Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.4 LAccepted-AOC AZARA PO KAMRUP DIST GUWAHATI 781 015 ASSAM | KAMRUP METRO | ASSAM | 781015 | L1 | Accepted-AOC RATES ARE FOUND REASONABLE AND THE FIRM BEING L1 BIDDER | |
| 2 | L2₹7.4 L+₹90,279 (13.9%)Rejected-Finance THIS INFORMATION IS NOT AVAILABLE IN THE PROVIDED DOCUMENT | KAMRUP METRO | ASSAM | 781005 | L2 | Rejected-Finance BEING L2 BIDDER | |
| 3 | L3₹8.4 L+₹2.0 L (30.4%)Rejected-Finance | L3 | Rejected-Finance BEING L3 BIDDER |
Tender Value
₹8 L
EMD Value
₹16,000
Closing Date
14 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RANGIA
GE Rangia C/O 99 APO Rangia
REPAIR TO SEWAGE LINES, MANHOLES, SEPTIC TANKS AND OTHER ALLIED WORKS AT RANGIA MILITARY STATION UNDER GE RANGIA
2020_MES_373482_2
8400/E8
Open Tender
Civil Works
Item Rate
180 days
RANGIA
AS PER NIT
8 documents required · 8 mandatory
₹500
GE RANGIA
₹16,000
Yes
24 Nov 2020
30 Sept 2020
16 Oct 2020
30 Sept 2020
14 Oct 2020
1 Oct 2020
60 days
Amount
Taking down rainwaters pipes any size or pattern including all fittings heads,shoes,bends,etc including cleaning or refixing or removal to store ( measured overall as fixed along the centre line over fittings and accessories) complete all as specified and as directed by Engineer-in-charge.
Demolition of brick work built in cement mortar including all quions, arches pillars etc. complete all as specified and as directed by Engineer-in-charge.
Demolition of re-inforced cement concrete of any description and in any position for manhole cover slab complete all as specified and as directed by Engineer-in-charge.
Cleaning of sewage line of any diameter and of any description including manholes by manually or other means, to clear the sludge/blockage inside the sewage line and manholes and will be flushing with water to drain out sludge etc. inside the sewage line from manhole to ease the flow of sewage including removing the sludge and re- fixing the manhole cover complete all as specified and as directed by Engineer-in-charge.
Cleaning of manhole including removal of sludge of any size and depth upto 0.75 Mtr complete all as specified and as directed by Engineer-in-charge.
Cleaning of manhole including removal of sludge of any size and depth from 0.75 Mtr to 1.50 Mtr complete all as specified and as directed by Engineer-in-charge.
Excavating in trenches n exc 1.5m wide and n.exc 1.5m depth for sewage line and manholes, drain etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Excavating in trenches n exc 1.5m wide and exc 1.5m but n.exe 3.00m depth for sewage line and manholes, drain etc and getting out in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Returning, filling in,including spreading, levelling watering and well ramming in layer not exc 25 cm in soft/loose soil complete all as specified and as directed by Engineer-in-charge.
Removing excavated surplus soil at a distance n.exc 50m and depositing complete all as specified and as directed by Engineer-in-charge.
M & L Plain Cement Concrete 1:3:6 Type B2 using 40 mm graded stone aggregate in foundation filling and mass concrete complete all as specified and as directed by Engineer-in-charge.
M & L Plain cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in benching/cooping including necessary form work mould and finished exposed surfaces even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M & L Pre-cast RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in cover slab set in CM 1:4 complete all as specified and as directed by Engineer-in-charge.
M & L extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including form moulds, mitred/stopped ends etc complete all as specified and as directed by Engineer-in-charge.
M & L for brick work with sub class B bricks, straight or curved on plan exc 6 m mean radius built in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M & L for Brickwork with sub-class 'B' bricks in one brick thick honey comb walling, built in CM 1:6 complete all as specified and as directed by Engineer-in-charge.
M & L TMT bars 10 mm dia and over, cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clip to Fe-410 incl fabrication complete all as specified and as directed by Engineer-in-charge.
Demolition of plain cement concrete in ground floors and paving n exc. 15 cm thickness (below or above GL) complete all as specified and as directed by Engineer-in-charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing coat ), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed by Engineer-in-charge.
M & L 75 mm thick PCC (1:3:6) type C-2 using 40mm graded aggregate as in plinth protection/footpath even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.
M & L 75 mm thick PCC (1:3:6) type C-2 using 40mm graded aggregate as in Sub base complete all as specified and as directed by Engineer-in-charge.
M&L 15mm thick screed bed in CM 1:6 on brick or concrete surfaces for fixing of tiles as in floor complete all as specified and as directed by Engineer-in-charge.
M&L 10mm thick backing coat in CM 1:4 on brick or concrete surfaces for fixing of wall tiles as in dado/skirting complete all as specified and as directed by Engineer-in-charge.
S&F Non skid colour ceramic tiles (300x300)x6 to 7mm thick in floors/skirting etc set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed by Engineer-in-charge.
S&F for colour Glazed ceramic tiles (300x200)x 6x7mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and as directed by Engineer-in-charge.
M&L for rendering 15mm thick in cement mortar (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth without using extra cement at foul position complete all as specified and as directed by Engineer-in-charge.
M&L for 15mm thick rendering in cement mortar (1:3) mixed with water proofing compound on fair faces of brick work of concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge. (Note-WPC shall be measured and paid separately).
Supply only integral water proofing compound ISI marked complete all as specified and as directed by Engineer-in-charge.
S&F 110 mm bore PVC(SWR) pipes single socketed in any length with rubber ring joints laid in trenches or in fioors complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm bore PVC(SWR) pipes single socketed in any length with rubber ring joints fixed to fioors complete all as specified and as directed by Engineer-in-charge.
S&F of 150 mm internal diameter of double wall corrugated(DWC) high density polyethelene pipes(HDPE) and stiffness classes-8(SN-8) with ISI marked(with CML no) with and including all fitting & jointing material for sewage line and laid in trenches as specified in IS 16098-2013 part-2 complete all as specified and as directed by Engineer-in-charge.
S& F PVC (SWR) bend of any radius, 110 mm bore ,with access door complete all as specified and as directed by Engineer-in-charge.
S& F PVC (SWR) bend of any radius, 75 mm bore ,with access door complete all as specified and as directed by Engineer-in-charge.
S&F 75 mm bore PVC (SWR) junction single (Single'T'), equal or unequal, fixed to wall complete all as specified and as directed by Engineer-in-charge.
S&F 110 mm bore PVC (SWR) junction single (Single'T'), equal or unequal, fixed to wall complete all as specified and as directed by Engineer-in-charge.
M&L Cement concrete 1:3:6 type C2 (using 40mm graded stone aggregate) concrete in bed to drain pipe including packing under and haunching against the sides of pipes 150 mm internal dia after laid joined and tested complete all as specified and as directed by Engineer-in-charge.
Demolition of reinforcement cement concrete pipe of 300mm dia below GL complete all as specified and as directed by Engineer-in-charge.
M&L for reinforced concrete pipes class NP2 of 300 mm dia laid and jointed with collar complete all as specified and as directed by Engineer-in-charge.
S&F in repairs vitreous china squatting pan 'Orissa' pattern, size 580x440 mm,white with 'P' or 'S' trap size (Excluding flushing cistern and flush pipe) including integral foot rest complete and provision of cement concrete bedding complete all as specified and as directed by Engineer-in-charge.
Taking down existing EWC/IWC alongwith complete PCC and lime concrete from sunken floor and providing new EWC/IWC and water proofing treatment to sunken floor as per following stage :- (i) 15mm rhick plastering in CM (1:2) with WPC at all around and base of sunken floor with proper slope. (ii) Applying a coat of 85/25 gde hot bitumen @ 0.7kg/sqm over a coat of bituminous primer @ 0.5kg/sqm and then pasting of polythene film, 150 mocron, natural colour with cold cut back adhesive. (iii) Fixing of 25mm dia GI pipe (Med Gde) spout of length 45cm. (iv) Providing lime concrete and cement concrete to fillup the sunken floor (PCC 1:4:8) after testing of water tightness.
Cutting into existing manhole for connection new drain making good to pipe and rendering cutting out existing benching and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B1 smooth finish and reforming benching as required for 150mm dia.
Opening of blokage to nahni trap,WC, floor trap,exc including washing/cleaning upto Ist manhole complete all as specified and as directed by Engineer-in-charge.
Opening of blokage to gully trap,of WC outlet, including washing/cleaning upto Ist manhole complete all as specified and as directed by Engineer-in-charge.
Cleaning of septic tanks of any capacity with removing of sludges etc and carrying to a distance exc 100 meters but n.exc 250 meters and depositing in ditches including necessary excavation and earth work in soft/loose soil for making ditches and refilling the ditches after the sludge’s are deposited with spreading and leveling of excavated soils in the ditches over the sludge, removing surplus soils to a distance n.exc 50m and supply and sprinkling bleaching powder over the area of ditches with one meter around complete all as specified and as directed by Engineer-in-charge.
Cleaning of septic tanks of any capacity with removing of sludges etc and carrying outside MOD land and depositing in ditches including necessary excavation and earth work in soft/loose soil for making ditches and refilling the ditches after the sludge’s are deposited with spreading and leveling of excavated soils in the ditches over the sludge, removing surplus soils to a distance n.exc 50m and supply and sprinkling bleaching powder over the area of ditches with one meter around complete all as specified and as directed by Engineer-in-charge. Note: Cost included is deemed to include the cleaning of septic tanks, carrying of sewage/sludge and water outside MOD and necessary permissions if required shall be dealt through by the contractor.
Rough excavation in soft/loose soil and getting out for shallow pit n. exc 1.5 m deep and spraying adequate quantity of bleaching powder inside the bottom pits and its walls as well over the sludge for hygienic condition, and spreading levelling in layers the excavated earth on the shallow pits to cover the sludge in the pit, complete all as specified and as directed by Engineer-in-charge. Note: Bleaching powder shall be measured and paid separately.
Supply of bleaching powder confirming to IS code and ISI marked brand complete all as specified and as directed by Engineer-in-charge.
S&F Machine pressed precast concrete interlocking paver block gloosy finished of size confirming to IS 15658-2006 and 60 mm thick, M-35 Grade laid over sand cushioning layer of 40mm thick of any shape and design including taking down old unserviceable blockscomplete all as specified and as directed by Engineer-in-charge. NOTE - ( Sand cushioning layer will be measured and paid seperately )
M&L for for sand cushioning layer 40m thick over sub baqse for fixing of interlocking tiles spread levelled to reqd level complete all as specified and as directed by Engineer-in-charge.
M&L broken bricks for loose filling with aggregates of gauge 80 to 150mm in soakage pits, soakage wells etc including taking out old broken bricks complete all as specified and as directed by Engineer-in-charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ.
M/S Rajkamal Enterprise
MS Gautam Construction and CO
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .