Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC C O SECTOR 02 HOUSING COLONY CHANNI HIMMAT JAMMU J K PIN 180015 | JAMMU | JAMMU AND KASHMIR | 180015 | L1 | Accepted-AOC Being the lowest and reasonable bidder | |
| 2 | L2₹10.3 L+₹51,140 (5.23%)Rejected-AOC | L2 | Rejected-AOC Being the other than lowest bidder | |
| 3 | L3₹11.3 L+₹1.5 L (15.7%)Rejected-AOC | L3 | Rejected-AOC Being the other than lowest bidder | |
| 4 | L4₹11.8 L+₹2.0 L (20.7%)Rejected-AOC | L4 | Rejected-AOC Being the other than lowest bidder | |
| 5 | L5₹12.6 L+₹2.8 L (28.3%)Rejected-AOC 1 181 KAMATCHI AMMAN KOVIL STREET KANNAN COLONY CHINTHAMANI MADURAI 625009 | MADURAI | MADURAI | TAMIL NADU | 625009 | L5 | Rejected-AOC Being the other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
14 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
HQ CWE Nagrota
HQ CWE Nagrota Co 56 APO
REPAIR AND MAINTENANCE OF STABLIZER, TRANSFORMER WITH CONNECTED SERVICES AT 213 TRANSIT CAMP UNDER GE NAGROTA
2020_MES_404018_1
CWE/NGT-44/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Transit camp Nagrota
As per NIT and tender documents
9 documents required · 9 mandatory
₹500
Yes
GE NAGROTA
₹30,000
Yes
18 Feb 2021
16 Dec 2020
16 Jan 2021
16 Dec 2020
14 Jan 2021
31 Dec 2020
16 Dec 2020 - 23 Dec 2020
75 days
Amount
Taking down transformer mounted on two/four pole structure or on plateform / indoor floor mounted carefully from their position after removing electrical connection, earthing leads etc, for executing necessary comprehensive preventive maintenance as well as repairs necessiated, including to and fro transporting to MES store yard/ contractor workshop and refixing after execution of maintenance/repair to their original position or to other location as directed of capacity 40 KVA to 250 KVA.
Labour , tools & plants only for opening the top cover of transformer out/in door type, step down 11 KV/0.415 KV of capacity 40 KVA to 250 KVA, lifting of core and winding, draining out transformer oil into container and keep aside for treatment and reuse, carry out strip inspection of core and windings for comprehensive routine, preventive maintenance and any other necessary repairs required to be executed. Refitting the core & windings after carrying out necessary routine maintenance / preventive maintenance or repairs so ordered making all electrical connections, providing sundry items i.e bolts, nuts & washers, reassembling the transformer complete, including testing and commissioning to the entire satisfaction of the Engineer-in-Charge, complete all as specified and as directed.
Cork sheet 6 mm thick gasket packing to transformers top cover of various capacity upto 160 KVA outdoor/ indoor.
Filtration, dehydration of transformer oil as drained out from transformer vide Sch 'A' Srl item No. 2 here-in-above to make the oil fit for reuse by improving its di-electric strength not less than 40 KV. Dielectric strength below of oil 40 KV shall be replaced with new oil (new oil for toping / or for replacement shall be measured and paid separately under appropriate item of Sch 'A') here-in-after.
Supply, treating (dehydrating), filling new transformer oil in transformers for topping up levels or for replacement of unfit oil. New oil shall have dielectric strength not less than 60 KV and shall be conforming to IS 335.
Taking out old breathers from transformer, supplying and fixing new breather dully filled with activated agent i.e silica gel for transformer of cap 40 KVA to 250 KVA
Dismantling Core, taking out damaged coils (HV Coils) from its position replacement, including supplying and fixing new winding coils with super enamelled copper winding wires of required gauge, number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge
Taking out damaged coils (LV Coils) from its position replacement, including supplying and fixing new winding coils with cotton braided copper wire or strip of appropriate size (thickness & width), number of turnings & weight to suit with the existing coils with allied insulation materials, packing with spacers etc, complete all as specified and as directed by the Engr-in-Charge.
Taking out HV procelain bushes from transformers for replacement being damaged, including supply and fixing new HV procelain, viterous white, brown or green of voltage grade 11000 V bushes to suit the size of transformers of different makes transformer of cap 40 KVA upto 250 KVA indoor.
Taking out LV procelain bushes from transformers for replacement being damagd, including supply and fixing new LV procelain, viterous white, brown or green of voltage grade 1100V bushes to suit the size of transformers of different makes transformer of cap 40KVA upto 250 KVA indoor/out door
Taking out worn out HV metallic alloy(brass/gun metal) bush rods, including supply and fixing new HV metallic alloy (gun metal/brass)bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of capacity 50 KVA to 250 KVA
Taking out worn out LV metallic alloy (brass/gun metal) bush rods, including supply & fixing new LV metallic alloy (gun metal/brass) bus rods of suitable length and dia with necessary nuts, washers and bushing packing to prevent oil leaking from the bushes including making necessary connections for transformer of cap 50 KVA to 250 KVA
Supply, fixing, commissioning & testing of dial type temp gauge 100mm dia having dial range 0-100 ºC complete with thermostat built in switch.
M & L complete for taking out unserviceable tap changing gear for replacement, including supply & fixing, making connections, testing & commissioning new tap changing gears in transformers of any description / rating and make complete all as specified and as directed.
M & L complete for denting out damaged external cooling tube of transformer & bring them to their original shape, of any type and description against of cap 40 KVA to 250 KVA.
M & L for welding to iron surface steel sheet in cooling tube/ body of transformer of any description to prevent leakages of oil , welding in repairs exceeding 2.5 cm but n.exc 5 cm in length, thickness of metal to be welded n.exc 6mm.
Painting to transformer old painted surface of steel after cleaning, scraping and preparing and filling cavities and providing one coat of synthetic enameled grey paint with spray gun process to transformer of capacity 40 to 250 KVA indoor/outdoor type
10 mm thick Synthetic insutated mat suitable for 11000 Volt grade (ISI Marked) of size 2mx1mx10mm complete all as specified and directed.
Supply & fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 6 Sqmm complete all as specified and directed.
Supply & fix Service cable /wire 1100 V flat twin core aluminium stranded conductor of size 10 Sqmm complete all as specified and directed.
S & F danger notice plate of size 25cmx20cm & 1.6mm thick, mild steel sheet, viteous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamp, bolts and nuts of approved size for HT all as specified and directed.
M&L Anti climbing devices ,Spikes type type fabricated out of M.S bars (round,square and flat) including nuts,bolts, washers and welding in two halves made to shape to suit the cross section of the pole.
Supply and fixing in replacement LT panels shutters made of MS sheet 16 SWG including fabrication to required shape and size by cutting / bending / welding including butt hinges and locking arrangment handle for doors as directed with two coats of synthetic enamel paint on both sides over a coat of red oxide primer complete all as directed and as directed by Engr-in-Charge at various sites.
Supply & fixing in replacement Aluminium thimbles for LT panels in cable and connecting upto with GI nut bolts and washers suitable for 25 Sqmm to 95 Sqmm cable size.
All as per Srl item No. 25 above but for 120 Sqmm to 185 Sqmm cable size.
Supply & Fixing in replacement MCCB 4 pole 63 amps 50Hz 415 volts with rupturing capacity 16 KA
Supply & Fixing in replacement MCCB 4 pole 125 amps 50Hz 415 volts adjustable type with rupturing capacity 16 KA
Supply & Fixing in replacement MCCB 4 pole 160 amps 50Hz 415 volts adjustable type with rupturing capacity 25KA
Supply & Fixing in replacement MCCB 4 pole 200 amps 50Hz 415 volts adjustable type with rupturing capacity 25KA
Supply & Fixing in replacement MCCB 4 pole 250 amps 50Hz 415 volts adjustable type with rupturing capacity 36KA
Supply & Fixing in replacement MCCB 4 pole 400 amps 50Hz 415 volts adjustable type with rupturing capacity 36KA
S&F Change over switch modular construction on load 415 volts TPN in sheet metal enclosure 4 pole of capacity 200 amps
S&F Change over switch modular construction on load 415 volts TPN in sheet metal enclosure 4 pole of capacity 160 amps
S&F Change over switch modular construction on load 415 volts TPN in sheet metal enclosure 4 pole of capacity 100 amps.
Supply and fixing in replacement indicator lamp set of three (RYB) complete.
M & L for laying, connecting and testing of 1100 volts grade LT XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured, heavy duty eletric power cable with aluminium conductor of size and type complete all as specified and directed including dismantling and taking down existing old LT cable of any size and type from pole/duct/trench/floor/wall/pipe etc with cable end boxes, glands, bricks etc with necessary disconnection work and keep in safe custody for the following size of cables:- Note:- (i) Excavation and earth work, sand cushioning, bricks & cable protection pipe will be measured & paid under appropriate items of Schedule 'A'
Cable of size 3.5 core 70 Sqmm
Cable of size 3.5 core 95 Sqmm
Cable of size 3.5 core 120 Sqmm
Material and labour for 80 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.
Material and labour for 50 mm dia light grade GI tubing with all fittings for cable protection laid in trenches, fixed on wall/pole with necessary fixing arrangements including dismantling the old pipe.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type of soil for errection of LT poles, laying of LT UG cables and provision of stay assembly complete
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm thick in any type soil complete all as specified.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point and entire satisfaction of Engnr-in-Charge complete all as specified and directed
Sand dry clean as cushioning to underground electric cable provided with a layer of 80mm deep before laying and 150mm over cable laid in trenches complete all as speficied. Note;- Punned thickness of the sand shall be measured.
Brick over cable laid in trenches as protection to cables with width equal to the length of bricks with well burnt sub class 'B' bricks (old size) complete all as specified.
Material and labour for earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25M deep below natural ground level ) with top edge of plate not less than 1.5M below normal ground level, surrounded from all sides alternate packed layer of charcoal dust and common salt and electrode connected with galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 of SSR part I including necessary earth work in any type of strata, foundation of pit and wall using PCC 1:3:6 type C1 using 20mm graded crushed stone aggregate 40 mm thick pit cover slab using RCC 1:2:4 type B0 using 12.50 mm graded crushed stone aggregate with 6 mm dia MS bar @ 100 mm C/C both ways GI medium grade 20 mm dia pipe for watering including funnel with wire mesh and 15 mm bore GI light grade pipe for earth lead wire protection up tp 7.5 mtr complete all as directed including testing complete on completion.
All as per Srl item No. 47 above but using 32x6 mm GI earth strip as a earth lead & 40 mm dia light grade GI protection pipe complete all as specified & directed Note for item No. 47 & 48 (i) GI wire/strip or protection pipe 15mm/40mm dia upto 7.5 RM is included in the quoted rate. (ii) The quantity above the 7.5 RM shall be measured & paid separately
M&L for earth continuity conductor or main earthing lead 4 mm dia GI or steel wire fixed to wall on batten or recessed or buried in ground or drawn in conduit/pipe all as required at site.
Supply & fixing for GI strip 32x6mm on wall/batten or recessed or buried in ground all as directed by Engineer-in-Charge.
Material & Labour for stay assembly comprising of stay bow (4000 x 14mm), stay rod 215 cm long and 20 mm dia with nuts, stay plate 300 x 300 x 6 mm thick and 2 nos of thimble complete as shown in electric plate no 1 of SSR part-1 connected to loop type insulator, including dismantling old unserviceable stay assembly complete including loop insulator wire etc from LT poles. NOTE :- Earth work, excavation, concrete and loop type insulator shall be measured and paid separetely under relevent items of Sch 'A'.
Supply and fix LT loop type insulators, vitreous, porcelain brown, white or green insulators for working pressure of 1100 volts grade of large size with over all dimensions 90 x 140 mm clearance of hole 25.50 mm including dismantling of existing LT loop type insulator from LT poles of any height place and position.
S&F Galvanised stay wire stranded of size 7/4 mm including necessary binding, strengthening complete all as directed
Material and labour for cement concrete 1:4:8 type D2 using 40mm graded crushed trap stone aggregate for foundation of poles/stays.
Material and labour for PCC (1:2:4) type B-2, using 40 mm graded crushed stone aggregate for making good the road cutting all as directed by Engr in Charge.
M&L for spreading coarse aggregate of 20 mm size upto 10 mm above the ground surface below the HT 2 pole, 4 pole structure including leveling & clearing ground surface by cutting shrubs, vegetation, grass, bushes, weeds & trees upto 30 Cm girth, sweeping & laying the same to distance not exceeding 50 M away from the 2 pole & 4 pole structure, all as specified & directed by Engr-in-Charge. Note :- Cutting & other neccessary material shall be provided by the contractor on his own arrangement
Supply and fix and draw ACSR Weasel/Squirrel conductor of size 06 strands of aluminium of 2.59/2.11 mm dia and 1 strand of steel of 2.59/2.11 mm dia on LT poles, bringing the sag within limit fixing on Insulator/Cross arms by means of necessary binding with 16 SWG aluminium binding wire and providing alkathine pipe of approved quality for jumpers, reconnecting the service connections after removing the carbon material including taking down ACSR conductor of any size & type from LT poles at any height position and place complete all as specified and directed by Engr-in-Charge.
Material and labour for switch Air break gang operated Triple pole, mechanically operated mounted on insulator & steel frame with operating mechanisum worked from ground level for current rating upto 200 Amps 11000 Volts grade all with male & female contacts, post insulator 15 Nos, operating rod, handle etc and renewal of jumpers with heavy duty alkathine pipe cable connections including dismantling of old unserviceable switches vertical/horizontal mounted, including insulator & operating mechanisum for repair/replacement of broken/worn out components and insulators etc complete.
Material and labour for drop out fuse assembly expulsion type single pole for 11 KV, 100 amps capacity complete consisting of galvanised steel base plate fuse carrying brackets channels with post insulator, fuse carrier fiber glass tube with fuse element complete including dismantling the old unserviceable one.
Material and labour for lightning arrester expulsion type high tension complete with all fittings transmission class discharge capacity 65 kilo amps suitable for 11 KV including necessary connections with Over head lines & earthing fixed on 2/4 pole structure, including dismantling the old unserviceable one.
Note:- Schedule of credit Rs. 64,998.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
ASHOKA ENGINEERS AND BUILDERS
M/S MANJIT SINGH AND SONS
proach associates
R K BUILDERS
SHSS ASSOCIATES
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .