Loading…
Loading…
Tender Value
₹23.5 Cr
EMD Value
₹5 L
Closing Date
3 Jun 2026, 5:00 pmClosed
MR Yognarayan sahu(DFLT)
CE(Raipur)
WIDENING AND UPGRADATION WORK OF PADAMPUR SARAIPALI SARSIWA ROAD (SH-16) ROAD ON KM 233 TO 256/6 = 22.10 K.M. I/C. CULVERTS AT DIST. MAHASAMUND.(MAHASAMUND DN.)
190754
NIT NO: 226/TC/2026-27
RESTRICTED TENDER
WORKS
12 days
CE(Raipur)
Required Past Technical Experience: AS PER NIT
Required Financial Turnover (in INR): AS PER NIT
Required Bid Capacity (in INR): AS PER NIT
17 documents required · 17 mandatory
Public Works Department (PWD)
WORKS
MR Yognarayan sahu(DFLT)
RESTRICTED TENDER
PERCENTAGE
A
CE(Raipur)
PWD Circle-2,Raipur
Mahasamund Division
120
12
No
0
190754
3 Jun, 2026 5:00:00 PM IST
8 Jun, 2026 10:00:00 AM IST
13 May, 2026 5:00:00 PM IST
NIT NO: 226/TC/2026-27
WIDENING AND UPGRADATION WORK OF PADAMPUR SARAIPALI SARSIWA ROAD (SH-16) ROAD ON KM 233 TO 256/6 = 22.10 K.M. I/C. CULVERTS AT DIST. MAHASAMUND.(MAHASAMUND DN.)
500000.00 INR
RTGS/CHALLAN (ONLINE) Internet Banking (ONLINE)
234898000.00
2
5 Jun, 2026 5:00:00 PM IST
234898000
AS PER NIT
AS PER NIT
AS PER NIT
0.00 INR
20d 23h 39m
17 documents required · 11 mandatory · 6 optional
₹0
₹5 L
12 May 2026
12 May 2026
8 Jun 2026
13 May 2026
3 Jun 2026
13 May 2026
5 Jun 2026
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 meters including removal and disposal of top organic soil not exceeding 150 mm in thickness if required and as per relevant clauses of section-200. A. In area of light jungle
Granular Sub-base as per Table:- 400-1 Construction of granular sub-base by providing graded Material, , carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface watering, rolling and compacting with vibratory power roller at OMC to achieve the desired density, complete as per clause401 Sub-base cum drainage layer or upper sub-base with Grading-V Material
Scarifying existing bituminous surface to a depth of 50 mm (Scarifying the existing bituminous road surface to a depth of 50 mm and disposal of scarified material with in all lifts and lead up to 1000 meters) as per clause 305.4.3.
Wet Mix Macadam (Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density as per clause 406.)
Prime coat (Providing and applying primer coat with oil based bitumen emulsion (SS-1, grade confirming to IS:8887) on prepared surface of granular Base including clearing of road surface and spraying primer using mechanical means as per clause 502. (i) on WBM/WMM surface @0.85 Kg/sqm.
Tack coat Providing and applying tack coat with bitumen emulsion (RS-1, grade confirming to IS:8887) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per clause 503. (ii)Granular surfaces treated with primes @ 0.30 kg /Sqm
Dense Bituminous Macadam (Providing and laying dense bituminous macadam with minimum 40-60 TPH capacity HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No.505 complete in all respects.) With sensor paver finisher for Grading-II(26.5 mm nominal size bitumen content 4.50%)
Bituminous Concrete (Providing and laying bituminous concrete with minimum 40-60 TPH capacity hot mix plant using crushed aggregates of specified grading, premixed with bituminous binder @ 5.0 to 6.0% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MORTH specification clause No. 507 complete in all respects) With sensor paver finisher for Grading II (13.2 mm nominal size) with bitumen 6.0 %
Providing and laying cement concrete for plain concrete/ reinforced concrete i/c form work, shuttering complete in as per drawings and specifications.( For Village roads) P.C.C. M-10
Providing and laying un-reinforced Cement Concrete without Dowel bars including formworks and expansion contraction & longitudinal joints as per design and as per IRC-62-2014, over a prepared base a per approved mix design and finishing to lines and grade as per Drawing for Pavement thickness less than 200mm in Low Volume Roads. PCC Grade M30 with minimum Cement Content @375kg/cum
Providing and fixing guard stones 200 x 200 x 900 mm made of precast RCC M-20 grade fixed at 300 mm into the ground in P.C.C. 1:3:6 blocks of size 400 x 400 x 400 mm and given two coats of paint with white and black bands including excavation.
Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia., across the road ( new construction ) , extending from drain to drain in cuts and toe of slopes to toe of slopes in fills, constructing head walls at both ends, providing a minimum fill of granular material over top and sides of RCC pipes as per IRC: 98- 2011, bedded on a 0.3 m thick layer of granular material free of rockpieces , outer to outer distance of pipes at least half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC:98-2011 and approved drawings. Single row for one utility service
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets . ) 600 mm dia
900mm equilateral triangle
800mm x600mm recctangular
With Aluminum Sheeting of 1.5mm Thickness. 600mm x600mm Square
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) 5th Kilometer stone (Precast)
Kilo Meter Stone (Reinforced cement concrete M15grade kilometer stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc) Ordinary Kilometer stone (Precast)
Hectometer stone (Precast)
Providing & Fixing Hazard Marker Type-2 Partial Retro Reflective Size 0.30 x 0.90M made of 16 gauge (1.6 mm) thick mild steel sheet Confirming to IS:2062 Painted with one cast of Zinc Chromate Stoving Primer and two coats of Black Stove Enamel (Oven Baked) paint with 10 cm bands of yellow Retro- Reflective Sheeting of Engineering Grade pasted a per IRC:79 including one MS angle Iron post of size 50x50x5 mm of 1.65 meter long duly painted with synthetic enameled paint block including bolts and fixing the same in M-15 concrete black of size 30x30x30cm, including transportation etc. Complete.
Supply and Installation of Road delineators (Road way Delineators). The structure shall be manufactured of mild steel with pure polyester powder coating in black colour with minimum thickness of 40 micron for protection against corrosion. The delineator shall have retro-reflective sheeting of white colour with Type-XI specifications as per IRC:67-2022 and ASTM D 4956 on both the faces to ensure the clear visibility of the road alignment during night time to achieve enhanced visibility of the curved portion of the road. To prevent complete vandalism of above, the reflective sheeting shall be housed with concealed edges. The delineator shall confirm to clause 3 of IRC:79-2019, it shall have an ellipsoidal or circular design and shall be 800 to 900 mm above the ground and shall extend 200 to 300 mm below the ground fixed in foundation of 300 x 300 x 400 mm size block of cement
Providing & Fixing tree studs in Square/ Round shape of 4” side/diameter made of 2 mm aluminum substrate (Confirming to IS:736 -Material Designation, 24345 or 1900) end reflective surface of High Intensity grade as specified in section 801.3 of MORT&H duly treated with HLVA and fixing the same with four Nos. high strength nails confirming to 1S:1367 on trees at site each.
Providing and fixing Raised Pavement Markers made of polycarbonate ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face and shall support a load of 16000 Kg tested in accordance to ASTM D 4280 type H and complying to specifications of category A of MORT&H (RW/NH-33023/10/97 -DO III Dtd. 11.06.1997). The pavement markers will be auto moulded by dual polymer shanks and must comply with all the MoRT&H specifications The height, width and length shall not exceed 50 mm, 100 mm and 100 mm respectively and with minimum reflective area of 13 Sq.cm. on each side and slope to the base shall be 35 +/-5 degree. The strength of detachment of the integrated cylindrical shanks (of diameter not less than 19 +/- 2 mmand height not less than 30+/- 2 mm) from the body is to be a minimum value of 500 kgf. Fixing will be by drilling holes on road for the shanks to go inside, without nails and using epoxy resin based adhesive and complete as directed by the Engineer-in-charge.
Construction of RCC Drain/Cover/Chamber (i) Excavation for drain (Earth work in excavation for drain/chamber as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.)
Construction of RCC Drain/Cover/Chamber (ii)Construction of RCC drain/chamber cover, placing in position, providing shuttering and concreting by using concrete mixer, compaction by vibration etc complete as per drawings and technical specifications excluding reinforcement. with RCC M-20
Supplying, Fitting and Placing un-coated HYSD bar Reinforcement in drain/cover/chamber complete as per Drawing and Technical Specifications.
Plain cement concrete complete as per drawing and Technical Specifications PCC Grade M 15
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Lime / Cement Concrete Lime Concrete, cement concrete grade M-10 and below
Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead upto 1000 meters and as per relevant clauses of section-200 in Lime / Cement Concrete Cement Concrete Grade M-15 & M-20
Removing all type of hume pipes and stacking within a lead upto 1000 meters including earthwork and dismantling of masonry works around pipes. Above 1000 mm dia
Excavation for Structures (Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material.) Ordinary soil Up to 3 m depth
Providing and laying Reinforced Cement Concrete pipe NP 3 / prestressed concrete pipe. (Laying Reinforced cement concrete pipe NP3 /prestressed concrete pipe for culverts including fixing collar with cement mortar 1:2 but excluding bedding below pipes, excavation, protection works, backfilling, concrete and masonry works in head walls and parapets .) 1000 mm dia
Back filling behind abutment, wing wall and return wall complete as per drawing and Technical specification 710.1.4 of I.R.C. 78 and 2200. (i) Granular material
Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material including dewatering etc. complete. Ordinary soil Upto 3 m depth
Sand Filling in Foundation Trenches as per Drawing & Technical Specifications.
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M15
Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. Using concrete mixer PCC Grade M20
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags).Height upto 5m Using concrete Mixer P.C.C. Grade M-20
Providing and laying Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications section 1500, 1700 and 2200 (Newly laid concrete shall be covered by gunny bags).Height upto 5m Using concrete Mixer R.C.C. Grade M-20
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in foundation complete as per drawing and technical specifications as per section 1600.
Supplying, fitting and placing HSD (High Strength Deformed Steel) bars reinforcement in sub-structure complete as per drawing and technical specifications section 1600 and 2200.
Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification sections 1500, 1600 and 1700 (Newly laid concrete shall be covered by gunny bags).RCC Grade M30 For Solid Slab Super Structure Using Concrete Mixer Height upto 5m
Supplying, fitting and placing HSD (High Strength Deformed Steel) bar reinforcement in super-structure complete as per drawing and technical specifications
Filler joint Providing & fixing 20 mm thick compressible fiber board (12 m long x 25 cm deep ) in expansion joint complete as per drawing & Technical Specification.
Providing and fixing in position tar paper bearing for slab as per approved drawings and specification.
Providing weep holes in Brick masonry/ Plain/ Reinforced concrete abutment, wing wall/return wall with 100 mm dia. AC pipe, extending through the full width of the structure with slope of 1 V: 20 H towards drawing face. Complete as per drawing and Technical specifications section 2706 and 2200.
Providing and laying of Filter media with granular materials/stone crushed aggregates satisfying the requirements laid down in clause 2504.2.2. of MORT&H specifications to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and provided over the entire surface behind abutment, wing wall and return wall to the full height compacted to a firm condition complete as per drawing and technical specifications 710.1.4 of I.R.C. 78 and 2200.
UOM Name
Percentage
Per mile
Siemens Per meter
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 1.09 MB
8710058785049349524_165800_6957221190378191642_126401__Guidelines_to_Bidders.pdf
NIT • 0.13 MB
6797296932284012618_190754_Form A.doc
NIT • 0.15 MB
1956761268777939111_190754_NIT.doc
NIT • 0.31 MB
5780581672134277397_190754_Notice.doc
NIT • 0.10 MB
8305614958161447251_190754_PQ.doc
NIT • 0.28 MB
2576393325508626318_190754_BOQ.xlsx
BOQ • 0.04 MB
Download all tender documents and submit your bid