Chief Engineer, HMDA
7th floor, East wing, Swarnajayanthi complex, Myrtivanam, Ameerpet, Hyderabad
Proposed Civil and Interior works in Annexe-I and II buildings, at Paigah Palace, Begumpet
730671
HMDA/DEV/CE/14/01/2026-27, Dt:02.09.2026
OPEN
Civil Works
HYDERABAD, TELANGANA
1 document required · 1 mandatory
₹11,800
₹5.5 L
5 Sept 2026
5 Sept 2026
5 Sept 2026
Dismantling, clearing away and carefully stacking useful materials for re-use and disposal of unserviceable materials with 100m lead as directed by Executive Engineer duly taking actual premeasurements before dismantling including labour all charges, TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. refer civil dismantle drawings for Annexe-I Building Civil & Interior Works
Unreinforced cement concrete up to 15cm thickness (Ramp& Steps) including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Dismantling and Removing of Roof Sheet & Truss and Double height Roof Sheet at Connecting Lobby Including Trusses, Railing around the Annex-I and Annex-II Bulding including cost of labour and lifting charges etc., including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
Dismantling doors, windows and clear storey windows, Ventilators etc., (wood or steel) shutters including Chowkhats, architraves,hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge . for Annexe-I Building Civil & Interior Works
Masonry work in CM (1:6) prop (Cement : Screened sand) in superstructure with fly ash cement / lime solid blocks of size 290mm x 225mm x 140mm from approved source having minimum crushing strength of 50 Kg/Sqcm. including cost and conveyance of all materials like cement, sand, bricks, water etc., to site, including sales & other taxes on all materials and such as labour charges, like mixing cement mortar, scaffolding charges, constructing masonry, lift charges, curing, including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (APSS No. 501 & 504).for Annexe-I Building Civil & Interior Works
Plastering 12mm thick in two coats using screened sand with base coat of 8mm thick in CM (1:6) and top coat of 4mm thick in CM (1:4) with dubara sponge finishing including cost and conveyance of all materials like cement, sand, water etc., to site, including sales & other taxes on all materials, and all operational, incidental charges on materials and including cost of all labour charges for mixing mortar, finishing, scaffolding, lift charges, curing, including cutting grooves including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (SS 901,903 & 904). for Annexe-I Building Civil & Interior Works
Painting to new walls with 2 coats of water proof cement paint of shade as approved by the Engineer-In-Charge over a base coat of aproved white cement base coat making 3 coats in all to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc., and overheads & contractors profit etc., excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge as per SS 912 in all floors for Annexe-I Building Civil & Interior Works
Providing and Fixing Pre painted Steel Sliding Windows / Doors - 3 track sliding window /doors shutter with mesh shutter – (2 - glass shutters and 1 - mesh shutter) fabricated from Roll formed sections made of galvanized Steel colour coated/powder coated (Base Steel as per IS 513 ‘D’ quality, galvanized as per IS 277 with zinc of 120 GM/Sq.mtr) with total coated thickness of 0.58mm. Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick. Section for external frame should be of 44 x 107mm .Section for glass shutter and mesh shutter in case of door should be of 35 x 67 mm Section for euro groove should be 25 x 31mm (Aluminium/ Plastic) (in case of window sections should be 35 x 49 mm and 25 x 24 mm and 30 x 41 mm) and Lap Strip should be of 39 x 41mm (30 x 41 mm & Touch lock for window ) (Aluminium/ Plastic. The doors/ windows should be panelled with 5mm thick plain float glass. Corner bracket for internal and external frame made of glass filled nylon. Gaskets are to be made of Ethyl Propylene Diamine Monomer (EPDM).The sections are to be cut to length, joined and assembled by means of corner bracket. The above frames should be fixed to the concrete/masonry walls by means of self expanding brackets & screws including 10mm square guard bars with 6” pitch (152.4mm) (in case of windows only) and all Taxes including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
Providing and Fixing Structural Glazing fabricated from Roll formed sections made of Pre-painted Steel / Powder coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 Gm/Sqm) with total coated thickness of 0.72mm. The glass holding section made of 304 grade stainless steel of 0.6mm thick as per the design requirement & calculations as given in IS: 875. Primer coat with epoxy primer of 5 – 7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with Alkyd backer of 5-7 microns or powder coated with pure polyester powder up to 50-60 microns thick. The vertical section should be of 50mm x100mm x 0.72mm, 33mm x 58mm x 0.72mm for frame horizontal section, stiffener section should be 48mm x 98mm x 1mm, cover profiles sections should be of 20mm x 58mm x 0.58mm, Glass holding section should be of 37mm x 37mm & 37mm x 18mm. Including 5mm thick Ocean Blue reflective glass. Brackets made of CRCA powder coated/Electroplated should be used to connect vertical to horizontal, vertical to slab, to fix verticals at top & bottom as per site requirement. Gasket made of Ethyl Propylene Diamine Monomer. Natural cure, with Good U.V. Resistance Silicon to be used. Wall fixing of sections to concrete/masonry wall should be with self-expanding cap & screws. The rate is inclusive of cost and conveyance of all materials to site, all labour charges, incidental charges, cost of all consumables etc. and scaffolding charges, form work , including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge in all floors.Fixed Glazing 3'-0" x 3'-0" (914.4x914.4mm), 3'-0" x 4'-0" (914.4x1219.2mm) grid outer frames section size of 46 x 52 mm for Annexe-I Building Civil & Interior Works
Painting to old walls with 2 coats of water proof cement paint of shade as approved by the Engineer-In-Charge to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc., including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge as per SS 912 in all floors. (BLD-CSTN-12-4) for Annexe-I Building Civil & Interior Works
Providing & fixing of nylon 6.6. fiber based anti- microbial sanitized carpet roll of 4.3mm thickness. The carpet should be 100% washable and stain resistant. The carpet should be commercial grade of class33 and total weight of carpet should be 1.8kg/m2. Acoustical sound impact should be of 20dB. The product should carry 10 years warranty and allergy certificate. Installation should be done by authorized installer of company including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Supply of Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 800 x 800 mm and thickness between 9-11 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (APSS No.701 & 707). for Ground Floor for Annexe-I Building Civil & Interior Works
Supply of Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 800 x 800 mm and thickness between 9-11 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (APSS No.701 & 707). for First Floor for Annexe-I Building Civil & Interior Works
Supply of Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 800 x 800 mm and thickness between 9-11 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (APSS No.701 & 707). for Second Floor for Annexe-I Building Civil & Interior Works
Supply of Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 800 x 800 mm and thickness between 9-11 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (APSS No.701 & 707). for Third Floor for Annexe-I Building Civil & Interior Works
Providing Skirting to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-chargek.(APSS No.701 &707) for Ground Floor for Annexe-I Building Civil & Interior Works
Providing Skirting to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.(APSS No.701 &707) for First Floor for Annexe-I Building Civil & Interior Works
Providing Skirting to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.(APSS No.701 &707) for Second Floor for Annexe-I Building Civil & Interior Works
Providing Skirting to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.(APSS No.701 &707) for Third Floor for Annexe-I Building Civil & Interior Works
The raised floor system to be in installed shall provide a minimum finished floor height of 125mm upto 600mm from the existing level. The system shall provide for suitable pedestal and understructure design to withstand varioous static loads and rolling loads subjected to it in an office/ DCS/Server/ Panel etc. The system shall be able to accept, approved laminated floor covering anti static PVC/ anti static laminate and PVC beading on all sides of the panel. The over all system shall be able to withstand a UDL of 1080/1350 kgs per Sq.mt. and a point load of 36/450 kgs. The understructure will withstand Axial load of 2200 kgs. False flooring. Panels Comfloor Solid Fill SFD - 800/1000 shall be made from steel. The bottom of the panel shall be embossed in 64 hemispherical shape of 60 mm dia.The top sheet shall be plain and resistant welded at varioous locations after the top and bottom sheets have been degreased and phosphated. the above hallow panel shall have an infill of light weight cementation material. The entire panel shall be coated with epoxy coating on the exposed surface. Panels shall remain flat through and stable uneffeted by humidity or flactuation in temparature throughout its normal working life. Panels shall provide for impact resistance top surfaces minimal deflection. Corrosion resistance properties and shall not be combusstible or aid surface spread of flame. Panels shall be insulted against heat and noise transfer. Panels shall be 604x604 mm and shall have a maximum flange of 12mm on all four sides(for resisting on strings), fully interchangeable with each other within the range of a specified layout. Panels shall rest on the grid formed by the stringers, which are bolted onto the pedestals. Panels shall be factory laminated Anti-static PVC/ Laminate on the top and PVC beading/ trimming along the edges.including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Supplying and fixing Gyp Board tiles of size not less than 0.595 M x 0.595 M of 12.5 mm thick Suspended regular single layer false ceiling (GS-MFSC-4.1) using 12.5 mm thick Gyp Board conforming to IS 2095 - 1993 fixing to Gyp steel GI perimeter channels of size 20 mm x 27 mm x 30 mm(web) of 0.55 mm thick along the perimeter of ceiling screw fixed to brick work/ partition at 610 mm c/c and suspending the frame work using Intermediate channels (45 mm x 15mm x 15mm x 0.9 mm) from soffit at 1220 mm c/c with ceiling angle (25 mm x 10 mm x 0.55 mm) fixed with GI Cleat and steel expansion fasteners & connecting clip to the ceiling channels (with knurled web of 51.5 mm x 26 mm x 10.5 mm x 0.55 mm) fixed in direction perpendicular to the intermediate channel at 457 mm c/c and fixing the 12.5 mm tapered edge Gypboard with 25 mm drywall screws at 230 mm c/c & jointing and finishing using joint compound and paper tape to have a flush look including filling the tapered & square edges with jointing compound, two coats of drywall topcoa including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Supplying and fixing Gyp board Fine line Grid false ceiling (GS-FLC-4.6)using 12.5mm thick Gyp Board sheet tiles of size 595mm x 595mm conforming to IS 2095 - 1992 fixing to Gyp steel precoated GI wall angle of size 25mm x 25mm x 0.70mm thick along the perimeter of ceiling screw fixed to brick work / partition at 610mm center to center and suspending the frame work using precoated GI Tee section (24mm x 38mm x 0.7mm) from soffit at 1220mm center to center fixed with GI Soffit Cleat, rawl plugs and steel expansion fasteners & connecting clip to the GI Tee section with 4mm dia GI rod with galvanised spring steel level clip of PVC unversal holding clips system at 1200mm center to center and fixing the 12.5mm Gypboard sheet tiles of size 595mm x 595mm and finishing two coats of drywall top coat, including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge in all floors.(BLD-CSTN-10-32 & vide Page No. 390 of SoR 2011-12) for Annexe-I Building Civil & Interior Works
Providing and fixing linear metal baffle ceiling system using 0.6 mm thick aluminium alloy 3105 H24, 100 mm high x 25 mm wide baffles with PVDF coating 25 microns, spaced at 100 mm c/c. System includes 0.8 mm GI carrier channel, 4 mm GI hangers, perimeter trim, and 50 mm 48 kg/m³ rockwool with black tissue backing. The system shall be suspended from RCC slab with M6 fasteners, laser leveled, with individual demountability. Make: Hunter Douglas/Luxalon, Armstrong, Saint-Gobain Gyproc, or equivalent approved.including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Glass Partition : Supply and fixing of Aluminium Fixedstyle partitions with Aluminium Powder coated sections of 40x25x1.5mm with 10mm clear toughned glass including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Wood partition :Providing and fixing full-height/partial-height wooden partition comprising wooden framework shall be made from kiln-seasoned hardwood or chemically treated sal wood of Minimum section size 50mm x 50mm (2” x 2”), Members shall be placed at maximum 600mm c/c horizontally and vertically.Framework shall be rigidly fixed to floor, walls, and ceiling using approved screws, cleats, dash fasteners, and anchor fasteners.All wooden members shall be straight, free from warping, cracks, and termite infestation. Necessary preservative and anti-termite treatment shall be applied before installation. boarding, insulation, laminate finish, glass inserts, and all necessary accessories complete as per approved drawings and site conditions including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
Providing and fixing 18mm thk marine plywood with framework made out of ghana wood sections and finished with 1mm thick laminate as per approved shade with grooves as per detailed drawings etc., and as approved by architect including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.for Annexe-I Building Civil & Interior Works
Hey Concrete Panel Cladding at Ground Floor Reception Backside Wall including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Supplying and fixing of 16 to 18 mm thick High Polished Granite stone slabs black colour as approved by the Engineer-in-Charge of length not less than 2.43 mts set over granite platform and fixing with polymer cementitious additive granite slabs etc., to work site and all operational, incidental labour & lift charges, half rounding the edge , polishing charges and all other taxes exceluding GST on all materials, cost of base coat and including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for platforms (S.S.701 & special) for Annexe-I Building Civil & Interior Works
Providing and fixing of storage cabinet made out of 18mm thk marine ply wood used as structure, 6mm thk marine plywood for backing, shelves of 18mm thick marine plywood, shutters made out of 18mm thk marine plywood operated on auto closing hinges "HAFELE" make with necessary knock down fittings. Storage shall have all necessary hardware like hinges, locks, handles etc., and finished with 1mm thk laminate extyernally, Internally the storage shall be finished with 8mm thk laminate as per approved asmple. Complete as shown in the drawing and design including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.for Annexe-I Building Civil & Interior Works
Providing and fixing 1200 mm height and 500mm depth storage cabinet made out of 18mm thk marine ply wood used as structure, 6mm thk marine plywood for backing, shelves of 18mm thick edge polished clear glass shelves fixed to vertical supports with SSD brackets, 19mm thk marine ply board finished with 4mm thk veneer shade of approved shall be fixed at top, shutters made out of 18mm thk marine plywood operated on 2 no's of auto closing hinges "HAFELE" make with necessary knock down fittings. Storage shall have a shelf with file manager unit made from 100mm x 8mm aluminium extruded section and 6mm M.S. bright powder coated bar with all necessary hardware like hinges, locks, handles etc., All exposed edges of shelves shall be covered with 2mm thk imported pvc edges glued to it. All Internal faces should be finished with 8mm thk laminate and external faces sfinished with 1 mm thk laminates as per approved asmple. Complete as shown in the drawing and design or as directed by Architect including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
Storage in toilets shall be made with 19mm bwp board finished with 1mm thk laminate on external sides and 8mm thk laminate on internal sides as per design and detail including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
Providing and fixing the vertical blinds (Make Mr. . Miniblinds / macro l) and shall have have head rail of extruded anodized high strength aluminum ally 45x35mm high with wall thick of 12mm. The head rail shall have 15mm decorative insert on side of the head rail. Control units shall be derling brown) and shall consist of titling control and the transparent acrylic with anti friction additive. The spacer shall be of 14 gauge gal vanished spring steel. Lover fabric shall be polyester viscous / polyester yarn duly scotchquary treated any dyed in fast colours including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
Supply and fixing of Aluminiumstyle doors with powder coated aluminium sections outer frame of 50x38x1.8mm and shutter of 75x40x1.5mm with 8mm clear toughned glass, hinges, deadlock, oval cap, cylender and ooset handle 450mm. Door size 900x2100mm (GD-0.90x2.1) including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Providing and fixing of 900 × 2100 mm internal office door comprising 35 mm thick solid-core flush door shutter, finished with 1.0 mm thick approved laminate on both faces, with hardwood lipping on all four sides. Door frame shall be of seasoned hardwood, 100 × 75 mm, with necessary rebates and grooves, duly polished/laminated as approved including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
Door frame: Door frame shall be made using 65 × 100 mm seasoned Ghana wood frame. Frame will have all necessary fixing hardware like holdfasts, screws etc. Door shutter: Providing and fixing of 30 mm thick waterproof plywood/flush door shutter as per approved sample, finished with 1 mm thick laminate on both sides. Shutter shall have hardwood lipping on all four sides and necessary grooves/inlay as per design. Shutter shall be provided with SS brushed-finished lever handle, lock, tower bolt and all necessary hardware in SS matt finish, including heavy-duty SS hinges and door stopper, complete as approved by the Architect including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-I Building Civil & Interior Works
GLASS SLIDING DOOR AT GROUND FLOOR ENTRANCE AUTOMATED MOTORISED DOOR including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-I Building Civil & Interior Works
Dismantling doors, windows and clear storey windows, Ventilators etc., (wood or steel) shutters including Chowkhats, architraves,hold fasts and other attachments etc., and stacking them within 100m lead including labour charge etc., and including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-II Building Civil & Interior Works
Painting to old walls with 2 coats of water proof cement paint of shade as approved by the Engineer-In-Charge to give an even shade after thourughly brushing the surface to remove all dirt and remains of loose powdered materials, including cost and conveyance of all materials to work site and all operational, incidental, labour charges etc., and including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge as per SS 912 in all floors. for Annexe-II Building Civil & Interior Works
Providing & fixing of nylon 6.6. fiber based anti- microbial sanitized carpet roll of 4.3mm thickness. The carpet should be 100% washable and stain resistant. The carpet should be commercial grade of class33 and total weight of carpet should be 1.8kg/m2. Acoustical sound impact should be of 20dB. The product should carry 10 years warranty and allergy certificate. Installation should be done by authorized installer of company including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
Supply of Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 800 x 800 mm and thickness between 9-11 mm 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs as per the approved flooring pattern as directed by the Engineer-In -Charge, laying tiles using spacers of 2mm thick, set over a base coat of CM (1:8) prop. 12mm thick using screened sand over CC bed already laid or RCC roof slab , including neat cement slurry of honey like consistancy spread @ 3.3 kgs per Sqm. and jointed neately with white cement paste to full depth mixed with pigment of matching shade including cost and conveyance of all materials like cement, sand, water, tiles, white cement etc., to site (excluding cost of C.C. bed) including cost of base coat and all labour charges for mixing of cement mortar, laying tiles to required slope including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (APSS No.701 & 707). for Annexe-II Building Civil & Interior Works
Providing Skirting to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.,and oincluding TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.(APSS No.701 &707) for Ground Floor for Annexe-II Building Civil & Interior Works
Providing Skirting to walls with Double charged / multi charged stain free full body porcelain vitrified tiles with double layer pigment of size 600 x 600 mm and thickness between 8-10 mm 1st quality conforming to IS:13711, IS:13712, IS:13630 (Parts 1 to 15) of any colour and finish in all shades and designs, length equal to flooring tiles, set over base coat of CM(1:5) 12 mm thick using screened sand with cement slurry of honey like consistency spread at the rate of 3.30 kgs per sqm and jointing with white cement paste mixed with pigment of matching shade to full depth, including cost of all materials like tiles, cement, sand and water etc.including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.(APSS No.701 &707) for First Floor for Annexe-II Building Civil & Interior Works
Flooring with non-skid full body ceramic floor tiles of size 600mm x 600mm and thickness between 8 - 10mm 1st quality conforming to 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1to 15) of any colour and finish in all shades anddesigns as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (In toilets) (APSS No.701 & 707). for Ground Floor -Toilet for Annexe-II Building Civil & Interior Works
Flooring with non-skid full body ceramic floor tiles of size 600mm x 600mm and thickness between 8 - 10mm 1st quality conforming to 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1to 15) of any colour and finish in all shades anddesigns as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., and including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (In toilets) (APSS No.701 & 707). for First Floor -Toilet for Annexe-II Building Civil & Interior Works
Flooring with non-skid full body ceramic floor tiles of size 600mm x 600mm and thickness between 8 - 10mm 1st quality conforming to 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1to 15) of any colour and finish in all shades anddesigns as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (In toilets) (APSS No.701 & 707). for Second Floor -Toilet for Annexe-II Building Civil & Interior Works
Flooring with non-skid full body ceramic floor tiles of size 600mm x 600mm and thickness between 8 - 10mm 1st quality conforming to 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1to 15) of any colour and finish in all shades anddesigns as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (In toilets) (APSS No.701 & 707). for Third Floor -Toilet for Annexe-II Building Civil & Interior Works
Flooring with non-skid full body ceramic floor tiles of size 600mm x 600mm and thickness between 8 - 10mm 1st quality conforming to 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1to 15) of any colour and finish in all shades anddesigns as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., aincluding TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (In toilets) (APSS No.701 & 707). for Forth Floor -Toilet for Annexe-II Building Civil & Interior Works
Flooring with non-skid full body ceramic floor tiles of size 600mm x 600mm and thickness between 8 - 10mm 1st quality conforming to 1st quality conforming to IS:15622 - 2017, IS:13630 (Parts 1to 15) of any colour and finish in all shades anddesigns as approved by Engineer-in-charge, set over base coat of cement mortar (1:8), 12mm thick using screened sandover CC bed already laid or RCC roof slab, including neat cement slurry of honey like consistency spread @ 3.3 Kgs per Sqm & jointed epoxy emulsion grout/ synthetic /resin adhesive in width of 3-5 mm with Nylonspacers excluding cost of tiles neatly with to full depth mixed with pigment of matching shade, including cost of all materials like cement, screened sand , water and tiles etc., including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. (In toilets) (APSS No.701 & 707). for Fifth Floor -Toilet for Annexe-II Building Civil & Interior Works
HSN Code / Description - 69109000 / UNDER COUNTER BASIN, SIZE: 480X370X200 M including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 74182010 / WASTE COUPLING 32MM SIZE FULL THREAD WITH 80MM HEIGHT including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 84818020 / PILLAR COCK including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 69109000 / RIMLESS SINGLE PIECE WC WITH UF SOFT CLOSE SLIM SEAT COVER, HINGES, DUAL FLUSH CISTERN FITTING, FIXING ACCESSORIES, SIZE: 350X650X710 MM, S TRAP- 220 MM including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 74182010 / BOTTLE TRAP (WITH INTERNAL PARTITION) 32mm SIZE WITH 300mm & 190mm LONG WALL CONNECTION PIPES & WALL FLANGE including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 39221000 / HAND SHOWER (HEALTH FAUCET) WITH 8MM DIA 1 METER LONG FLEXIBLE TUBE AND WALL HOOK including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 74182010 / TOILET ROLL HOLDER WITH SHELF including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 85163300 / FLASH TOUCH-FREE INFRARED HAND DRYER WITH 1150W RATED POWER & CARBON BRUSH MOTOR including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 96161020 / SOAP DISPENSER - PUSH BUTTON CAPACITY: 0.8L MATERIAL: ABS FINISH: WHITE/SMOKED including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
HSN Code / Description - 69109000 / URINAL WITH SENSOR KIT, SPREADER AND FIX including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
Supplying and fixing Gyp Board tiles of size not less than 0.595 M x 0.595 M of 12.5 mm thick Suspended regular single layer false ceiling (GS-MFSC-4.1) using 12.5 mm thick Gyp Board conforming to IS 2095 - 1993 fixing to Gyp steel GI perimeter channels of size 20 mm x 27 mm x 30 mm(web) of 0.55 mm thick along the perimeter of ceiling screw fixed to brick work/ partition at 610 mm c/c and suspending the frame work using Intermediate channels (45 mm x 15mm x 15mm x 0.9 mm) from soffit at 1220 mm c/c with ceiling angle (25 mm x 10 mm x 0.55 mm) fixed with GI Cleat and steel expansion fasteners & connecting clip to the ceiling channels (with knurled web of 51.5 mm x 26 mm x 10.5 mm x 0.55 mm) fixed in direction perpendicular to the intermediate channel at 457 mm c/c and fixing the 12.5 mm tapered edge Gypboard with 25 mm drywall screws at 230 mm c/c & jointing and finishing using joint compound and paper tape to have a flush look including filling the tapered & square edges with jointing compound, two coats of drywall topcoa including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
Providing and fixing linear metal baffle ceiling system using 0.6 mm thick aluminium alloy 3105 H24, 100 mm high x 25 mm wide baffles with PVDF coating 25 microns, spaced at 100 mm c/c. System includes 0.8 mm GI carrier channel, 4 mm GI hangers, perimeter trim, and 50 mm 48 kg/m³ rockwool with black tissue backing. The system shall be suspended from RCC slab with M6 fasteners, laser leveled, with individual demountability. Make: Hunter Douglas/Luxalon, Armstrong, Saint-Gobain Gyproc, or equivalent approved including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-II Building Civil & Interior Works
Providing and fixing 18mm thk marine plywood with framework made out of ghana wood sections and finished with 1mm thick laminate as per approved shade with grooves as per detailed drawings etc., and as approved by architect including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
Supply and fixing of Aluminium Fixedstyle partitions with Aluminium Powder coated sections of 40x25x1.5mm with 10mm clear toughned glass including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
Providing and fixing full-height/partial-height wooden partition comprising wooden framework shall be made from kiln-seasoned hardwood or chemically treated sal wood of Minimum section size 50mm x 50mm (2” x 2”), Members shall be placed at maximum 600mm c/c horizontally and vertically.Framework shall be rigidly fixed to floor, walls, and ceiling using approved screws, cleats, dash fasteners, and anchor fasteners.All wooden members shall be straight, free from warping, cracks, and termite infestation. Necessary preservative and anti-termite treatment shall be applied before installation. boarding, insulation, laminate finish, glass inserts, and all necessary accessories complete as per approved drawings and site conditions including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-II Building Civil & Interior Works
Providing and fixing of storage cabinet made out of 18mm thk marine ply wood used as structure, 6mm thk marine plywood for backing, shelves of 18mm thick marine plywood, shutters made out of 18mm thk marine plywood operated on auto closing hinges "HAFELE" make with necessary knock down fittings. Storage shall have all necessary hardware like hinges, locks, handles etc., and finished with 1mm thk laminate extyernally, Internally the storage shall be finished with 8mm thk laminate as per approved asmple. Complete as shown in the drawing and design including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-II Building Civil & Interior Works
Providing and fixing 1200 mm height and 450mm depth storage cabinet made out of 18mm thk marine ply wood used as structure, 6mm thk marine plywood for backing, shelves of 18mm thick edge polished clear glass shelves fixed to vertical supports with SSD brackets, 19mm thk marine ply board finished with 4mm thk veneer shade of approved shall be fixed at top, shutters made out of 18mm thk marine plywood operated on 2 no's of auto closing hinges "HAFELE" make with necessary knock down fittings. Storage shall have a shelf with file manager unit made from 100mm x 8mm aluminium extruded section and 6mm M.S. bright powder coated bar with all necessary hardware like hinges, locks, handles etc., All exposed edges of shelves shall be covered with 2mm thk imported pvc edges glued to it. All Internal faces should be finished with 8mm thk laminate and external faces finished with 1 mm thk laminates as per approved asmple. Complete as shown in the drawing and design or as directed by Architect including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.for Annexe-II Building Civil & Interior Works
Providing and fixing 600mm in height and 350 mm deep storage made out of 18mm thk marine plywood, 6mm thick marine plywood for backing. One number of shelf made ou of 18mm thk marine plywood as shown in the drawing. 25mm thick ply board finished with 1mm thk laminate fixed as top. Shutter made out of 18mm thk plywood operated on 2nos. of auto closing hinges, locks, handles etc. of approved quality. Over head storage will have adjutable file manager internally the storage shall have intermidiate shelf. All exposed edges of shelves shall be covered with PVC edges. Complete as shown in drawing or design including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.for Annexe-II Building Civil & Interior Works
Storage in toilets shall be made with 19mm bwp board finished with 1mm thk laminate on external sides and 8mm thk laminate on internal sides as per design and detail including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.for Annexe-II Building Civil & Interior Works
Providing and fixing the vertical blinds (Make Mr.Miniblinds / macro l) and shall have have head rail of extruded anodized high strength aluminum ally 45x35mm high with wall thick of 12mm. The head rail shall have 15mm decorative insert on side of the head rail. Control units shall be derling brown) and shall consist of titling control and the transparent acrylic with anti friction additive. The spacer shall be of 14 gauge gal vanished spring steel. Lover fabric shall be polyester viscous / polyester yarn duly scotchquary treated any dyed in fast colours including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.for Annexe-II Building Civil & Interior Works
Supply and fixing of Aluminiumstyle doors with powder coated aluminium sections outer frame of 50x38x1.8mm and shutter of 75x40x1.5mm with 8mm clear toughned glass, hinges, deadlock, oval cap, cylender and ooset handle 450mm. Door size 900x2440mm including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
GLASS SLIDING DOOR AT GROUND FLOOR ENTRANCE AUTOMATED MOTORISED DOOR including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge for Annexe-II Building Civil & Interior Works
Providing and fixing of 1000 × 2100 mm internal office door comprising 35 mm thick solid-core flush door shutter, finished with 1.0 mm thick approved laminate on both faces, with hardwood lipping on all four sides. Door frame shall be of seasoned hardwood, 100 × 75 mm, with necessary rebates and grooves, duly polished/laminated as approved including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge. for Annexe-II Building Civil & Interior Works
Door frame: Door frame shall be made using 65 × 100 mm seasoned Ghana wood frame. Frame will have all necessary fixing hardware like holdfasts, screws etc. Door shutter: Providing and fixing of 30 mm thick waterproof plywood/flush door shutter as per approved sample, finished with 1 mm thick laminate on both sides. Shutter shall have hardwood lipping on all four sides and necessary grooves/inlay as per design. Shutter shall be provided with SS brushed-finished lever handle, lock, tower bolt and all necessary hardware in SS matt finish, including heavy-duty SS hinges and door stopper, complete as approved by the Architect including TP, overheads & contractor profit etc.,but excluding seignorage charges complete for finished item of work and as directed by Engineer-in-charge.for Annexe-II Building Civil & Interior Works
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Interior & civil Works Paigah palace Tender Document.docx
TENDER_DOCUMENT • 0.15 MB
BOQ Annex-I & II Interiors.xlsx
TENDER_DOCUMENT • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .