| Sl No | Description | Qty | Unit | power system L1 | SAKTHI ENGINEERS L2 |
|---|---|---|---|---|---|
| 1.00Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 of MoRT&H specifications for road and bridge works (4th Revision) and as directed by the Engineer-in-charge. | |||||
| 1.10 | for Grading-I material | 100 | Cu.m | 2,000 ₹2,00,000 Lowest | 2,400 ₹2,40,000 |
| 2.00 | Dewatering from trenches, sump, foundation structure using electrical submersible or suitable pump of required capasity with necessary arrangements to the nearest storm water drain or at places shown as directed by EIC including HDPE pipe, maintenance of the system, cost of spares, idling, labour for operation etc. Mode of measeurement will be power consumption in KWh.
Note: 1. This item will be operated during abnormal bad weather, surface run off from outside scope of work only.
2. Diesel operated pumps shall also be operated as and when directed by the Engineer-in-charge. | 1,000 | Kwh | 75 ₹75,000 Lowest | 200 ₹2,00,000 |
| 3.00Providing and laying cast insitu controlled reinforced cement concrete of specified grade at all levels and lifts mentioned below using 20mm maximum size hard granite machine washed crushed graded stone aggregates and washed crushed stone sand including testings as per QAP, weigh batching, charges for mixing & cost of admixture, mechanical mixing, transporting and placing at all lifts, vibrating, consolidating, 14 days curing and finishing smooth of all exposed faces complete for column footing, columns, lintels, sunshades, gutter slabs, beams, slabs, water tank, machine foundation and all other structural elements including dewatering wherever necessary (Formwork and reinforcement will be paid for separately) all as per specification and all as shown in drawings and as directed by the Engineer-in-charge for all insitu item. Note: 1. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Polycarboxylate ether (PCE) based chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer-in-charge shall be obtained for dosage and compatibility 2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor. 3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/ downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F. | |||||
| 3.10 | M30 grade with 380 kg of PPC per cu.m. of concrete for all floors | 180 | Cu.m | 11,000 ₹19,80,000 Lowest | 12,500 ₹22,50,000 |
| 4.00 | Supplying, fabricating, erecting and fixing in position at all levels, centering and shuttering to correct line and levels including strutting, propping, etc., with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof and with provision for fixing coil nuts with tie rods along with suitable channel for lateral supports and for inserts, projecting dowels, anchor bolts or any other fixture, including staging, access and working platforms etc., all complete as specified and directed including dismantling and removing the aforesaid assembly after the concrete attains the sufficient strength to self-support itself without cracking and distortion all as per specification, including all materials and labour complete in all respects at all lifts. The measurement for the formwork will be the actual area of forms in contact with concrete surfaces. Shuttering with plywood panels alone will be permitted. | 1,800 | Sq.m | 700 ₹12,60,000 Lowest | 850 ₹15,30,000 |
| 5.00 | Cleaning the surface of TMT 500D reinforcement of various diameter using wire mesh or equivalent techniques and cement washing using PPC , at all lifts, tools and tackles labour, curing, necessary formwork, transporting, hacking the construction joints complete all as per specifications and as directed by the Engineer-in charge. | 200 | Sq.m | 350 ₹70,000 Lowest | 600 ₹1,20,000 |
| 6.00 | Chemical anchoring of TMT bars Fe500D grade steel reinforcement of dia upto 20mm embedding in RC structures including power drilling holes of appropriate diameter in reinforced or plain cement concrete upto depth minimum 10 times dia of the rebar or as per manufacturer specification, cleaning and filling the hole, fixing the reinforcement in position with RE 500 chemical of HILTI make or equivalent anchoring adhesives and finishing, scaffolding etc all complete as per specification and as directed by Engineer-in-Charge.
Note: 1. Reinforcement will be measured and paid under relevant item. 2. Holes fouling with embedded steel shall be grouted by the contractor at his own cost | 250 | Each | 1,750 ₹4,37,500 Lowest | 1,950 ₹4,87,500 |
| 7.00 | Providing straightening, decoiling wherever necessary bending, cutting, binding and fixing in position steel reinforcement TMT bars of Fe500D grade steel conforming to IS:1786 and tying with approved annealed binding wire of 1.6mm dia in all reinforced cement concrete work at all lifts, including cost of supplying and fixing the spacer/cover blocks and binding wire complete all as per specification and as directed by Engineer-in-Charge at all lifts.
Note: The rate shall be including the cost and testing of reinforcement steel at thrid party NABL lab. The reinforcement steel will be procured from dealers with a test certificate as approved by the department. For further details please see Clause 12 of Section VIII, General Information for Guidance of Tenderers. | 18 | MT | 1,20,000 ₹21,60,000 Lowest | 1,25,000 ₹22,50,000 |
| 8.00 | Providing, supplying, cutting, bending to shape, welding, fabricating, hoisting, placing and fixing in position structural steel members like MS structural embedment’s/Foundation bolts/pipe and sleeves/penetration/sliding gates/chequered plates/ edge angles /Bolts and nuts etc. using MS angles, channels, I-sections, plates, tees, flats, rounds, square sections etc. including chamfering and rounding off the edges, applying a coat of Red lead paint primer / Zinc chromate primer of approved make and 2 coats of synthetic enamel paint of approved colour and make, scaffolding and staging required for fabrication as well as erection complete all as per specifications, drawings and as directed by the Engineer-in-charge.Note: Lifting device arrangements if any required also arranged by the contractor at his own cost. | 10 | MT | 1,40,000 ₹14,00,000 Lowest | 1,50,000 ₹15,00,000 |
Tender Value
₹3.5 Cr
EMD Value
₹7.0 L
Closing Date
23 Feb 2024, 4:00 pmClosed
PROJECT DIRECTOR
Office of the Project Director, FRFCF-NRB, Kalpakkam.
Finishing works in various plant buildings and its associated areas at FRFCF project site, Kalpakkam
2024_BARC_793782_1
NRB/FRFCF/CIVIL/2023-2024/072
Open Tender
Civil Works - Others
Item Rate
366 days
FRFCF, KALPAKKAM
Please Refer Tender Document
8 documents required · 8 mandatory
₹0
₹7.0 L
10 Apr 2024
8 Feb 2024
28 Feb 2024
8 Feb 2024
23 Feb 2024
9 Feb 2024
9 Feb 2024 - 22 Feb 2024
Amount
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 of MoRT&H specifications for road and bridge works (4th Revision) and as directed by the Engineer-in-charge.
for Grading-I material
Dewatering from trenches, sump, foundation structure using electrical submersible or suitable pump of required capasity with necessary arrangements to the nearest storm water drain or at places shown as directed by EIC including HDPE pipe, maintenance of the system, cost of spares, idling, labour for operation etc. Mode of measeurement will be power consumption in KWh. Note: 1. This item will be operated during abnormal bad weather, surface run off from outside scope of work only. 2. Diesel operated pumps shall also be operated as and when directed by the Engineer-in-charge.
Providing and laying cast insitu controlled reinforced cement concrete of specified grade at all levels and lifts mentioned below using 20mm maximum size hard granite machine washed crushed graded stone aggregates and washed crushed stone sand including testings as per QAP, weigh batching, charges for mixing & cost of admixture, mechanical mixing, transporting and placing at all lifts, vibrating, consolidating, 14 days curing and finishing smooth of all exposed faces complete for column footing, columns, lintels, sunshades, gutter slabs, beams, slabs, water tank, machine foundation and all other structural elements including dewatering wherever necessary (Formwork and reinforcement will be paid for separately) all as per specification and all as shown in drawings and as directed by the Engineer-in-charge for all insitu item. Note: 1. The rate of concrete shall include all labour, equipment, charges for mixing & cost of admixture. Polycarboxylate ether (PCE) based chemical admixture confirming to IS 9103 shall be mixed in fresh concrete and prior permission from engineer-in-charge shall be obtained for dosage and compatibility 2. Test certificate of cement, procured from dealer/company to be submitted for all cement related works by the Contractor. 3. The rate shall be quoted on the basis of using minimum cement per cu.m. of concrete mentioned below for relevant grade of concrete. Any upward/ downward variation required to obtain the specified strength will be paid for or deducted at the rate of cement specified in Schedule F.
M30 grade with 380 kg of PPC per cu.m. of concrete for all floors
Supplying, fabricating, erecting and fixing in position at all levels, centering and shuttering to correct line and levels including strutting, propping, etc., with necessary bracings in all axes to give a stable assembly with provision for making the joints in the shuttering fully leak proof and with provision for fixing coil nuts with tie rods along with suitable channel for lateral supports and for inserts, projecting dowels, anchor bolts or any other fixture, including staging, access and working platforms etc., all complete as specified and directed including dismantling and removing the aforesaid assembly after the concrete attains the sufficient strength to self-support itself without cracking and distortion all as per specification, including all materials and labour complete in all respects at all lifts. The measurement for the formwork will be the actual area of forms in contact with concrete surfaces. Shuttering with plywood panels alone will be permitted.
Cleaning the surface of TMT 500D reinforcement of various diameter using wire mesh or equivalent techniques and cement washing using PPC , at all lifts, tools and tackles labour, curing, necessary formwork, transporting, hacking the construction joints complete all as per specifications and as directed by the Engineer-in charge.
Chemical anchoring of TMT bars Fe500D grade steel reinforcement of dia upto 20mm embedding in RC structures including power drilling holes of appropriate diameter in reinforced or plain cement concrete upto depth minimum 10 times dia of the rebar or as per manufacturer specification, cleaning and filling the hole, fixing the reinforcement in position with RE 500 chemical of HILTI make or equivalent anchoring adhesives and finishing, scaffolding etc all complete as per specification and as directed by Engineer-in-Charge. Note: 1. Reinforcement will be measured and paid under relevant item. 2. Holes fouling with embedded steel shall be grouted by the contractor at his own cost
Providing straightening, decoiling wherever necessary bending, cutting, binding and fixing in position steel reinforcement TMT bars of Fe500D grade steel conforming to IS:1786 and tying with approved annealed binding wire of 1.6mm dia in all reinforced cement concrete work at all lifts, including cost of supplying and fixing the spacer/cover blocks and binding wire complete all as per specification and as directed by Engineer-in-Charge at all lifts. Note: The rate shall be including the cost and testing of reinforcement steel at thrid party NABL lab. The reinforcement steel will be procured from dealers with a test certificate as approved by the department. For further details please see Clause 12 of Section VIII, General Information for Guidance of Tenderers.
Providing, supplying, cutting, bending to shape, welding, fabricating, hoisting, placing and fixing in position structural steel members like MS structural embedment’s/Foundation bolts/pipe and sleeves/penetration/sliding gates/chequered plates/ edge angles /Bolts and nuts etc. using MS angles, channels, I-sections, plates, tees, flats, rounds, square sections etc. including chamfering and rounding off the edges, applying a coat of Red lead paint primer / Zinc chromate primer of approved make and 2 coats of synthetic enamel paint of approved colour and make, scaffolding and staging required for fabrication as well as erection complete all as per specifications, drawings and as directed by the Engineer-in-charge.Note: Lifting device arrangements if any required also arranged by the contractor at his own cost.
Supplying, providing and laying 200mm thick Cement Concrete block masonry using solid concrete blocks of size 400 x 200 x 100mm manufactured as per IS : 2185 (Part-1) density not less than 1800 kg/cu.m of grade C 4.0 using 20mm down graded aggregates in basement & superstructure at all elevations in cement mortar 1:5 including mixing mortar, hacking closely concrete surface, laying blocks, raking joints, curing etc., with all materials, scaffolding, labour, tools etc., all complete as per drawings, specifications and as directed by the Engineer-in-charge. Reinforcement if provided will be measured and paid under relevant item.
Providing and constructing 100mm thick precast concrete solid blocks masonry wall in cement mortar 1:4 with solid concrete blocks of size 400x200x100mm Grade C (4.0), manufactured as per IS : 2185 (Part-1): 2005 density not less than 1800Kg/cum. at all Elevation including cost of materials, labour charges, scaffolding, curing complete all as per specifications and as directed by the Engineer-in-charge.
Supplying, providing and fixing approved Anchor fasteners / Cinch anchors of Carbon steel galvanised dash fastner (min 5 micron) of 10mm dia double threaded 6.8 grade counter sunk head screw comprising of polyamide PA 6 grade sleave size 10mm x 150mmat all places including drilling, scaffolding, materials, labours etc., for wall / floor all complete as per drawings, specifications and as directed by the EIC.
10 mm dia
Dismantling brick works at all levels by manually / by mechanical including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead, labour, tools required etc. complete in all respects as per specifications and directed by the Engineer-in-charge.
Dismantling of RCC works at all levels by manually / by mechanical including Cutting and stacking of steel reinforcement bars and disposal of unserviceable materials within 50m lead, labour, tools required etc. complete in all respects as per specifications and directed by the Engineer-in-charge.
Core cutting in RCC structures at given location of specified diameter and different lengths, with rotary drilling, either by pneumatic machines or by electrical machines, at all elevations / positions without disturbing adjacent structures etc., for horizontal and vertical surface all complete as per drawings, specifications and as directed by Engineer-in-charge. Rates to include all labour, tools, tackles, consumables, scaffolding & staging etc.
Upto 200mm diameter
Above 200 mm & upto 300 mm diameter.
Grouting at and around penetrations, construction joints and at all locations as specified in the drawing including necessary scaffolding, drilling holes of specified diameter, supply of grout material, PVC pipe nozzle, fixing, providing all necessary equipment like mixer and pump, manpower etc., all complete required to grout at specified pressure, cutting the pipes after setting of grout, sealing, finishing the surface to achieve required leak-tightness to the satisfaction of the EIC. Only quantity of grout injected shall be measured and paid for. This item is not intended for repair works falling under the scope of contractor for concreting works.
Using Cement based grouting suitable for pumping with addition of approved anti shrinkage compound @ 2% weight of cement with water reducing admixture as required and as directed by the EIC.
Providing plastering to the internal surfaces of brickwork / concrete at all elevations in cement mortar 1:5, 12mm thick including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications.
Providing plastering to the external surfaces of brickwork / blockwork / concrete at all elevations in cement (PPC) mortar 1:4 using washed cruhed stone sand, 20 mm thick in two layers, base layer 12 mm thick and a top layer 8 mm thick finished rough with sponge. including hacking of concrete surfaces with pointed tool, scaffolding, finishing, curing, forming grooves wherever necessary, all as per specifications.
Providing and fixing Gypsum False ceiling Tiles, 600x600x15mm of Armstrong or approved equivalen make, pattern & design in true horizontal level suspended on inter locking metal grid of hot dipped galvanized steel sections (galvanized @ 170 gms/Sqm) consisting of main “T” runner suitable spaced at joints to get required length and of size 24x38mm made from 0.33mm thick (minimum) sheet spaced at 1200mm center to center and cross “T” of size 24x27mm made of 0.33 mm thick (minimum) sheet, 1200mm long spaced between main “T” at 600mm center to center to form a grid of 1200x600mm and secondary cross “T” of length 600mm and size 24x25mm made of 0.33mm thick (minimum) sheet to be interlocked at middle of the 1200x600mm panel to form grids of 600x600mm and laying false ceiling tiles of approved texture in the grid including, wherever, required, cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats fixed to ceiling with 6mm dia and 50mm long dash fasteners, 4 mm GI adjustable rods with galvanized level clips spaced at 1200mm center to center along main T, bottom exposed width of 24mm of all “T” sections shall be pre-painted with polyester paint, all complete at all heights as per specifications drawings and as directed by Engineer in charge.
Providing and laying 50mm thick Indian patent stone flooring and skirting with cement concrete 1:2:4, using 10mm and below size hard broken granite stone jelly including dividing strips, laying in panels, consolidating, curing, rubbing the surface smooth, cleaning the surface neatly at the time of handing over the area complete all as per specifications and as directed by the Engineer.
Providing 50mm thick concrete flooring with metalic concrete hardner topping at all levels and floors consisting of underlayer of 38mm thick cement concrete 1:1:2 (1 part Cement : 1 part Fine aggregate : 2 part Coarse aggregate of 12.5mm and below size) by volume, top layer of 12mm thick 1:2 mix (1 part cement with metallic hardener of Hardonate / Ironite or approved equivalent : 2 parts of stone aggregate of 6mm nominal size by volume) (metallic hardener and cement mixed ratio is 1:4) prepared as per manufacturer's instructions including chipping the concrete surface, finishing, curing, providing aluminium dividing strips, cleaning the surface neatly at the time of handing over the area etc. complete all as per specifications and drawings.
Providing and laying approved quality mirror polished Granite slabs for flooring & Skirting of required size & specified colour, pattem and free from cracks, fissures & flakes with straight edges & perfect corners laid at right angles as per pattern over a bedding of cement mortar 1:4, 20mm thick (or backing of cement mortar 1:3, 12mm thick as mentioned below) pointed neatly with white cement mixed with coloring pigment to match colour of slab and finished in all respects, including machine / hand cutting to required size and shape, moulding and polishing of exposed edges, fixing stone to level and plumb, anti-skid grooves for steps, curing, cleaning the surface neatly at the time of handing over the area, all materials and labour complete. Note: The sample Granite slab shall be got approved by the Architect/Engineer before procurement.
In flooring 18mm thick Granite slab fixing with 20mm thick bedding in cement mortar 1:4
In steps/step thread, 18mm thick Granite slab with anti skid grooves of required pattering & moulding and polishing of exposed edges, fixing with 20mm thick bedding in cement mortar 1:4. The granite slab shall be single length to match step length.
Supplying and laying approved quality Polished Vitrified floor tiles of size (600mmx600mm or 300x300 size) 9 to 10mm thick Kajaria/ Asian/ Nitco or approved equivalent conforming to IS 15622 first quality in pattern / combination as shown in drawing,over 40mm thick bed of cement mortar 1:4, to achieve total final floor finish of 50mm thickness, jointed with neat cement slurry mixd with pigment to match the shade of tiles including all materials, labour, tool etc., complete all as per schedule drawings / specification and as directed by EIC. Note: Sample shall be submitted and got approved by EIC before procurement.
Providing and fixing VITRIFIED floor tiles in different sizes with water absorption less that 0.08% and confirming to IS 15622 of Marbonite or approved make in all colours and shades in Glossy or Matt or satin finish (as required by Engineer-in-charge) laid over a bed of minimum 20mm thick bed of cement mortar 1:4 (IN Skirting, risers of steps and dados over 12mm thick bd of cement mortar 1:3) including machine/hand cutting to required size & SHape, grouting the joints with white cement mixed with coloring pigment to match colour of tile patterns, curing, cleaning the surface neatly at the time of handing over the area complete all as per drawings and specifications. Note: The sample tile shall be got approved by the Architect/Engineer before procurement.
In Dados and skirting laid over 12mm thick backing in cement mortar 1:3
Providing F3 finish over concrete surface in cement mortar 1:1.5 (1 part cement : 1.5 part fine sand) including wetting the surface, labours, curing, all materials, scaffolding, at all elevations complete all as per specification and as directed by the Engineer-in-charge.
Providing and applying painting Two coats at all levels with Interior grade Acrylic emulsion paint (approved brand, colour and manufacturer) confirming IS : 5411 Part I & II at all elevation to give an even shade including one under coat of suitable primer, applying putty, preparation of the surfaces, grinding, removing laitance, cement slurry, formoil, foreign matter etc., scaffolding complete all as per specifications and as directed by the Engineer-in-charge. Note: Rate includes filling all voids/pinholes in concrete by cement mortar touch up work / minor plastering.
Providing and applying painting Two coats at all levels with Exterior grade Acrylic emulsion paint (approved brand, colour and manufacturer) confirming IS : 5411 Part I & II at all elevation to give an even shade including one under coat of suitable primer, applying putty, preparation of the surfaces grinding,removing laitance,cement slurry ,formoil, foreign matter etc., scaffolding complete all as per specifications and as directed by the Engineer-in-charge. Note: Rate includes filling all voids/pinholes in concrete by cement mortar touch up work / minor plastering.
Supply and application of 2 or 4 coats of Epoxy paint from approved manufacturer & approved shade and approved colour to interior walls, columns, beams, ceiling gantry platform and as indicated in the drawings upto 24m elevation, including scaffolding, staging and approch ladder etc., including preparation of the surface to be painted, by surface grinding, removing laitance, cement slurry, formoil, foreign matter, open voids, water cleaning, protecting the plate EP's, pipe EP's, closed steel boxes, edge angles with masking tape, applying primer coat, one coat of putty mixed with epoxy, filling all voids/pinholes in concrete by approved wall putty mixed with epoxy, removal of roughness in plastered surface with one or two coat of putty, applying epoxypaint by airless spray gun or roller brush with necessary ventilaton system, exhaust fans for proper release of gas, all materials, tools - tackles, equipment, materials, labour, necessary cleaning equipment, etc,. all complete as per manufacturer specification at all elevations and directed by the EIC. Note: Rate includes following 1. Two or more shade with 250 or 500 micron thickness shall be envisaged in a single wall. 2. Wetfilm thickness and Dry film thickness shall be checked at frequent intervals and as per QA requirements. 3. Rate shall also include preparation of concrete/ wall surface by breaking (if required), chipping, surface grinding and making the concrete surface smooth by cement mortar touch up work / minor plastering as indicated by EIC. 4. Painting in confined areas also envisaged in this item. Embedments / equipments available in the room shall be protected with masking tape or by alternate arrangements.
250 microns Elevation upto 10m height
500 microns Elevation upto 10m height
Providing and Fixing Homogeneous PVC sheet, 2.2mm thick, conforming to IS: 3462 latest edition in flooring and skirting (LG Emenite or approved equivalent make) in approved pattern, colour & shade on a smooth and damp proof base using rubber based adhesive of approved quality and manufacturer like Duniop-S - 758, or Fevicol SR 998, or approved equivalent including cleaning & preparation of surface, levelling small undulations with plaster of paris if required, rolling with light wooden roller weighing about 5 kg all complete all as per specification and as directed by the Engineer-in-charge. Note: The sample tile shall be got approved by the Architect/Engineer before procurement.
Providing and fixing anodized aluminium (Anodised transparent or dyed to required shade according to IS:1868 Minimum Anodic coating of grade AC 15) work for doors, windows, ventilators and partitions,louvers with extruded built up standard tubular sections / Z Sections and other sections of approved make confirming to IS:733 and IS:1285 fixed with rawl plugs and screws or with fixing clips or with expansion hold fastners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC / neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P brass / stainless screws all complete as per architectural drawings and and directions of Engineer-in-charge including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required. (fittings, Glazing and panelling shall be paid for separately)
Providing and fixing IS: 3564 marked AI die cast body tubular type universal hydraulic door closer with necessary accessories and screws etc. in wooden doors / steel doors with necessary bolts & nuts "Everite Hardwyn" or approved equivalent make complete as per specification and as directed by the Engineer-in-charge.
Providing and fixing bright finished brass tower bolts (barrel type) of size 200 x 10mm with necessary brass screws etc. complete all as per specifications and as directed by the Engineer-in-charge.
Providing and fixing Stainless steel "C" type Door handles 10mm dia SS 304 Grade solid Rod, 150mm long in Steel Doors / wooden Doors including SS screws / bolts etc. all as per drawings and specifications complete. Sample to be approved by the Engineer-in-charge.
Providing and fixing glazing 6mm thick tinted colour Float glass pane in aluminium doors, windows, ventilator shutters and partitions etc. with Neoprene gasket including cost of neoprene gasket complete as per the drawings and directions of the Engineer-in-charge.
Providing and fixing double action floor spring of 'Hardwin' or approved brand and manufacturer (confirming to IS: 6315) for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece of M.S. Sheet outer box with slide plate etc. complete as per directions of Engineer-in-charge with brass cover plate.
Providing and fixing 12mm thick prelaminated with decorative lamination on both side, 3 layer medium density (Exterior grade) particle board Grade-1, Type - II confirming to IS: 12823 bonded with phenot formaldhyde synthetic resin of approved brand and manufacture in panelling fixed in aluminium doors, window shutters and partition frames with C.P. brass / stainless screws etc. complete as per drawings and as directed by Engineer-in-charge.
Providing and fixing AI hanging Heavy Quality floor door stopper ISI marked with Twin Rubber stoppers, anodised (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to req. colour or shade with necessary screws etc. complete all as per specification and as directed by the Engineer-in-charge. Sample to be approved by the Engineer-in-charge.
Providing and fixing Multipurpose lock 'Godrej' or other approved equivalent make with a pair of keys complete all as per specification and as directed by the Engineer-in-charge.
Providing and fixing roofing sheet, cladding with 0.47mm thick colour coated concelled system profile corrugated/semi corrugated/plain zincalume sheets of 55mpa yield stress (AS 1397 - Zincalume AZ 150) with coating class AS/NZS 2728 (minimum 150 grams per relevant standard) having a total coating thickness of 35 micron. The sheet should be rolled over specially designed concealed fixing clip manufactred from hi-tensile Aluminium Zinc alloy Zincalumen steel based and galvanized hooks. The clip should be fastened with minimum 40micron Zinc coated / minium 25micron Zinc-Tin alloy coated. The rate is inclusive of all fixtures required for fixing the side roof, cladding on all sides, ridges etc. complete all as
Supply and installation of following sizes of Heavy Duty, Hot Dip Galvanised MS ERW Conduits for Electrical & Communication System with all the required accessories like round JBs, Solid Long Bends, Check Nuts, Nipples, Couplings, Reducers, Copper Clips, Copper Conductor, GI Wire etc, on roof slab, column, beams etc as per the detailed specification.
25 mm Dia 1.8mm, wall thickness GI Heavy Duty ERW Conduits with 75mm deep junction boxes
50 mm Dia 2mm, wall thickness Heavy Duty ERW Conduits with 75mm deep junction boxes from DB to Pull box
Supply and embedment of concealed type Hot dip galvanised MS boxes of the following sizes in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification.
150(W)X150(H)X80(D)mm, 1.8mm thick sheet Hot dip galvanised MS box
400(W)X300(H)X200(D)mm, 2.0 mm thick sheet Hot dip galvanised MS box
Supply and Embedment of 50mm Deep,Square/Rectangular Concealed type and GI double earthed modular metal boxes of the following types and as specified in RCC/Brick/Concrete Block Masonry with finishing and making good as per the detailed specification.
1/2 Module SB
3 Module SB
12 Module SB
Supply, installation and end termination of the 185 Sq.mm tinned, stranded copper conductor embedded in the PCC floors/ RCC floors/ RCC columns and beams/ RCC / Brick Masonry walls etc., installation as per the scope of work,drawings and as directed by the Engineer-In-Charge.
Supply and installation of the 8 SWG solid copper conductor embedded in the PCC floors/ RCC floors/ RCC columns and beams/ RCC / Brick Masonry walls etc., complete with all accessories required for terminating one end in the grounding pads and the other end in terminating one end in the grounding pads and the other end in the equipment body as per the scope of work and as directed by the Engineer-In-Charge..
Supply and installation of the following size of tinned copper grounding pads embedded in the Cement floors, RCC / Brick Masonry walls/floors/columns/beams/ceiling etc., as per the scope of work, drawings and as directed by the Engineer-In-Charge: 65 x 65 x 4 mm tinned copper grounding pads
Jointing of 185 Sq.mm tinned, stranded copper conductor by exothermic welding (CAD welding) of the Straight type Joint complete with all components and accessories as per the scope of work ,drawings and as directed by the Engineer-In-Charge.
Jointing of 185 Sq.mm tinned stranded copper conductor with 65 x 65 x 4 mm tinned solid copper floor/wall/column/ceiling grounding pads as per the scope of work ,drawings and as directed by the Engineer-In-Charge.
Supply and fixing of the following front modular plates of various modules made out of engineering plastic of adequate thickness and with standard dimensions suitable for fixing in flush with the standard sizes of modular metal switch boxes for installing the standard modules of light/fan switches and power sockets, complete with all accessories as per the technical specifications and as directed by the Engineer-In-Charge.
1M Front Plate
2M Front Plate
3M Front Plate
12M Front Plate
Supply, fixing, testing and commissioning of the following modular type switches, sockets, plug tops, fan regulators in the standard front modular plates as per the technical specifications and as directed by the Engineer-In-Charge..
1 No. 10 Amps 1 way SP switch
1 No. 16 Amps 1 way SP switch
1 No.6 Amps 3 pin shuttered socket with plug
1 No. 6/16 Amps combined 3 pin shuttered socket with plug
Supply and installation Wiring for lights / fans /sensors/ Power point with 1100V grade FRLS insulated copper conductor wires in existing concealed/ Exposed PVC / ERW / Flo-coated Metal conduits as per the detailed scope of work, including supply of Wires, termination of copper wires at either end by crimping including supply of PVC Sleeves/Ferrules, Copper Crimping Lugs and connecting the wires to various switches, sockets, etc. including testing and commissioning as per the detailed specification.(Refer Sec VI, Clause No.18)
Wiring with 1 Run of 1.5 Sq.mm Copper wire
Wiring with 1 Run of 2.5 Sq.mm Copper wire
Wiring with 1 Run of 4 Sq.mm Copper wire
Supply of Office Area luminaries: Supply of the recessed mounted type industrial LED luminaries with CCT of 6500K, having a minimum CRI of 80, lumen output of minimum 3600, minimum lumen efficiency of 110 lm/w, ingress protection min of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminum housing, etc., with a suitable current control driver circuit and complete with all accessories as per specification and as per the instruction of EIC.
Installation of Office Area luminaries: Installation, testing and commissioning of the recessed mounted type Office Area industrial LED luminaries with necessary mounting arrangements required to suspended from 5 meter ceiling and connection for 2.5 sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
Supply of Wall mounted luminaries: Supply of the recessed mounted type industrial LED luminaries with CCT of 6500K, having a minimum CRI of 80, lumen output of minimum 2000, minimum lumen efficiency of 110 lm/w, ingress protection min of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminum housing, etc., with a suitable current control driver circuit and complete with all accessories as per specification and as per the instruction of EIC.
Installation of Wall mounted luminaries: Installation, testing and commissioning of the wall mounted LED industrial type luminaries with necessary mounting arrangements required to to mount on wall and connection for 2.5 sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
Supply of Wall mounted/Suspended type luminaries: Supply of energy-efficient Wall mounted /Suspended with reflector industrial LED luminaries with CCT of 6500K, having a minimum CRI of 80, lumen output of minimum 4000, minimum lumen efficiency of 110 lm/w, ingress protection min of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminum housing, etc., with a suitable current control driver circuit and complete with all accessories as per specification and as per the instruction of EIC.
Installation of Wall mounted/Suspended type luminaries: Installation, testing and commissioning of energy-efficient Wall mounted /Suspended industrial LED luminaries with necessary mounting arrangements required to to mount on wall with provision and connection for 2.5 sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
Supply of Medium bay luminaries: Supply of energy-efficient medium bay industrial type LED luminaries of suspended type with CCT of 6500K, having a minimum CRI of 80, lumen output of minimum 9200, minimum lumen efficiency of 110 lm/w, ingress protection min of IP20, and impact resistance of min IK-05 having THD of less than 10% in pressure die-cast aluminum housing, etc., with a suitable current control driver circuit and complete with all accessories including mounting arrangements maetrial to suspend a fitting from a 9 meter medium bay with provision and connection for 4 sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
Installation of Medium bay luminaries: Installation, testing, and commissioning of energy-efficient medium bay industrial type LED luminaries of suspended type and complete with all accessories including mounting arrangements required to suspend a fitting from a 9 meter medium bay and connection for 4 sq. mm flexible copper conductor of PVC insulation wire, etc., as per specification and as per the instruction of EIC.
Supply and Installation of MS Brackets, Supports, Frame work, Clamps, Base Channels, etc. fabricated out of angle / Channel / Rods etc. The rate quoted shall include the cost of fabrication / welding, cleaning and painting/galvanising as follows including supply of required, fasteners, nuts, washers, etc. (Refer Sec VI, Clause No.11).
MS fabrication 1 coat primer & 2 coats synthetic enamel paint
Supply & laying of 1 pair, 1.5 sq.mm Stranded copper conductor, flexible un-armoured cable, insulated Class-A, FRLS cable for FDAS
Supply & laying of 1 Pair, 1.5 sq mm Stranded copper conductor, flexible un-armoured cable, FRLS PVC sheath, insulated cores, twisted pair, Overall screened with Al-Mylar tape, voltage grade 1100V, applicable standard IS 1554 for PA system
Supply & Laying of CAT-6 UTP Cable through embedded conduit / cassing-capping for Telephone system, CCTV System and LAN System
SAKTHI ENGINEERS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.10 MB
BOQ_834299.xls
BOQ • 0.30 MB
2023forms072.xls
Additional Documents • 0.12 MB
GCC2014.pdf
Additional Documents • 4.88 MB
ElectricalandInstrumentation072.pdf
Additional Documents • 6.21 MB
TenderDocumentCivil072.pdf
Tender Documents • 4.44 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .