C.P. brass towel rail complete with C.P. brass brackets fixed to wooden cleats with C.P. brass screws (Hook type )
Providing and fixing liquid soap container of glass with C.P. lid and brackets fixed to wooden cleats with C.P. brass screws.
Providing and fixing HCI traps with 100 mm inlet and 50 mm outlet of self cleaning design with HCI screwed down of hinged grating with or without vent arm complete i/c cost of cutting and making good the walls and floors.
Providing and fixing brass bib cock of approved quality. 25 mm diameter (Swan neck left/right HN Delux)
Providing and fixing brass stop cock of approved quality.50 mm diameter
Providing and fixing brass full way G.M valve with CI wheel of approved quality.50 mm diameter
Providing and fixing C.P. brass shower rose with 12.5 mm or 19 mm inlet
Providing and fixing Water Storage Tanks with 400 mm diameter nominal base G.I. overflow tube 25 mm nominal G.I. inlet and 15 mm nominal G.I. outlet tube i/c hoisting a height of 10 m above ground level.2000 litres net capacity storage tanks
Providing and fixing 100 mm H.C.I. soil, waste & vent pipes.
Providing and fixing MS holder bat clamps of approved design to 100 mm HCI pipe socket i/c cost of cutting holes and making good the walls etc.
Providing and fixing 100 mm HCI heel rest bend
Providing and fixing 100 x 100 x 100 mm HCI branch of the required degree with access doors, insertion rubber washer 3 mm thick bolts and nuts complete.
Providing and fixing 100x100x100x100 mm HCI plain branch of the required degree.
Providing and fixing 100 mm HCI terminal guard.
Providing and fixing lead caulked joints to 100 mm HCI pipes
Painting of HCI soil waste vent pipes and fittings with paint of any colour such as chocolate, grey or buff etc. a coat of primer (of approved quality) on new work. a) 100 mm diameter
Providing and fixing 100 x 100 x 100 mm HCI plain branch of the required degree.
P/F C.I cover with frame for (manhole and chamber) (a) 600x450mm (Heavy duty)
Construction masonry chamber with 2nd class brick work (local first class) in cement mortar 1:5 (1 cement : 5 fine sand) for sluice valve with C.I. surface box 100 mm top diameter and 180 mm deep (inside) with chained lid and R.C.C. top slab 1:2:4 (1 cement : 2 course sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 course sand) finished with a floating coat of neat cement complete. i) 1200 x 1200 x 1000 mm
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. i) 25 mm nominal outer dia Pipes
ii) 32 mm nominal outer dia Pipes
Development works surrounding the building and its approach.
EARTH WORK
Earthwork in excavation foundation trenches or drains including dressing of sides and ramming of bottoms and including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 m. (a) Lift upto 1.5 m
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm.in depth, consolidating each deposited layer by ramming and watering lead upto 50 metres lift upto 1.5 metre.
CONCRETE WORK
Providing and laying cement concrete works in foundation and plinth excluding the cost of centering & shuttering in (a 1:5:10(1 cement :5 Kanhaighat coarse sand :10 graded stone aggrt. 40mm nominal size).)
(b) 1:3:6 (1 cem :3 Kanhaighat Coarse sand:6 graded stone aggrt.40mm n/size).
BRICK WORK
2nd class (local first class) brick work in foundation and plinth in cement mortar 1:4 (1 Cem: 4 Kanhaighat coarse sand)
15 mm cement plaster 1:3(1 cement:3kanhaighat coarse sand )finished with a floating coat of neat cement.
SH: B) Electrical Component i/c Fire fighting system and Elevator
Wiring
Wiring for light point/fan point/exhaust fan point/call bell point with 1.5mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with modular type switch and earthing the point with 1.5mm2 FR PVC insulated copper conductor single core cable etc.as reqd.
Group A
Group B
Group C
Wiring for light point/power plug with 2X4mm2 FR PVC insulated copper conductor single core cable in presto plast cassing and capping with 1 No. 4mm2 FR PVC insulated copper conductor single core cable for loop earthing etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
2X1.5mm2+1X1.5mm2 earth wire
2X2.5mm2+1X2.5mm2 earth wire
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
P/L 50mm2 4-core pvc ins.(heavy duty)Cu. cond. armoured cable of 1.IKV grade of size not exceedng 25mm2 but not exceeding 120 sqmm direct in ground i/c excavation,sand cushioning protective covering and refilling the trench etc.as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X16mm2+1X16mm2 earth wire
Supply and fixing (following modular type switch/socket) on the existing modular plate and switch box i/c connection but excluding modular plate etc as reqd.
5/6 amps switch
15/16 amps switch
3 pin 5/6 amps socket outlet
6 pin 15/16 amps socket outlet
Fitting Accessories
S/F brass batten/angle holder i/c connection etc.as reqd.
S/F 12W LED bulb.
SITC surface mounted LED Down Lighter with white powder coated Al. housing with integrated electronic driver 15 W 840 LHEAAGP6IA2W012 complete with connection as rqd. (Havell's)
S/F surface/pendent mounting 1x18 W LED lamp channel luminaries complete with all accessories and connection etc as reqd.
S/F 450mm dia wall mounting fan complete with all accessories etc. as reqd.
Installation of exhaust fan upto 450mm sweep in the existing opening i/c making the hole to suit the size of the above fan,making good the damaged, connection testing commissioning etc.as reqd.
S/F 12"(305mm) dia light duty exhaust fan complete with all accessories
S/F fan hook i/c bolt & nuts.
S/F 48" sweep AC ceiling fan complete with down rod, blade, canopy & regulator i/c connection etc.as reqd.(Havell's Pacer) white/Brown/Ivory
S/F stepped type electronic fan regulator on the existing modular plate switch box i/c connection but excluding modular plate etc.
SITC 50W LED 5000K energy saving IP 65 Flood Light luminaries with high power COB LED as light source Havell's JETACOMPECT OF 50W LED 757LTG complete with connection as rqd. (Havell's)
S/F call bell/buzzer suitable foe DC/AC single phase 230V complete as reqd.
S/F bell push modular type complete as reqd.
S/F 25 Puro Plus water heater (Geyser) AC 2KW vertical type with all accessories GHWAPFTIV015/GHWAPFTWH025 (Havells) i/c connection etc. as reqd.(Ivory)
MS & DB Boards
Design, supply, installation testing and commissioning of L.T.Panel board of dust and vermin proof mounted with thickness of 16 SWG metal clad sheet with suitable for use at 3- Phase, 4 pole,50 Hz 415V fitted with the following switch gears of six way outgoing conforming to IS/IEC:60947-2, HSN Code 8537 :-
1. 250 amp. TPN on load changeover switch - 1 No.
2. 250 amp. TPN bus bar chamber - 1 No.
3. 125 amp. TPN thermal adjustable MCCB - 6 Nos.
P/F 125 amp TPN stand ground on load change over switch (Compact design) 415/500V including connection etc as. Reqd.
S/F bus bar chamber with 4 strips copper bus bar length 600mm suitable for 100 amp capacity complete with all accessories i/c connection earthing the body etc.as reqd.
S/F wall/floor mounted metal board of welded constn.fabricated with minimum 50mm X 50mm X6mm angle iron frame work with horizontal and vertical intermediate members of suitable angle/flat iron for mounting of switch gear i/c painting etc.
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+8 way
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
Lighting Conductor & Earthing
P/F of lightning conductor finial made of 25mm dia. 900mm long copper tube having 5-prong at top with 85mm dia. 3mm thich copper plate including holes etc. complete as required.
Fixing of lightning conductor finial 25mm dia. 900mm long copper/GI tube having 5-prong at top with 85mm dia. 3mm thick base plate i/c holes etc. as reqd.
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for vertical)
P/F copper tape 20mmx3mm thick on parapet or surface of wall for lightning conductor as reqd.(for horizontal)
Earthing with copper plate 600x600xmm thick i/c accessories and providing masonary enclosure with copper plate having locking arrangement and watering pipes etc.(but without charcoal and salt complete as reqd.)
Extra for using salt and charcoal for G.I.plates or copper plate earth electrode as reqd.
P/F 4.00 mm dia copper wire on surface or in recess for loop earthing as reqd.
Telephone Conduit
Supply and drawing (following pair) 0.5mm2 FR PVC insulated copper conductor unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as reqd.
Computer Conduit
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in PVC sassing & capping etc.as reqd.
2X4mm2+1X4mm2 earth wire
Air Conditioner
S/F 25 amp Air-Conditioner power plug point i/c 4 modules metal box on surface or in recess 4 - modules plate and cover in front, 25 amp modular starter 25 amp modular socket outlet and 25 amp plug i/c connection etc. as reqd.
Wiring for circuit/Sub-main wiring with earth wire with (the following sizes of) FR PVC ins.cu.cond single core cable in surface/recessed PVC conduit etc.as reqd.
2X4mm2+1X4mm2 earth wire
2X10mm2+1X10mm2 earth wire
S/F 1.5 tone capacity split type air conditioner (Diamond, 3 Star, 5G 29, G-SC 18 FD 3 WJH) complete with Indo voltage Stabilizer, Automatic 4 KVA (140-280 for 1.5 ton)
S/F (following way) single pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar, hinged front sacrylic cover for the MCCB knobs detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 2+4 way single door
S/F 5 amp to 32 amp rating 230V 'B' series MCB for lighting and other load of (following poles) in the existing MCB DB complete with connection testing and commissioning etc.as reqd. (a) Single pole
Supplying & fixing (following rating) double pole 240V isolator in existing MCB DB complete with connection testing & commissioning as reqd. (a) 40 amp
P/F 300x450x60mm(n/size) with permissible variation of plus minus 5mm in size wooden board complete with locking arrangement and painting etc.
S/F (following way) single/double pole and nuetral, sheet steel MCCB distributuion board, 240V on surface/recessed complete with tinned copper bus bar neutral bus bar, earth bar,din bar detachable gland plate, interconnection, phosphatized and powder painted i/c earthing etc as reqd (but without MCB/RCCB/Isolator) (a) 4 way double door
Providing and fixing (following rating) RCCB in existing cubical panel board i/c drilling holes in cubical panel making connection etc. as reqd. 63 amp. Four pole RCCB 100 mA/300mA.
Elevators
Automatic gearless elevator/lift of 26 (twenty six) passengers capable of load about 1768 kgs @ 1mt/sec. with car size 1600mmx2400mm deep, car enclosure, entrance, machine room, power operated automatic door operation including necessary assembling at site make Omega Elevators.(Gearless machine, smart elevator)
Fire Extinguisher & Fire Detector System
SECTION-A
INTERNAL HYDRANT
Providing and fixing black steel pipes for internal hydrant & sprinkler piping to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections required including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.
100mm dia NB
80mm dia NB
Providing and fixing ISI marked stainless steel fire hydrant valve 80mm single outlet with control valve and fitted with 63mm dia instantaneous female coupling at the outlet complete including companion flange as per table 'E' gunmetal blank cap and chain, nuts, bolts and 3mm thick compressed asbestos gasket at locations as per drawings (inlet flange to I.S 5290-1969 Class C).
Proving and fixing first aid fire hose reel drum wall mounting, swinging type fitted with 20mm dia 30m long high pressure type II hose to I.S. 5132 with 5mm outlet stainless steel nozzle with shut off valve (I.S 884-1969). Name of manufacturer should be embossed on the drum as well as hose.
Providing and fixing 63mm dia 15m long rubberlined fabric hose including stainless steel male and female instantaneous type coupling approved by fire authority, machine wound with copper wire complete in all respects. Hose shall conform to I.S 636 Type II and coupling to I.S 903-1975 with ISI certification (two per each single landing valve).
Providing and fixing standard short size stainless steel branch pipe with gunmetal nozzle 16mm dia outlet with standard instantaneous type 63mm dia coupling (ISI marked)
Providing and fixing standard fireman's axe with heavy insulated rubber handle tested for 20000 volts confirming to IS:926.
Supplying, installation,testing and commissioning of stainless steel office plates and having 6mm nominal thickness, upto 200mm outer dia. And internal dia. Suitable to reduce pressure to between 3.2 to 3.5 kg/sq.mm complete as required.
Providing & fixing stainless steel fire brigade inlet with 63mm dia instantaneous type inlet and 150mm dia flanged outlet with built in check valve for fir brigade connection to underground tanks and fire risers (I.S 904-1965) tested for 20kg/cm2 pressure complete in all respects with companion flanges, nuts, bolts, gaskets, etc. (a) Two way
Providing and fixing gunmetal single acting air release valve with screwed inlet 25mm dia as per IS 12992 reted for 20kg/sq.cm.
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
Providing and fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanfes as per table "E" complete in all respects.
100mm dia with lever
Providing and fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket companion flanges as per table "E" complete.
100mm dia
SECTION-B
INTERNAL SPRINKLER
Supplying and fixing M.S. pipe to I.S. 1239 (Heavy Class) complete with all fittings like, unions, coupling, bends, elbows, fees, offsets, reducers, flanges, as per table "E" etc. to complete the work as per the requirement at site including painting with one coat of primer after surface preparation and two coats of thick synthetic enamel paint, cutting and making good the walla good complete. Note: The pipe will be hung from the ceiling using GI fully threaded rods and GI Hanger rings only.
100mm dia
80mm dia
65mm dia
50mm dia
40mm dia
32mm dia
25mm dia
20mm dia
Providing & fixing 15mm dia chromium plated brass sprinkler head with quarztzoid bulb and set to operate at 68 Dec C complete in all respects.
Pendent type
Ceiling Rossette
Flexi Drop-UL Listed (upto 1000mm)
Supplying & fixing vane type waterflow switxh suitable for installation on 50mm to 150mm dia line for a service pressure upto 20kg/sq.cm to be connected to Fire Alarm Syatem.
SECTION-C
EXTERNAL HYDRANT & RING MAIN
Providing & fixing undeground black steel pipes to IS 1239/3589 heavy C class including all fittings like anchor fastners, couplings, bends, elbows, fees flanges, etc., welding as required painting with one coat of solvent based rubberised asphaltic primer and wrapping with 4mm thick multi layered pipe coat (PYPKOTE) hyper puncture resistant non woven anti corrison mat confirming to IS:10221 as per manufacturer recommendations including necessary excavations to a minimum depth of 1.2mtr refilling masonary supports complete.
100mm dia
SECTION-D
PUMPS AND ACCESSORIES
Supply, installation,testing and commissioning of electrically driven high pressure centrifugal fire hydrant/sprinkler pump, suitable for automatic operation consicting of the following:
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and ccoupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 2250 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Squirrel cage induction motor, TEFC type suitable for operation on 415volts, 3 phase 50Hz A.C supply for the above pump with synchronous speed of 2900 RPM, conforming to IP 55 protection & class F insulation. The motor shall conform to IS 325-1978 (upto date) with flexible coupling and coupling guard, complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
f. The rate includes interconnecting cables, foundations & foundation bolts.
Supply, installation,testing and commissioning of deisel engine driven fire pump suitable for automatic operation comprising of the following and conforming to BS 649/IS 10002 all amended upto date.
a. End suction centrifugal pumps, suitable for operation on 415 volts ±6%, 3 phase, 50 hz AC supply. The installation shall be complete with flexible coupling and coupling guard as required. Fire pump shall have CI casing, CS diffusers, bronze impeller (hard finised and dynamically balanced) and SS (304) shaft with machanical seal, capable for delivering 2250 LPM at outlet head 70mts to ensure a minimum pressure of 3.5kg/sqcm at the farthest or topmost hydrant/sprinkler. The installtion shall be complete with necessary pressure guage with gun metal shut off cock on delivery side (The pump should be tested and assembled for bench mark at factory and shall be gotten approved by the Local Fire Authority).
b. Pump shall be capable of furnishing not less than 150% of rated capacity at a head of not less than 65% of the rated head. The shut off head shall not exceed 120% of rated head.
c. Radiator cooled diesel engine of speed 1800 RPM suitable for the above pump with automatic starting mechanism and other accessories including fuel tank (fabricated from 3mm MS sheet, painted with two coats of synthetic enamel paint over a coat of primer) of capacity adequate to sustain pump operation fo 8 hours continuous working. The tank shall be fitted with magnetic oil lever indicator, MH with cover, drain valve, air vent including structural supports (painted with approved shade) 2 nos. x 12 volts battery, flexible coupling, coupling guard & exhaust pipe connection complete as required.
d. Common base plate for (a) and (b) from M.S. Channel for required size.
e. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
Supply, installation,testing and commissioning of jockey pump (pressurisation pump) comprising of the following:
The pump head and base shall be CI GG20 construction and impellers, diffusers, shaff sleeve, seal bush & pump shaff shall be in $$ 304 material capable of delivering 2250 LPM.The pump shall be provided with mechanical seal. The system shall be complete with necessary pressure guage with gun metal shut off cock on delivery side. (The pump should be tested and assembled for bench mark at factory)
b. Squirrel cage induction motor TEFC type for operation on 415 V, 3 phase 50 Hz AC supply for the above pump with a synchronous speed of 2900 R.P.M. with flexible coupling and coupling guard etc. as reqd.
c. Common base plate for (a) and (b) from M.S. Channel for required size.
d. Suitable cement concrete foundation with cement concrete plaster (design and drawing to be provided by the Contractor which will be duly approved by the consultant before construction) complete with anti-vibration arrangement of cushy foot mountings.
For pump defined above & of duty as follows:
Hydrant & Sprinkler System
Flow: 280 LPM
Head: 70 mts
Providing, fixing, testing and commissioning of epoxy coated MS body precharged pressure/air vessel 300 ltr capacity having a pressure rating of 1.6 bar for pressurization of hydrant/sprinkler system complete in all respect with valves to operate as per operating sequences incliding 25mm dia drain valve, air release valve duly painted from inside and outside complete as required.
SITC of Pressure guage
Supply, installation,testing and commissioning of 100mm dia bourden type, stainless steel dial type glycerine fillede pressure guage including brass isolation valve and pipe having caliberation of 0-16 kg/cm2.
Providing & fixing welded pipe suction header upto 6 mtr. Long with two inlet. All outlets and ends with flanged connections, blank, flanges as required including painting with one coat of red oxide primer and two or more coats of synthetic enamel paint to give an even shade.
200mmx6mm thick-150mmx2 inlet; 80mmx1 inlet; 150mmx1 outlet
Providing and fixing black steel pipes to I.S 1239 (Heavy class) including all fittings like couplings, bends, elbows unions, fees, flanges as per table 'E' reducers, offsets etc., making connections, all type of welded or screwed joint as per specifications and making connections required, including cutting holes and chases in brick or RCC walls and making good comlpete. After completion of the piping work the entire pipe line will be hydrauricaaly tested for a pressure of 10kg/cm2 for a period of 48 hours. The final pipe line will be painted with two or more coats of synthetic enamel paint of first grade as per IS specifications over one coat of red oxide zinc chromate primer including necessary surface preparation complete. The work will be carried out as per specification and drawings and as directed by the consultant.(Make: Tata/Jindal/Nezone)
200mm dia NB
150mm dia NB
100mm dia NB
80mm dia NB
65mm dia NB
Providing & fixing cast iron Foot valves including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion as per table
150mm dia
80mm dia
Providing & fixing C.I. horizontal dual plate wafer type non return valves PN 1.6 including washer, nuts, bolts, 1.5mm thick compressed asbestos gasket, companion flanges as per table "E" complete
150mm dia
65mm dia
Providing & fixing MS structural work fabricated from standard sections, eg., MS rounds, angels, channels, including cutting to size, drilling, welding, fixing and welding to insert plates in RCC structural members as directed by the engineer-in-charge including cutting and making good the walls and floors (for Pipe Support Structures & Cable Tray)
Providing & fixing cast iron butterfly valves of PN 1.6 rating complete with bolts, nuts, 3mm thick compressed asbestos gasket, companion flanges as per table "E" complete in all respects.
80mm dia with lever
65mm dia with lever
150mm dia with lever
Providing and fixing SS/brass ball valve full bore type tested for 20kg/cm2 with lever and screwed female ends.
25mm dia full bore type
SITC of Pressure Switches
ELECTRICAL INSTALLATION FOR FIRE PROTECTION SYSTEM
MCC for fire fightingequipments
a. 1 No. 400 amps 4 pole mechanical interlocked incoming MCCB complete with the following:
iii. Phase indicating lamp shall be protected by 2 amp SP MCB 1 set
b. Aluminium bus bar sleeves type rated at 500 amps for three phase & neutral phase bus bar shall have maximum current density of 1 amp/sq.cm and the neutral bus bar of not less than 50% capacity.
Outgoing:
b. 1 No. 32 amps TPN MCCB, 7.5 KW direct online starter with single phase preventer and outgoing feeder to jockey pump motor. The compartment shall contain CT operated ammeter of 0-30 amps & indicating lamp with MCBs for 'ON'/'OFF' TRIP status of pump motor.
c. Providing and fixing 1 No. auto start panel activated with pressure switch for diesel engine complete with all accessories, batteries, battery charger of suitable rating, MCB timers, push buttons, microprocessor based alarm annunclator, wiring and cabling including connection to diesel engine complete as required ready for working.
d. Necessary cable alleys space for spare switchs, internal wiring and copper earthing of all equipment shall also be included. All switch gears/control gears shall be motor duty rating.
Note: All MCCB's to be suitable for motor duty shall be of 36KA breaking capacity.
Provision shall be made for providing potential free contacts to all pumps starters for connection for building automation system.
MCC as described above
SECTION-E
HAND APPLIANCES
Providing and fixing mechanical foam type fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:10204 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 9 kg (Pump Room & DG Set)
Providing and fixing store pressure ABC fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:13849 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 6 kg
Providing and fixing carbondioxide fire extinguishers consisting of welded M.S. cylindrical body squeeze lever discharge valve fitted with internal discharge tube, 30 cms long high pressure discharge hose, discharge nozzle, suspension bracket, ISI marked as per IS:2878 finished externally with red enamel paint and fixed to wall with brackets complete with internal charges.Capacity 4.5 kg
Providing and fixing at approved location approved make 4 nos., for buckets of 24 guage galvanised steel, painted white inside and red outside and black on the bottom, inscribed with letters "FIRE" in black nd gold including stand fabricated out to sheet metal (16 guage) shade, platform and associated civil works, painting etc. as approved by the department.
F. FIRE ALARM
Supply, intallation, testing and commissioning of Conventional optical smoke detector with base complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of Conventional Hooter complete in all respect Morley, Apollo, System Sensor
Supply, intallation, testing and commissioning of PVC Body Manual Call Point (non-glass type) complete in all respect Morley, Apollo, System Sensor, Agni
Supply, intallation, testing and commissioning of Conventional Fire Alarm Panel System Sensor, Ravel, Agni
Microprocessor controller and LCD Display
Supplying, drawing, connecting, testing & commissioning of 2 corex1.5 sq.mm multi stranded copper conductor, pvc insulated PVC sheathed, aluminium myler tape shielded armoured cable suitable for Fire Alarm System. Havells, Polycab, Crystal, Gloster.
M Gunananda Sharma
Yumkham Subhaschandra Meetei
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid