Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.7 LAccepted-AOC | L1 | Accepted-AOC Reasonable | |
| 2 | L2₹26.6 L+₹4,362.50 (0.16%)Rejected-Finance | L2 | Rejected-Finance High rate | |
| 3 | L3₹30.2 L+₹3.6 L (13.6%)Rejected-Finance | L3 | Rejected-Finance High rate | |
| 4 | L4₹42.3 L+₹15.8 L (59.5%)Rejected-Finance | L4 | Rejected-Finance High rate | |
| 5 | L5₹45.8 L+₹19.3 L (72.6%)Rejected-Finance | L5 | Rejected-Finance High rate |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
12 Oct 2024, 6:00 pmClosed
GE KHADAKWASLA
GE KHADAKWASLA
REPAIR MAINT OF STANDBY DG SETS INSTALLED AT VARIOUS LOCATIONS UNDER AGE EM I NDA KHADAKWASLA
2024_MES_676159_1
8869/E8
Open Tender
Civil Works
Item Rate
330 days
GE KHADAKWASLA
All as per tender documents
9 documents required · 9 mandatory
₹500
GE KHADAKWASLA
₹96,000
Yes
26 Nov 2024
23 Sept 2024
17 Oct 2024
23 Sept 2024
12 Oct 2024
7 Oct 2024
23 Sept 2024 - 7 Oct 2024
Amount
M&L for monthly Inspection, maintenance and serviceing of DG sets of the following capacities including alternator, electric panel board connection to DG set for routine check (A check) of DG set for smooth functioning and carrying out maintanance as directed. Monthly Service : A Check : (a) Checking engine oil level and topping up as and when required . Note : Oil shall be measures and paid separately. (b) Checking and adjusting the belt for tension and replacement of belt. Note : Belt shall be measured and paid seperately. (c) Checking of oil bath air cleaner level. (d) Checking of exhaust system for leakage (e) Draining of sediment from fuel filter and fuel tank (f) Cleaning of air cleaner element (g) Checking engine alternator coupling, mounting bolts and alignment (h) Tighting all nuts, bolts, in altenator terminal block (j) Checking of alternator carbon brush and connections in alternator (k) Checking and tighting of all connection in DC control wiring. (l) Checking of all radiator rubber hose and replacement if required. Note : Hose pipe shall be measured and paid separately (m) Checking and recording oil pressure, water and oil temperarute (n) Checking anti vibration mounting and replacement if required. Note : Anti vibration pad shall be measured and paid separately (o) Checking throttle linkage (p) Checking battery for cell test, electrolyte level, gravity and topping up to required level (q) Routine check / repair work of panel, switch, MCCB, main switch, all contactors, engine control unit. (r) Checking of AMF panel, all electrical connections etc. (s) Checking of earthing resistance (t) Cleaning of vegitation around the DG set up to 1.5 mtr area. (i) 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 , Location : Power House (Total 02 Nos)
Ditto all as per item No. 1 above but 320 KVA Capacity, Make : Cromption Greaves, 318/6002-DG/08, Location : Manoj Pandey Bldg
Ditto all as per item No.1 above but 320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14, Location : Vyas Library
Ditto all as per item No. 1 above but 200 KVA Capacity, Make : Cromption Greaves, 207406, Location : 'A' Sub Stn
Ditto all as per item No. 1 above but 200 KVA Capacity, Make : Cromption Greaves, 318/6003-DG/08, Location : ATT
Ditto all as per item No. 1 above but 160 KVA capacity, Make : Kirloskar, 318/6008/DG/2011 , Location : MH Khadakwasla
Ditto all as per item No. 1 above but 125 KVA Capacity, Make : Kirlosakar,318/6076/DG/13, Location : NDA Area (Trolley Mounted)
Ditto all as per item No. 1 above but 82.5 KVA Capacity, Make : Kirloskar, 318/6006/DG/11, Location : VIP AREA
Ditto all as per item No.1 above but 62.5 KVA Capacity, Make : Crompton Greaves, 318/6009/DG/13, Location : Power Houser (MIS Cell)
Ditto all as per item No.1 above but 50 KVA Capacity, Make : Kirloskar, 318/6015/DG/2011, Location : New Pashan Gate / Trishakti gate
Ditto all as per item No.1 above but 50 KVA Capacity, Make : Cromption Greaves , 207405, Location : GE office, AGE E/M office
Ditto all as per item No.1 above but 50 KVA Capacity, Make : Cummins, 318/6001-DG/04, Location : AFTT
Ditto all as per item No.1 above but 50 KVA Capacity, Make : Kirloskar, 318/6054/ACT/15, Location : AFTT (Addl Hanger)
Ditto all as per item No.1 above but 25 KVA Capacity, Make :Kirloskar, Location : AFTT (HRDF)
Ditto all as per item No.1 above but 5 KVA Capacity, Make :Cromption Greavesr, Location :Tower 6
Ditto all as per item No.1 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 10
Ditto all as per item No.1 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 11
Ditto all as per item No.1 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 16
B' Check once in Six month OR 250 Hrs running of DG set whichever is Earlier : Material and labour required for inspection, maintenance, servicing of DG sets of following capacities, including items covered in B check of DG set for smooth functioning and carrying out maintenance complete as per OEM instruction and as directed :- (a) Repeat the activities of 'Á' Check (b) Replacment of of lubricant oil. (Note:- Lub Oil are Paid separately.) (c) Replacing lubricant oil filter element with 'O' ring (d) Replacing fuel filter element (e) Replacing coolant. (f) Replacing Governer oil. Notes : B Check kit, coolent shall and Lubricant oil shall be measured and paid separately under relevent items. 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 ,Location : Power House (Total 02 Nos).
Ditto all as per item No. 19 above but 320 KVA Capacity, Make :Cromption Greaves, 318/6002-DG/08, Location : Manoj Pandey Bldg
Ditto all as per item No.19 above but 320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14, Location : Vyas Library
Ditto all as per item No.19 above but 200 KVA Capacity, Make : Cromption Greaves, 207406, Location : 'A' Sub Stn
Ditto all as per item No. 19 above but 200 KVA Capacity, Make : Cromption Greaves, 318/6003-DG/08, Location : ATT
Ditto all as per item No. 19 above but 160 KVA capacity, Make : Kirloskar, 318/6008/DG/2011 , Location : MH Khadakwasla
Ditto all as per item No. 19 above but 125 KVA Capacity, Make : Kirlosakar,318/6076/DG/13, Location : NDA Area (Trolley Mounted)
Ditto all as per item No. 19 above but 82.5 KVA Capacity, Make : Kirloskar, 318/6006/DG/11, Location : VIP AREA
Ditto all as per item No. 19 above but 62.5 KVA Capacity, Make : Kirloskar, 318/6009/DG/13, Location : Power Houser (MIS Cell)
Ditto all as per item No. 19 above but 60 KVA Capacity, Make : Kirloskar, 318/6015/DG/2011, Location : New Pashan Gate / Trishakti gate
Ditto all as per item No. 19 above but 50 KVA Capacity, Make : Cromption Greaves , 207405, Location : GE office, AGE E/M office
Ditto all as per item No.19 above but 50 KVA Capacity, Make : Cummins, 318/6001-DG/04, Location : AFTT
Ditto all as per item No. 19 above but 50 KVA Capacity, Make : Kirloskar, 318/6054/ACT/15, Location : AFTT (Addl Hanger)
Ditto all as per item No. 19 above but 25 KVA Capacity, Make :Kirloskar, Location : AFTT (HRDF)
Ditto all as per item No. 19 above but 5 KVA Capacity, Make :Cromption Greavesr, Location :Tower 6
Ditto all as per item No. 19 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 10
Ditto all as per item No. 19 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 11
Ditto all as per item No. 19 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 16
Supply only B check kit for DG set of following capacities :- Note : It Includes to Oil filter (1.00 Ltr/0.5 ltr), Diesel filter , by pass element (a) 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 ,Location : Power House (Total 02 Nos)
Ditto all as per item No. 37 above but 320 KVA Capacity, Make :Cromption Greaves, 318/6002-DG/08, Location : Manoj Pandey Bldg
Ditto all as per item No. 37 above but 320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14, Location : Vyas Library
Ditto all as per item No.37 above but 200 KVA Capacity, Make : Cromption Greaves, 207406, Location : 'A' Sub Stn
Ditto all as per item No.37 above but 200 KVA Capacity, Make : Cromption Greaves, 318/6003-DG/08, Location : ATT
Ditto all as per item No. 37 above but 160 KVA capacity, Make : Kirloskar, 318/6008/DG/2011 , Location : MH Khadakwasla
Ditto all as per item No. 37 above but 125 KVA Capacity, Make : Kirlosakar,318/6076/DG/13, Location : NDA Area (Trolley Mounted)
Ditto all as per item No. 37 above but 82.5 KVA Capacity, Make : Kirloskar, 318/6006/DG/11, Location : VIP AREA
Ditto all as per item No. 37 above but 62.5 KVA Capacity, Make : Kirloskar, 318/6009/DG/13, Location : Power Houser (MIS Cell)
Ditto all as per item No.37 above but 60 KVA Capacity, Make : Kirloskar, 318/6015/DG/2011, Location : New Pashan Gate / Trishakti gate
Ditto all as per item No. 37 above but 50 KVA Capacity, Make : Cromption Greaves , 207405, Location : GE office, AGE E/M office
Ditto all as per item No. 37 above but 50 KVA Capacity, Make : Cummins, 318/6001-DG/04, Location : AFTT
Ditto all as per item No. 37 above but 50 KVA Capacity, Make : Kirloskar, 318/6054/ACT/15, Location : AFTT (Addl Hanger)
Ditto all as per item No. 37 above but 25 KVA Capacity, Make :Kirloskar, Location : AFTT (HRDF)
Ditto all as per item No.37 above but 5 KVA Capacity, Make :Cromption Greavesr, Location :Tower 6
Ditto all as per item No. 37 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 10
Ditto all as per item No.37 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 11
Ditto all as per item No. 37 above but 5 KVA Capacity, Make :Cromption Greaves, Location : Tower 16
Supply only coolent, K cool super plus 50-50 Premix
Supply only Battery water with electrolyte mix
Supply only Engine oil 15 W 40 turbo synthetic superior quality engine oil
Material and labour for replacement of unserviceable battery 12 V, 180 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Material and labour for replacement of unserviceable battery 12 V, 150 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Material and labour for replacement of unserviceable battery 12 V, 90 AH with maintenance free battery 12 Volt initially charged. Make - Exide / Amaron
Dismaintling, radiator assembly from the engine of following capacity of DG Set by disconnecting inlet and out let connections , overhauling/ servicing the radiator , clearing, removing blockages arresting leakages, assembling back incl necessary welding brazing as required , refixing , reconnecting and testing for proper functioning :- (a) 5 / 25 /50 KVA Capacity
(b)Ditto all as per item No. 61 above but 60/62.5/82.5 KVA Capacity
(c )Ditto all as per item No. 61 above but 160 /125 KVA Capacity
(d) Ditto all as per item No. 61 above but 200 KVA Capacity
(e)Ditto all as per item No. 61 above but 320 KVA Capacity
Dismaintling, removing the alternator /dynomo of from the engine of following capacity of DG Sets, opening up over hauling servicing, replcement of carbon brushes with holders, assembling back, refixing and testing for proper function. (a) 5 / 25 /50 KVA Capacity
(b) Ditto all as per item No. 66 above but 60/62.5/82.5 KVA Capacity
(c)Ditto all as per item No. 66 above but 160 /125 KVA Capacity
(d)Ditto all as per item No. 66 above but 200 KVA Capacity
(e)Ditto all as per item No. 66 above but 320 KVA Capacity
Dismantling , removing the self startor from the engine of following capacity DG Sets , opening up , over hauling/ servicing, replacement of carbon brushes with holders assembling back, refixing and testing for proper function : (a)5 / 25 /50 KVA Capacity
(b)Ditto all as per item No. 71 above but 60/62.5/82.5 KVA Capacity
(c)Ditto all as per item No. 71 above but 160 /125 KVA Capacity
(d)Ditto all as per item No. 71 above but 200 KVA Capacity
(e)Ditto all as per item No. 17 above but 320 KVA Capacity
Dismantling of fuel injector assembly complete from the engine of following capacity of DG Sets, reconditioning/ serving, replacement of pim spiral, washers, Cup injector,retainer, Cup screw etc assembling calibiration, setting for proper function refixing and testing for: (a) 5 / 25 /50 KVA Capacity
(b)Ditto all as per item No.76 above but 60/62.5/82.5 KVA Capacity
(c)Ditto all as per item No. 76 above but 160 /125 KVA Capacity
(d)Ditto all as per item No. 76 above but 200 KVA Capacity
(e)Ditto all as per item No. 76 above but 320 KVA Capacity
Disconnecting all the connections from alternator of DG Set of following Capacity removing the alternator from foundations , transporting to workshop, dismaintling completely including starter, roter, removing rotor and bearing clening all the parts with thinner and varnishing completely with F class varnishing, applaying expoxy coating, reassembling , dynamically balancing the alternator transporting and fixing on frame and reallignment within tolerance limit , connecting the alternator with all connections and testing on load completely all as directed. (a) 5 / 25 /50 KVA Capacity
(b)Ditto all as per item No. 81 above but 60/62.5/82.5 KVA Capacity
(c)Ditto all as per item No. 81 above but 160 /125 KVA Capacity
(d)Ditto all as per item No. 81 above but 200/250 KVA Capacity
(e)Ditto all as per item No. 81 above but 320 KVA Capacity
M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA Capacity, Make :Kirloskar, 318/6010/DG/14 including connecting and testing all as specified and directed. (a) Fuel Pipe
(b)Ditto all as per item No. 86 above but Air filter (inner & Outer)
(c)Ditto all as per item No. 86 above but V Belt
(d)Ditto all as per item No. 86 above but Water Pump Kit
(e)Ditto all as per item No. 86 above but Oil filter
(f) Ditto all as per item No. 86 above but Radiator hose pipe kit
M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 including connecting and testing all as specified and directed.(Manoj Pandey) (a) Air filter
(b) Ditto all as per item No.92 above but V belt
(c)Ditto all as per item No. 92 above but Fuel Pipe with washers
(d)Ditto all as per item No. 92 above but Battery terminals
(e)Ditto all as per item No. 92 above but Radiator Hose Pipe
M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 including connecting and testing all as specified and directed. (a) Air filter
(b) Ditto all as per item No. 97 above but V belt
(c)Ditto all as per item No. 97 above but Fuel Pipe with washers
M & L for replacement of defective spare parts of DG Sets of capacity 320 KVA Capacity, Make : Cromption Greaves, 318/6004/DG/09,318/6005/DG/09 including connecting and testing all as specified and directed.(Vyas librery) (a) Fuel Pipe
(b) Ditto all as per item No.100 above but Air filter (inner & Outer)
(c)Ditto all as per item No. 100 above but V Belt
(d)Ditto all as per item No. 100 above but Water Pump Kit
(e)Ditto all as per item No. 100 above but Oil filter
(f)Ditto all as per item No. 100 above but Radiator hose pipe kit
M & L for replacement of defective spare parts of DG Sets of capacity 200 KVA Capacity, Make : Cromption Greaves, 318/6003-DG/08 including connecting and testing all as specified and directed. (a) Oil filter
(b)Ditto all as per item No. 106 above but Turbo charger repair Kit
(c)Ditto all as per item No. 106 above but Water Pump Assembly
M & L for replacement of defective spare parts of DG Sets of capacity 200 KVA Capacity, Make : Cromption Greaves, 207406 including connecting and testing all as specified and directed. (a) Air filter
(b) Ditto all as per item No. 109 above but V belt
(c)Ditto all as per item No. 109 above but Fuel Pipe
(d)Ditto all as per item No.109 above but Battery terminals
M & L for replacement of defective spare parts of DG Sets of capacity 160/125 KVA, including connecting and testing all as specified and directed. (a)Air Filter
(b)Ditto all as per item No. 113 above but V Belt
(c)Ditto all as per item No. 113 above but Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 62.5 KVA Capacity, Make : Kirloskar, 318/6009/DG/13 including connecting and testing all as specified and directed. (a)Air filter
(b)Ditto all as per item No. 116 above but V Belt
(c)Ditto all as per item No. 116 above but Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 50 KVA, including connecting and testing all as specified and directed. (a) Air filter
(b) Ditto all as per item No. 119 above but V Belt
M & L for replacement of defective spare parts of DG Sets of capacity 25 KVA Capacity, Make :Kirloskar including connecting and testing all as specified and directed. (a) Air filter
(b)Ditto all as per item No. 121 above but V Belt
(c)Ditto all as per item No.121 above but Hose Pipe Set
M & L for replacement of defective spare parts of DG Sets of capacity 5 KVA Capacity, Make :Cromption Greaves including connecting and testing all as specified and directed. (a) Air filter
(b) Ditto all as per item No. 124 above but V Belt
(c)Ditto all as per item No. 124 above but Hose Pipe Set
M & L for replacement of Door Hinges of various capacity of DG Set all as specified and directed.
Supply and fixing battery lead with negative & Positive brass terminals of suitable size with 3 m length of each lead all as directed
M & L for complete checking of AMF panel,finding the fault,servicing complete including replacement of unserviceable spares and testing complete for manual & Auto operations allas directed. Note:- Supply only of new items required for replacement will be measured & paid seperately under respective item of schedule
Supply and fix in replacement AMF Relay all as specified and directed.
S&F repair AMF controller for DG set 320 KVA including taking down existing one all as specified and directed..
S&F in repair AMF controller for DG set 200 to 300 KVA all as specified and directed.
S&F in repair AMF controller for DG set 25 to 160 KVA including taking down existing one all as specified and directed..
S&F in repair AMF controller for Genset 1 to 5 KVA including taking down existing one all as specified and directed..
S & F control wiring of 2.5 Sqmm size two core stranded FRLS PVC insulated copper conductor cable of suitable length properly tagged and secured for indicators/ Meters including suitable size of copper lugs, with galvanised or cadmium plated high tensile nuts, bolts and washers etc all as specified and directed.
S&F in replacement of unserviceable contactor AC operated 4 pole, 415 volt suitable for the following capacity of DG set. (a) DG Set 320 KVA
(b)Ditto all as per item No.136 DG Set 200 KVA
(c)Ditto all as per item No.136 DG Set 160/125 KVA
(d)Ditto all as per item No.136 DG Set 60/82.5 KVA
(e)Ditto all as per item No.136 DG Set 50 KVA
(f) Ditto all as per item No.136 DG Set 25 KVA
S & F in repairs MCCB 3P 630 amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.
S & F in repairs MCCB 4P 500 amps, 36 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.
S & F in repairs MCCB 4P 250 amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.
S & F in repairs MCCB 4P 200 amps, 25 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.
S & F in repairs MCCB 4P 100 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.
S & F in repairs MCCB 4P 63-80 amps, 16 KA breaking capacity with adjustable thermal and adjustable magnetic overload protection with Ics=100% of Icu complete all as specified and directed.
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 320 KVA / 200 KVA complete all as specified and directed.
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 160 KVA /125 KVA complete all as specified and directed.
M&L for painting of DG set with synthetic enamel paint two coats of existing colour of capacity 25/50 KVA complete all as specified and directed.
S&F single phase preventor SPPR type SDz5, SPPR + Timer, 415 volts, 50 Hz, suitable for 3 phase DG Panel. Make : L&T Cat No XM81809OOOO or SEIMENS / BCH
S&F Electronic timers type ST100 , 415 volts, 50 Hz, suitable for 3 phase DG Panel. Make : L&T Cat No ST80328OOOO
S&F in replacement of window glass of canopy of capacity 320 KVA complete all as specified and directed.
S&F in replacement of window glass of canopy of capacity 200 KVA complete all as specified and directed.
S&F in replacemnt of heat proof asbestos rope 12 mm to 20 mm dia on engine exhaust pipe including dismataling of worn out asbestos rope and minor welding tightening in leakage of exhaust pipe complete all as directed confirming to IS specifications of fire proof/flame proof complete all as specified and directed.
Taking outold unserviceable battery charger from the following DG sets replacemnt with the following battery charger of suitable capacity and checking the terminals including petroleum jelly and spray cleaning and getting test certificate to produce Engr-in-charge for the following capacities of DG sets all as specified and directed. (a) Battery charger 24 volts 10 Amps capacity panel mounted suitable for 200/320 KVA DG set complete all as directed.
Ditto all as per item No.156 Battery charger 12 volts 20 Amps capacity panel mounted suitable for 160/125 KVA DG set complete all as directed.
Ditto all as per item No.156 Battery charger 12 volts 10 Amps capacity panel mounted suitable for 5/25/50/60/62.5/82.5 KVA DG set complete all as directed.
Dismentaling,opening,repairing, sevicing, cutting, welding, grinding, machening, refitting, commissioning and testing the silent type DG set 5KVA, 8.3 BHP, 3000 RPM make:- Greaves Model:- GP AII including replacement of the following spare parts : - (a) Engine Gasket - 1 set (b) Valve lock complete set -1 (c ) Valve guide Complete set-1 (d) Piston Assembly set - 1
S&F of Intelicompact NT(IC NT) Synchronizing unit and programming as per site requirement including taking down existing one from the circuit and connecting with necessary wiring complete all as specified and as directed and testing on completion.
M&L for earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm thick buried directly in ground vertically to a depth not less than 2.25mtr deep below ground level with top edge of the earth plate not less than 1.5mtr deep below normal ground level, connected with & including galvanised iron strip 32 x 6 mm connected to main test point as directed as earthing lead by means of nuts, bolts and washers of galvanised iron protected by 15 mm dia (medium grade) including concrete pit in PCC (1:3:6) type C-1, RCC cover slab 55 cm x 55 cm x 5 cm with reinforcement of 8 mm dia bar 100 mm c/c bothways including one handle made of 12 mm dia MS bar embedded in pre cast slab and 20 mm bore galvanised iron pipe"medium grade" for watering with GI funnel and wire mess including charcoal and salt in alternate layers of 15 cm including necessary excavation and earth work in any type of soil complete all as specified and as directed and testing on completion.
M&L 32x6mm galvanised iron strip Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required at site all as specified and sirected by Engr-in -charge.
Supply and fix in repairs HRC fuse Bolted/Din type of breaking capacity 80kA, 500 Volt, AC, 50 Hzs ISI marked suitable for fixing in the existing Din/Base of the following sizes ;- (a) HRC fuse 32 Amps to 100 Amps
(b) Ditto all as per item No.163 above but HRC fuse 125 Amps to 250 Amps
(c)Ditto all as per item No. 163 above but HRC fuse 315 Amps to 425 Amps
(d)Ditto all as per item No. 163 above but HRC fuse 500 Amps to 630 Amps
Supply & Laying, jointing & testing of UG LT cables XLPE insulated, PVC sheathed aluminium conductor multi stranded armoured heavy duty 1100 Volt grade cross sectional area 185 sqmm 3.5 core laid in trenches/ ducts/ along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed
Ditto all as per item No.167 above but size 50 sqmm 3.5 core
Ditto all as per item No.167 above but size 70 sqmm 3.5 core
Taking out existing defective worn out UG LT cable of any size 1100 volts grade from trenches of any size from different locations incl brick bats etc complete and depositing to store, all as specified and directed Note: Excavation & earth wk shall be measured and paid for separately
Excavation in trenches in hard/dense soil n.exc 1.5 M wide and not exceeding 1.5 mts in depth in wide for laying of cables and n exc 1.5 mtr in depth and getting out incl dressing/trimming sides and levelling/grading and ramming of bottom of excavation complete all as specified and directed.
Excavation in trenches in soft/dis integrated rock n exc 1.5m wide and n.exc 1.5m in depth and getting out complete all as specified and directed.
Returning, filiing in incl spreading, leveling watering and well ramming excavated soil in layers not exceeding 25 cm thick each, filling back in trenches after cables have been laid and tested as specified
Removing excavated surplus soil obtained from excavation to a distance not exceeding 1.5 m above the starting point, complete all as specified.
Supply and laying in 110 x 95 mm outer & inner dia, double walled corrugated (DWC) HDPE duct pipe confirming to IS-16205 Pt-24 with antirodent and non flame propogating properties of approval colour complete with fitting i.e.coupler,Tee,elbow clamp for cable protection. including taking down existing complete all as specified and directed
K K ENGINEERING SERVICES (BID ID -3136554)
Kedar Electricals (BID ID -3137346)
R. P. Suppliers and Construction Co. (BID ID -3135883)
SONU ENTERPRISES (BID ID -3135058)
KESARI AND SONS (BID ID -3135637)
Sneha Aircool (BID ID -3136095)
Sunhari Electricals (BID ID -3136875)
Star Electrical (BID ID -3134108)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .