Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹65.1 LAccepted-AOC | ₹65.1 L Quoted ₹60.4 L | L1 | Accepted-AOC L1 Agency |
| 2 | L2₹64.9 L+₹4.4 L (7.33%)Rejected-Finance | ₹64.9 L+₹4.4 L (7.33%) | L2 | Rejected-Finance L2 Bidder |
| 3 | L3₹68.0 L+₹7.6 L (12.5%)Rejected-Finance | ₹68.0 L+₹7.6 L (12.5%) | L3 | Rejected-Finance L3 Bidder |
| 4 | L4₹69.8 L+₹9.4 L (15.5%)Rejected-Finance 605 POST RAJBATI C O NIKHIL KUMAR GHOSH BABURBAG KALITALA VILLAGE TOWN BURDWAN CITY BARDHAMAN PURBA BARDHAMAN WEST BENGAL 713104 INDIA | PURBA BARDHAMAN | WEST BENGAL | 713104 | ₹69.8 L+₹9.4 L (15.5%) | L4 | Rejected-Finance L4 Bidder. |
| 5 | L5₹73.7 L+₹13.3 L (22.0%)Rejected-Finance NH NAI BASTI ABOVE E D BANK NAI BASTI ROAD SATWARI JAMMU CANTT JAMMU JAMMU KASHMIR 180003 | JAMMU | JAMMU AND KASHMIR | 180003 | ₹73.7 L+₹13.3 L (22.0%) | L5 | Rejected-Finance L5 Bidder |
| Sl No | Description | Qty | Unit | JK Electric Engineers Pvt. Ltd. L6 | MATESHWARI ENTERPRISES L2 | Grun Umwelt Energy Pvt ltd L7 | E AND C ENGINEERING & CONSULTANCY SERVICES PRIVATE LIMITED L4 | M/S SURYA SHAKTI SOLAR SOLUTIONS L5 | Sunshine Renewables L3 | NEWSOL PV POWER PRIVATE LIMITED L1 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Sub Head I: DSITC of Grid connected Tin Roof Top mounted Solar Photovoltaic Power Plant: Design, Supply, Installation, Testing and Commissioning of Grid connected Tin Roof Top mounted Solar Photovoltaic Power Plant conforming to MNRE specifications as amended upto date, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 540 W or above, manufactured in India, conforming to IS 14286/ IEC 61215, IS/ IEC 61730-Part-1, IS/ IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 19%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 200-850 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz / 60Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from -20 degree C to 55 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. Auxiliary & Control Supply System, Data Logger System (with PC & hardware for local monitoring) & web based Remote Monitoring System, Plant Solar Radiation & Environment Monitoring System etc. as per technical specifications & approved system design. c) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. d) Lightning and surge voltage protection. e) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and DC cables between solar modules, main power cable to grid supply to PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. f) DLP 02 years. g) Carrying out Glint/Glare Analysis for safe flight operations, shadow analysis, clearance/approval from DISCOM, CEA and other statutory agencies, transportations & insurance of materials etc. and all other items/accessories/services which are required for successful commissioning of Solar Power plant complete as required and as per Special conditions of contract and technical specifications of the contract. | ||||||||||
| 1.10 | Location (1): Terminal Building Power House, Approx. Available Area: 7212 Sq. Ft | 100 | KWP | 51,500 ₹51,50,000 | 42,500 ₹42,50,000 | 58,000 ₹58,00,000 | 49,900 ₹49,90,000 | 48,000 ₹48,00,000 | 44,767 ₹44,76,700 | 40,000 ₹40,00,000 Lowest |
| 1.20 | Location (2): Aashina, AAI, Residential Colony Approx. Available Area: 1200 Sq. Ft | 20 | KWp | 52,500 ₹10,50,000 | 43,500 ₹8,70,000 | 50,000 ₹10,00,000 | 49,900 ₹9,98,000 | 49,500 ₹9,90,000 | 45,108 ₹9,02,160 | 40,000 ₹8,00,000 Lowest |
| 1.30 | Location (3): Chinar, AAI, Residential Colony Approx. Available Area: 800 Sq. Ft | 15 | KWp | 53,000 ₹7,95,000 | 44,500 ₹6,67,500 | 50,000 ₹7,50,000 | 49,900 ₹7,48,500 | 49,500 ₹7,42,500 | 45,108 ₹6,76,620 | 40,000 ₹6,00,000 Lowest |
| 2.00Sub Head II-: All Inclusive Comprehensive Maintenance (AICMC) All Inclusive Comprehensive Maintenance (AICMC) of Roof top Solar plant after successfully completion period of DLP (i.e. 2 Years ) as per BOQ item no-1.1, 1.2 & 1.3 of above including trouble shooting and breakdown maintenance etc.& monthly visit by service engineer as required as per recommendation of original manufacturer (OEM), good engineering practice & instructions of Engineer- In-Charge in line with tender scope as per terms and conditions specified in tender document.(Final measurement of capacity of respective year will be done based on installed capacity with considering annual degradation of 0.5% per year) | ||||||||||
| 2.10 | AICMC charges for 3rd year after DLP of 02 Years | 1 | Job per Year | 1,00,000 ₹77,220 | 1,50,000 ₹1,15,830 | 50,000 ₹38,610 | 49,999 ₹38,609.23 Lowest | 1,80,000 ₹1,38,996 | 1,52,250 ₹1,17,567.45 | 1,35,000 ₹1,04,247 |
| 2.20 | AICMC charges for 4th year after DLP of 02 Years | 1 | Job per Year | 1,00,000 ₹70,840 | 1,50,000 ₹1,06,260 | 50,000 ₹35,420 | 49,999 ₹35,419.29 Lowest | 1,80,000 ₹1,27,512 | 1,54,534 ₹1,09,471.89 | 1,36,000 ₹96,342.4 |
| 2.30 | AICMC charges for 5th year after DLP of 02 Years | 1 | Job per Year | 1,00,000 ₹64,990 | 1,50,000 ₹97,485 | 50,000 ₹32,495 | 49,999 ₹32,494.35 Lowest | 1,80,000 ₹1,16,982 | 1,56,852 ₹1,01,938.11 | 1,37,000 ₹89,036.3 |
| 2.40 | AICMC charges for 6th year after DLP of 02 Years | 1 | Job per Year | 1,00,000 ₹59,630 | 1,50,000 ₹89,445 | 50,000 ₹29,815 | 49,999 ₹29,814.4 Lowest | 1,80,000 ₹1,07,334 | 1,59,205 ₹94,933.94 | 1,38,000 ₹82,289.4 |
| 2.50 | AICMC charges for 7th year after DLP of 02 Years | 1 | Job per Year | 1,00,000 ₹54,700 | 1,50,000 ₹82,050 | 50,000 ₹27,350 | 49,999 ₹27,349.45 Lowest | 1,80,000 ₹98,460 | 1,61,593 ₹88,391.37 | 1,39,000 ₹76,033 |
Tender Value
₹93.2 L
EMD Value
₹2.8 L
Closing Date
1 Nov 2025, 11:00 amClosed
SR. MANAGER (ENGG ELECT)
Srinagar International Airport, Srinagar
Design, Supply, Installation, Testing and Commissioning of Solar power Plant at Srinagar International Airport, Srinagar.
2025_AAI_251985_1
AAI/SNR/ENGG-E/SOLAR/2025
Open Tender
Electrical Works
Item Rate
90 days
SRINAGAR AIRPORT
Refer NIT
15 documents required · 15 mandatory
₹1,180
₹2.8 L
12 Dec 2025
10 Oct 2025
3 Nov 2025
10 Oct 2025
1 Nov 2025
10 Oct 2025
10 Oct 2025 - 17 Oct 2025
Amount
Sub Head I: DSITC of Grid connected Tin Roof Top mounted Solar Photovoltaic Power Plant: Design, Supply, Installation, Testing and Commissioning of Grid connected Tin Roof Top mounted Solar Photovoltaic Power Plant conforming to MNRE specifications as amended upto date, consisting of Mono Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium / GI structure of suitable strength with following components complete as required:- a) Solar Photovoltaic Module of capacity 540 W or above, manufactured in India, conforming to IS 14286/ IEC 61215, IS/ IEC 61730-Part-1, IS/ IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 19%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years. b) Power Conditioning Unit (PCU) of 200-850 V DC Input voltage range and 415 V AC, three phase, 4 wire, 50Hz / 60Hz, output voltage suitable to generate AC Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from -20 degree C to 55 degree C. The PCU shall adjust the voltage and frequency level to suit the Grid Voltage Frequency. Auxiliary & Control Supply System, Data Logger System (with PC & hardware for local monitoring) & web based Remote Monitoring System, Plant Solar Radiation & Environment Monitoring System etc. as per technical specifications & approved system design. c) Fixing of Array junction box & Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required. d) Lightning and surge voltage protection. e) Connections & Interconnections by supplying & fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and DC cables between solar modules, main power cable to grid supply to PCU unit along with supplying & fixing of necessary channel/conduit lugs and other accessories etc. as required. f) DLP 02 years. g) Carrying out Glint/Glare Analysis for safe flight operations, shadow analysis, clearance/approval from DISCOM, CEA and other statutory agencies, transportations & insurance of materials etc. and all other items/accessories/services which are required for successful commissioning of Solar Power plant complete as required and as per Special conditions of contract and technical specifications of the contract.
Location (1): Terminal Building Power House, Approx. Available Area: 7212 Sq. Ft
Location (2): Aashina, AAI, Residential Colony Approx. Available Area: 1200 Sq. Ft
Location (3): Chinar, AAI, Residential Colony Approx. Available Area: 800 Sq. Ft
Sub Head II-: All Inclusive Comprehensive Maintenance (AICMC) All Inclusive Comprehensive Maintenance (AICMC) of Roof top Solar plant after successfully completion period of DLP (i.e. 2 Years ) as per BOQ item no-1.1, 1.2 & 1.3 of above including trouble shooting and breakdown maintenance etc.& monthly visit by service engineer as required as per recommendation of original manufacturer (OEM), good engineering practice & instructions of Engineer- In-Charge in line with tender scope as per terms and conditions specified in tender document.(Final measurement of capacity of respective year will be done based on installed capacity with considering annual degradation of 0.5% per year)
AICMC charges for 3rd year after DLP of 02 Years
AICMC charges for 4th year after DLP of 02 Years
AICMC charges for 5th year after DLP of 02 Years
AICMC charges for 6th year after DLP of 02 Years
AICMC charges for 7th year after DLP of 02 Years
AICMC charges for 8th year after DLP of 02 Years
AICMC charges for 9th year after DLP of 02 Years
AICMC charges for 10th year after DLP of 02 Years
MATESHWARI ENTERPRISES (BID ID -922230)
Sunshine Renewables (BID ID -919340)
E AND C ENGINEERING & CONSULTANCY SERVICES PRIVATE LIMITED (BID ID -918596)
M/S SURYA SHAKTI SOLAR SOLUTIONS (BID ID -922163)
JK Electric Engineers Pvt. Ltd. (BID ID -921588)
Grun Umwelt Energy Pvt ltd (BID ID -921592)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.03 MB
NITSolarsxr.pdf
Tender Documents • 3.95 MB
BOQ_289412.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .