Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC PLOT NO 28 SANTOSHIMA COLONY WEST MARREDPALLY SECUNDERABAD 500026 | HYDERABAD | TELANGANA | 500026 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.7 L+₹78,892 (3.17%)Rejected-AOC NO 133 RASHTRAPATHI ROAD SECUNDERABAD 500 003 | SECUNDERABAD | HYDERABAD | TELANGANA | 500003 | L2 | Rejected-AOC Being not L1 | |
| 3 | L3₹29.3 L+₹4.4 L (17.6%)Rejected-AOC | L3 | Rejected-AOC Being not L1 | |
| 4 | L4₹29.3 L+₹4.4 L (17.7%)Rejected-AOC | L4 | Rejected-AOC Being not L1 | |
| 5 | L5₹30.7 L+₹5.8 L (23.3%)Rejected-AOC | L5 | Rejected-AOC Being not L1 |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
3 Sept 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri M Saravanan, IDSE, GE
Garrison Engineer North 35 Allenby Lines Secunderabad 500087
REPAIRS REPLACEMENT OF INTERNAL ELECTRIC SUPPLY INCL ATTENDING DAY TO DAY COMPLAINTS WITH CONNECTED ITEMS AT CDM ADM AND OFFRS MD ACCN AREA UNDER E M N OF GE N SECUNDERABAD
2024_MES_664260_1
8816
Open Tender
Electrical and Maintenance Works
Item Rate
300 days
Garrison Engineer (North) Secunderabad
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GARRISON ENGINEER (NORTH)
₹90,000
Yes
26 Oct 2024
5 Jul 2024
10 Sept 2024
5 Jul 2024
3 Sept 2024
20 Jul 2024
Amount
Detailment of tradesman as per Job card for taking down existing unserviceable point wiring of any description/type/ size of light/fan/power/two way/bell etc on TW batten/conduit including removal of batten / conduit / gutties / wooden boards / switches / sockets / regulators/ light fittings etc and removal of unserviceable material out of site area and making good the disturbed surfaces of wall/ceiling all as specified & directed by Engg in Charge.
Disconnecting and removing the MCB DBs from any height ,stripping out the fitting for examine replacement of US spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning and testing complete all as specified & directed by Engg in Charge.
M & L for Point wiring with 1.5 Sq mm FRLS copper conductor single core PVC insulated sheathed 1100 V multistranded drawn through existing conduit and conduit accessories of suitable dia medium grade and modular accessories including fixing/grouting sunken/ surface along with existing flush box of suitable thickness covered with suitable modular cover plate including running up of 1.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for fixing the switches/ sockets/ regulators etc for one Light/Fan/Bell Point Controlled by One Switch complete all as specified and directed. NOTE: 1. Modular Cover Plate is inclusive of the rated quoted by the contractor 2. Cutting & Chases will be measured and paid separately
All as per Sl item No 3 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board
All as per Sl item No 3 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No. 3 here in before, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor complete all as specified and directed
All as per No.6 above but One 2/3 pin 15 Amps switch socket outlet point controlled by one switch on the same board
All as per Sl item No. 3 here in before, but for wiring drawn through PVC Casing and Capping, but for One light/fan/Bell point controlled by one, one way switch 5 amps, SP.
All as per Sl item No. 8 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No. 8 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No. 8 here in before, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
All as per SL No 11 above but One 2/3 pin 15 Amps switch socket outlet point controlled by one switch on the same board
S & F Modular switch 1 way 6/10 Amps, 1 Module complete all as specified and directed.
S & F Modular switch 1 way 16 Amps, 1 Module complete all as specified and directed.
S&F Modular Bell Push 10A, 1 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6 amps, 230 volts combined 2 Module complete all as specified and directed.
S&F Socket outlet modular type multipurpose 2/3 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed.
S & F Modular ceiling fan regulator stepped type heavy duty suitable to work on 230 volts, 2 Module complete all as specified and directed.
M & L for Point wiring with 1.5 Sq mm copper conductor single core PVC insulated FRLS 1100 Volts multistranded drawn through and including 20 mm rigid PVC conduit surface and conduit accessories of suitable dia medium grade and existing pressed steel terminal boxes including fixing/grouting sunken/ surface as per site requirement covered with suitable laminated sheet for fixing switches / sockets/ regulators etc including running up of 1.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor along with wiring and connecting to the common earth dolly for One light/fan/bell point controlled by one, one way switch 5 amps, SP complete all as specified and directed. NOTE: 1. Modular Cover Plate is inclusive of the rated quoted by the contractor. 2. Cutting & Chases will be measured and paid separately.
All as per Sl item No 19 here in before, but for One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board .
All as per Sl item No 19 here in before, but for One 3 pin, 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per Sl item No. 19 here in before, but for using 2.5 Sqmm single core copper conductor cable of multistranded PVC insulated sheathed FRLS 1100 Volts grade for 3 Pin 15 Amps switch socket combination point on independent board including running of 2.5 Sq mm FRLS copper conductor PVC insulated cable as earth continuity conductor
S & F switch piano single pole flush type 5 amps, 230 volts complete all as specified and directed.
S&F Bell push 5 A flush type complete all as specified and directed.
S&F Socket outlet flush type multipurpose 2 in 1, 3 Pin, 5 amps, 230 volts complete all as specified and directed.
S & F Switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1 230 Volts complete all as specified and directed.
S & F Switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 amps flush type with complete all as specified and directed.
S & F Ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and directed.
S & F Electronic type regulator stepped heavy duty for ceiling fan suitable to work on 230 volts complete all as specified and directed.
S&F Bell ding dong working on 230 volts AC Supply complete all as specified and directed.
S & F Lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings complete all as specified and directed.
S&F Round shape 12 watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete with all accessories all as specified and directed by Engg-in-Charge.
S&F Round shape 15 watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete with all accessories all as specified and directed by Engg-in-Charge.
S & F in repairs LED spot light 06 watts including LED 06 watts lamp COB complete with all accessories all as specified and directed by Engg-in-Charge
S & F 4 module LED Foot Lights of 3 watts including Mounting to Chair/wall in complete all as specified and directed by Engg in charge.
S & F in repairs Fancy type lights (Round Type) of 20 watts including LED lamp complete with all accessories all as specified and directed by Engg-in-Charge.
S & F in repairs 4x1 Recess/Surface mounted LED luminarie of 36 watts with soft light along with driver and glare free symmetrical illumination suitable for armstrong and Grid ceiling complete with all accessories all as specified and directed by Engg-in-Charge.
S & F in repairs 2x1 recess/surface mounted LED 28 Watts flat panel along with driver and with high brightness LED for glare free homogeneous illumination suitable for POP false ceiling/GRID Ceiling with all accessories all as specified and directed by Engg-in-Charge.
S&F LED luminaire 600 mm x 600 mm,35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engg-in-Charge. Note: Cutting of False ceiling and removal of old fitting and re-arranging the False ceiling with existing size, Gypsum board/POP false ceiling is to be done if required. Cost of False ceiling work is inclusive of rate quoted.
S & F of False ceiling fitting Iron Ring suitable for POP/GYPSUM False ceiling and suitable for above mentioned recess mounting light
S & F in repairs wall mounted LED batten of 10 watt with LED Lamp, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver and connecting to all accessories from ceiling rose to fitting complete all as specified and directed by Engg-in-Charge.
S & F in repairs wall mounted box type LED batten suitable for 20 watts with LED tube 20 watts lamp along with integrated driver and connecting to all accessories from ceiling rose to fitting complete all as specified and directed by Engg-in-Charge.
S & F in repairs wall mounted batten type LED light with co extruded polycarbonate body suitable for 20w LED lamp along with integrated driver complete and connecting to the point wiring with necessary flexible copper conductor of multistrand three core of suitable length from fitting to the ceiling rose all as directed by Engineer-in-charge.
S & F in repairs wall mounted batten type LED light with co extruded polycarbonate body suitable for 36/40w LED lamp along with integrated driver complete and connecting to the point wiring with necessary flexible copper conductor of multistrand three core of suitable length from fitting to the ceiling rose all as directed by Engineer-in-charge.
S & F in repairs LED security Light luminaire 25 watts with deep drawn housing including all accessories and Lamp, with suitable pipe bracket 25 mm dia 0.60 Mtr length fixed on wall with suitable flat iron clamps and nut bolts all as specified and as directed.
S & F in repairs MCB SP 6 to 32 Amps 240 volts, 'C' curve for fixing on MCB DB's all as specified and as directed.
S & F in repairs MCB SPN 40 to 63 Amps 240 volts for fixing on MCB DB's all as specified and as directed.
S & F in repairs MCB Four pole, 415 volts, 'C' curve suitable for fixing on MCB DB of capacity 40 to 100 Amps all as specified and as directed.
S & F Sheet metal enclosure MCB DB SPN 8 way with 200 amps rated bus bar 240 volts double door with locking system complete all as specified and directed.
All as per Sl item No 49 here in before, but SPN 12 way DB complete all as specified and directed.
S & F in repairs Horizontal type TPN DB 4 way double door made out of CRCA sheet housing with powder coating & confirming to IS 13032, IS 8623, BS 5486 accommodated suitably in a MS enclosure weather proof made out of 3 mm thick MS sheet having hinged and robust locking arrangement including painting by red-oxide one coat and powder coated all as specified and directed.
All as per Sl item No 50 here in before, but VTPN 4 way DB Suitable for MCCB 160Amps complete all as specified and directed.
S & F in repairs Modular Single pole and Neutral enclosure (Modular AC Box) with a two pin and earth plug and socket complete with one single pole MCB 25 Amps (AC Box) complete all as specified and directed.
M & L Submain wiring with 2 runs of single core 4 sqmm PVC insulated sheated multistranded FR 1100 volts grade with copper conductor drawn through existing non-metallic rigid PVC conduit and conduit accessories of medium grade not less than 25mm dia including one run of single core 4 sqmm PVC insulated sheated multistranded 1100 volts grade with copper conductor cable as earth continuity conductor along with the wiring and connected from DB to DB/main board including removing the existing unserviceable submain wiring complete all as specified and as directed. Note: 3 runs of 4 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
All as per Sl item No 54, but 2runs of single core 6 sqmm and one run of single core 6 sqmm as earth continuity conductor complete all as specified and directed. Note: 3 runs of 6 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
All as per Sl item No 54, but 2runs of single core 10 sqmm and one run of single core 10 sqmm as earth continuity conductor. Note: 3 runs of 10 Square mm cable and 1 run of PVC conduit with accessories shall be measured as 1 unit of running metre.
M&L Earthing with galvanized mild steel earth plate electrode 60 centimetre x 60 centimetre x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metres below ground level, the top edge of the earth plate at a depth of not less than 1.5 metres below ground level connected to galvanized iron earth wire of 4 mm dia by means of bolts, nuts and washers made out of GI / steel earth wire protected by GI light grade pipe 15 mm bore, 20mm dia light grade galvanised iron pipe with funnel wire mesh for watering and connecting to main switch board / control board all s shown in electrical plate of SSR Pt - I connected to earthing test point and including testing on completion complete all as specified and as directed. NOTE: The unit rate shall also include for excavation, earth work in hard/dense soil, plain cement concrete 1:3:6 type C1 by using 20 mm graded aggregate in pit, 50 mm thick reinforced cement concrete 1:2:4 type B1 using 20 mm graded aggregate cover duly reinforced with 8 mm dia TMT bars @ 100mm centre to centre both ways, CI cover with CI frame hinges, galvanised iron funnel with watering pipe, wire mesh, complete.
M&L Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and directed.
M&L for Cutting chases, pinning in. making good to facings where required and pointing in cement mortar 1:3 to ends or edges of andings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Taking down ceiling fans 48”/56” sweep or Exhaust fans upto 300mm, removing/cleaning of dust properly cleaning, greasing & overhauling of bearings including refixing in same location and connecting up all as directed by Engr-in-Charge. Note : Replacement of defective/worn out parts will be measured & paid for separately
S&F in repairs 2.00/2.50 Mfd capacitor complete all as specified and directed.
S&F in repairs 3.15/4.00 Mfd capacitor complete all as specified and directed.
S&F in repairs Ball bearing/Gun Metal Bush of existing ceiling fans on site complete all as specified and directed.
S&F in repairs ‘U’ clamps complete with nut, bolts & split pins Heavy duty, suitable for existing ceiling fan on site complete all as specified and directed.
S&F in repairs M.S. rod for ceiling fans 3 ft long with both end suitable size holes and cut mark all as specified and directed by Engg in Charge.
S&F in repairs Nut of bolts washers for fan blades fixing of ceiling fan of any make/size/type as per site requirement (6 Nos for each set) suitable for existing ceiling fan on site complete all as specified and directed.
M&L Rewinding of burnt Ceiling fan motor of size 48"/56" sweep with super enameled copper wire of suitable size as per details given below of any make, type, model incl transportation complete, all as specified and as directed by Engr-in-Charge.
All as per Item No 67 above but for exhaust fan motor of sweep upto 450mm complete all as specified and directed.
M&L Painting of ceiling fans 48”/56” size complete at site, with super synthetic enamel paint by spraying incl filling cavities with filler, one coat after cleaning all dust etc complete, all as specified and as directed by Engr-in-Charge.
S&F in repairs Metallic louvers mounted suitable for exhaust fan of 300 to 450 mm on wall all as specified and as directed by Engr-in-charge.
S&F in repairs Plastic body including louvers 200 to 300 mm size fan all as specified and as directed by Engr-in-charge.
S&F in repairs Motor of plastic body exhaust fan 300mm size all as specified and as directed by Engr-in-charge.
S&F in repairs 1100 Volt grade cable flexible 3 core PVC insulated PVC sheathed with stranded copper conductor of size 2.5 sqmm all as specified and as directed by Engr-in-charge
S&F in repairs Modular switch 1 way 6/10 Amps, 1 Module complete all as specified and directed.
S&F in repairs Modular switch 1 way 16 Amps, 1 Module complete all as specified and directed.
S&F in repairs Modular Bell Push 6A, 1 Module complete all as specified and directed.
S&F in repairs Socket outlet modular type multipurpose 2/3 Pin, 10 amps, 230 volts combined 2 Module complete all as specified and directed.
S&F in repairs Socket outlet modular type multipurpose 2/3 Pin, 6/16 amps, 230 volts combined 2 Module complete all as specified and directed.
S&F in repairs Modular ceiling fan regulator stepped type heavy duty suitable to work on 230 volts complete all as specified, 2 Module complete all as specified and directed.
S&F in repairs Bell ding dong working on 230 volts AC Supply complete all as specified and directed.
M & L Bracket made out of GI pipe 25 mm dia bore not less than 0.6 mtr long and fixed on walls bent to required shape complete all as specified and directed by Engg-in-Charge.
S&F in repairs Ultra bright LED polycarbonate tube light 20 watt with very high efficiency suited for installation in existing T8 fitting with G13 lamp holders (single side connection) complete all as specified and directed.
S&F in repairs LED 18 watts retrofit bulb suitable for 2x36 watt CFL fitting all as specified and directed by Engg in Charge.
S&F in repairs LED drivers of 18 Watts fitting complete all as specified and directed.
S&F in repairs LED DRIVERS FOR 2X2 FITTING of 36 to 42 watts complete all as specified and directed.
S&F in repairs LED lamp 9/10 Watts complete all as specified and directed.
S&F in repairs PVC Round blocks of 4" complete all as specified and directed.
S&F in repairs PVC Dummy sheets circular type of 4" complete all as specified and directed.
S&F in repairs PVC Dummy sheets circular type of 6" complete all as specified and directed complete all as specified and directed.
S&F in repairs Rigid PVC casing & capping 20/25 mm wide complete all as specified and directed.
S&F in repairs PVC rectangular box (Gang box) with 5 Amps switch socket complete all as specified and directed.
S&F in repairs PVC rectangular box (Gang box) with 5/15 Amps switch socket complete all as specified and directed.
S & F Surface Modular Box of 6 way along with 6 way Modular plate and 2 Nos of 16 Amps Switches and 6/16Amps multipurpose Sockets with connected internal wiring complete all as specified and directed by Engg in Charge. Note: Modular Plate, Switches & Sockets are inclusive of the rate quoted.
S&F in repairs PVC wire of Flexible cord with copper conductor multistanded of twin core 23/0.198 complete all as specified and directed.
S&F in repairs PVC copper wire of 1.5 sq mm single core multistranded complete all as specified and directed.
S&F in repairs PVC copper wire of 2.5 sq mm single core multistranded complete all as specified and directed.
S&F in repairs PVC copper wire of 4 sq mm single core multistranded complete all as specified and directed.
S&F in repairs PVC copper wire of 6 sq mm single core multistranded complete all as specified and directed.
S&F in repairs Service wire twin core of 10.0 sq mm aluminium type flat unarmored complete all as specified and directed.
S&F in repairs MCB SP 6 to 32 Amps 240 volts,10 KA 'C' curve for fixing on MCB DB's complete all as specified and directed.
S&F in repairs MCB SPN 40 to 63 Amps 240 volts, 10 KA 'C' curve for fixing on MCB DB's complete all as specified and directed.
S&F in repairs MCB Four pole, 415 volts, 'C' Curve suitable for fixing on MCB DB of capacity 40 to 100 Amps complete all as specified and directed.
S&F in repairs MCB Three pole, 415 volts, 'C' curve suitable for fixing on MCB DB of capacity 25 to 63 Amps complete all as specified and directed.
S&F in repairs MCCB Four pole, 415 volts suitable for fixing on MCCB DB of capacity 100 Amps complete all as specified and directed.
S&F in repairs MCCB Four pole, 415 volts suitable for fixing on MCCB DB of capacity 160 Amps complete all as specified and directed.
S&F in repairs Rigid non-metallic PVC conduit 25mmexclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and directed.
S&F in repairs Rigid non-metallic PVC conduit 20 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed.
Detailment of tradesman as per Job card for disconnecting and removing any fitting of any size from any height , stripping out the fitting for examine replacement of un serviceable spare parts, reassembling, refixing in original position including minor repairs for the smooth functioning testing complete all as specified and directed.
All as per item No 108 but for MCB DBs.
All as per item No 108 but for Switch boards.
THE DECAN ENGINEERING AND REFRIGERATION COMPANY (BID ID -3075861)
Sri venkateswara Electricals (BID ID -3079009)
SUN LIGHT HOUSE (BID ID -3073819)
Sri Balaji Enterprises (BID ID -3076388)
Charan sales and Service (BID ID -3077126)
M/s. A&T Enterprises (BID ID -3074904)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .