Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹14.5 L+₹49,900 (3.55%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹14.6 L+₹50,627 (3.60%)Rejected-Finance NO 4 SRIRAMULU VILLA MULLAI STREET KANDAN NAGAR TIRUTTANI 631209 | TIRUTTANI | THIRUVALLUR | TAMIL NADU | 631209 | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹14.7 L+₹67,315 (4.79%)Rejected-Finance | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹16.5 L+₹2.4 L (17.2%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
17 Jan 2022, 6:00 pmClosed
GARRISON ENGINEER
Garrison Engineer (AF) Air Force Station Tambaram, Chennai - 600 046
REPAIR/ MAINT OF TWO / FOUR POLE STRUCTURE, REPLACEMENT OF MCCB / MAIN SWITCHES AND OTHER MISC E/M WORKS IN TECHNICAL AREA INSIDE MAIN CAMP AT AF STATION TAMBARAM
2021_MES_495658_1
GE(AF)/TAM/8514/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Airforce Station Tambaram
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
GE AF TAMBARAM
₹36,000
Yes
3 Feb 2022
17 Dec 2021
19 Jan 2022
18 Dec 2021
17 Jan 2022
4 Jan 2022
18 Dec 2021 - 24 Dec 2021
Amount
Excavation in trenches not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out in hard/dense soil for laying cable, foundation for pole etc complete all as specified and directed.
Returning filling in soil including providing cable cushioning with riddled earth obtained from excavation, leveling watering and well ramming in layers not exceeding 25cm thick over the cushion layer all as specified and directed.
Removing of surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point all as specified and directed.
M & L for brick protection to cable using old size sub class 'B' bricks, laid flat, dry butt jointed, laid lengthwise perpendicular to the axis of cable all as specified and directed.
Relaying of old serviceable bricks of any size removed from old cable trenches laid across trenches for cable protection all as specified and directed.
M&L for plain cement concrete 1:3:6, type C1, using 20 mm graded stone aggregate as in foundation/ coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair all as specified and directed
M&L for Straight through joints suitable for 3.5/4 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits complete for making joints all as specified and as directed for the following : - Make :- Raychems / Densons / M-Seal /Birla-3M / CCI / Siemen
3.50/4 core cable 25 to 50 Sq mm.
3.50/4 core cable 70-120 Sq mm
3.50/4 core cable 150-185 Sq mm
3.50/4 core cable 240-300 Sq mm
M&L for End termination indoor/out door heat shrinkable joint kits suitable for 3.5/4 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits complete for making joints all as specified and as directed for the following : - Make :- Raychems / Densons / M-Seal /Birla-3M / CCI / Siemen
3.50/4 core cable 25 to 50 Sq mm.
3.50/4 core cable 70-120 Sq mm
3.50/4 core cable 150-185 Sq mm
3.50/4 core cable 240-300 Sq mm
M&L for Separating pick and stacking stone aggregate spread in the installation yard of transformer/two/four pole structure aside for reuse cleaning surface free from vegetation, grass etc.., all as specified and directed.
Supply and spread 20/40mm graded stone aggregate as approved quality for installation yard all as specified and directed.
M&L for cutting, removing the vegetation growth and surface dressing all around the installation yard including 4/2 pole structure area to keep the installation area (external only) clean and tidy all as specified and directed. Note :- All the sub station yards shall be kept clean through out the contract period by repeatedly removing the grass/ however weeds as and when ordered by Engineer-in-charge depending on the growth of the grass, however this item shall be measured and paid only once during entire contract period.
M&L for cutting chases on concrete surfaces for concealed GI tubing/HDPE pipe, girth exceeding 10 cm but not exceeding 20 cm ,making good to facing and disturbed surface in cement morter 1:3 and finished as per existing all as specified and directed.
Taking out the existing LT UG cable of any description of following size to find out the fault and re-laying the serviceable LT UG cable 1100 Volts grade PVC insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including necessary lugs/thimble/ferules connection, testing and commissioning complete all as specified. Note: [a] Earth work, excavation sand cushioning, bricks for protection, GI pipe, LT UG Cable Joints etc shall be measured separately under relevant items of this schedule . [b] Defective portion of cable shall be removed, serviceable cable shall be re-laid and balance with new LT U/G cable .(C) New LT UG cable shall be measured and paid as Supply only LT UG cable under schedule /BOQ item No 26 of this schedule.
10 sqmm to 16 sqmm 2/4 core
25 sqmm to 35 sqmm 3.5 core / 4 core
50 sqmm to 120 sqmm 3.50 core
150 sqmm to 240 sqmm 3.50 core
Supply and laying in repairs LT UG cable 1100 Volts grade XLPE insulated PVC sheathed amoured, heavy duty, in trenches/walls/poles/passing through pipes with multistranded aluminium conductor including lugs/thimble/ferules connection, testing and commissioning complete all as specified and directed for the following sizes.
185 sqmm 3.50 core
240 sqmm 3.50 core
25 sqmm 3.5 core
50 sqmm 3.50 core
70 sqmm 3.50 core
95 sqmm 3.50 core
120 sqmm 3.50 core
150 sqmm 3.50 core
M&L for GI tubing 'Light' grade with all fittings for cable protection fixed on poles/walls/laid under roads crossing etc and made good the disturbed surfaces/area all as specified and directed for following sizes of pipes :-
For 40 mm Bore
For 50 mm Bore
For 80 mm bore
For 100 mm bore
Supply & fixing of Sheet metal enclosure suitable for 4 pole MCCB upto 125 A MCCBs,36 KA Size I Enclosure for DU100H/DU125H/ DU100D125D/DN0/DY125U with all connections all as specified and directed (Make-L&T Cat part no CM909960000 or eqivalent make from list of makes )
Supply & fixing of Sheet metal enclosure suitable for 4 pole MCCB upto 250 A MCCBs,36 KA Size II Enclosure for DU250C/DU250/ DN1with all connections all as specified and directed. (Make-L&T Cat part no CM91003OOOO or eqivalent make from list of makes )
M&L for MCCB 4 pole, 415 volts fixed overload & fixed short circuit setting including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. including taking out the existing unserviceable MCCB and making good the disturbed surface all as specified and directed for following capacity.
100 Amps with breaking capacity 16 KA
125 Amps with breaking capacity 25 KA
160 Amps with breaking capacity 25 KA
200 Amps with breaking capacity 36 KA
250 Amps with breaking capacity 36 KA
320 Amps with breaking capacity 36 KA
400 Amps with breaking capacity 36KA
Dismantling of existing totally unserviceable LT panel board by disconnecting incoming and outgoing cables, earth wire etc and Supply , install, test and commissioning of LT Panel board of size 1.8x1.6x0.8 mtr suitable for 3 phase 415 Volt of both side opening double door with push type metal lock, heavy duty wide hinges, separate common across cable aley,made out 3 mm CRCA Sheet with angle iron frame of size(50 x 50 x 6 mm) and MC channel of size (75mm x 40 mm) for panel base outdoor type,free standing cubical type totally enclosed weather dust and vermin proof with front and rear opening with locking arrangement of 440 Volts 3 phase 4 wire 50 Hz having aluminium bus bar of capacity 1000 Amps ( 50X5 mm cross section), with IP 54 as per IS 13947 protection, and half neutral with aluminium bus bar RYB duly insulated complete including internal wiring with copper conductor, provn of suitable cable glands including two coats of primer and one coat of spray painting including connecting all incoming and outgoing cable feeders with necessary lugs ferrules etc . including pcc foundation support , well finishing with cement mortar.Comprising of the following switch gear and accessories are as under complete all as specified and as directed.
M&L for painting the existing steel tubular LT poles, 9m long including cross arms, channels, angle iron support, bracings, clamps etc. with two coats of aluminum paint superior quality of approved make on surfaces exposed to view and making 30cm wide strips (Total 5 Nos) with white and black paint alternately on external surface above PCC benching including preparation of old painted surfaces by scraping etc complete all as specified & directed.
M&L for cutting, trimming and prunning of trees/tree branches of any girth upto 4m all around existing LT/HT over head lines including cleaning the disturbed area beneath the LT/HT overhead lines and removing the tree/ tree branches and debris from at site and depositing where directed at site. Note: (a) This item shall be measured and paid only once during entire contract period , however each span of LT over head line shall be clear from tree branch growth through out the contract period seperately. (b) Cutting trimming, prunning of tree / branches shall be carried out as and when ordered by Engineer-in-chrage depending on growth of tree (c) Approximate span between poles shall be 45m to 60m.
Taking down old serviceable conductors any description and re-stringing/ tightening of ACSR conductor (size- squirrel/ weasel/ ferret) / GI earth continuity conductor/ cradle up to the permissible sag limit between any span length and binding the with new binding wire of the same materiel to insulators all as specified and as directed. Note :Approximate span between poles shall be 45m to 60m.
M&L for pin type insulator, porcelain, vitreous, white, brown or green insulator of size 100 mm height, 65 mm dia for 1100 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron bolt including taking out the old unserviceable insulator and making good the all as specified and as directed.
M&L for removing old/burnt out jumper connection in binding with HT/LT lines from position including re-binding the same with new binding wire of size 3.25mm aluminium wire all as specified and directed.
Global Safety Engineering and Management Solutions
SREE VENKATESWARAS CONSTRUCTIONS
RADHIKAGANESH ENTERPRISES
S.M.THIYAGARAJAN AND CO
ragavbuilders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .