Loading…
Loading…
Tender Value
₹4.9 L
EMD Value
₹9,802
Closing Date
29 Sept 2026, 4:00 pm2d left
Ex. Engineer RnB Electric Hospital Division Kmr
Office of the Executive Engineer RnB Electric Hospital Division Rajbagh Srinagar
Electrical works of SITC of Refrigerators and Deep Freezers at various areas of SKIMS Soura
2026_PWDJK_324437_1
eNIT No. HDE 46 of 2026_27 dated 11_09_2026
Open Tender
Electrical Works
Percentage
45 days
SKIMS Soura
Please refer Tender documents.
2 documents required · 2 mandatory
₹200
Ex. Engineer RnB Electric Hospital Division Kmr
₹9,802
Ex. Engineer RnB Electric Hospital Div Srinagar
29 Sept 2026
12 Sept 2026
30 Sept 2026
12 Sept 2026
29 Sept 2026
12 Sept 2026
16 Sept 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. | - | - | - | - |
| 2 | 4 Module (125mmX75mm) | 6 | Each | 401 | ₹2,406 |
| 3 | 6 Module (200mmX75mm) | 4 | Each | 462 | ₹1,848 |
| 4 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. | 50 | Each | 47 | ₹2,350 |
| 5 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surfacel recessed medium class PVC conduit as required.
FRLSH, Anti-fungal/Anti-Bacterial | - | - | - | - |
| 6 | 2 x 2.5 sq. mm +1 x 2.5 sq. mm earth wire | 250 | Metres | 414 | ₹1,03,500 |
| 7 | 2 x4 sq. mm + 1 x4 sq. mm earth wire | 250 | Metres | 476 | ₹1,19,000 |
| 8 | 2 x 6 sq. mm + 1 x 6 sq. mm earth wire | 100 | Metres | 652 | ₹65,200 |
| 9 | 4 x 16 sq. mm + 2x 6 sq. mm earth wire | 55 | Metres | 1,760 | ₹96,800 |
| 10 | Supplying and drawing following sizes of FRLSH/HFFR PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.
Anti-fungal/Anti-Bacterial | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.39 MB
BOQ_1094383.xls
BOQ • 0.30 MB
ExtHDE46.pdf
PDF • 0.73 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .