Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H4₹82.6 L−₹37.1 L (31.0%)Accepted-AOC 0000 UNNAMED ROAD GAJIYA KANTIT VINDHYACHAL MIRZAPUR UTTAR PRADESH 231307 | MIRZAPUR | UTTAR PRADESH | 231307 | H4 | Accepted-AOC Contract awarded to M/s J K and Company | |
| 2 | H1₹1.2 CrRejected-Finance 19 1A BOSE PUKAR ROAD KASBA GROUND FLOOR KOLKATA 700042 | KOLKATA | KOLKATA | WEST BENGAL | 700042 | H1 | Rejected-Finance higher rates quoted than H4 | |
| 3 | H2₹97.5 L−₹22.2 L (18.5%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | H2 | Rejected-Finance higher rates quoted than H4 | |
| 4 | H3₹94.9 L−₹24.8 L (20.7%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | H3 | Rejected-Finance higher rates quoted than H4 | |
| 5 | Rejected-Technical 114 PIYALI APPARTMENT RAJDANGA GOLD PARK RAJDANGA GOLD PARK KOLKATA WEST BENGAL 700107 | KOLKATA | WEST BENGAL | 700107 | - | Rejected-Technical No, Value of executed work in MES is more than twice the tendering limit of B Class. |
| Sl No | Description | Qty | Unit | Intime Commotrade Pvt Ltd H1 | R D Bansal H2 | BRIJ MOHAN LAL AND CO. H3 | J.K & Company H4 |
|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for replacement solar photocvoltaic PV modules consisting of solar cells of output not less than 320 Wp, MNRE approved Polycrystalline /Mono crystalline silicon module complete all as specified and as directed.
Note: - (i) The type, capacity, grade of solar Photovoltaic PV modules shall be as per the existing at site or higher capacity and compatible with the system.
(ii) The defective solar photocvoltaic PV modules shall be replaced without any delay as per direction of GE. | 30 | Each | 10,100 ₹3,03,000 Lowest | 13,500 ₹4,05,000 | 13,150 ₹3,94,500 | 11,200 ₹3,36,000 |
| 2.00 | Supply, install, testing and commissioning three phase Grid Tie Inverters of capacity 50KW 1000V, efficiency not less than 97%, IP-65 protection with anti-islanding protection, compliance with MNRE and recommended standard of IEC-61683, IEC-60068, IEC-61000, IEC-61727 & IEC-62116 with remote monitoring enables proactive maintenance, 4Nos MPPT (28.5 Amps each) with voltage range 200-1000V, 12 Nos input string, Power factor-0.8-1, THDi less than 3%, Max efficiency 98.80% and MPPT efficiency 99.90%, with inbuilt protection (DC reverse polarity protection, short circuit protection, O/P over current & over voltage protection, insulation resistance monitoring, Residual current detection, surge protection, islanding protection, temperature protection, integrated DC switch), MC4 connectors with LCD display 4 Pins RS-485 connectors 2 RJ-45 connector & 2 group of terminal block, operating temperature (-) 25Oc to 60Oc, intelligent redundant fan cooling mode, noise less than 60 dBA and safety standard conforming to IEC 62109-1 & 2, AS-3100, EN 61000-6-1 & EN 61000-6-3 including taking out the existing one and depositing to MES store yard (No credit will be offered against this item) | 7 | Each | 3,12,100 ₹21,84,700 | 44,800 ₹3,13,600 Lowest | 4,55,150 ₹31,86,050 | 4,22,000 ₹29,54,000 |
| 3.00 | Material and labour for dismantling of existing inverter, fault diagnosis, repair/replacement of defective components, cleaning, testing, reinstallation, reconnection of DC/AC cables and commissioning, complete for proper operation complete all as specified and as directed. | 8 | Job | 1,10,200 ₹8,81,600 | 1,69,000 ₹13,52,000 | 1,00,100 ₹8,00,800 Lowest | 1,55,000 ₹12,40,000 |
| 4.00 | Supply and replacement of defective MC4/DC connectors including removal of old connector, crimping, proper termination and testing for safe and reliable connection complete all as specified and as directed. | 2,000 | Each | 301 ₹6,02,000 | 250 ₹5,00,000 | 130 ₹2,60,000 | 100 ₹2,00,000 Lowest |
| 5.00 | Material and labour for inspection, troubleshooting, repair and servicing of SCADA control panel including cards, communication modules, power supplies, wiring checks, cleaning, testing and restoration of full functionality complete all as specified and as directed. | 1 | Job | 6,52,101 ₹6,52,101 Lowest | 9,30,000 ₹9,30,000 | 9,25,610 ₹9,25,610 | 9,00,000 ₹9,00,000 |
| 6.00 | Routine servicing of UPS including cleaning, checking of control circuitry, cooling fans, terminals, protection devices, functional testing and performance verification complete all as specified and as directed. | 1 | Job | 25,000 ₹25,000 Lowest | 72,000 ₹72,000 | 1,28,900 ₹1,28,900 | 65,000 ₹65,000 |
| 7.00 | Supply and replacement of 12V, 100Ah SMF batteries including disconnecting old batteries, installation, terminal tightening, charging and testing complete all as specified and as directed (Old u/s Battery to be deposited in MES store yard. NO credit will be offered against this item). | 7 | Each | 78,900 ₹5,52,300 | 38,000 ₹2,66,000 | 32,750 ₹2,29,250 | 30,000 ₹2,10,000 Lowest |
| 8.00 | Supply, installation and replacement of 2V UPS batteries including removal of old batteries, interconnections, electrolyte check and testing complete all as specified and as directed (Old u/s Battery to be deposited in MES store yard. NO credit will be offered against this item). | 18 | Each | 90,000 ₹16,20,000 | 8,000 ₹1,44,000 | 7,550 ₹1,35,900 | 5,490 ₹98,820 Lowest |
| 9.00 | M&L for carrying out complete servicing, inspection, testing, calibration and preventive maintenance of 33 kV Vacuum Circuit Breaker including isolation of supply, thorough cleaning of breaker assembly, panels and insulators, and checking of vacuum interrupters, contacts and arc chambers. The work includes lubrication and adjustment of operating mechanism, tightening of all power and control connections, calibration of protection/relay settings, and testing of spring charging motor, trip/close coils and interlocks. Replacement of worn or defective small parts such as nuts, bolts, washers, springs, auxiliary contacts and minor consumables shall be carried out as required. Insulation resistance, contact resistance and functional operation tests shall be conducted to ensure safe, reliable and smooth performance, complete all as specified and as directed. | 2 | Job | 78,000 ₹1,56,000 | 67,000 ₹1,34,000 | 77,800 ₹1,55,600 | 60,000 ₹1,20,000 Lowest |
| 10.00 | Supply, installation, testing and commissioning of 33 kV, 3-phase, 4-wire, CT/PT operated, multifunction digital energy meter of approved make, suitable for HT metering, including dismantling of existing/defective meter, mounting of new meter, termination of control wiring, configuration, calibration, sealing and integration with existing metering/SCADA system, complete in all respects as per site requirements. | 1 | Each | 1,00,500 ₹1,00,500 Lowest | 2,25,000 ₹2,25,000 | 1,91,900 ₹1,91,900 | 2,00,000 ₹2,00,000 |
Tender Value
₹1.1 Cr
EMD Value
₹2.2 L
Closing Date
19 Mar 2026, 6:00 pmClosed
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DISTT- BURDWAN, STATE-WEST BENGAL PIN-713420
All as per BOQ
2026_MES_754477_1
8500-536/E8
Open Tender
Civil Works
Works
425 days
PANAGARH
As per tender documents
6 documents required · 6 mandatory
₹1,000
GE Panagarh
₹2.2 L
31 Mar 2026
27 Feb 2026
20 Mar 2026
27 Feb 2026
19 Mar 2026
13 Mar 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Material and labour for replacement solar photocvoltaic PV modules consisting of solar cells of output not less than 320 Wp, MNRE approved Polycrystalline /Mono crystalline silicon module complete all as specified and as directed.
Note: - (i) The type, capacity, grade of solar Photovoltaic PV modules shall be as per the existing at site or higher capacity and compatible with the system.
(ii) The defective solar photocvoltaic PV modules shall be replaced without any delay as per direction of GE. | 30 | Each | - | - |
| 2 | Material and labour for replacement Power Condition Units (PCU)/Inverter of capacity 50KW, String Inverters with maximum power point tracker /tracking (MPPT) feature certified by MNRE complete all as specified and as directed.
Note: - (i) The BER / defective Power Condition Units (PCU)/ Inverters, String Inverters shall only be replaced. | 7 | Each | - | - |
| 3 | Material and labour for dismantling of existing inverter, fault diagnosis, repair/replacement of defective components, cleaning, testing, reinstallation, reconnection of DC/AC cables and commissioning, complete for proper operation complete all as specified and as directed. | 8 | Job | - | - |
| 4 | Supply and replacement of defective MC4/DC connectors including removal of old connector, crimping, proper termination and testing for safe and reliable connection complete all as specified and as directed. | 2,000 | Each | - | - |
| 5 | Material and labour for inspection, troubleshooting, repair and servicing of SCADA control panel including cards, communication modules, power supplies, wiring checks, cleaning, testing and restoration of full functionality complete all as specified and as directed. | 1 | Job | - | - |
| 6 | Routine servicing of UPS including cleaning, checking of control circuitry, cooling fans, terminals, protection devices, functional testing and performance verification complete all as specified and as directed. | 1 | Job | - | - |
| 7 | Supply and replacement of 12V, 100Ah SMF batteries including disconnecting old batteries, installation, terminal tightening, charging and testing complete all as specified and as directed. | 7 | Each | - | - |
| 8 | Supply, installation and replacement of 2V UPS batteries including removal of old batteries, interconnections, electrolyte check and testing complete all as specified and as directed. | 18 | Each | - | - |
| 9 | M&L for carrying out complete servicing, inspection, testing, calibration and preventive maintenance of 33 kV Vacuum Circuit Breaker including isolation of supply, thorough cleaning of breaker assembly, panels and insulators, and checking of vacuum interrupters, contacts and arc chambers. The work includes lubrication and adjustment of operating mechanism, tightening of all power and control connections, calibration of protection/relay settings, and testing of spring charging motor, trip/close coils and interlocks. Replacement of worn or defective small parts such as nuts, bolts, washers, springs, auxiliary contacts and minor consumables shall be carried out as required. Insulation resistance, contact resistance and functional operation tests shall be conducted to ensure safe, reliable and smooth performance, complete all as specified and as directed. | 2 | Job | - | - |
| 10 | Supply, installation, testing and commissioning of 33 kV, 3-phase, 4-wire, CT/PT operated, multifunction digital energy meter of approved make, suitable for HT metering, including dismantling of existing/defective meter, mounting of new meter, termination of control wiring, configuration, calibration, sealing and integration with existing metering/SCADA system, complete in all respects as per site requirements. | 1 | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
PS536.pdf
Tender Documents • 0.84 MB
BOQ_845050.xls
BOQ • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .