Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹64.6 LAccepted-AOC NO 403 BENGALI COLONY RANJHI JABALPUR MP 482001 | JABALPUR | JABALPUR | MADHYA PRADESH | 482001 | L1 | Accepted-AOC BEING LOWEST BIDDER | |
| 2 | L2₹69.1 L+₹4.2 L (6.40%)Rejected-Finance 116 JAI BHEEM NAGAR POLIPATHAR GWARIGHAT ROAD JABALPUR MP 482008 | JABALPUR | MADHYA PRADESH | 482008 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹73 L
EMD Value
₹1.3 L
Closing Date
16 Mar 2024, 6:00 pmClosed
CWE JABALPUR
HQ CWE JABALPUR OPPOSITE SUPPLY DEPOT SADAR 482001
SPECIAL REPAIR TO BASKET BALL, SQUASH COURT AND TENNIS COURT (02 NOS) AT DSOI UNDER GE(W) JABALPUR
2024_MES_641202_1
81029/E8
Open Tender
Civil Works
Item Rate
270 days
JABALPUR
AS PER NIT
7 documents required · 7 mandatory
₹1,000
Yes
GE WEST JABALPUR
₹1.3 L
Yes
15 Apr 2024
7 Feb 2024
18 Mar 2024
7 Feb 2024
16 Mar 2024
28 Feb 2024
7 Feb 2024 - 27 Feb 2024
Amount
M & L Asphalt base for outdoor recreational surface complete all as specified as under and as directed : A. Surface Dressing of soil/hard surface after removing existing grass and weeds B. Compaction of the sub base using 8-10 Ton Tandem Vibratory Roller C. Pre-construction anti-termite treatment and weedicide on the total area by spraying . D. Laying of 75mm thick water bound macadam (compacted thickness) in one layer. WBM to be densely compacted by keying and inter locking the stones to ensure that no settlement takes place. E. Laying of 30 mm thick Asphalt BM course (compacted thickness) in Hot Mix Plant using VG-30 grade of paving butimen @4% by weight of total Mix. F. Laying of 20 mm thick dense Asphaltic Concrete course (compacted thickness) in Hot Mix Plant using VG-30 grade of paving butimen @6% by weight of total Mix. G. An open saucer drain at a lower end. H. 150mm high dwarf wall for support along the edges.
M & L for Synthetic Basketball Court complete all as specified as under and as directed : (a) PRIMER: 100% synthetic court of Acrylic (KDF) based emulsion to improve bond of acrylic court system to the concrete or asphalt surfaces (b) RESURFACER: One coat of Acrylic (KDF) Resurfacer 367-30 for filling and smoothing asphalt or concrete surfaces in preparation for synthetic court of Acrylic (KDF) ITF Approved court system, and also fills the surface chips, voids and conceals repairs while providing a smooth surface for color coating (c) CUSHION COAT: 4 Layers of synthetic court of Acrylic (KDF) cushion for asphalt or concrete surfaces in preparation for synthetic court of Acrylic (KDF) ITF approved system (d) PRECOAT: 2 layers of synthetic court of Acrylic (KDF) based textured topcoat ideal for color coating courts and other sport pavement surfaces. (e) OVERLINE : 100% synthetic court of Acrylic (KDF) based high hiding line paints.
SQUASH COURT
Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
Dismantling framed timber scantling 40 Sqcm and over in section fixed on PCC floor / concrete blocks with or without nails, spikes, etc., and removing from site complete all as specified and as directed.
M & L for Squash Court Maple Wooden flooring complete all as specified as under and as directed : (a) Flooring Surface Board:- Made of Kiln Seasoned (moisture content of approximately 14% at the time of dispatch), treated Maple Wood finished with 24mm thick, 57 to 83 mm wide and in random length in tongue and groove shape. The edges of the boards will have a finger lock groove and the bottom side with air pass groove and treated with special anti termite and water resistant lacquer. (b) The Under Frame:- Made of commercial quality pine wood runners of 70 mm x 45 mm, treated with anti-termite solution and fixed on the bottom side with 10 mm thick air cushioned pads, stappled through the two wings at 300 mm x 300 mm Installation:- IPS subfloor treated with a vapour barrier to be placed on the leveled IPS sub-floor before laying the under frame. The runners having air cushion pads to be placed on the vapour barrier in perfect level at 350 mm in 1 direction. The surface board to be screwed to the runner through the tongue only and will lock the screwed tongue by the groove of adjoining board. Ends of the boards will be locked by inserting the wooden fingers through the edge grooves and fixed with suitable adhesive. An expansion of 8 to 10 mm to be left open between the wooden flooring and the surrounding tiled area / walls (c) Finishing:- After laying the flooring, the floor boards will be levelled to a uniform surface and applied a thin coat of water based polish on the the face, complete all as directed.
M & L for Hard Plaster complete all as specified as under and as directed : (a) Application of Hard Plaster System meeting specifications for Squash Court laid down by "World Squash Federation" (WSF). The system consists of a 10 mm base coat with silica sand and top coat (WSF approved hard plaster) of 2-3 mm, which makes it a total thickness of 12 - 13 mm. Due to extremely hard nature of plaster, a slight uneven color distribution may be seen once the plaster has dried, this doesn't affect the strength or integrity of the plaster and must not be considered as a defect. (Note : Wall plaster playing area, only below red lines, is to be considered for payment purpose)
S & F, in repair, 12 mm thick 2 layered fibre reinforced , cement base and resin modified Squash Court Wall Painting complete all as specified and as directed.
M & L for 2130mm high (over the finished floor) and 12 mm thick toughened Glass Back Wall, free standing, with four panels, 1 door, 4 fines, fixtures and fittings and all the materials required for eracting the glass walls. The height of the glass wall will be 2130 mm above the finished floor, complete all as directed.
M & L for Sound Board ( 7 feet x 17 inch x 22 gauge) made of tin sheet including all necessory fittings complete all as specified and as directed.
M & L WSF approved standard game line marking paint complete all as specified and as directed.
TENNIS COURT
M & L Asphalt base for outdoor recreational surface complete all as specified as under and as directed : A. Surface Dressing of soil/hard surface after removing existing grass and weeds B. Compaction of the sub base using 8-10 Ton Tandem Vibratory Roller C. Pre-construction anti-termite treatment and weedicide on the total area by spraying . D. Laying of 75mm thick water bound macadam (compacted thickness) in one layer. WBM to be densely compacted by keying and inter locking the stones to ensure that no settlement takes place. E. Laying of 30 mm thick Asphalt BM course (compacted thickness) in Hot Mix Plant using VG-30 grade of paving butimen @4% by weight of total Mix. F. Laying of 20 mm thick dense Asphaltic Concrete course (compacted thickness) in Hot Mix Plant using VG-30 grade of paving butimen @6% by weight of total Mix. G. An open saucer drain at a lower end. H. 150mm high dwarf wall for support along the edges.
SYNTHETIC TENNIS COURT M & L for Synthetic Tennis Court complete all as specified as under and as directed : (a) PRIMER: 100% synthetic court of Acrylic (KDF) based emulsion to improve bond of acrylic court system to the concrete or asphalt surfaces (b) RESURFACER: One coat of Acrylic (KDF) Resurfacer 367-30 for filling and smoothing asphalt or concrete surfaces in preparation for synthetic court of Acrylic (KDF) ITF Approved court system, and also fills the surface chips, voids and conceals repairs while providing a smooth surface for color coating (c) CUSHION COAT: 4 Layers of synthetic court of Acrylic (KDF) cushion for asphalt or concrete surfaces in preparation for synthetic court of Acrylic (KDF) ITF approved system (d) PRECOAT: 2 layers of synthetic court of Acrylic (KDF) based textured topcoat ideal for color coating courts and other sport pavement surfaces. (e) OVERLINE : 100% synthetic court of Acrylic (KDF) based high hiding line paints.
Scarifying or picking gravelled, macadam or bituminous macadam surfaces in area exc 400Sqm and depth exc 50mm but n exc 100mm deep by using mechanical scarifier including racking over and grading the broken-up surfaces to the proper camber or removing to a distance not exc 50M from the starting point and stacking complete all as directed
S & F, in repair, ready made Basket ball poles of 200 mm dia medium grade MS pipe with 8 mm thick base plate and 6 mm thick connecting plates at the top to fix 20 mm thick acrylic board, including ring and net of standard size ,necessary cutting, drilling hole, welding etc complete including two coats of synthetic enamel paint over a coat of red oxide primer and including excavation and earthwork and fixing the post in PCC (1:3:6), post hole size 60x60x100 CM complete all as specified and directed .
S & F 80mm dia Medium grade Mild Steel Works as in goal posts including cutting drilling bolting, welding etc and two coats of synthetic enamel paint over a coat of red oxide primer and including excavation and earthwork and fixing the post in PCC (1:3:6), post hole size 60x60x100 cm complete all as specified and directed .
S & F 8mm thick Rolled Mild Steel Plates (plain or Chequered) channels, square cut or notched (ordinary and counter sunk), forming holes, with riveted, bolted or welded attachment conforming to Fe -290 (Gde E-165) complete all as specified and directed .
M&L for prepairing new or previously untreated surfaces of pipes of any description , over 10 cm in width or girth, and applying two coats of Synthetic enamel paint ( ordinary tint), over one coat of red oxide primer complete all as specified and directed .
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) including removal of debris to out side MD land complete all as specified & directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete including removal of debris to out side MD land complete all as specified & directed.
M&L 25 mm thick cement concrete (1:2:4), type B-0, using 12.50 mm graded crushed stone aggregate as in floors including finishing the surface rough & even for receiving kota/tiles complete all as specified and directed.
Material and labour for Glazed ceramic tiles of size 350x 250x 7mm/ 450X 350X 7mm thick in vertical surfaces such as dado/ skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles, over and including 10mm thick rendering in CM 1:4 complete all as specified and directed.
M&L for scratch free dark shade vitrified floor tiles, minimum 10mm thick (square/ rectangular) area of each tile not exc 0.36 Sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles over and including 15 mm thick screed bed in CM (1:6) complete all as specified & directed.
Dismantling of brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars etc but excluding ashlar ficings, dressed stone work and pre-cast concrete articles complete all as specified and directed.
M&L Brick work with sub class 'B' fly ash bricks, straight or curved on plan, exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L Brick work with sub class 'B' fly ash bricks, straight or curved on plan, exc 6m mean radius built in cement mortar (1:4) in half brick thick wall complete all as specified and directed.
M&L PCC (1:4:8) type D-2 (40mm graded crushed stone aggregate) as in foundation, sub base, mass concrete & cinder concrete etc. complete all as specified and directed.
Taking down cement plaster and grit plaster any description on brick or stone walls,ceiling etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed.
M&L for rendering on fair faces of brick work or concrete surface of wall 10mm thick in CM (1:6), finished even and smooth without using extra cement etc complete all as specified and directed
M&L 15 mm thick rendering in CM 1:4 on external surfaces of walls & top surfaces of chajja/roof, mixed with liquid water proofing compound as per Manufacturer's' instructions, surface finished even and smooth without using extra cement complete all as specified & directed. ( Note : Liquid water proofing compound will be measured and paid for separately against relevant item of BoQ as "Supply only")
Supply only liquid water proofing compound ISI Marked, of make as approved by GE complete all as specified & directed.
M&L for 5mm thick rendering in CM( 1:3) as on ceiling, soffit of RCC shelves, surfaces finished even and smooth without using extra cement complete all as specified & directed.
M&L for preparing new plastered or un-plastered ceiling surfaces and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint complete all as specified and directed.
M&L for preparing new plastered or un-plastered surfaces of walls and applying two coats of oil bound distemper with and including 2mm thick wall care putty over a coat of chalk whitining on walls complete all as specified and directed.
S&F in repairs floor door spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed to aluminium door etc. complete all as specified and directed.
S&F in repair door closer hydraulically regulated designation No-2 universal type of aluminium extruded section body fixed to door frames with screws or by welding suitable for door shutters of 701-805 mm in width & wt between 36-60 kgcomplete all as specified and directed by Engr-in-charge.
S&F anodised aluminum door, window and ventilator shutters, Powder Coated (minimum thickness of powder coating 50 micron) , sliding type without sash bars, aluminium section weighing 0.55 Kg/ RM including necessary jointing cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (01 No), hinges type B-21 100mm long (02 Nos) suitable handle (01 No) including making good the disturbed surfaces complete all as specified and directed
S&F in repair mild steel Mortice lock,vertical type size 100 mm 4 lever suitable for aluminium door including fixing with stainless steel screw complete all as specified and as directed
S & F in repair 6 mm thick Figured glass, pin head type and glazing with oil putty in squares exc 0.5 sq. m in each pane complete all as specified and as directed
S & F in repairs Vitreous china urinal half stall type ,white, including connection to flushing pipe and outgoing pipe complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 15mm bore of pipe complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 20mm bore of pipe complete all as specified and as directed.
Taking up or down steel tubing and connections, including cleaning for refixing or removing to store of size 25mm bore of pipe complete all as specified and as directed.
S&F 25mm bore tubes medium grade galvanized with all fitting such as socket, elbow, Tee tee, union and short length etc. and fixed complete to walls and ceilings or laid in floors of any length all as specified and directed by Engr-in-charge.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors for 16mm bore of pipe including Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor and all necessary fittings etc complete all as specified and directed.
Supplying and laying of CPVC pipes SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors for 20mm bore of pipe including Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor and all necessary fittings etc complete all as specified and directed.
M&l for Cutting chases, pinning in. through brick walls and making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cutting not exc 10 cm girth complete all as specified and directed.
Internal Electrification
Taking down carefully any type of old unserviceable point wiring copper or aluminium conductor (light, fan, socket, bell or power) point complete with fittings such as switches ceiling roses, lamp holders, sockets, fan regulators, call bell, light fittings with PVC conduit surface / concealed or wooden battens including sunken cast iron / pressed steel terminal boxes etc and making good the disturbed surfaces of walls, roof, floors etc to match with the existing surfaces complete all as specified & directed by Engineer-in-Charge. Note: Painting work measured and paid seperately under respective items.
Taking down carefully any type of old DBs / AC box complete all as specified and directed.
Material & Labour for point wiring for One light Point controlled by one switch., with three layer PVC Insulated 1.5 Sqmm multi-stranded copper conductor FRLSH cable 1100 Volts grade drawn into and incuding concealed PVC conduits medium grade not less than 20mm( ISI marked) including all fitting and fixing accessories including 1.25 mm thick sunken pressed steel terminal boxes/Modular metal flush box duly painted with two coats of anti-corrosive paint outside and two coats of aluminium paint inside with and including 3mm thick hylam brand laminated white bakelite sheet cover for mounting switches, sockets, fan regulators fixed with CP screws with cup wahsers and PVC insulated 1.5 Sqmm multi-stranded copper conductor cable as earth wire and making good the disturbed surfaces with cement sand mortar (1:3) to match with the existing specification complete all as specified & directed by Engineer-in-charge
Ditto as per above item but one fan point controlled by one way switch 5 amps
Ditto as per one 3 pin 5 Amps switch socket outlet controlled by one switch on same board
Ditto as per above item but one 3 pin 5 Amps switch socket outlet controlled by one switch on independent board.
Description same all as per item No. 53 here in above but with 1100 Volts grade copper stranded conductor FRLSH cable of size 2.5 Sqmm main & with 2.5 Sqmm earth multi-stranded copper conductor cable as earth wire for 3 pin switch socket outlet 15 Amp on Independent board complete all as specified & directed by Engineer-in-Charge.
Supply & fix switch piano, flush type single pole, one way 5/6 Amps, 240 volts complete all as specified & directed.
S&F Switch socket combination 5 in 1, 5 pin 5/6 amps flush type univarsal of polycarbonate body, complete all as specified & directed.
S&F Switch socket combination 5 in 1, 5 pin 6/16 amps flush type univarsal of polycarbonate body, complete all as specified & directed.
S&F Switch socket outlet 2 in 1, 5 pin 5 amps flush type univarsal of polycarbonate body, complete all as specified & directed.
Supply & Fixing in repair sheet metal enclosure MCB DB double door [Acrylic], single pole and neutral, 240 volts, 8 way with 200 Amp, 10 KA breaking capacity rated bus bar with blanking plate wherever required and IP-43 degree protection complete all as specified & directed.
S&F in replacement MCB Single Pole and Neutral 240Volt, 40 Amps,10KA breaking capacity complete all as specified & directed.
S & F in repair Smart bright Batten Series, LED luminaire using LEDs 22 watt 110 LM/watt with diffuser which ensures uniform distribution and comfort batten series features latest LEDs and delivers consistent light output, stable color start Extruded Aluminum housing, Energy efficient, Flicker free start Inbuilt driver unit Suitable for wall and ceiling mounting using brackets complete all as specified and as directed.
S&F in replacement MCB Single Pole 240Volt, upto 40Amps,10KA breaking capacity complete all as specified & directed.
S & F LED Mirror light fitting 2 ft tubelight 12 watt aluminum housing and integrated electronic driver THD max 10 % ,CRI min 80 % complete with fixing arrangements on wall complete all as specified and directed.
S&F LED light fitting square 59.5x59.5 CM Not less than 36 watt along with fixture Surface / Recessed /Pendent mounting LED luminaries with diffuser channel Luminaires ers, connector block, etc . Complete with all accessories internally pre-wired and including round wood block, connecting up with three core flexible flexible copper conductor cable suitable size complete all as specified and directed by Engineer in charge.
Material & Labour for earthing complete with galvanised steel earth plate electrode of size 600mm x 600mm x 6mm thick burried directly in ground (Earth pit not less than 2.25 m deep below the normal ground level with top edge of earth plate not less than 1.5 m below normal ground level) connected to galvanised earth wire 4 mm dia as earth wire or earthing lead by means of bolts, nuts, check nuts and washers of GI or steel complete as shown in Electrical Plate No. 3 of SSR-2009 (Part-I) including charcoal dust, common salt, 20mm bore GI medium grade watering pipe, MS Sheet funnel with wire mesh, including 15mm dia GI pipe light grade for protection of GI earth wire including PCC pit 1:2:4 type B-1 using 20mm graded crushed stone aggregate with angle iron 40X40X5mm frame 60mm thick RCC cover with 8mm # TMT bars @ 100 mm centre to centre both ways i.e. horizontal and vertical complete all as directed by Engineer-in-charge and testing for required value complete. Note:-(i) If earth resistance of earthing is not found satisfactory it will be redone by the contractor without any extra cost to Govt. (ii) GI wire and protection pipe from earth electrode to test point max upto 7.50M shall be deemed to be included in the unit rates as quoted by the contractor.
S & F in repair for Ceiling rose surface bakelite 65 mm x50 mm three terminal AC 230 volts flush type complete all as specified and directed by Engineer in charge
S & F in repair fan regulator Step type of polycarbonate complete all as specified and directed by Engineer in charge.
EXTERNAL Electrification
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 16sqmm, 4core including jointing materials such as cable glands & lugs etc complete all as specified and directed.
Supply and fixing LED flood light fitting (warm white 4000K ) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics with IP 65/66 protection 400 watt IK-07,length 514 mm, W-374mm h-233 mm lumen efficacy>145 Lm/W THD<10 complete all as required and directed.
Supply , laying and testing PVC insulated ,PC sheathed cable galvanised steel strip or wire armoured electric control cables with stranded copper conductor of size 3 core 1.5 sqmm complete all as required and directed.
Supply and erecting steel tubular poles complete with cast iron base plate, finial taper plug , bolts Nuts & screws complete all as specified type 410SP 55 of 11 mtr long including painting of pole with one coat red oxide primer & two coats of aluminum paint & emedded portion shall be painted with two coat of black bituminous paint all as specified and directed. Note : Pole shall be numbered with yellow shade on black base using synthetic enamel paint having height of words exceeding 5 cm complete all as specified and as directed.
Supply & fix FRP junction box, outside dimension 430x265x170 mm,IP65 protection with plain wall for cable of size 10sqmm ,size 126x228x111mm (min)including 20mm connetor MCB 6Amp SP -01 No with suitable bus bar arrangements and fixing on pole with and including MS clamp, out of 25x3 mm MS flat iron,nut, bolts etc complete all as specified and directed
Supply and laying or fixing or passing in trenches/ on pole/ through pipes, 1100 volts grade XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured, heavy duty electric cable with stranded aluminium conductor of cross section area 70sqmm, 3.5 core including jointing materials such as cable glands & lugs etc Complete all as directed. ( Note : Excavation, earthwork, sand cushioning and cable protection shall be measurede and paid for separately.)
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 1.5m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Excavation in trenches, not exceeding 1.5m wide and exceeding 1.5m in depth but n exc 3 metre, for foundation, for laying of pipe, cable etc or n. exc.10 Sqm on plan and n. exc. 3m in depth for shafts, cesspits, manholes, pier holes, etc and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick of excavated soil complete all as specified and as directed. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
Removal of excavated material (spoil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
Supply and laying Sand cushioning to under ground cable in trenches/existing cable trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable complete all as specified and directed by Engr in charge. ( Note : Punned thickness shall be measured for payment)
Supply and laying Brick covering with width equal to length of brick as mechanical protection to cable with well burnt sub class ‘B’ bricks laid dry flat complete all as specified and directed by Engr in charge.
M & L Plain Cement Concrete 1:3:6 type C-2 (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
M & L Plain Cement Concrete 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping of poles and including necessary form work, finished the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for GI Tubes, 40 mm dia, light grade, galvanised, with all fittings and fixtures, laid in trenches for protection of cable in road /drain crossing complete all as specified and as directed.
Schedule of credit amount of Rs. 36857.00 to be deducted during AOC
M/S Modern builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .