Supply of LT Switchgear Package for KODERMA STPP as per NIT
2026_BHEL_64910_1
77/26/6145/MOH
Open Tender
Electrical Work/ Equipment
Lump-sum
730 days
KODERMA
As per NIT
5 documents required · 5 mandatory
₹0
₹40 L
Yes
NOIDA
11 Sept 2026
11 Sept 2026
3 Oct 2026
11 Sept 2026
3 Oct 2026
11 Sept 2026
11 Sept 2026 - 3 Oct 2026
21 Sept 2026
KODERMA THERMAL POWER STATION PHASE-II (2X800MW)
Enquiry No. 77/26/6145/MOH Dtd. 11.09.2026
S.No. ITEM NO. ITEM NAME UOM TOTAL QTY. RATING (A) BOARD NO. UNIT PRICE (EX-WORKS) Rs. TOTAL PRICE (EX-WORKS) Rs. FREIGHT % W.R.T TOTAL EX-WORKS (%) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EX-WORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL F.O.R SITE PRICE (Rs.) NO. OF PCC / ACB PANEL NO. OF MCC / ACDB / DCDB PANEL BOARD NAME PLATE, DESCRIPTION & RATING
1 506-0110316-00-A UNIT EMERGENCY SWBD-1 NOS. 1 3000 3DG 415 V UNIT-3 EMERGENCY PMCC 3DG, 3000A
2 506-0110040-00-A 220V MAIN DCDB-1 NOS. 1 1600 3FA 220 V UNIT-3 MAIN DCDB 3FA, 1600A
3 506-0110382-00-A Unit Boiler PMCC-1 NOS. 1 4000 3DA 415 V UNIT-3 BOILER SERVICE PMCC 3DA, 4000A
4 506-0110107-00-A BOILER V&D ACDB-1 NOS. 1 250 3HA 415 V UNIT-3 BLR. VALVE & DAMPER ACDB 3HA, 250A
5 506-0110092-00-A BOILER ACDB-1 NOS. 1 630 3HB 415 V UNIT-3 BOILER ACDB 3HB, 630A
6 506-0110419-00-A SOOT BLOWER MCC-1 NOS. 1 63 415 V UNIT-3 SOOT BLOWER MCC, 63A
7 506-0110387-00-A Unit Turbine PMCC-1 NOS. 1 4000 3DB 415 V UNIT-3 TURBINE SERVICE PMCC 3DB, 4000A
8 506-0110321-00-A UNIT SERVICE ACDB-1 NOS. 1 630 3QA 415 V UNIT-3 SERVICE ACDB 3QA, 630A
9 506-0110300-00-A TURBINE VALVE ACDB-1 NOS. 1 250 3KA 415 V UNIT-3 TURBINE VALVE DB 3KA, 250A
10 506-0110317-00-A UNIT EMERGENCY SWBD-2 NOS. 1 3000 4DG 415 V UNIT-4 EMERGENCY PMCC 4DG, 3000A
11 506-0110041-00-A 220V MAIN DCDB-2 NOS. 1 1600 4FA 220 V UNIT-4 MAIN DCDB 4FA, 1600A
12 506-0110383-00-A Unit Boiler PMCC-2 NOS. 1 4000 4DA 415 V UNIT-4 BOILER SERVICE PMCC 4DA, 4000A
13 506-0110108-00-A BOILER V&D ACDB-2 NOS. 1 250 4HA 415 V UNIT-4 BLR. VALVE & DAMPER ACDB 4HA, 250A
14 506-0110093-00-A BOILER ACDB-2 NOS. 1 630 4HB 415 V UNIT-4 BOILER ACDB 4HB, 630A
15 506-0110420-00-A SOOT BLOWER MCC-2 NOS. 1 63 415 V UNIT-4 SOOT BLOWER MCC, 63A
16 506-0110388-00-A Unit Turbine PMCC-2 NOS. 1 4000 4DB 415 V UNIT-4 TURBINE SERVICE PMCC 4DB, 4000A
17 506-0110322-00-A UNIT SERVICE ACDB-2 NOS. 1 630 4QA 415 V UNIT-4 SERVICE ACDB 4QA, 630A
18 506-0110301-00-A TURBINE VALVE ACDB-2 NOS. 1 250 4KA 415 V UNIT-4 TURBINE VALVE DB 4KA, 250A
19 506-0110179-00-A ESP SWBD NOS. 12 3000 3DC, 3DD, 3DE, 3DF,3DH, 3DJ 4DC, 4DD, 4DE, 4DF,4DH,4DJ UNIT-3 & UNIT-4 ESP PMCCs, 3000A
20 506-0110180-00-A ESP SWBD-1 NOS. 1 4000 3DK 415 V UNIT-3 ESP STANDBY PMCC 3DK, 4000A
21 506-0110181-00-A ESP SWBD-2 NOS. 1 4000 3DL 415 V UNIT-3 ESP STANDBY PMCC 3DL, 4000A
22 506-0110182-00-A ESP SWBD-3 NOS. 1 4000 4DK 415 V UNIT-4 ESP STANDBY PMCC 4DK, 4000A
23 506-0110183-00-A ESP SWBD-4 NOS. 1 4000 4DL 415 V UNIT-4 ESP STANDBY PMCC 4DL, 4000A
24 506-0110170-00-A ESP A/C & VENT MCC-1 NOS. 1 400 3TB 415 V UNIT-3 ESP HVAC MCC 3TB, 400A
25 506-0110165-00-A ESP & ID FAN AREA MCC-1 NOS. 1 400 3HC 415 V UNIT-3 ESP & ID FAN AREA MCC 3HC, 400A
26 506-0110171-00-A ESP A/C & VENT MCC-2 NOS. 1 400 4TB 415 V UNIT-4 ESP HVAC MCC 4TB, 400A
27 506-0110166-00-A ESP & ID FAN AREA MCC-2 NOS. 1 400 4HC 415 V UNIT-4 ESP & ID FAN AREA MCC 4HC, 400A
28 506-0110264-00-A STATION SERVICE SWBD.-1 NOS. 1 4000 0DA 415 V UNIT-3 STATION SERVICE PMCC 0DA, 4000A
29 506-0110077-00-A AIR CONDITIONING MCC NOS. 1 1600 0TA 415V CCR AIR CONDITIONING MCC 0TA, 1600A
30 506-0110331-00-A VENTILATION MCC-1 NOS. 1 630 3TA 415 V UNIT-3 VENTILATION MCC 3TA, 630A
31 506-0110241-00-A MISC. SERVICE MCC-1 NOS. 1 630 0QA 415 V UNIT -4 MISC. SERVICE MCC 0QA, 630A
32 506-0110079-00-A AIR WASHER MCC-1 NOS. 1 800 0SA 415 V UNIT -4 AIR WASHER MCC 0SA, 800A
33 506-0110265-00-A STATION SERVICE SWBD.-2 NOS. 1 4000 0DB 415 UNIT-4 V STATION SERVICE PMCC 0DB, 4000A
34 506-0110332-00-A VENTILATION MCC-2 NOS. 1 630 4TA 415 V UNIT-4 VENTILATION MCC 4TA, 630A
35 506-0110242-00-A MISC. SERVICE MCC-2 NOS. 1 630 0QB 415 V UNIT-4 MISC. SERVICE MCC 0QB, 630A
36 506-0110080-00-A AIR WASHER MCC-2 NOS. 1 800 0SB 415 V UNIT -4 AIR WASHER MCC 0SB, 800A
37 506-0110259-00-A SERVICE BLDG. MCC NOS. 1 1000 0SC 415 V SERVICE BUILDING AC MCC 0SC, 1000A
38 506-0110254-00-A RAW WATER SWBD. NOS. 1 1600 0DF 415 V RAW WATER PMCC 0DF, 1600A
39 506-0111019-00-A O&M STORE SWBD NOS. 1 250 0WB 415 V O & M STORE ACDB 0WB, 250A
40 506-0110044-00-A 220V OFFSITE DCDB NOS. 1 125 0FA 220 V RAW WATER AREA DCDB 0FA, 125A
41 506-0110190-00-A FUEL OIL P/H SWBD. NOS. 1 1600 0DE 415 V FOPH PMCC 0DE, 1600A
42 506-0110138-00-A COOLING TOWER SWBD.-1 NOS. 2 3000 3DQ, 4DQ 415 V IDCT UNIT-3/ 4 PMCC # 3DQ/ 4DQ, 3000A
43 506-0110139-00-A COOLING TOWER SWBD.-2 NOS. 2 3000 3DR, 4DR 415 V IDCT UNIT-3/ 4 PMCC # 3DR/ 4DR, 3000A
44 506-0110140-00-A COOLING TOWER SWBD.-3 NOS. 2 3000 3DT, 4DT 415 V IDCT UNIT-3/ 4 PMCC # 3DT/ 4DT, 3000A
45 506-0110141-00-A COOLING TOWER SWBD.-4 NOS. 2 3000 3DU, 4DU 415 V IDCT UNIT-3/ 4 PMCC # 3DU/ 4DU, 3000A
46 506-0111034-00-A SWITCHYARD SERVICE SWBD NOS. 1 1600 415V SWYD MAIN SWBD, 1600A
47 506-0110977-00-A 220V SWITCHYARD DCDB 1 NOS. 1 125 220 V SWITCHYARD DCDB, 125A
48 506-0110411-00-A SWITCHYARD EMERGENCY POWER DB NOS. 1 250 415V SWITCHYARD EMERGENCY POWER DB, 250A
49 506-0110983-00-A OUTDOOR SWGR # 1 NOS. 1 400 415 V UNIT-3 TRF AREA OUTDOOR SWGR, 400A
50 506-0110984-00-A OUTDOOR SWGR # 2 NOS. 1 400 415 V UNIT-4TRF AREA OUTDOOR SWGR, 400A
51 506-0110412-00-A SWITCHYARD OIL FILTRATION SWBD NOS. 1 400 SWITCHYARD OIL FILTRATION BOARD, 400A
52 506-0110985-00-A AC MCCB BOX NOS. 80 63
53 506-0110986-00-A DC MCCB BOX NOS. 20 63
2 506-0111038-00-A CONSOLE FOR HMI NOS. 4 REFER NOTE- B.2 & B.3
3 506-0111039-00-A LASER PRINTER (A4 SIZE) NOS. 4
4 506-0111040-00-A TABLE FOR PRINTER NOS. 4 REFER NOTE- B.3
B1 NUMERICAL RELAY, IMC AND ENERGY METERS -NETWORKING HARDWARE
1 ETHERNET SWITCH WITH IEC-61850 PROTOCOL IT SHALL BE PART OF SWITCHBOARD
2 506-0111041-00-A NETWORK LEVEL ETHERNET SWITCH (OF ADEQUATE PORTS) NOS. 4 NEAR DDCMIS END, INCLUDING COMPLETE DESIGN, ENGINEERING, SUPPLY, TESTING AND ERECTION & COMMISSIONING. EACH NO. (COMPLETE SET) SHALL BE SUITABLE FOR RECEIVING SIGNALS FROM EACH SWITCHGEAR LEVEL NETWORK/RING OF ETHERNET SWITCH's. BOTH SET OF NETWORK LEVEL ETHERNET SWITCH SHALL BE MOUNTED IN ETHERNET SWITCH BOX.
3 506-0111042-00-A CAT5e/CAT6 or Better Ethernet CABLE METERS 6000
4 506-0111043-00-A SIMPLEX FIBER OPTICAL CABLE FOR COMMUNICATION BETWEEN SWGR LEVEL ETHERNET SWITCH's (& THEIR RINGS) & NETWORK LEVEL ETHERNET SWITCH METERS 45000
5 506-0111044-00-A SIMPLEX FIBER OPTICAL CABLE PATCH CORD WITH CONNECTORS AT BOTH ENDS OF MINIMUM LENGTH 10 METERS NOS. 70
6 506-0111045-00-A HDPE CONDUIT (RODENT FREE) METERS 45000 USED FOR FIBER OPTICAL CABLE AT S.NO B1 (4)
7 506-0111046-00-A FO TERMINATION ACCESSORIES AT BIDDER'S SUPPLIED EQUIPMENT END UNDER THIS PACKAGE NOS. 1 ANNEXURE-1_TYPICAL SWITCHGEAR RELAY NETWORK ARCHITECTURE FOR SCOPE AND TERMINAL POINT
8 506-0111047-00-A LAPTOP PC WITH LICENCED VERSION SOFTWARE, HARDWARE FOR RELAY, IMC & ENERGY METERS PARAMETERISATION NOS. 5
9 506-0111048-00-A INTERFACE CABLE WITH SUITABLE CONNECTING PORT AT BOTH END FOR CONNECTION OF NUMERICAL RELAY/ ENERGY METERS FRONT PORT TO THE LAPTOP NOS. 55 EACH CABLE OF LENGTH AT LEAST 5M
10 506-0111049-00-A INTERFACE CABLE WITH SUITABLE CONNECTING PORT AT BOTH END FOR CONNECTION OF IMCC FRONT PORT TO THE LAPTOP NOS. 20 EACH CABLE OF LENGTH AT LEAST 5M
B2 NETWORKING HARDWARE FOR WIRELESS TEMPERATURE MONITORING SENSOR
1 506-0111053-00-A COMPLETE NETWORKING HARDWARE (EXCEPT CABLE & TERMINATION ACCESSORIES) NEAR SWITCHGEAR END FOR COMMUNICATION BETWEEN WIRELESS TEMPERATURE RECEIVER END & DDCMIS/HMI FOR TEMPERATURE MONITORING SYSTEM :- FOR TWO SET OF SWITCHBOARDS- a. FIRST SET- 3DA, 3DB & 3DG b. SECOND SET- 4DA, 4DB & 4DG NOS. 2 INCLUDING COMPLETE DESIGN, ENGINEERING AND SUPPLY. 1 NO. = 1 COMPLETE SET IS FOR EACH UNIT (CONSISTS OF 3 SWITCHBOARDS)
2 506-0111054-00-A SPECIAL CABLE(TWISTED PAIR/ CAT/ OPTICAL FIBRE CABLE OR AS APPLICABLE) INCLUDING TERMINATION ACCESSORIES FOR COMMUNICATION BETWEEN SWITCHGEAR & DDCMIS/HMI FOR TEMPERATURE MONITORING SYSTEM :- FOR TWO SET OF SWITCHBOARDS- a. FIRST SET- 3DA, 3DB & 3DG b. SECOND SET- 4DA, 4DB & 4DG NOS. 2 INCLUDING COMPLETE DESIGN, ENGINEERING AND SUPPLY. 1 NO. = 1 COMPLETE SET IS FOR EACH UNIT (CONSISTS OF 3 SWITCHBOARDS)
C TOOLS & TACKLE
1 506-0111055-00-A ACB RACKING HANDLE NOS. 30
2 506-0110283-00-A TELESCOPIC TROLLY (TROLLEY FOR ACB HANDLING) NOS. 20
3 506-0111056-00-A DOOR KEY NOS. 100
4 506-0111057-00-A RELAY TEST EQUIPMENT NOS. 2
5 506-0111058-00-A MODULE RACKING HANDLE NOS. 30
D SITE MODIFICATION
1 506-0111059-00-A LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR SKILLED TECHNICIAN (EXCEPT DAILY CHARGES) VISITS 15 0 REFER NOTE D.1 TO D.4
2 506-0111060-00-A LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SKILLED TECHNICIAN DAYS 60 0 REFER NOTE D.1 TO D.4
3 506-0111061-00-A LUMP SUM ALL INCLUSIVE CHARGES PER VISIT FOR SERVICE ENGINEER (EXCEPT DAILY CHARGES) VISITS 15 0 REFER NOTE D.1 TO D.4
4 506-0111062-00-A LUMP SUM ALL INCLUSIVE DAILY CHARGES FOR SERVICE ENGINEER DAYS 60 0 REFER NOTE D.1 TO D.4
E NUMERICAL RELAY, IMCC, ENERGY METERS, WIRELESS TEMPERATURE MONITORING & HMI SYSTEMS - COMMISSIONING CHARGES (AS PER ANNEXURE-E) SET 1 0 AS PER ANNEXURE-E
F E&C SPARES (AS PER ANNEXURE-F) SET 1 AS PER ANNEXURE-F
G MANDATORY SPARES (AS PER ANNEXURE-G) SET 1 AS PER ANNEXURE-G
GRAND TOTAL (Evaluation Price shall be Ex-works + Freight)
A.1 TO CALCULATE THE SWITCHBOARD PRICES, REFER DETAILED BOARD WISE BOM AND MODULE WISE BOM, ANNEXURE-A.1 AND ANNEXURE-A.2 OF TECHNICAL DATA PART-A OF TECHNICAL SPECIFICATION (PE-TS-519-506-E002) RESPECTIVELY.
A.2 BIDDER HAS TO QUOTE FOR THE FOLLOWING ALONG WITH THE BID:
i HMI SYSTEM: AS PER SR. NO. B ABOVE.
ii NETWORKING HARDWARE FOR NUMERICAL RELAYS, IMC AND ENERGY METERS AS PER SR. NO. B1 & FOR WIRELESS TEMPERATURE MONITORING SYSTEM AS PER SR. NO. B2 ABOVE
iii NUMERICAL RELAY, IMCC, WIRELESS TEMPERATURE MONITORING & HMI SYSTEM COMMISSIONING: AS PER ANNEXURE-E
iv TOOLS & TACKLES: AS PER SR. NO. C ABOVE.
v SITE MODIFICATION CHARGES: AS PER SR. NO. D (1 TO 5) ABOVE.
vi E & C SPARES: AS PER ANNEXURE-F
vii MANDATORY SPARE: AS PER LIST IN ANNEXURE–G
viii BIDDER TO PROVIDE A SCHEDULE OF UNIT PRICES IN ACCORDANCE WITH THE LIST PROVIDED IN ANNEXURE-H
A.3 BIDDER TO ENSURE THAT SUMMATION OF PRICES (AS PER ANNEXURE-H) OF APPLICABLE MODULES (AS PER ANNEXURE A.1-BOARDWISE BOM) AND APPLICABLE PANELS (MENTIONED ABOVE BY THE BIDDER) OF A BOARD SHALL BE EQUIVALENT TO BOARD PRICE QUOTED ABOVE FOR THAT BOARD. VARIATION OF +/- 5% IS ACCEPTABLE IN THE DERIVED PRICE FROM THE BOARD PRICE QUOTED ABOVE.
A.4 ADDITION/ DELETION OF QUANTITIES SHALL BE APPLICALBE AT THE QUOTED PRICES. ALLOWABLE VARIATION IN QUANTITY AND PRICE SHALL BE AS PER NIT.
A.5 ALL LT PCC/ PMCC/MCC/ DBs SHALL BE SUPPLIED ALONGWITH THE INTEGRAL BASE FRAMES, FOUNDATION BOLTS, CABLE GLANDS & LUGS. PRICES FOR THE SAME SHALL BE BUILT IN THE SWITCHBOARD PRICE.
A.6 BIDDER IS REQUIRED TO PROVIDE THE QUANTITY OF PANELS CORRESPONDING TO EACH BOARD IN THE TABLE ABOVE WHEN SUBMITTING THEIR TECHNO-COMMERCIAL PROPOSAL.
A.7 IN CASE MODULE DOORS ARE PART OF MODULES, 2 NOS OF DUMMY MODULES OF EACH SIZE TO FILL IN MODULE BEING TAKEN OUT FOR MAINTENANCE PURPOSE SHALL BE PROVIDED IN EACH SWITCHGEAR ROOM (REFER ANNEXURE-3_TENTATIVE SWITCHGEAR LOCATION OF TECHNICAL SPECIFICATION PE-TS-519-506-E002), THESE DUMMY MODULES SHALL BE FITTED IN SWITCHBOARD AS VACANT MODULES HAVING NO CUT OUT ON BACK SIDE AND CABLE ALLEY SIDE. IN CASE DOOR IS HINGED TO THE PANEL, 2 NOS OF BLANKING PLATES OF EACH SIZE NEED TO BE PROVIDED. PRICES FOR THE SAME SHALL BE BUILT IN THE SWITCHBOARD PRICE.
A.8 NO ADDITIONAL PRICES SHALL BE PAID FOR PROTOTYPE PANELS, PRICES QUOTED ABOVE INCLUDES COST OF PROTOTYPE PANELS ALSO.
A.9 PVC SHALL BE APPLICABLE FOR THIS ENQUIRY FOR PMCC / PCC / MCC / ACBD / DCDB ONLY AS PER IEEMA CIRCULAR (https://ieema.org/wp-content/uploads/2020/07/lvswgr-jan-2019.pdf). PRICE VARIATION IS NOT APPLICABLE FOR THE FOLLOWING: i) AC MCCB BOX, DC MCCB BOX, 24V PDB, HMI SYSTEM, NUMERICAL RELAY, IMCC, ENERGY METERS AND WIRELESS TEMP MONITORING SYSTEM ii) NETWORKING HARDWARE FOR 24V PDB, HMI SYSTEM, NUMERICAL RELAY, IMCC, ENERGY METERS AND WIRELESS TEMP MONITORING SYSTEM. iii) NUMERICAL RELAY, IMCC, 24V PDB, ENERGY METERS, WIRELESS TEMP MONITORING AND HMI SYSTEM- COMMISSIONING iv) TOOLS & TACKLE, SITE MODIFICATION, E&C SPARES & MANDATORY SPARES.
A.10 IN UNIT ADDITION-DELETION PRICES (ANNEXURE-H), PRICES QUOTED FOR COMPONENTS SHALL BE REASONABLE AND AS PER LIST PRICE OF CONCERNED MANUFACTURERS.
B.1 REFER ANNEXURE-1_TYPICAL SWITCHGEAR RELAY & ENERGY METERS NETWORK ARCHITECTURE.
B.2 INDUSTRIAL MODULAR DESIGN CONSOLE (FURNITURE I.E. TABLE WITH DRAWER & SWIVEL COMPUTER CHAIR) SHALL BE PROVIDED. EACH CONSOLE SHALL HAVE SPACE FOR KEEPING AN ADDITIONAL PC.
B.3 MAKE AND COLOR SHADE OF FURNITURE SHALL BE DECIDED DURING DETAIL ENGINEERING. FURNITURE COLOR SHADE SHOULD MATCH WITH CONTROL ROOM FURNITURE.
B.4 BHEL WILL PROVIDE UPS REDUNDANT FEEDER AT ONE LOCATION NEAR TO EWS LOCATION. FURTHER DISTRIBUTION OF UPS SUPPLY (FOR HMI, NETWORK SWITCH ETC.) ALONG WITH UPS DB SHALL BE IN THE SCOPE OF BIDDER.
B.5 FOR TESTING AND ERECTION & COMMISSIONING CHARGES FOR HMI- ITEMS, KINDLY REFER S.No.5 OF ANNEXURE-E
B1.1 REFER ANNEXURE- 3_TENTATIVE SWITCHBOARD LOCATION DETAIL FOR DISTANCE BETWEEN SWITCHGEAR AND NETWORK LEVEL ETHERNET SWITCH IN MAIN CONTROL ROOM.
B1.2 REFER ANNEXURE- 1_TYPICAL SWITCHGEAR RELAY NETWORK ARCHITECTURE FOR HMI REQUIREMENT.
B1.3 BIDDER TO PROVIDE ONE NO. OF EACH TYPE OF IMCC MODULE ALONG WITH Y-LINK TO BHEL ON RETURNABLE BASIS & COORDINATE WITH BHEL FOR CONDUCTING FAT FOR IMCC AS PER CUSTOMER SATISFACTION.
B2.1 REFER ANNEXURE- 3_TENTATIVE SWITCHBOARD LOCATION DETAIL FOR DISTANCE BETWEEN SWITCHGEAR AND MAIN CONTROL ROOM.
C.1 BIDDER HAS TO QUOTE FOR TOOLS AND TACKLES MENTIONED ABOVE. HOWEVER, BIDDER HAS TO INDICATE ANY SPECIAL TOOLS (IF REQUIRED).
D.1 AMOUNT PAYABLE FOR SKILLED TECHNICIAN PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. D(1) ABOVE + [ DAILY CHARGES AS PER SL. NO. D(2) ABOVE X NO. OF DAYS AT SITE ] (TO BE CERTIFIED BY BHEL SITE)
D.2 AMOUNT PAYABLE FOR SERVICE ENGINEER PER VISIT TO SITE = VISIT CHARGES AS PER SL. NO. D(3) ABOVE + [ DAILY CHARGES AS PER SL. NO. D (4) ABOVE X NO. OF DAYS AT SITE ] (TO BE CERTIFIED BY BHEL SITE)
D.3 AMOUNT PAYABLE FOR SITE MODIFICATION MATERIAL SHALL BE BASED ON THE ACTUAL COST OF THE MATERIALS UTILIZED. (TO BE CERTIFIED BY BHEL SITE). THE COST OF THE ACTUAL MATERIALS USED WILL BE DETERMINED USING THE UNIT RATE PROVIDED BY THE BIDDER IN THE ANNEXURE-H.
D.4 FOR LINE ITEMS D (1 TO 5), BIDDER TO DEPUTE ITS MANPOWER WITHIN 15 DAYS FROM THE DATE OF INTIMATION BY BHEL.
NUMERICAL RELAY, IMCC, ENERGY METERS, WIRELESS TEMPERATURE MONITORING & HMI SYSTEMS - COMMISSIONING CHARGES
S. No. ITEM NO. Item Description Qty. Unit UNIT PRICE (Ex-WORKS) Rs. TOTAL PRICE (Ex-WORKS) Rs. GST@18% ON EX-WORKS (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.) Remarks
1 506-0110403-00-C LUMP SUM ALL INCLUSIVE CHARGES PER NUMERICAL RELAY COMMISSIONING (INCLUDING CONVEYANCE TO SITE, BOARDING AND LODGING) 350 NOS.
2 506-0110404-00-C LUMP SUM ALL INCLUSIVE CHARGES PER IMC COMMISSIONING (INCLUDING CONVEYANCE TO SITE, BOARDING AND LODGING) 2500 NOS.
3 506-0110405-00-C LUMP SUM ALL INCLUSIVE CHARGES FOR WIRELESS TEMPERATURE MONITORING SYSTEM COMMISSIONING. FOR TWO LOT OF SWITCHBOARDS- a. FIRST LOT- 3DA, 3DB & 3DG SWITCHBOARDS b. SECOND LOT- 4DA, 4DB & 4DG SWITCHBOARDS 2 NOS. 1 NO.CONSISTS OF 3 SWITCHBOARD
4 506-0111083-00-C LUMP SUM ALL INCLUSIVE CHARGES PER ENERGY METER COMMISSIONING (INCLUDING CONVEYANCE TO SITE, BOARDING AND LODGING) 350 NOS.
5 506-0110407-00-C TESTING AND ERECTION & COMMISSIONING CHARGES FOR HMI- ITEMS AT SL. NO. B (1 TO 4) (HMI SYSTEM) 4 NOS. 1 NO. SHALL CONSIST OF TESTING AND ERECTION & COMMISSIONING OF ONE ITEM EACH OF SL. NO. B (1 TO 4) (HMI SYSTEM)
TOTAL OF ANNEXURE - E
1 AMOUNT PAYABLE FOR NUMERICAL RELAY COMMISSIONING = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.1 ABOVE x NO. OF RELAYS COMMISSIONED (SAME TO BE CERTIFIED BY BHEL SITE).
2 AMOUNT PAYABLE FOR IMCC COMMISSIONING = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.2 ABOVE x NO. OF IMCC COMMISSIONED (SAME TO BE CERTIFIED BY BHEL SITE).
3 AMOUNT PAYABLE FOR WIRELESS TEMPERATURE MONITORING SYSTEM COMMISSIONING FOR EACH UNIT (BMCC, TMCC and EMCC) = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.3 ABOVE (SAME TO BE CERTIFIED BY BHEL SITE).
4 FOR LINE ITEM 3, TESTING AND COMMISSIONING OF WIRELESS TEMPERATURE MONITORING SYSTEM FOR BMCC(3DA), TMCC (3DB) and EMCC(3DG) IS CONSIDERED AS 1 NO.SIMILARLY 3 BOARDS OF ANOTHER UNIT CONSIDERED AS 2ND NO.
5 AMOUNT PAYABLE FOR ENERGY METER COMMISSIONING = UNIT PRICE FOR COMMISSIONING CHARGES AS PER SL.NO.4 ABOVE x NO. OF ENERGY METERS COMMISSIONED (SAME TO BE CERTIFIED BY BHEL SITE).
6 APPROXIMATELY 15 NOs. OF NUMERICAL RELAYS, 15 NOs. OF ENERGY METERS AND/OR 50 NOs. OF IMCS CAN BE CONSIDERED BY BIDDER FOR COMMISSIONING IN EACH VISIT.
7 FOR LINE ITEM 1, 2, 3,4 BIDDER TO NOTE THAT TESTING, CONFIGURATION AND NETWORKING SETUP OF RELAY, IMC, ENERGY METERING SYSTEM, & TEMPERATURE MONITORING SYSTEM SHALL BE THE BIDDER’S RESPONSIBILITY COMPLETELY.
8 FOR LINE ITEM 5, BIDDER TO NOTE THAT ERECTION & COMMISSIONING, TESTING, CONFIGURATION AND NETWORKING SETUP OF HMI SYSTEM SHALL BE THE BIDDER’S RESPONSIBILITY COMPLETELY.
9 BIDDER TO COORDINATE WITH DCS SUPPPLIER (BHEL EDN) TO ENSURE SMOOTH AND EFFECTIVE COMMUNICATION BETWEEN NUMERICAL RELAY/ Y-LINK, ENERGY METERS AND DCS, AS WELL AS BETWEEN TEMPERATURE MONITORING SYSTEM AND DCS/HMI.
10 FOR LINE ITEMS 1 TO 5, BIDDER TO DEPUTE ITS MANPOWER WITHIN 15 DAYS FROM THE DATE OF INTIMATION BY BHEL.
S. No. Item no. Item / Component Qty. Unit UNIT PRICE (EX-WORKS) Rs. TOTAL PRICE (EX-WORKS) Rs. FREIGHT % W.R.T TOTAL EX-WORKS (%) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EX-WORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.)
1 FACTORY BUILT ASSEMBLIES (PCC/MCC/DB)
1.1 506-0110990-00-G Busbar supports (Horizontal)(1 set of 3) Nos. 1
1.2 506-0110991-00-G Primary isolating contacts (Bus side) of each rating(1 set of 3) Nos. 1
1.3 506-0110992-00-G Primary isolating contacts (Load side) of each rating (1 set of 3) Nos. 1
1.4 506-0110993-00-G Secondary isolating contacts of each rating (1 set of 3) Nos. 1
1.5 506-0110994-00-G Gaskets (each size) Meter 10
1.6 506-0110995-00-G Fixed Terminal (1way) Nos. 20
1.7 506-0110996-00-G Shrouds (for outgoing modules)-one for each physical size of module Nos. 1
1.8 Wire (for secondary wiring)
1.9 506-0111021-00-G Lugs (for 2.5 mm2 secondary wiring) Nos. 100
1.1 506-0110999-00-G Lugs (for 1.5 mm2 secondary wiring) Nos. 100
2 AIR CIRCUIT BREAKER (FOR EACH RATING)
2.1 506-0111000-00-G Shunt trip coil Nos. 5
2.2 506-0111001-00-G spring charging motor-1 motor of each rating Nos. 1
2.3 506-0111002-00-G closing coil Nos. 5
2.4 506-0111003-00-G Auxiliary contact/ switch Nos. 1
3 ISOLATING SWITCH
3.1 506-0111004-00-G Main contact kit for each rating (1 set of 3) Nos. 1
4 POWER CONTACTORS
4.1 506-0111005-00-G Contactor coil of each rating Nos. 1
4.2 506-0111006-00-G Contacts kit (main) for each rating (1 set of 3) Nos. 1
5 AUXILIARY CONTACTORS
5.1 506-0111007-00-G Complete unit with 2NO + 2NC contacts-1 no. of each rating/type Nos. 1
5.2 Contactor coils
a 506-0111008-00-G AC for each Aux. contactor rating Nos. 1
b 506-0111009-00-G DC for each Aux. contactor rating Nos. 1
6 506-0111010-00-G MCCB-1 no. of each rating/type Nos. 1
7 506-0111011-00-G MPCB-1 no. of each rating/type Nos. 1
8 506-0111012-00-G MCB-1 no. of each rating/type Nos. 1
a 506-0111013-00-G Actuator contacts Nos. 5
b 506-0111014-00-G Element Nos. 5
10 INDICATING LAMPS
a 506-0111015-00-G Complete unit Nos. 10
b 506-0111016-00-G Lens (assorted) Nos. 10
11.1 506-0111017-00-G Selector & control switch (each type) Nos. 1
11.2 506-0111018-00-G Connecting cable between CT and IMCC of appropriate length Nos. 50
11.3 506-0111019-00-G Connecting cable between VT and IMCC of appropriate length Nos. 50
11.4 506-0111020-00-G IMC Display HMI cable of Appropriate length Nos. 50
TOTAL OF ANNEXURE - F
MANDATORY SPARES
S.no. ITEM NO. Item Description Unit Quantity Unit Price Rs. Total Price Rs. FREIGHT % W.R.T TOTAL EX-WORKS (%) FREIGHT AMOUNT (Rs.) TOTAL PRICE (EX-WORKS + FREIGHT) (Rs.) GST@18% ON EX-WORKS + FREIGHT (Rs.)(mailto:GST@18%25%20ON%20EX-WORKS%20+%20FREIGHT%20(Rs.)塹ᴻ䡿ⲯ嶂藄挧ꮥ) TOTAL FOR SITE PRICE (Rs.)
1 506-0111064-00-B Complete breaker of each rating Nos. 10
2 506-0111065-00-B Numerical Relays of each type Nos. 5
3 506-0111066-00-B Auxiliary Relays of each type Nos. 10
4 506-0111067-00-B Horizontal busbar support Insulators of each type Nos. 12
5 506-0111068-00-B Vertical busbar dropper support insulators of each type Nos. 12
6 506-0111069-00-B Current transformer of each type & ratio Nos. 3
7 506-0111070-00-B Voltage transformer of each type & ratio Nos. 3
8 506-0111071-00-B Control supply transformer of each type & rating Nos. 3
9 506-0111072-00-B Power Contactor of each type and rating Nos. 10
10 506-0111073-00-B Coil for above contactor for each type and rating Nos. 10
11 506-0111074-00-B MCCBs (equally divided for all ratings) Nos. 40
12 506-0111075-00-B MPCBs (equally divided for all ratings) Nos. 40
13 506-0111076-00-B Closing coil of each type of each rating Nos. 10
14 506-0111077-00-B Trip coil of each type of each rating Nos. 10
15 506-0111078-00-B Aux contact set of each type and Rating Sets. 6
16 506-0111079-00-B Fixed contact set of each type & rating Sets. 3
17 506-0111080-00-B Moving contact set of each type & rating Sets. 3
18 506-0111081-00-B Maintenance tools and accessories for maintenance of LT MCC Nos. 2
TOTAL OF ANNEXURE G =
MODULE UNIT PRICE
S.No. Item Description Quantity Unit Price (INR) Remarks
1 INCOMING FEEDER UNIT
a) ACB Incomer to PCC/PMCC from Trafo. - Module Type DAET (I/C)
b) ACB Incomer to MCC - Module Type DAE (I/C)
c) ACB Incomer to Emergency Board - Module Type DG(I/C)
d) MCCB Incomer for MCC / ACDB – Module Type E3 (I/C)
63A – Fixed Type 1
125A – Fixed Type 1
160A – Fixed Type 1
200A – Fixed Type 1
250A – Fixed Type 1
300A – Fixed Type 1
400A – Fixed Type 1
63A – Drawout Type 1
125A – Drawout Type 1
160A – Drawout Type 1
200A – Drawout Type 1
250A – Drawout Type 1
300A – Drawout Type 1
400A – Drawout Type 1
e) MCCB Incomer with contactor changeover – Module Type CC
16A – Fixed Type 1
32A – Fixed Type 1
63A – Fixed Type 1
125A – Fixed Type 1
200A – Fixed Type 1
250A – Fixed Type 1
300A – Fixed Type 1
400A – Fixed Type 1
16A – Drawout Type 1
32A – Drawout Type 1
63A – Drawout Type 1
125A – Drawout Type 1
200A – Drawout Type 1
250A – Drawout Type 1
300A – Drawout Type 1
400A – Drawout Type 1
f) 220V DCDB Incomer from charger - Module type CH (I/C)
50A – CH Fixed Type 1
100A – CH Fixed Type 1
125A – CH Fixed Type 1
150A – CH Fixed Type 1
200A – CH Fixed Type 1
300A – CH Fixed Type 1
400A – CH Fixed Type 1
450A – CH Fixed Type 1
500A – CH Fixed Type 1
630A – CH Fixed Type 1
800A – CH Fixed Type 1
1000A – CH Fixed Type 1
1250A – CH Fixed Type 1
1600A – CH Fixed Type 1
50A – CH Drawout Type 1
100A – CH Drawout Type 1
125A – CH Drawout Type 1
150A – CH Drawout Type 1
200A – CH Drawout Type 1
300A – CH Drawout Type 1
400A – CH Drawout Type 1
450A – CH Drawout Type 1
500A – CH Drawout Type 1
630A – CH Drawout Type 1
800A – CH Drawout Type 1
1000A – CH Drawout Type 1
1250A – CH Drawout Type 1
1600A – CH Drawout Type 1
g) 220V DCDB Incomer from battery - Module type DB (I/C)
50A – DB Fixed Type 1
100A – DB Fixed Type 1
125A – DB Fixed Type 1
150A – DB Fixed Type 1
200A – DB Fixed Type 1
300A – DB Fixed Type 1
400A – DB Fixed Type 1
450A – DB Fixed Type 1
500A – DB Fixed Type 1
630A – DB Fixed Type 1
800A – DB Fixed Type 1
1000A – DB Fixed Type 1
1250A – DB Fixed Type 1
1600A – DB Fixed Type 1
50A – DB Drawout Type 1
100A – DB Drawout Type 1
125A – DB Drawout Type 1
150A – DB Drawout Type 1
200A – DB Drawout Type 1
300A – DB Drawout Type 1
400A – DB Drawout Type 1
450A – DB Drawout Type 1
500A – DB Drawout Type 1
630A – DB Drawout Type 1
800A – DB Drawout Type 1
1000A – DB Drawout Type 1
1250A – DB Drawout Type 1
1600A – DB Drawout Type 1
2 BUSCOUPLER UNIT
a) ACB Buscoupler to PCC/PMCC/MCC - Module Type DAET/ DAE (B/C)
b) MCCB Buscoupler for MCC / ACDB – Module Type E3 (B/C)
63A – Fixed Type 1
125A – Fixed Type 1
160A – Fixed Type 1
200A – Fixed Type 1
250A – Fixed Type 1
300A – Fixed Type 1
400A – Fixed Type 1
63A – Drawout Type 1
125A – Drawout Type 1
160A – Drawout Type 1
200A – Drawout Type 1
250A – Drawout Type 1
300A – Drawout Type 1
400A – Drawout Type 1
c) 220V DCDB buscoupler - Module Type - DC
50A – DC Fixed Type 1
100A – DC Fixed Type 1
125A – DC Fixed Type 1
150A – DC Fixed Type 1
200A – DC Fixed Type 1
300A – DC Fixed Type 1
400A – DC Fixed Type 1
450A – DC Fixed Type 1
500A – DC Fixed Type 1
630A – DC Fixed Type 1
800A – DC Fixed Type 1
1000A – DC Fixed Type 1
1250A – DC Fixed Type 1
1600A – DC Fixed Type 1
50A – DC Drawout Type 1
100A – DC Drawout Type 1
125A – DC Drawout Type 1
150A – DC Drawout Type 1
200A – DC Drawout Type 1
300A – DC Drawout Type 1
400A – DC Drawout Type 1
450A – DC Drawout Type 1
500A – DC Drawout Type 1
630A – DC Drawout Type 1
800A – DC Drawout Type 1
1000A – DC Drawout Type 1
1250A – DC Drawout Type 1
1600A – DC Drawout Type 1
d) 220V DCDB TIE - Module Type - HD
50A – HD Fixed Type 1
100A – HD Fixed Type 1
125A – HD Fixed Type 1
150A – HD Fixed Type 1
200A – HD Fixed Type 1
300A – HD Fixed Type 1
400A – HD Fixed Type 1
450A – HD Fixed Type 1
500A – HD Fixed Type 1
630A – HD Fixed Type 1
800A – HD Fixed Type 1
1000A – HD Fixed Type 1
1250A – HD Fixed Type 1
1600A – HD Fixed Type 1
50A – HD Drawout Type 1
100A – HD Drawout Type 1
125A – HD Drawout Type 1
150A – HD Drawout Type 1
200A – HD Drawout Type 1
300A – HD Drawout Type 1
400A – HD Drawout Type 1
450A – HD Drawout Type 1
500A – HD Drawout Type 1
630A – HD Drawout Type 1
800A – HD Drawout Type 1
1000A – HD Drawout Type 1
1250A – HD Drawout Type 1
1600A – HD Drawout Type 1
3 ACB outgoing supply feeder - Module Type DAE (O/G)/DAE-TIE
4 ACB outgoing motor feeder - Module Type DM/PM/AM (controlled from DDCMIS/PLC/ATRS)
5 MCCB outgoing supply feeders
a) Module Type E3(O/G)
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
160A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
300A - Fixed type 1
400A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
160A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
300A - Drawout Type 1
400A - Drawout Type 1
b) Module Type E3-TP (O/G)
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
160A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
300A - Fixed type 1
400A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
160A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
300A - Drawout Type 1
400A - Drawout Type 1
c) Module Type ES3 (O/G)
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
160A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
400A - Fixed type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
160A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
400A - Drawout Type 1
d) 2-ph feeder Module Type E2(O/G)
100A - Fixed type 1
160A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
300A - Fixed type 1
400A - Fixed type 1
100A - Drawout Type 1
160A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
300A - Drawout Type 1
400A - Drawout Type 1
e) Double pole 1-ph feeder Module Type E1(O/G)
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
f) 3-Ph MCCB controlled outgoing contactor feeder with IMC Module Type EA3(O/G)
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
400A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
400A - Drawout Type 1
g) 3-Ph MCCB controlled outgoing contactor feeder with IMC Module Type EA3-H (O/G)
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
400A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
400A - Drawout Type 1
h) 3-Ph MCCB controlled outgoing contactor feeder without IMC Module Type ET3(O/G)
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
400A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
400A - Drawout Type 1
i) 1-Ph MCCB controlled outgoing contactor feeder Module Type EA1(O/G)
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
j) 220V DC Outgoing MCCB Type (X) Feeder
16A - Fixed type 1
32A - Fixed type 1
63A - Fixed type 1
100A - Fixed type 1
125A - Fixed type 1
200A - Fixed type 1
250A - Fixed type 1
300A - Fixed type 1
400A - Fixed type 1
600A - Fixed type 1
800A - Fixed type 1
16A - Drawout Type 1
32A - Drawout Type 1
63A - Drawout Type 1
100A - Drawout Type 1
125A - Drawout Type 1
200A - Drawout Type 1
250A - Drawout Type 1
300A - Drawout Type 1
400A - Drawout Type 1
600A - Drawout Type 1
800A - Drawout Type 1
6 DOL Motor Starter - Unidirectional Drive - Drawout Type
a) Module Type DK2 / PK2 / AK2 (controlled from DDCMIS/PLC/ATRS)
b) Module Type DK2-H / PK2-H / AK2-H ( Hardwired- controlled from DDCMIS/PLC/ATRS)
c) Module Type DK21 / PK21 / AK21 (controlled from DDCMIS/PLC/ATRS)
d) Module Type DK21-H / PK21-H / AK21-H ( Hardwired-controlled from DDCMIS/PLC/ATRS)
e) Module Type DK2E/PK2E/AK2E (Reacceleration) (controlled from DDCMIS/PLC/ATRS)
f) Module Type DK2E-H/PK2E-H/AK2E-H (Reacceleration) (Hardwired-controlled from DDCMIS/PLC/ATRS)
g) Module Type DK21E/PK21E/AK21E (Reacceleration) (controlled from DDCMIS/PLC/ATRS)
h) Module Type DK21E-H/PK21E-H/AK21E-H (Reacceleration) (Hardwired- controlled from DDCMIS/PLC/ATRS)
i) Module Type K2 (Controlled from LCP)
j) Module Type K21 (Controlled from LCP)
k) Module Type K3 (Controlled from LPBS)
l) Module Type K31 (Controlled from LPBS)
7 RDOL Motor Starter - Bidirectional Drive - Drawout Type
a) Module Type DN1/ PN1/ AN1 (controlled from DDCMIS/PLC/ATRS)
8.1 Rapping Motor (RM1) Module with IMC 1
8.2 Rapping Motor (RM2) Module with OLR 1
9 DUST DENSITY MONITOR (DDM) Module 1
10 HOPPER HEATER (HH) Module 1
11 SUPPORT INSULATOR HEATER (HI) Module 1
12 SHAFT INSULATOR HEATER (HS) Module 1
13 Ash Level Indicator (ALI) Module 1
14 ARECA MARSHALING (ARECA) Module 1
15 WAVE LEVEL TRANSMITTER (WLT) Module 1
16 MARSHALING MODULE FOR SSPB OF RAPPING MOTOR AND HOPPER HEATER FEEDBACK (MM) 1
17 WALL BLOWER Module 1
18 LR BLOWER Module 1
19 AH BLOWER Module 1
20 JAMMING RELAY Module 1
21 Wireless Temperature Sensor (WTS1) Module (In one ACB/PCC panel with single ACB) 1
22 Wireless Temperature Sensor (WTS2) Module (In one ACB panel with double ACB) 1
23 Wireless Temperature Sensor (WTS3) Module (In one Double front MCC panel) 1
24 Common Auxiliary Module
i Bus PT module for PCC/PMCC - G1 Type 1
ii Bus PT module for Emergency MCC - G2 Type 1
iii Bus PT module for MCC/ACDB - VM Type 1
iv Bus PT DCDB - S Type 1
b.1) 110V AC control supply module – Type CS (consisting of 415/110V control Trafo.)
b.2) 240 V AC control supply module – type CS (consisting of 415/240V control Trafo.)
b.3) 24V AC control supply module – Type CS (consisting of 415/24V control Trafo.)
c) 240V AC motor space heater module 1
d) 220V DC supply module (for receiving 220V DC supply) 1
e) 24V DC supply module 1
f) Alarm module 1
g) 240 V AC Panel Space heating supply module – type SH (consisting of 415/240V control Trafo.)
h) 240V AC SPACE HEATER SUPPLY MODULE- SHS 1
25 Empty Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar (4 Wire System)
a) PCC Panel (Single Front Drawout Type) Without Temperature Sensor
b) MCC Panel (Single Front Fixed Type )
c) MCC Panel (Single Front Drawout Type)
d) MCC Panel (Double Front Drawout Type)
e) ACDB Panel (Double Front Fixed Type)
f) 220V DCDB Panel (Single Front Fixed type) with 20kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1
UPTO 630A (with 630A VBB) 1
1000A (with 630A VBB) 1
1600A (with 630A VBB) 1
g) 220V DCDB Panel (Single Front Fixed type) with 40kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1
UPTO 630A (with 630A VBB) 1
1000A (with 630A VBB) 1
1600A (with 630A VBB) 1
h) 220V DCDB Panel (Double Front Fixed type) with 20kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1
UPTO 630A (with 630A VBB) 1
1000A (with 630A VBB) 1
1250A (with 630A VBB) 1
1600A (with 630A VBB) 1
i) 220V DCDB Panel (Double Front Fixed type) with 40kA, 1 second fault Level
UPTO 125A (with 125A VBB) 1
UPTO 630A (with 630A VBB) 1
1000A (with 630A VBB) 1
1250A (with 630A VBB) 1
1600A (with 630A VBB) 1
j) 48V DCDB Panel (Single Front Fixed type)
UPTO 125A (with 125A VBB) 1
UPTO 200A (with 200A VBB) 1
UPTO 630A (with 630A VBB) 1
k) 48V DCDB Panel (Double Front Fixed type)
UPTO 125A (with 125A VBB) 1
UPTO 200A (with 200A VBB) 1
UPTO 630A (with 630A VBB) 1
l) Empty ACB Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar
26 Empty Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar (3 Wire System)
a) PCC Panel (Single Front Drawout Type) Without Temperature Sensor
b) MCC Panel (Double Front Drawout Type)
c) ACDB Panel (Double Front Fixed Type)
d) Empty ACB Panel with Horizontal & Vertical Busbar, Support & Auxiliary Busbar
28 Unit Prices For Circuit Components
a) Air Circuit Breaker without releases
630A ACB, 4P, EDO, AC 1
800A ACB, 4P, EDO, AC 1
1000A ACB, 4P, EDO, AC 1
1250A ACB, 4P, EDO, AC 1
1600A ACB, 4P, EDO, AC 1
2000A ACB, 4P, EDO, AC 1
2500A ACB, 4P, EDO, AC 1
3000A ACB, 4P, EDO, AC 1
4000A ACB, 4P, EDO, AC 1
630A ACB, 3P, EDO, AC 1
800A ACB, 3P, EDO, AC 1
1000A ACB, 3P, EDO, AC 1
1250A ACB, 3P, EDO, AC 1
1600A ACB, 3P, EDO, AC 1
2000A ACB, 3P, EDO, AC 1
2500A ACB, 3P, EDO, AC 1
3000A ACB, 3P, EDO, AC 1
4000A ACB, 3P, EDO, AC 1
800A ACB, 2P, MDO, DC 1
1000A ACB, 2P, MDO, DC 1
1250A ACB, 2P, MDO, DC 1
1600A ACB, 2P, MDO, DC 1
b) MPCB, Short-Circuit Release
c) TP MCCB, 2NO+2NC AUX, FSC & O/L RELEASE
d) TP MCCB, 2NO+2NC AUX, ADJ S/C & O/L RELEASE
e) TP MCCB with LSIG release
f) TP MCCB - Motorized with LSIG release
g) Power contactor (AC) ( With 2NO & 2NC Minimum)
i) AC Aux. contactor With
j) DC Aux. contactor With
k) Protection Relay
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), STAND BY EARTH FAULT PROTECTION (51NS), RESTRICTED EARTH FAULT PROTECTION (64R), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), STAND BY EARTH FAULT PROTECTION (51NS), RESTRICTED EARTH FAULT PROTECTION (64R), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF), MEASUREMENT AND DISPLAY OF HARMONIC CONTECT OF VOLTAGE & CURRENT 1
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), RESTRICTED EARTH FAULT PROTECTION (64R), BUS NO VOLT, FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), SYNCHRONISING CHECK FUNCTION (25, CIRCUIT BREAKER FAILURE (50BF), DIFFERENTIAL PROTECTION (87) (HIGH IMPEDANCE), REVERSE POWER PROTECTION, DG NEUTRAL DISPLACEMENT (59), DG MONITORING, RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1
Numerical Relay for PHASE OVER CURRENT PROTECTION (50/51), EARTH FAULT PROTECTION (50N/51N), STALLING/ LOCKED ROTOR PROTECTION (50L/R), THERMAL OVERLAOD PROTECTION (49), NEGATIVE PHASE SEQUENCE PROTECTION (46), BUS NO VOLT, REPETATIVE START PROTECTION (66), FAULT LOCKOUT FUNCTION (86), UNDER VOLTAGE WITH TIMER (27M), MOTOR DIFFERENTIAL PROTECTION (87M), CIRCUIT BREAKER FAILURE (50BF), PHASE REVERSAL PROTECTION (46R), CURRENT UNBALANCE PROTECTION, RELAY SELF SUPERVISION, CIRCUIT BREAKER CONDITION MONITORING, TRIP CIRCUIT SUPERVISION (95), CURRENT TRANFORMER SUPERVISION, VOLTAGE TRANFORMER SUPERVISION, BREAKER CONTROL with I/L, DISTURBANCE RECORDING, FAULT RECORDING, EVENT RECORDING, MEASUREMENT FUNCTIONS (3I, Io, 3U, Uo, Hz, P, Q, E, PF) 1
OVERLOAD RELAY, NOMINAL VOLTAGE-48V DC, O/V VLTAGE SETTING-110%, 1/4NV, 1NO+1NC S/R 1
ELECTRONIC TYPE JAMMING RELAY 1
l) IMC & its modules for Unidirectional Drive
1.1 IMC Upto 5.5KW 1
1.2 Current Sensing Module for above (if not Integral in IMC Module) 1
2.1 IMC for 5.6 - 7.0KW 1
2.2 Current Sensing Module for above (if not Integral in IMC Module) 1
3.1 IMC for 7.1 - 13KW 1
3.2 Current Sensing Module for above (if not Integral in IMC Module) 1
4.1 IMC for 13.1 - 24KW 1
4.2 Current Sensing Module for above (if not Integral in IMC Module) 1
5.2 Current Sensing Module for above (if not Integral in IMC Module) 1
6.2 Current Sensing Module for above (if not Integral in IMC Module) 1
6.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1
7.1 IMC for 37.1 - 55KW 1
7.2 Current Sensing Module for above (if not Integral in IMC Module) 1
7.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1
8.2 Current Sensing Module for above (if not Integral in IMC Module) 1
8.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1
9.2 Current Sensing Module for above (if not Integral in IMC Module) 1
9.3 Voltage Sensing Module for above (if not Integral in IMC Module) 1
10 Expansion Module for IMC 1
ON DELAY TIMER, 0.5-5SEC., 220V DC, 2NO+2NC 1
ON DELAY TIMER, 1.0-10SEC. 220V DC, 2NO+2NC 1
240VAC ON DELAY TIMER(1-10SECNS)WITH 1NO 1
220VDC ON DELAY TIMER(.5-5SECS) WITH 1NO 1
220VDC 0N DELAY TIMER(0.5-5SECS)WITH 3NO 1
220VDC ON DELAY TIMER(1-10SECS) WITH 3NO 1
AC ammeter (Digital) 1
AC ammeter (Analog) linear scale 1
AC ammeter (Analog) compressed scale 1
DC ammeter (Digital) 1
DC ammeter (Analog) 1
DC ammeter with shunt and center zero 1
AC voltmeter (Digital) 1
DC voltmeter (Analog) 1
Wattmeter (3 Phase) 1
Wattmeter (1 Phase) 1
DIGITAL ENERGY METER 1
Frequency meter 1
Multifunction digital Energy meter with RS485 Port (0.2 Acc. Class) 1
Multifunction digital Energy meter with RS485 Port (0.5 Acc. Class) 1
Multifunction digital Energy meter with RS485 Port (1.0 Acc. Class) 1
ABT meter (0.2S Acc. Class) 1
o) Single Phase Preventor Relay 1
6A, 4P 415V AC 1
6A DP, 240V AC 1
10A DP, 240V AC 1
16A DP, 240V AC 1
32A DP, 240V AC 1
6A DP, 110V AC 1
10A DP, 110V AC 1
16A DP, 110V AC 1
32A DP, 110V AC 1
6A DP, 220V DC 1
10A DP, 220V DC 1
16A DP, 220V DC 1
6A SP, 240V AC 1
10A SP, 240V AC 1
16A SP, 240V AC 1
32A SP, 240V AC 1
6A SP, 110V AC 1
10A SP, 110V AC 1
16A SP, 110V AC 1
32A SP, 110V AC 1
6A SP, 220V DC 1
10A SP, 220V DC 1
16A SP, 220V DC 1
q) SWITCH & PUSH BUTTON
BREAKER CONTROL SWITCH, 16A,220V DC, 2CLOSE+2TRIP 1
DC ISOLATING SWITCH 16A,220V DC, DP, BASE MTG. 1
16A, 240V AC SELECTOR SWITCH 3WAY, 4POLE, FLUSH MTG 1
25A, 240V AC SELECTOR SWITCH 3WAY, 4POLE, FLUSH MTG 1
16A, 240V AC SELECTOR SWITCH 2WAY, 2POLE, FLUSH MTG 1
NORMAL/ TRIAL SEL. SWITCH, 2POLE , 2WAY, 10A 240V AC, FLUSH MTG, 1
MCC/ NORMAL/ TRIAL SEL. SWITCH, 2POLE ,3WAY, 10A 240V AC, FLUSH MTG 1
SWGR/ REMOTE SEL. SWITCH 3POLE 2WAY,16A 220V DC, FLUSH MTG 1
SWGR/ NORMAL/ TRIAL SEL. SWITCH, 3POLE, 3WAY, 16A 220V DC, FLUSH MTG. 1
NORMAL/ TRIAL SEL. SWITCH, 2POLE , 2WAY, 10A 240V AC, FLUSH MTG, LOCKABEL TYPE 1
MCC/ NORMAL/ TRIAL SEL. SWITCH, 2POLE ,3WAY, 10A 240V AC, FLUSH MTG, LOCKABEL TYPE 1
SWGR/ REMOTE SEL. SWITCH 3POLE 2WAY,16A 220V DC, FLUSH MTG.LOCKABLE TYPE 1
SWGR/ NORMAL/ TRIAL SEL. SWITCH, 3POLE, 3WAY, 16A 220V DC, FLUSH MTG., LOCKABLE TYPE 1
AMMETER SELECTOR SWITCH 1
VOLTMETER SELECTOR SWITCH 1
TOGGLE SWITCH 5A, 240V AC 1
AC SWITCH SPST-5A,240V AC 1
10A, 220V DC SWITCH 1
Door Limit switch 1
Ammeter selector switch 1
Voltmeter selector switch 1
Trip selector switch 1
2NO + 2NC Shrouded 1
1NO + 1NC Shrouded 1
2NO + 2NC Mushroom head stayput 1
2NO + 2NC Lockable type 1
r) Indicating Lamp Assembly (LED Type)
240V AC-GREEN 1
240V AC- AMBER 1
110V AC-GREEN 1
110V AC- AMBER 1
220V DC-WHITE 1
220V DC-GREEN 1
220V DC- AMBER 1
63.5V AC-YELLOW 1
63.5V AC-BLUE 1
ii) Protection CT (5P20)
iii) PS Class CT
t) Voltage Transformer
u) Toggle switch (16A) 1
v) Secondary Isolating Contact Block 1
w) Control Terminal (Fixed) 1
x) Control Terminal (Drawout) 1
y) Thermostat, Dial type 1
z) CONTROL TRANSFORMER
415/240V,CL-B, 1 KVA 1
415/240V,CL-B, 2KVA 1
415/240V,CL-B, 2.5KVA 1
415/240V,CL-B, 3KVA 1
415/240V,CL-B, 5KVA 1
415/240V,CL-B, 7.5KVA 1
415/240V,CL-B, 10KVA 1
415/110V,CL-B, 1 KVA 1
415/110V,CL-B, 2KVA 1
415/110V,CL-B, 2.5KVA 1
415/110V,CL-B, 3KVA 1
415/110V,CL-B, 5KVA 1
415/110V,CL-B, 7.5KVA 1
415/110V,CL-B, 10KVA 1
aa) 415/110V,CL-B, 10KVA
4-20mA Dual o/p, Aux sup 220V DC, 1A, Current Transducer 1
4-20mA Dual o/p, Aux sup 240V AC, 1A, Current Transducer 1
4-20mA Dual o/p, Aux sup 110V AC, 1A, Current Transducer 1
4-20mA Dual o/p, Aux sup 220V DC, VoltageTransducer, PTR 415/110V 1
4-20mA Dual o/p, Aux sup 240V AC, VoltageTransducer, PTR 415/110V 1
4-20mA Dual o/p, Aux sup 110V AC, VoltageTransducer, PTR 415/110V 1
4-20mA Dual o/p, Aux sup 220V DC, FrequencyTransducer, PTR 415/110V 1
4-20mA Dual o/p, Aux sup 220V DC, Input 0-75mV DC, Current Transducer-DC 1
4-20mA Dual o/p, Aux sup 240V AC, Input Voltage 0-220V DC, Voltage Transducer-DC 1
4-20mA Dual Output kW transducer 1
4-20mA Dual Output kVA transducer 1
4-20mA Dual Output PF transducer 1
4-20mA Dual Output Frequency transducer 1
ab) Interposing relay RE 302 or Eqvt with freewheeling diode & LED 1
ac) 3 PIN SOCKET - 5A, 110V AC, 3PIN 1
ad) SPACE HEATER 1
ae) NEUTRAL LINK WITH MOUNTING ASSEMBLY
20A FOR CONTROL CKT. & POWER CKT. UPTO 25A MCCB RATING 1
32A FOR 50A MCCB RATING 1
63A FOR 100A & 125A MCCB RATING 1
125A FOR 250A MCCB RATING 1
250A FOR 400A & 500A MCCB RATING 1
af) CASTLE KEY INTERLOCK FOR MCCB - 3LOCK+2KEY 1
ag) MECHANICAL INTERLOCK FOR POWER CONTACTOR
ah) ADDON BLOCK FOR CONTACTOR
ai) ISOLATOR WITH HANDLE
29 Connection from PMCC/MCC panel to PMCC/MCC panel (per meter length)
30 Cable Glands & Lugs:
a) Single Compression Cable Glands for cable sizes:
2C X 2.5 Sq. mm. 1
3C X 2.5 Sq. mm. 1
5C X 2.5 Sq. mm. 1
7C X 2.5 Sq. mm. 1
10C X 2.5 Sq. mm. 1
14C X 2.5 Sq. mm. 1
2C X 10 Sq. mm. 1
2C X 16 Sq. mm. 1
2C X 25 Sq. mm. 1
2C X 35 Sq. mm. 1
2C X 50 Sq. mm. 1
2C X 70 Sq. mm. 1
2C X 95 Sq. mm. 1
3C X 2.5 Sq. mm. 1
3C X 10 Sq. mm. 1
3C X 16 Sq. mm. 1
3C X 25 Sq. mm. 1
3C X 35 Sq. mm. 1
3C X 50 Sq. mm. 1
3C X 70 Sq. mm. 1
3C X 95 Sq. mm. 1
3C X 150 Sq. mm. 1
3C X 240 Sq. mm. 1
3C X 300 Sq. mm. 1
3.5C X 25 Sq. mm. 1
3.5C X 50 Sq. mm. 1
3.5C X 70 Sq. mm. 1
3.5C X 95 Sq. mm. 1
3.5C X 240 Sq. mm. 1
3.5C X 300 Sq. mm. 1
4C X 16 Sq. mm. 1
4C X 35 Sq. mm. 1
1C X 300 Sq. mm. 1
1C X 630 Sq. mm. 1
b) Double Compression Cable Glands for cable sizes:
2C X 2.5 Sq. mm. 1
3C X 2.5 Sq. mm. 1
5C X 2.5 Sq. mm. 1
7C X 2.5 Sq. mm. 1
12C X 2.5 Sq. mm. 1
16C X 2.5 Sq. mm. 1
2C X 10 Sq. mm. 1
2C X 16 Sq. mm. 1
2C X 25 Sq. mm. 1
2C X 35 Sq. mm. 1
2C X 50 Sq. mm. 1
2C X 70 Sq. mm. 1
2C X 95 Sq. mm. 1
3C X 2.5 Sq. mm. 1
3C X 10 Sq. mm. 1
3C X 16 Sq. mm. 1
3C X 25 Sq. mm. 1
3C X 35 Sq. mm. 1
3C X 50 Sq. mm. 1
3C X 70 Sq. mm. 1
3C X 95 Sq. mm. 1
3C X 150 Sq. mm. 1
3C X 240 Sq. mm. 1
3C X 300 Sq. mm. 1
3.5C X 25 Sq. mm. 1
3.5C X 50 Sq. mm. 1
3.5C X 70 Sq. mm. 1
3.5C X 95 Sq. mm. 1
3.5C X 240 Sq. mm. 1
3.5C X 300 Sq. mm. 1
4C X 16 Sq. mm. 1
4C X 35 Sq. mm. 1
1C X 300 Sq. mm. 1
1C X 630 Sq. mm. 1
c) Cable Lugs for sizes:
31.1 Thermal O/L relay with SPP - OLR
31.2 Heavy Duty Thermal O/L relay with SPP - OLR
32 Daily 8 hour rate deployed at site:
Engineer : (per day) 1
33 Module Name plate 1
34 Wires for Secondary wiring:
a) 1.5 Sq. mm. per meter 1
b) 2.5 Sq. mm. per meter 1
c) 4.0 Sq. mm. per meter 1
35 Control Terminal for Secondary wiring suitable for cable size:
36 Electrical Junction Boxes (for termination of 0.5 sqmm screened control cables)
37 Temperature Sensor for WIRELESS TEMPERATURE MONITORING SENSOR 1
38 Wireless Transmitter for WIRELESS TEMPERATURE MONITORING SENSOR 1
39 Wireless Receiver for WIRELESS TEMPERATURE MONITORING SENSOR 1
40 Additional components (except networking hardware mentioned inSr. No. B3 of BOQ) required for completeness of WIRELESS TEMPERATURE MONITORING SENSOR 1
41 DP MCCB, ADJ. SC & O/L Release:
TP MCCB motor duty type with S/C release:
TP MCCB ADJ S/C , O/L, E/F release:
45 SWITCH FUSE UNIT (DC) - DP along with fuse, link etc complete (suitable for 40kA fault current)
46 SWITCH FUSE UNIT (AC) - TP along with fuse, link etc complete
48 OLM, Profibus DP connector along with accessories (at Y-link end) for interface of Y-Link with DDCMIS. 1
SP ON/ OFF SWITCH FOR MOTOR SPACE HEATER OF BREAKER MOTOR FDR, 10A, 240V AC 1
4 POLE, 2 POSI., SELECTOR SWITCH FOR CONTROL TRF., 110V AC 1
EXTENDED ROTORY HANDLE 1
AUXILIARY CONTACT FOR MCCB 1C/O 1
TRIP CONTACT FOR MCCB 1C/O 1
CONTROL TERMINALS (DRAWOUT) 1
3 PIN INDUSTRIAL SOCKET & PLUG 1
ROTARY ON/OFF SWITCH 1
ELECTRONIC TIMER WITH 2C/O 1
CONTROL TRANSFORMER, DRY TYPE, CAST RESIN, 415/24V, INS. CL-B OR BETTER 1
LIMIT SWITCH (BREAKER) 1
Ethernet Switch with 16 Copper Ports & 4 FO ports 1
Ethernet Switch with 08 Copper Ports & 4 FO ports 1
Cat5e/ Cat6 Ethernet Cable 1
Fibre Optic Patch Cord (minimum length - 10metres) 1
9 WINDOWS ALARM ANNUNCIATION -1 1
ELECTRONIC HOOTER (96SQMM) 1
67 24V DC PDB - 16 WAYS 1
68 24V DC PDB - 32 WAYS 1
69 24V DC PDB - 64 WAYS 1
NOTE: The bidder should list the unit price for any additional modules, components, or items that are not mentioned in the above specifications but may be necessary to fulfill the customer's requirements.
ANNEXURE - II-COST OF WITHDRAWAL
SCHEDULE OF TECHNICAL AND COMMERCIAL DEVIATION
PROJECT:- 2 X 800 MW DVC Koderma TPS Phase-II
PACKAGE:-LT SWITCHGEAR
Enquiry No. 77/26/6145/MOH Dtd.11.09.2026
NAME OF VENDOR:-
TECHNICAL DEVIATIONS
COMMERCIAL DEVIATIONS
PARTICULARS OF BIDDERS/ AUTHORISED REPRESENTATIVE
NAME DESIGNATIONS SIGN & DATE
1. Cost of withdrawl of deviation will be applicable on the basic price (i.e. excluding taxes, duties & freight) only.
2. All the bidders have to list out all their Technical & Commercial Deviations (if any) in detail in the above format.
3. Any deviation not mentioned above and shown separately or found hidden in offer, will not be taken cognizance of.
4. Bidder shall submit duly filled unpriced copy of above format indicating "quoted" in "cost of withdrawl of deviation" column of the schedule above along with their Techno-commercial offer, wherever applicable. In the absence of same, such deviation(s) shall not be considered and offer shall be considered in total compliance to NIT.
5. Bidder shall furnish price copy of above format along with price bid.
6. The final decision of acceptance/ rejection of the deviations quoted by the bidder shall be at discretion of the Purchaser.
7. Bidders to note that any deviation (technical/commercial) not listed in above and asked after Part-I opening shall not be considered.
8. For deviations w.r.t. Credit Period, Liquidated damages, Firm prices if a bidder chooses not to give any cost of withdrawl of deviation loading as per Annexure-VII, will apply. For any other deviation mentioned in un-priced copy of this format submitted with Part-I bid but not mentioned in priced copy of this format submitted with Priced bid, the cost of withdrawl of deviation shall be taken as NIL.
9. Any deviation mentioned in priced copy of this format, but not mentioned in the un-priced copy, shall not be considered.
10. All techno-commercial terms and conditions of NIT shall be deemed to have been accepted by the bidder, other than those listed in unpriced copy of this format.
11. Cost of withdrawl is to be given seperately for each deviation. In no event bidder should club cost of withdrawl of more than one deviation else cost of withdrawl of such deviations which have been clubbed together shall be considered as NIL.
12. In case nature of cost of withdrawl (positive/negative) is not specified it shall be assumed as positive.
13. In case of descrepancy in the nature of impact (positive/ negative), positive will be considered for evaluation and negative for ordering.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.53 MB
Tendernotice_2.pdf
PDF • 14.38 MB
Tendernotice_3.pdf
PDF • 14.57 MB
Tendernotice_4.pdf
PDF • 15.47 MB
Tendernotice_5.pdf
PDF • 0.49 MB
SCC.pdf
Other Document • 4.14 MB
BOQcumpricescheduleFinal.xls
Additional Documents • 0.30 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .