Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹84,525.30Admitted-Finance | ₹84,525.30 | L1 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAJMAL GURJAR L1 |
|---|---|---|---|---|
| 1.00Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | ||||
| 2.00 | Nominal bore 150 mm dia. | 1 | Mtr | 653.4 ₹653.4 Lowest |
| 3.00Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | ||||
| 4.00 | Nominal bore 200 mm dia. | 1 | Mtr | 980.1 ₹980.1 Lowest |
| 5.00Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. | ||||
| 6.00Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes | ||||
| 7.00 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) | 1 | Mtr | 1,739.7 ₹1,739.7 Lowest |
| 8.00 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) | 1 | Mtr | 2,460.6 ₹2,460.6 Lowest |
| 9.00Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. | ||||
| 10.00 | Up to 2.0 KW | 1 | KW | 15,085.8 ₹15,085.8 Lowest |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
7 Sept 2026, 6:00 pmClosed
VDO
PANCHAYAT SAMITI NADOTI
Installation of Handpump / Single Phase Tube Well with Material in Gram Panchayats under Panchayat Samiti Nadoti
2026_PRD_593980_1
4239
Open Tender
Miscellaneous Goods
Item Rate
90 days
NADOTI
Please refer Tender documents.
3 documents required · 3 mandatory
₹500
VDO/MDRISL
₹1 L
Yes
17 Sept 2026
1 Sept 2026
8 Sept 2026
1 Sept 2026
7 Sept 2026
1 Sept 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | - | - | - | - |
| 2 | Nominal bore 150 mm dia. | - | Mtr | 100 | - |
| 3 | Construction of Tube Well up to 100 mtr. depth in all type of rocks by DTH system & over burden to accommodate casing pipe of following sizes in all types of soils & over burden including lowering of casing pipes, (if required) excluding cost of casing pipes, as per IS:2800 Part 1: 1991 and IS:2800 Part II: 1979 (both amended up to date) and technical specifications. The work would be completed after obtaining sand free water. The tube well should have a through out bore as per nominal dia of casing pipe. | - | - | - | - |
| 4 | Nominal bore 200 mm dia. | - | Mtr | 10 | - |
| 5 | Add 15% extra on above item (Item No 2.4.1 to 2.4.2) for drilling depth beyond 100 mtr and up to 200 mtr from ground level, rate shall be applicable for only extra depth beyond 100 mtr and up to 200 mtr. | - | - | - | - |
| 6 | Supply of ERW M.S. black casing pipe ISI marked (IS: 4270/2001) or amended up to date of following sizes | - | - | - | - |
| 7 | 150 mm dia NB(Thickness of pipe 5.0 mm & mass of tube 20.13 Kg/m) | - | Mtr | 10 | - |
| 8 | 200 mm dia NB (Thickness of pipe 5.4mm & mass of tube 28.46 Kg/m) | - | Mtr | 10 | - |
| 9 | Supply & Installation of single phase ISI marked submersible motor pump set of three star or better rating of BEE and as per IS: 8034-2018 (pump) and IS 9283-2013 (motor) or as amended up to date of approved make of following duty condition with required accessories including making connection suitable for tube well/DCB. The job includes lowering of motor pump, installation of complete fitting & accessories, jointing of electrical cables up to switch board, testing of submersible pump set and interconnection up to water mains, complete in all respect. | - | - | - | - |
| 10 | Up to 2.0 KW | - | KW | 10 | - |
stage.html
html • 0.02 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 7.46 MB
BOQ_1054172.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .