PROVN OF QTY03 PAC OF 10 TON CAPACITY AT DIPAC UNDER GE(U) P AND M DELHI CANTT-10
2026_MES_796373_1
CWE(U)/D-20/2026-27
Open Tender
Civil Works
Works
180 days
HQ CWE (U) Delhi Cantt-110010
As per Tender Pages
9 documents required · 9 mandatory
₹1,000
GE (U) P and M
₹1.3 L
Yes
29 Oct 2026
29 Oct 2026
2 Dec 2026
29 Oct 2026
25 Nov 2026
19 Nov 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply, installation & commissioning and testing including lifting & shifting floor Mounted, Bottom/Frontal discharge, Air Cooled DX type CRAC units for server room application, equiped with most advanced technology, guaranteeing precise control of Data Centres and server room. The units shall be selected on the basis of following parameters:
i) 33 kW of minimum nominal Cooling Capacity @ 10000 CMH
ii) 28 Deg C / 36% RH of return air
iii) Supply air in between 15 - 18 Deg C
iv) 45 Deg C of Design Ambient temperature
v) Specific Power consumption shall be low as per site design conditions including compressor, evaporator fans and condensers.
The Indoor unit shall comprise of Digital Scroll Compressor, Fibreglass corrossion resistant EC fans, Evaporator DX Cooling Coil with hydrophilic coating, Microprocessor controllers, TXV, Driers, G4 Filter, Suction and Discharge piping, Internal power and Control wiring, Crankcase heaters, Infrared Humidifier, Heaters, HP/LP Cutouts, Power and Control contactors, water leak detectors and Other Electrical accessories.
The Outdoor Condenser unit shall comprise of Condenser fans & motor, Condenser cooling coil (Copper coil with aluminium fins), Fan speed controller, Isolater switch.
vi) The system should be engineered for continuous 24/7/365 operation with high energy efficiency and tight tolerance limit. | 3 | Each Job | - | - |
| 1.01 | vii) Control accuracy: Temp control within +1⁰C and relative humidity control within +5% RH.
NOTES:- The unit shall be suitable for operation on 415 Volts, 50 Hz, 3 Phase, 4 Wire AC supply. Each unit should be having individual display panel, which shall display date, time, actual & set values, operating conditions, signal faults, collective faults, limiting values and PAC wellness alarm / service alarm to reduce the down time and unit memory shall hold the 400 most recent events with ID number, time and date stamp for each event The dimensions of the unit shall not be more than 900 mm x 900mm x 1970mm (L x D x H). Team Mode feature for PAC units controller for synchronising the Multiple No. of units to work as single system for all above units.
Load sharing mode feature
Cascading Effect
Sequencing of above Units | - | - | - | - |
| 2 | Supply and fixing of Indoor Unit stand duly painted with anti-corrosive paint along with vibration pads, fittings and accessories complete all as specified and as directed | 3 | Each | - | - |
| 3 | Suppy and fixing Outdoor Unit Stand - Choki type duly painted with anti-corrosive paint along with vibration pads, fittings and accessories complete all as specified and as directed | 3 | Each | - | - |
| 4 | Material and Labour for Initial charge of R-410a refrigerant gas & oil complete all as specified and as directed | 100 | KG | - | - |
| 5 | Supply and fixing of Interconnecting Copper piping for hot gas line between indoor & outdoor unit with all fittings and accessories.@20 RMT per machine complete all as specified and as directed | 45 | RM | - | - |
| 6 | -Ditto- all as per Ser Item No 5 here-in-before but for liquid line | 45 | RM | - | - |
| 7 | Supply & fixing of Interconnecting copper cabling of size 3Core x 2.5 sqmm between indoor & outdoor unit along with cable tray complete all as specified and as directed | 55 | RM | - | - |
| 8 | Supply & fixing of Incoming copper cabling of size 4C x 10 sqmm from Incoming isolator to CRAC Unit (@5RM/Unit) complete all as specified and directed. | 15 | RM | - | - |
| 9 | Supply & Fixing of condensate drain piping with CPVC pipes (@5RM/Unit) complete all as specified and directed. | 15 | RM | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.35 MB
D20TP.pdf
Tender Documents • 1.22 MB
BOQ_893233.xls
BOQ • 1.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .