supply installation testing and commissioning of LED lights High Mast Flood Lighting System
2022_SICOP_160394_1
07aa-SICOP (PME) of 2021-22 Dated 12-02-2022
Open Tender
Electrical Goods/Equipments
Item Rate
365 days
Sanat Ghar Bemina
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
PME
Exempted
28 Feb 2022
12 Feb 2022
22 Feb 2022
12 Feb 2022
21 Feb 2022
12 Feb 2022
Amount
Providing supply, installation, testing and commissioning of 50hz, outdoor type, delta star, aluminum wound, ONAN cooled, distribution transformer, confirming to is: 2026-1977 with latest amendments dully tested, painted and oil filled to is: 335 of 1983 with latest amendments the transformer shall be complete with following: - A) oil conservator with oil level indicator, minimum level marking and drain plugs, B) top mounted ht bushings with arcing horn. C) LT bush enclosure. D) lifting lugs and bi-directional roller E) rating diagram and terminal marking plate F) explosion vent and valves for filtration, drainage and filling e. With necessary plugs, including air release plug a). 100 KVA, 11/0 433kv
b) 200 KVA, 11/0 433kv
c).250 KVA, 11/0 433kv
b). Rating 25 KVA
c). Rating 30 KVA
d). Rating 35 KVA
e). Rating 50 KVA
f). Rating 100 KVA
g). Rating 200 KVA
h). Rating 250 KVA
Providing supply,installation, testing and commissioningof 35 mm sq 11 kv grade, 3 core aluminum conductor abc cable , XLPE insulated with aluminum alloy messenger wire for carrying the weight of the cable of maximum system voltage of 12 kv ( Havells / PolycablSkytone/ Gloster make),the cable should be anchored on the poles using suitable galvanized hooks. If substation capacity is enhanced to 250 kva 50 mm cable amount will be enhanced
Outdoor endkiits heat shrink type for above 35 mm sq 11 KV Three core abc cable type
ST poles 9_Mtr Long complete with Base Plate and top cap Confirming to IS 410 SP 33 to be erected in cement concrete 1:3:6 (1 cement 1 3 coarse sand: 6 graded stone aggregate 40 mm nominal size) foundation including excavation,refilling, formwork etc as required at site.
11 KV GOD for tapping points and substation
11 KV Lightening Arrestor. The arrestor should be station type and of 10 KA rating including clamps of appropriate size.
11 KV Drop out fuse / Arcing horn gap
Providing of chemical earthing
1OOX50X5OX6 NIS channeis,8.5 feet long including cutting, fabrication and installation on ST poles for Distribution Transformer (DTR) frame to be erected as per REC guidelines using GI clamps.
Supplying laying testing and commissioning of additional copper piping, 6.35mm, 0.8mm thick with 13mm insulation
45x45x5MS angle iron 8.5 feet long including cutting,fabrication and installation forbelt for transformer
Fabricated clamps of 50x5mm GI strip for erection of DTR channels etc.
Supply, Testing and commissioning of HT meter
35 mm sq core XLPE armored aluminumconductor 11 KV cable of maximumsystem voltage of 12 kv (Havells/Poly cab Paramount / Sky tone make)
Supplying and laying of 32mm PPR pipe with allied accessories for drain use complete as required
185 mm sq Aluminum armored XLPEthree and a half core LT cable 1.1 KV grade ofHavelles,Polycabl, Paramount , SkytoneKEI make
3 inch dia 2.5 inch dia A class GI pipe for use as conduit for XLPE cable for DTR as required at site
Making of G.I pipe earthings using 2” dia 8 feet long GI pipe with 12”x12” cast iron manhole cover fixed in requisite masonry work
Making of plate earthing (Copper plate 2’x2’) including 25x3mm GI earth riser strips for DG and GI masts
Cement Concrete Foundation using M15 for servo 8’x6’x4’ size and for DG set 6’x5’x4’ size (or size as specified by DG manufacturer for DG only) with 3 inch slab and plastering complete including form work etc.
Supply Installation, testing and commissioning of sports LED Flood Light canis lens type designed for outdoor Sports Lighting applications having Housing of Pressure Die Cast aluminum construction with thermal management heat sink design, Flood light Cover shall be of toughened optically clear glass construction mounted in a metal frame with silicon gasket for IP protection. LED flood Light and driver enclosure IP protection IP 65 minimum. Flood light should be equipped = with Cradle type epoxy powder coated adjustable MS flood light bracket suitable for mounting on Sports lighting tower. (For detailed LED Fixture Specification please refer to SBD of this tender); LED Fixture makes: APEX LED Flood light Osram LED Flood light , LOKOZO LED Floodlight WIPRO LED floodlight GOLDWYNLED/Philips Flood Light Surya or equivalent 200 watts
250 watts
400 watts
500 watts
1000 watts
Supply Installation,testing and commissioning of 30 m high galvanized polygon tubular Sports Lighting Tower 8.0mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel tube construction for mounting of 10 nos. to 20 no’sSports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED color type. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports Lighting Tower manufacturer to be submitted for approval before starting of the foundation works)
Supply Installation,testing and commissioning of 30 m high galvanized polygon tubular Sports Lighting Tower 8.0mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel tube construction for mounting of 20 nos. to 30 no’sSports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED colour type. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports Lighting Tower manufacturer to be submitted for approval before starting of the foundation works)
Supply Installation,testing and commissioning of 30 m high galvanized polygon tubular Sports Lighting Tower 10.0mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel tube construction for mounting of 30 nos. to 54 no’sSports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED colour type. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports Lighting Tower manufacturer to be submitted for approval before starting of the foundation works)
Supply Installation , testing and commissioning of 24 m high galvanized polygon tubular Sports Lighting Tower 8.0mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel tube construction for mounting of 10 nos. to 20nos Sports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED color type. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports Lighting Tower manufacturer to be submitted for approval before starting of the foundation works)
Supply Installation , testing and commissioning of 20 m high galvanized polygon tubular Sports Lighting Tower 8.0mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel tube construction for mounting of 10 nos. to 20 no’sSports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED color type along with feeder pillar. Drawings for GA of the S orts _Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports Lighting Tower manufacturer to be submitted for approval before starting of the foundation works)
Supply Installation,testing and commissioning of 20 m high galvanized polygon tubular Sports Lighting Tower 8.0mm thick with max. 3 sections, 20 sided polygon, of S355 Grade as per BSEN 10025, galvanization as per BS EN ISO 1461, designed as per IS 875 part Ill, poles as per BS EN ISO 1461, c/w Head frame of GI Channel tube construction for mounting of 20 nos. to 30 no’sSports flood lights, c/w Single gear double drum (SGDD ) winch min, load of SWL 750 kgs, heavy duty motor with mechanical tripping facility, electrical Cable of EPR insulated, weather proof IP65 Junction box, SS 316 grade wire rope, lightening protection, LED twin aviation obstruction light of low intensity continuous burning RED color type along with feeder pillar. Drawings for GA of the S orts Lighting tower and Foundation details to be enclosed with the Tender Bi For foundation calculation 10 SBC of SBC of 10 Mt to be considered ( It is the responsibility of the contractor executing the works to arrange for soil testing and SBC reports of ground conditions each sports lighting tower foundation location and revised foundation drawing from the Sports Lighting Tower manufacturer to be submitted for approval before starting of the foundation works)
Foundations of 30Mtr high mast poles. Contractor to furnish SBC report and foundation design for approval)
Foundations of 24Mtr high mast poles. Contractor to furnish SBC report and foundation design for approval)
Foundations of 20Mtr high mast poles. Contractor to furnish SBC report and foundation design for approval)
Ferruling
Galvanized nuts and bolts of sorts as required at site
Earthing of 9 Mtr. Long ST poles using 8 SWG GI Wire
0.03 ACSR for jump ring of transformer on HT side
Aluminum Thimbles of sizes required for cables of different sizes used including crimping
25x3 mm GI strip for earthing extensions
Epoxy insulator of sizes required for earthing of DTR structure
12”x9” Danger plates for HT and LT notification
Painting of DTR frame and tapping point frame with two coats of red oxide and two coats of aluminum paint
Supply erection testing and commissioning of 70mm Sq aluminum conductor, armored XPLE three and a half core LT cable 1.1 KV grade of Havells, Polycabl, Paramount, Sky tone make
50mm Sq Aluminum conductor, armored XLPE thee and a half core LT cable 1.1 KV grade of Havells, Polycab Paramount, Skytone make
25 mm sq Aluminum 3 cores LT cable 1.1 KV grade of Havells, Polycab, Paramount, Skytone Make
Trench for cable laying through 3” HDPE pipe including excavation laying of sand bed placing of layer of bricks (cost of sand and bricks included) including metallic cable markers with grouting after every ten meters. The cable route marker should be of 45x45 angle iron 2.5 feet long with circular metallic disc 4” dia at the top with LT CABLE embossed on it. The route marker should be grouted 1 feet inside the concrete and 1.5 feet above ground with clearly legible marking
Supply & installation of 3,4mm thick octagonal high mast having bottom dia of 300mm and top dia of 100mm thick. 12Mtr high.
Supply & installation of 6,4mm thick octagonal high mast having bottom dia of 360mm and top dia of 150mm thick 14Mtr high.
Supply & installation of 6,4mm thick octagonal high mast having bottom dia of 360mm and top dia of 150mm thick 16Mtr high.
Foundation work for high mast inlc. GI Anchor bolts, anchor plates, double nuts, washers a)For 12Mtr.
b)For 14Mtr.
c)For 16Mtr.
Supplying and fixing of special arm suitable for mounting Led Flood Lights for 12Mtr high masts.
a). Sub Main LT Panel Outdoor type
b). P/f of 6-32 Amp. MCB complete with connections as req.
c). P/f of 4-pole connector 16 amp complete with connections as req.
Supplying, installation, Testing & Commissioning of 2.5x2C Copper flexible wire of approved made
Supplying/laying HDPE pipe
Supplying and fixing of GI Wire (8SWG)
P/Laying of armored aluminum conductor to be laid in already excavated cable trench. The job incl. refilling after cable laying and removal/disposal of surplus earth. a). 10mm 4 core armored aluminum conductor
b). 16mm 4 core armored aluminum conductor
c). 25mm 3.5 core armored aluminum conductor
d). 25mm 4 core armored aluminum conductor
e). 35mm 4 core armored aluminum conductor
f). 50mm 3.5 core armored aluminum conductor
g). 70mm 4 core armored aluminum conductor
Fabrication, Supply & Installation of outdoor Canopy suitable for main panel board and Servo Stabilizer with complete cement concrete foundation and locking arrangement complete job.
High Must AC street light with S.T Pole (6 lights - 50 W each) Luminary – LED 50 Watt each Pole - 9 meter length (Tabular pole with cement bottoming in ratio of 1:3:6 mix with 2x2x2.5) including nut bolts and other accessories
M/S M.Z ENTERPRISES
VALLEY ELECTRICAL INDUSTRIES
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .