Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.3 LAccepted-AOC BARZ PATRA KHORCHA | BARDHAMAN | WEST BENGAL | 713364 | ₹28.3 L | L1 | Accepted-AOC Lottery winner |
| 2 | L1₹28.3 LRejected-AOC AT DIMIRIMUNDA PO RAJKISHORENAGAR PS KISHORENAGAR DIST ANGUL PIN 759126 | ANUGUL | ODISHA | 759126 | ₹28.3 L | L1 | Rejected-AOC Lottery looser |
| 3 | L1₹28.3 LRejected-AOC AT DHAURAPALI PO RAJ KISHORENAGAR DIST ANGUL 759126 | RAJKISHORENAGAR | ANGUL | ODISHA | 759126 | ₹28.3 L | L1 | Rejected-AOC Lottery looser |
| 4 | L1₹28.3 LRejected-AOC | ₹28.3 L | L1 | Rejected-AOC Lottery looser |
| 5 | L1₹28.3 LRejected-AOC | ₹28.3 L | L1 | Rejected-AOC Lottery looser |
Tender Value
₹28.3 L
EMD Value
₹28,400
Closing Date
23 Feb 2026, 5:00 pmClosed
Superintending Engineer Angul R and B Division
O/O the Superintending Engineer Angul RB Division
Renovation of old conference hall and allied peripheral developmental works at Sub Collector office Athamallik (Civil, EI)
2026_EICCL_125653_5
SE (R and B) Angul-70/ 2025-26
Open Tender
Civil Works - Buildings
Percentage
90 days
ANGUL
Please refer Tender documents.
2 documents required · 2 mandatory
₹6,000
₹28,400
Yes
25 Jun 2026
7 Feb 2026
24 Feb 2026
7 Feb 2026
23 Feb 2026
7 Feb 2026
Part-A (Civil Work) Earth work in excavation by manual / mechanical means (Hydraulic excavator) in foundation trenches or drains, including dressing of sides and ramming of bottoms and dewatering wherever required, including all lifts, including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 5km including cost of all labours/ equipments , taxes, sundries and T&P etc all complete as per the direction of Engineer-in-charge. All kinds of soil Upto 1.5 Mtr Depth
Disposal of building rubbish / malba /rock/ similar unserviceable, dismantled or waste materials by mechanical means within 1km Lead away from the site, including loading, transporting, unloading to approved dumping ground or as approved /directed by Engineer-in-charge, including cost of equipments/ labour, conveyance, T&P and taxes etc. as per the direction of Engineer-in-charge.
Supplying, diluting and preparing chemical emulsion like CHLORPYRIPHOS or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as pre-constructional anti termite treatment and creating a chemical barrier under and around wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, surrounding the pipes and conduits etc. complete at the rate of 7.5 liters (or as directed by the manufacturer) per sqm on vertical and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center etc.complete as per IS:6313/1981(Part-II) and as per the direction of the Engineer -in-charge including all cost of materials, labour, taxes and T&P etc all complete.
Filling in foundation, trenches and plinth with river sand in layers not exceeding 20 cm in depth, well watered and compacted in layers with top surface dressed and leveled to proper gradient including cost of all materials, conveyance, all taxes and royalties, loading and unloading, including cost of all labour, all taxes, sundries ,T & P etc. complete as per directions of the Engineer -in-charge.
Providing and laying of Cement Concrete of grade 1: 4 :8 (1cement : 4 sand : 8 graded stone aggregate of size 25mm to 40 mm hard granite crusher broken metal ) ,mixing in concrete mixer ,lowering and compacting in proper thickness , watering & curing for the required period, including all cost of labour ,material, conveyance,royalties and taxes , sundries , T&P etc. complete as per the direction of Engineer-in-charge.
Providing and laying in position machine batched/ machine mixed concrete of M25 grade for reinforced cement concrete work including laying of concrete using 12 mm to 20 mm size crusher broken hard granite chips excluding the cost of centering, shuttering, and reinforcement but including admixture in recommended proportions to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer- In - Charge. including cost all materials, conveyance , royalties and taxes, loading and unloading, cost of all labour, sundries, T&P etc.complete. a)Footing & Pedestal
b)Plinth Beam
c)Roof Beam & column
Providing, fixing in position TMT/Fe-500 reinforcement bars for RCC work of required diameter of approved quality including straightening, cutting, bending, binding, welding and joining (if necessary) and tying the grills and placing in position as required for R.C.C. work and providing hoisting, lowering and laying including cost of materials, conveyance and taxes of steel and binding wires of 16 to 20 gauge and labour required for the work for bending, binding and tying the grills in all heights as per the specification & direction of Engineer -in-charge. Ground Floor
Providing and laying Brick masonry work in Superstructure using Fly-Ash bricks confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. Ground floor
Providing 12mm thick cement plaster in cement mortar (1:6) to the surface of brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. Ground floor
Providing 16mm thick cement plaster to the surface of brick masonry wall with cement mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves and beads to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc all complete as per direction of the Engineer -in-charge Ground Floor
Providing 6mm thick cement plaster in cement mortar of (1:4) to RCC surfaces such as ceilings of roof slabs, stairs, landings, chajja, shelves, columns, beams and lofts etc. including roughening/ chipping, scraping and cleaning and finishing the plastered surface smooth using wooden floats, bars, etc. only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawing including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. Ground floor
Providing average 25mm thick grading Concrete with (1:2:2) using 6mm hard granite chips mixing of water proofing cement compound of approved quality over top of Roof, Terrace, including cost of scaffolding, scraping and cleaning the roof surface, plastering and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries, T&P etc. All complete in all respect as per direction of the Engineer -in-charge. Terrace
Providing & installing two component acrylic modified cementitious waterproofing coating with masterseal 551/ Equivalent over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 kg/sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect as per direction of the Engineer -in-charge. Terrace
Supply & Installation of Wooden Sports fooring system "AIRFLEX SMASH@" that should be compliance with the Area elastic with total thickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and 10mm Power Rubber Pad. Product top finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps from Germany which is sweat and saliva resistance according to DIN 53160- 1/2) to have higher polish life, The wooden flooring should have Eco-friendly manufacturing process with 100% sustainable and manageable plantation resource with raw material. The product should have been produced through Kilned and dried technology to maintain suitable moisture content The top wood should necessarily be sourced from 100% sustainable resource and should have with prefinished including sanding & polishing Structure of system should be 10mm thick rubber pad, 45mm thick pine runner with the width of 70mm, followed by the 20mm top flooring Top wood plank sizes should be 20mm Thick 130mm Wide and 1830mm length. Runners to be placed at a distance of 305mm CIC. Entire system should follow norms with the EN 14904(06/2006) and technical parameters for the product should have friction of 95 according to EN 13036-4, Shock absorption of 45% according to EN 14808, Vertical deformation should be 1.8mm according to EN 14809 and Vertical ball rebound should be 99% according to EN 12235 Ground Floor
Providing and fixing Acustic Panel.
Providing and fixing Vitrified tile of specified size in floors on 20 mm thick bed of cement mortar 1:4 (1 cement : 4 sand) with neat cement slurry . finishing the joint with epoxy based water proof grout to match the shades of the tiles etc.including cost of all materials,labours,taxes & royalties, conveyance ,loading and unloading ,sundries ,T & P etc .complete as per the specification & direction of Engineer-in-charge. Size of tile 600x600 mm Polished Ground Floor
Providing and fixing ISI marked both side laminated flush door shutters confirming to IS 2202(Part 1) of 34mm thickness with approved colour paint over a coat of primer etc including ISI marked necessary hardware fittings such as, SS Concealed Hinges (6"), stopper, Door eye & magnet, SS Tower bolt-8", Mortise lock Handle, Cylinder coin & knob key & knob, SS lock body etc. including cost of all labours, materials, conveyance, hardware fixing, loading and unloading and royalties, sundries and T&P etc all complete as per direction of the Engineer -in-charge. Ground floor
Supply and fixing of uPVC Sliding glazed Window made out of hollow multi-chambered uPVC sections having isolated drainage system with the design 3 Track 3 Panel System. The 2 track outer frame of the window having over all size of 98 x 52 mm (with mosquito mesh) having internal wall thickness of 2.50 mm. The glass sashes / shutters shall be made out of Upvc sections with over all size of 42 x 70 mm with internal thickness of 2.50 mm. The mosquito mesh shutter having over all size of 25 x 52 mm with internal wall thickness of 2.50 mm. Reinforcement of galvonised mild steel with thick ness of 1.50 mm has to put through out the Frame, glass shutter and mesh shutter. Glass support beading make of upvc sections will be fixed with EPDM gaskit to keep glass tight and unmoved. Single point locking system (called touch lock) made out of casted zamac with white powder coated and locking hook will make of SS 304 grade material. Aluminum guide rail will be fixed on the Bottom part of frame on which the glass shutters will run. The roller will make of nylon an having capacity of 40 - 120 kg depends on glass weight. Finseal will be provided to protect the dust in between closing point & interlocking point of glass & mesh shutters. The Interlock of the uPVC window should be approved by the Engineer-in- charge before fixing. Glass thickness and colour can be changed as per requirement. Ground floor
Supplying, Fitting and Fixing M.S works of approved designs made out of M S Flat, hollwo section, i Section, Square bars/ Round bars etc. in railings, grills, gates etc of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. Ground floor
Providing and Painting two coats with synthetic enamel paint of approved make, quality and shade on new Steel work to give an even shade over an under coat of primer of approved brand and manufacturer including the cost of all materials, cost of all labour, conveyance, loading, unloading, scaffolding, staging, T&P, etc, all complete as per the direction of Engineer-in-charge. (Note- colour and shade shall be approved before procurement and use.) Ground floor
Providing and applying 2 coats plastic emulsion paint of approved quality and shade over a coat of wall primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved quality to surfaces (interior) including throughly brushing the surface free from foreign materials, sand papering smooth the intermediate coats, providing necessary putty & primer including of all materials, labour, conveyance, taxes, royalties, scaffolding, watering, curing, sundries, tools and plants etc as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Ground floor
Providing and applying two coats of Weather Coat Paint of approved make, quality and shade to the external surface of the building over a coat of primer after finishing wall surface of walls with Acrylic wall putty (water based) of approved make and finished smooth and even surface to receive painting of approved shade and quality after cleaning the plastered surface perfectly by watering and brushing including cost of material, putty, paint, brushes, all labour, taxes, loading, unloading, scaffolding, T&P etc. as required for the work as per the direction of Engineer-in-charge. (colour & shade to be approved before procurment & use) Ground floor
PLAIN GYPSUM CEILING :- Providing fitting and fixing of false ceiling with aluminium anodised T section No - 3215 with 2'-0" center to center , l section No -1705 upto 15 micron on 4 walls to be fixed by means of steel screw and pvc plug and alluminium grid 2'-0"x2'-0" with 12. 5 mm th gypsum board suspended from ceiling etc complete . The rate shall be exclusive of trap door which shall be paid for separately. including all cost of materials , labour, overheads T & P etc., excluding gst complete excluding gst . Ground Floor
Supply & Installation of Dune Beveled Tegular Mineral Fiber Ceiling /equivalent using Dune Beveled Tegular Mineral Fiber Ceiling Tiles of size 600x600x16mm, NRC-0.50 with Silhouette Grid 15x38mm wall angle 19x19mm and Armstrong Suspension system. Etc etc. including cost of all labours, materials, conveyance, fixing & fitting ,loading and unloading, scaffoldings, sundries and T&P etc all complete as per direction of the Engineer -in-charge. ( OFFICE) excluding gst . (Armstrong /Equivalent ) Ground Floor
WOODEN PANELING WITH LAMINATE :- Providing and fixing wooden panelling suitably fixed to the walls with 19 mm thick WPC, ply finished with 1 mm thick texture / suede laminate complete with necessary Hardwood, skirting , mouldings & teak wood beading on the edge etc. as per the detail design including the cost of all materials, labour, overheads and T & P etc. complete. The exposed frame work shall be finished with matt finsish enamel paints / polish with mellamine to match with the shade of the Laminates.excluding GST . Ground Floor
Supplying, Fitting and Fixing M.S works of approved designs made out of M S Flat, hollwo section, i Section, Square bars/ Round bars etc. in railings, grills, gates etc of approved specifications / dimensions with necessary welded clamps fixed in proper position & plumb including a single coat of priming of approved quality metallic primer, making required holes in Masonary Walls / R.C.C Structures (where necessary) and grouting the clamps with C.C(1:2:4) with 12mm size black hard crusher broken granite stone chips, making good to the damages of Masonary Walls / R.C.C Structures including cost, conveyance, loading, unloading,stacking, royalties and taxes of all materials , cost of all labours, staging, scaffolding, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. Ground Floor
Part-B (E.I Works) Sub-Head I (modular Wiring Items) Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal 6A modular type (anti bactorial & flame retradant type) switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) (anti bactorial & flame retradant type) Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. . All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.Group A
Group B
Group C
Looping Point
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN) /Panasonic (vision) .(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 2 years against manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & flame retradant type)) with suitable size modular box & cover(anti bactorial & flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 16A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius-NEXT GEN)/Panasonic (vision) (For equipement power)(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Supplying,fixing of 3x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+3 nos 6A switch & socket(modular type) ( (anti bactorial & flame retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge. Make-Schneider (Zencelo)/ legrand( ( Myrius-NEXT GEN)) /Panasonic (vision) (For equipement power). (Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 1.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor. In 20 mm dia non metallic heavy duty conduit (LDB to LSB/LIGHT CKT)(2X1.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit.(BDB to LSB/LIGHT CKT/5A PLUG/UPS POINT ) (2X2.5+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallic heavy duty conduit .(PDB to PSB/ POWER POINT/AC POINT) (2X4+1X1.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 2 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallic heavy duty conduit .(LFDB TO LBDB/UBDB) (2X6+1X2.5)
Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLS insulated, copper conductor, single core cable Make- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI in recessed HMS FRLS PVC conduit of mentioned size Make-AKG/BEC/Precision/Norpak/Anchor/Kinjal as required as per direction of Engg.-in-Charge. 4 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallic heavy duty conduit.(LFDB TO LBDB/Medical equipement) (4X6+2X2.5)
s/f of 1x1.5 sq mm for inverter wiring
Supplying, installation, testing & commissioning of 25 amp modular socket outlet on surface or in recess, on 1 Nos two module GI box with 25A Starte motor . complete as direction of Engineer-in-charge.Switch & socket: Legrand(Myirus)/schneider-Zenclo/Simens(Marq)
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor , A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 2 years against defects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
Sub-Head II (Light fitting Fixture & Fan) Supplying, installation, of exhaust fan of heavy duty 300 mm sweep 1400 rpm with louvers (Make- Havells/Crompton/Usha/Orient/Bajaj ) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 2 years.
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 4 years.. .(With fan Regulator)
Supplying and fixing of recess/surface mounted backlit 2 X 2, 33W SMD LED 2x2 luminaire suitable for Armstrong / CRG /TRAC / USG/Celotex modular ceiling system having luminous efficacy upto 120 lm/w (3300lm) with dimension of 595mm x 595mm and height of 48mm. The luminaire should be able to be mounted on POP/Gypsum ceiling with the help of additional frame. Luminaire shall be made up of white powder coated extruded Aluminium housing with C shaped opal diffuser. The lumianire should supplied with inbuilt heat sink to provide better thermal management to enhance LED life. Luminaire should comply to LG7 guidelines. LM 80-08 compliant LEDs from reputed makes such as Nichia/Cree/ Bridgelux/ Lumiled/ Osram/Seoul should be provided. LEDs used in the product shall comply with EN 62471 for Photo-biological safety and certificate for the same from manufacturer shall be provided. The luminaire should be IP20 rated. The LED shall be compliant with LM80-08 standard with L70 life of 50000 Hrs tested at maximum current (Complete LM 80 test report for LED should be submitted for 10000 hrs of testing). The LEDs used should be with CCT of 5700 K and CRI of Minimum 80. LED Driver shall be Integrated type, Isolated, Constant Current operated driver with range 150-270V AC. Driver Efficiency > 85% & 3 KV internal surge protection, Power factor greater than 0.95 and total harmonic distortion (THD) of less than 10% should be integral to the luminaire. Manufacturer shall have inhouse lab approved by NABL or ministry of science of govt of India. LM 79 and LM80 reports need to be submitted from a NABL/UL accredited lab to verify above parameters. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2years.
Supplying and fixing of Energy efficient surface /recess mounted square /round shape 18 W LED luminaire of dimension of consists of white powder coated , die-cast Alluminium housing with high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 18 watt and lumen output of 1800 lumens, , CRI not less than 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 3 KV , L70 B50: 50000 hrs and all other accessories suitable for operation on 220 V to 240 V supply as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj).The luminaire should be Replacement Warranty will be 2 years
Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge . (Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
Supply & fixing of 45 Wt. LED Street light fitting comprises of Pressure die cast Aluminium housing powder coated in silver grey and toughened glass, Surge Arrester 1 No & 100lum/wt, Protection IP66 with bulb,choke,cover,G.I bracket,clamp & nut bolt connecting wire all accessories etc. as required as per direction of Engg.-in-Charge.etc. as required as per direction of Engg.-in-Charge. (Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supply, of recess mounted round Warm White LED COB spot downlighter with aspecial frosted diffuser suitable for 6W LED fitting including 6 watt LED luminairs of approved make complete with all materials & labour..(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
Supply, Installation,Testing & commissioning of indoor Flexible Warm White LED strip Light of 15W/Spoolwith Driver for cove lighting including all other materials as required(Make: Panasonic/LT/Havells /Philips/Wipro /Crompton/Bajaj)The luminaire should be Replacement Warranty will be 2 years
BDBS,DB,AC DB,FLOOR PANELS,MCBS Supplying and fixing of following mentioned way, three pole/single pole and neutral, sheet steel,double door MCB distribution board, 415 volts/240 volts shall be as per IEC 61439-3,integrated door earthing system offering additional safety to the user,High quality polyurethane Gasket,the box and cover shall be fabricated to withstand IK09,the DB should be properly pre-treated with 7 tank process and duly powder coated, phosphatized with powder coated finish, on surface/recess, complete with terminal blocks,with suitable size FR PVC insulated copper conducter up to terminal blocks, tinned copper busbar, neutral busbar, earth bar, din bar. Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/ABB ITUS as per direction of Engg.-in-Charge. The Distribution boards should be Replacement Warranty will be 3 years. 4Way (4+12) Way TPN MCB DD DB Horizontal type suitable for flush mounting and surface mounting with 100A Copper Bus Bar for each phase,with neutral Bus bar,Earth Bar & Cable ties for cable management,prefitted masking sheet,IP43-IK09 with metal door (For LIGHT,POWER INDOOR, 3-PH,POWER LOAD) Warranty on DB is 3 years
Supply and fixing of 12 way DD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) Warranty on DB is 3 years
Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series,10KA breaking capacity, single poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200. the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 20 /32 amps rating, 240 volts, C series,10KA breaking capacity, Double poles MCB of Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections as per direction of Engg.-in-Charge. .Warranty on MCB is 3 years.
Supplying and fixing 40/63 Amps rating, C series,10KA breaking capacity,4P, 415 volts, MCB .Make-LEGRAND-DX3/ Siemens-Betaguard/ Schneider- Acti 9/ABB SB 200 in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .. The MCB should be Replacement Warranty will be 3 years..
CABLING AND END TERMINATION MAIN AREA Supplying of one number PVC insulated armoured and PVC sheathed XLPE property AL. conductor power cable of 1.1 KV grade Make- Finolex/Polycab/HAVELLS/RR KABLE/KEI/Gloster of following size cables as per direction of Engg.-in-Charge. 2core x 4 sq mm
LAYING OF CABLE Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kv grade size not exceeding 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
ELV SYSTEM (Lan System) Supply & Laying of Cat6 23Awg UTP Cable, through existing conduit, Make: Legrand/Systimax/Panduit
Supply & fixing of RJ-45Jack of Category 6 with Dual-port British-style Face plate 86x86 mm with Curveture and wall mount box Make: Legrand/Systimax/Panduit
Supply & fixing of Cat6 24 Port Loaded Patch Panel:Make: Legrand/Systimax/Panduit
Supply & Installation of Cat6 Factory crimpped moulded patch cord,1mtr, Make: Legrand/Systimax/Panduit
Supply & Installation of Cat6 Factory crimpped moulded patch cord, 2mtr. Make: Legrand/Systimax/Panduit
Supply and installation of 24 Port Layer2 Giga (10/100/1000BaseT) PoE Switch with 4 x 1Gig SFP Port , Switching Capacity 56 Gbps, Throughput 41.7 Mpps ,Management Port 1 x RJ 45 Console port ,PoE power budget 270 Watt, Switch should support IEEE 802.3af & IEEE 802.3at standard ,MAC Address 16K , Jumbo Frame 12K ,Temperature Working 0°C~50°C, storage -40°C~70°C, Power Supply AC: 100~240VAC.Digisol Model No. DG-GS1528HPE-P/Cisco/HP
Supply & Installation of 9U/500Wall Mount Rack with FAN, PDU, Cable manager and H/W Pkt. Make : Netrack/Valrack/Rittal/APW
Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak 20 MM
(IP-PBX System) Supplying desktop telephone sets with colour ID as reqd Make-Panasonic/Beetel
Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the surface/ recessed steel/ PVC conduit as required. 2 Pair
(IP-CCTV System) Supply, Installation, Testing & Commissioning of Full High Definition 5MP( 2880 x 1624) resolution vandal proof dome/bullet camera, 1/3" Progressive Scan CMOS Sensor, IR Cut mechanical Filter for True Day & Night vision, Support dual streams, Onvif supported, IP66 Weather proof outdoor enclosure, Inbuilt Smart IR LEDs with intensity control, IR 30 mtr, H.264 / H.265, Supports android and iOS APP for Smart phone and tablets, with Inbuilt audio, -10°C to + 50°C, CE, FCC, RoHS . Make-Honeywell series 20/Pelco/Axis
Supply and Laying of cat6 23Awg UTP cable through existing conduit, Make: Legrand/Systimax/Panduit
2.0 TR high wall 5 star inverter type split A.C machine (BTU/Hr-21000-24000) with copper condensor & evaporator having ambient temperature 52 degree celcius with comprehensive 1 year warranty,5 years warranty on PCB, 5 years warranty on compressor (Make:O-General/Diakin/Mitsubishi/Hitachi/Carrier)
REFRIGRANT PIPING Supply,installation of hard/soft copper refregrant piping of size 5/8 inch and 1/4 inch for suction and liquid line with 3 corex4 sqmm FRLS Copper control cable alongwith 25 mm weather proof closed cell nitrile insulation ,complete with fitting of bends and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C
FRAME WORK Supply,installation & fabrication of MS base frame for both indoor and outdoor unit and other nesessary material to complete the job. 1 TR to 3 TR high wall split A.C
DRAIN PIPING Supply,installation & fabrication of Insulated drain water piping from indoor to nearestdrain point separate to all and other nesessary material to complete the job. 25mm nom. Dia pipe
Supply and fixing of 5kVA Voltage stabilizer (Make-V-Guard/Microtek
SH-OUTSIDE ILLUMINATION. SITC of Interactive Panel Size 75Inches or higher,Aspect Ratio 16:09,Resolution3840x2160 (4K-UHD resolution), Contrast Ratio 1,200:1 or higher,Brightness 400cd/m2 or higher, Response Time 5 ms or better, Viewing Angles 178°:178° (Horizontal/Vertical), Backlight Life 50,000 Hours or more, Protection Glass Thickness Thoughened Glass with level 7MoHS or above,Special features non-glare panel. Touch Technology Infrared Touch, Touch Point20 points or higher, Input/ Output Interface or more HDMl-3.0 x3, USB 3.0 x4, USB 2.0 x1, USB Type C x1, Touch USB B x2, OPS Slot x1 (80-pin), LAN In & Out x1, SPDIFx1, HDMI Out x1, Audio Port -1, RS232 x1 ,Connectivity WIFI,and RJ45 wired , Speakers 2*18W built-in Speaker, Wall Mounting Inbuilt OS Android 13 ; 4 GB or above RAM DDR4; 32 GB or above ROM, Certifications BIS, , Operational Life of 50,000 hours, Certificate-BIS & RoHS certified and offered product should be under Make in India product, ISO 9001, ISO14001, ISO 27001, OHSAS 45001, E-Waste CPCB Warranty3 Yrs Support Approved Makes: Delta, Barco, Chirstie
SITC of wireless handheld microphone. Rely on a solid transmission with up to 10 compatible channels in a stable UHF band. Dimensions approx. 200 x 42 x 127 mm. Pickup pattern Cardioid. Sensitivity < 3 μV at 52 dB(A)rms S/N. Signal-to-noise ratio ≥ 103 dBA. ransducer type Dynamic. Connection Wireless. Makes: Sennheiser, Shure, Rode
SITC of Compact Full range Cabinet Loudspeaker, LF Driver 2” Aluminium ; Max Power handling 20W @ 8 Ohms ;Frequency range 100Hz – 20Khz or more; Sensitivity 83dB and Max SPL 93 dB; Coverage 140° x 160° (H X V or more). Makes: Audac, Extron, Yamaha
SITC of Dual Channel Energy Star Rated Class D Amplifier , 2 X 150W @ 4Ω, 2 X 80W @ 8Ω, 1 X 300W @ 8Ω Bridge or better, Protection Circuit : DC, Overheating, Overload, Signal limiting, XLR Line Inputs , 2-Pin Terminal Outputs , 1U 19" Rackmountable. Makes: Audac, Extron, Yamaha
SITC of 22 awg 2C Mic Line Instrument Cbale through existing PVC Conduit. Makes: Belden,Finolex, Krystals
SITC of XLR Connectros for Microphones.
SITC of 2 core 1.5 sqmm speaker cable. Make: Finolex, Havells, Belden
SITC of 6U/500D wall mount rack with FAN, PDU and h/w screw pkt. Make: Valrack, Netrack, Legrand
SITC of 3KAV Online UPS with inbuild battary. Make: Delta, APC, Vertive
Supplying and fixing of following sizes of medium class PVC FRLS conduit ISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .Make-AKG/BEC/Precision/Norpak 20 MM
stage.html
html • 0.08 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_579749.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.73 MB
8OldConferenceSubCollectorAthamallik.pdf
Tender Documents • 1.47 MB
BOQ_579749.xls
BOQ • 1.45 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .