Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.9 LAccepted-AOC | 1 | Accepted-AOC LOWEST | |
| 2 | 2₹9.5 L+₹1.5 L (19.1%)Rejected-Finance 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | 2 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
Refer Docs
EMD Value
₹19,380
Closing Date
24 Dec 2020, 6:00 pmClosed
AGE (I) AF AMRITSAR
Asst Garrison Engineer (I) AF Amritsar
PROVN OF HARD STANDING AND SHED ALONGWITH ASSOCIATED WORKS FOR SOLID WASTE MANAGEMENT AT AIR FORCE STATION AMRITSAR
2020_MES_398995_1
AGE (I) AF/ASR/T-04/2020-2021
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) AF AMRITSAR
Class E Categry a(i) and b(I)
9 documents required · 9 mandatory
₹500
Yes
AGE (I) AF AMRITSAR
₹19,380
Yes
9 Jan 2021
27 Nov 2020
28 Dec 2020
28 Nov 2020
24 Dec 2020
10 Dec 2020
3 Dec 2020 - 9 Dec 2020
Amount
Surface dressing n exc 15 cm deep (Avg), as in soft loose soil, and removal of rubbish upto a distance of 50m, complete all specified and directed.
M&L, Excavation over area not exceeding 1.5m in deep and getting out in soft/loose soil, complete all as specified and directed.
M&L, removing excavated material n.exc 15km and depositing where directed completed all as specified and directed.
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Material and labour, 100mm thick Cement concrete (1:4:8) type D-2, using 40mm graded broken stone aggregate, finished fair and even as in sub base of floors, complete all as specified and directed.
Material and Labour, Cement concrete (1:4:8) type D-2, using 40mm graded broken stone aggregate as in foundations filling and mass concrete, complete all as specified and directed. Note : Form work if any required shall be measured and paid separately.
Material and labour, hardcore of broken stone or boulders of gauge not exceeding 63mm, deposited, spread and leveled in layers not exceeding 15cm thick, watered and rammed to a true surface, complete all as specified and directed.
Material and labour, Plain cement concrete (1:2:4) type B-1, using 20mm graded crushed stone aggregate, as in floor finishes, 40mm thick, surface finished even and smooth without using extra cement, complete all as specified and directed.
Material and labour, 75mm thick Cement concrete (1:4:8) type D-2, using 40mm graded broken stone aggregate, finished fair and even as in sub base of floors, complete all as specified and directed.
Material and Labour, 25mm thick Sand filling under floors including watering and consolidation, complete all specified and directed.
Material and Labour, Machine pressed precast concrete interlocking paver block of 60mm thickness, M-35 Grade, with grey cement and pigment, any shape and size, confirming to IS 15658-2006, over and including 25mm thick clean river sand and joints filled with sand, complete all specified and directed.
Material and labour, First quality, glazed ceramic coloured tiles, 6-7mm thick, of size 350mm x 250mm or 450mm x 350mm as in skirting, dados, risers to steps, etc., set and jointed in neat cement slurry @ 3Kg/Sqm, over and including 10mm thick rendering/backing coat in cement mortar (1:3), including pointing in white cement mixed with pigment or coloured cement to match the shade of tiles, complete all as specified and directed.
Material and labour, Vitrified Ceramic light coloured tiles 10 mm thick (square/ rectangular) polished, area of each tile not exceeding 0.36 sqm, laid in floors etc with and including 15mm thick screed bed/bedding layer in CM (1:4). set and jointed in neat cement slurry @ 3Kg/Sqm, and pointed in coloured cement or white cement mixed with pigment to match the tiles, complete all as specified and directed.
Material and Labour, machine cut Kota stone slab 20-25 mm thick, as in floors, treads of steps, laid over and including screed bed/bedding layer 15mm thick in CM (1:4), set in neat cement slurry @ 3kg/sqm, and pointed with grey cement slurry mixed with pigment to match the shade of the slab, including curing, rubbing and polishing, complete all as specified and directed.
Material and Labour, machine cut Kota stone slab 20-25 mm thick, as in skirting, risers to steps and similar vertical surfaces, laid on and including backing coat 15mm thick in CM (1:4), set in neat cement slurry @ 3kg/sqm, and pointed with grey cement slurry mixed with pigment to match the shade of the slab, including curing, rubbing and polishing, complete all as specified and directed.
Material and labour, plain cement concrete (1:3:6) type C-1 using 20mm graded crushed stone aggregate as in base of floor, 75mm thick complete all as specified and directed.
Material and Labour, Precast Chequered cement concrete tiles 30 cm x 30 cm x 22 to 25 mm thick, with grey cement and pigment (coloured), epoxy coated, set using neat cement slurry @ 3kg/sqm and jointed in neat cement slurry, and pointed in coloured cement or white cement mixed with pigment to match the surface, laid over and including 15mm thick screed bed or bedding layer in CM (1:4), complete all as specified and directed.
Material and labour, brick work with sub class 'B' old size bricks, straight or curved on plan exceeding 6m mean radius, built in CM (1:6), complete all as specified and directed.
Material and labour, rendering plaster 15mm thick in cement mortar (1:4) on surfaces of walls other than fair face of brick work, finished even & smooth without using extra cement, complete all as specified and directed.
Material and labour, rendering 15mm thick in cement mortar (1:6), on brick/concrete surfaces of walls, finished even and smooth without using extra cement, complete all as specified and directed.
Material and labour, preparation of newly plastered surfaces of walls, stopping of surfaces, leveling/edging the disturbed places using wall care putty and applying two coats of 1st quality oil bound distemper (oil emulsion) over and including a coat of 1.0mm thick white cement based wall care putty(JK/Birla) complete all as specified and directed.
Material & labour, preparation of new (plastered) surfaces of walls including brooming down, and steel wire brushing/scrapping down where required; to remove efflorescent salts spots etc.; washing, rubbing down using sand paper and applying 1mm thick white cement based wall care putty (JK/Birla) including stopping of disturbed surfaces, and applying two coats of exterior acrylic emulsion (1st quality paint), over and including a coat of primer, complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5cum, getting out in soft/loose soil, and removing surplus soil to a distance n exc 50m and making good bottom surface by watering and well ramming, complete all as specified and directed. Note : PCC as required to embed the posts shall be filled in the holes and to be measured separately.
Material and labour, Plain Cement Concrete (1:3:6) type C-1, using 20mm graded crushed stone aggregate as in bed blocks for fixing holdfasts, bed plates, PCC benching / gola to junction of wall and roof / chhajja, filling inside pressed steel frame etc., including use and waste necessary form work, complete all as specified and directed.
M&L for providing precaste cement concrete louvres and jallies, 25mm thick (mea-sured solid) including mouldings but excluding frame type C0 1:3:6 (12mm graded stone aggregate) set in CM 1:4 complete all as specified and directed.
Supply and fix for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed bolt ends, each screwed end to be fitted with washers and one hexagonal or squares nut n.exc 30CM long and dia of shank 12 to 20MM complete all as specified and directed by Engr-in-Charge.
Material and labour, Rolled sections Fe 410-W (Gde-E-250) quality-A as in roof trusses, main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates, complete all as specified and directed.
Supply and fix for mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed bolt ends, each screwed end to be fitted with washers and one hexagonal or squares nut exc 5CM but n.exc 10CM long and dia of shank 16 to 20MM complete all as specified and directed by Engr-in-Charge.
Supply and Fixing, Rolled mild steel Fe 410-W (Gde-E-250) quality-A, as in Plates (plain or chequered), channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment, complete all as specified and directed.
Supply and Fixing, Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick, of any colour, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
Supply and Fixing, Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick, of any colour, having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and directed.
M&L for 40mm thick Damp proof course in cement concrete 1:2:4, type B0 to horizontal or vertical surfaces including necessary form work all as specified and directed. Note : Water Proofing compound to be measured and paid for separately)
Material and Labour, PCC (1:2:4) type B-1, using 20mm graded crushed stone aggregate, as in coping kneelers, apex stones, bed plates, kerbs etc including necessary form work, complete all as specified and directed.
Integral water proofing compound.
Material and labour, point wiring with single core multi stranded copper conductor 1.5Sqmm (nominal area) PVC insulated unsheathed FRLS colour code cable of 1100volts grade drawn through and including non metalic rigid PVC conduit medium duty of suitable size with all standard fittings such as Tee junction, bends etc, concealed in wall/fixed on ceiling including M.S. sunken boxes of suitable size made of 1.6mm thick sheet duly painted with anticorrosive paint, for housing switches, fan regulators etc, PVC cover sheet 3mm thick (Make : Hylam, Plaza, Havells, Kalinga) including 1.5Sqmm (nominal area) multi stranded copper conductor PVC insulated unsheathed FRLS colour code cable of 1100volts grade for earth continuity, as for one light/exhaust fan/bell point or fan point (through regulator), controlled by one switch, complete all as specified and directed.Note : (i) Rate quoted shall be deemed to include cutting chases for concealing conduit and making good in cement mortar (1:4) or PCC (1:2:4) as required.(ii). Switches and fan regulator etc., shall be measured and paid separately.
(a) For one light/fan/bell point controlled by one 6 Amp one way switch
(b) All as per item No. 2 herein before but wiring for one 3 pin 6 Ampere socket outlet point on the same borad, controlled by other switch complete all as specified and directed.
(c) All as per item No. 2 herein before but wiring for one 3 pin socket outlet 6 amps independent board.
All as per item No. 2 herein before but with 2.5 Sqmm size cable multy standard FRL copper solid wire unsheathed for one 3 pin soket outlet 16 Amp on independent board including continous copper solid conductor connecting to comman earth dully completed all as specified and directed by Engr-in-Charge . Note : Sunken boxes, frame, plate is included in the quoted rate.
Supply and fixing LUMENO LED tube light fitting 1 x 22 watts Havells Cat No. LHE X BTP71N1SO22 or Wipro Cat Part No. D532265 with PVC insulated flexible copper cable from ceiling rose to tube light fitting complete all as specified and directed. Make : Havells
S & F light fitting 1 x 10 watt bulk head luminaires including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230 Volts, 50HZ complete all as specified and as directed
S&F of lamp holder PVC / polycorbonate type insulated body with back plate suitable for batten fitting / angle fitting complete all as specified and directed.
S & F of ceiling rose, surface bakelite, 65 X 50 mm, 3 terminals complete all as specified and directed.
S & F of switch piano flush type single pole one-way 6 Ampere complete all as specified and directed.
S & F of switch piano flush type single pole one-way 16 Ampere complete all as specified and directed.
S & F of 6 Ampere socket outlet flush type, multi purpose suitable for 2 and 3 pins (Total 5 Pins) complete all as specified and directed.
S & F of socket outlet two-in-one, 3 pin each suitable for 6 and 16 Ampere flush type with shuttered complete all as specified and directed.
S & F sheet metal enclosure for DBs (Double door type) when MCBs to be used single pole and neutral 8 ways including blanking plate as required with 200 Amps rated bus bar, 240 volts fixed sunk/flush to the wall or niche complete all as specified and as directed including necessary brick work and plaster to match with the existing surface complete all as specified.
S & F MCB DP, 240 Volts, AC, B curve, 10 KA, 40 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
S & F MCB single pole, 240 Volts, AC, B curve, 10 KA, 6 to 32 Amps (10 KA 'B' rupturing capacity) complete all as specified and as directed
M&L for sub main wiring two single core 6Sqmm(nominal area) multi-strand copper conductor FRLS PVC insulated and unseathed cable drawn in and including non metalic PVC regid conduit medium grade of suitable size with all standerd fittings, concealed including one run of continous PVC insulated stranded copper conductor FRLS cable 6 sqmm for earth continuty complete all as specified and directed. Note:- Rate quoted shall be deemed to include cutting chases for concealed conduit and making good incement mortar(1:4) or PCC (1:2:4)
Supply , laying jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 50 Sqmm 3.5 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etcl, complete all as specified and directed Note:- Excavation and earth work , sand cushioning, brick protection and GI pipes for protection shall be measured and paid for separtely.
Supply , laying jointing and commissioning, LT under gound cables XLPE insulated screened PVC bedded galvanized steel strip armoured electric powder cable (heavy duty) with alumininum conductor cross sectional are 25 Sqmm 3.5 core LT, 1100 volts grade , laid in trenches , along poles or passing with through pipe or laid under floor or through/ on walls etc, complete all as specified and directed Note:- Excavation and earth work , sand cushioning, brick protection and GI pipes for protection shall be measured and paid for separtely.
Excavation in trenches in soft/loose soil not exceeding 1.5 meter wide and not exceeding 1.5 meter deep for laying of cables and foundation of poles etc. and getting out complete all as spceified and directed.
Returning, filling in trenches (soil) including spreading leveling and well ramming in layers not exc 25 cm thick complete all as specified and directed.
Removal of surplus excavation soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed.
M&L sand cushioning with a layer of dry river sand 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts. Complete all as specified and directed Note: Punned down thickness (overall 18cm), shall be considered for measurement and payment.
M&L, locally available , sub class 'B' bricks (old size) laid flat and dry in trenches over the cable for protectionprependicular to the direction of cable adjacent to each other complete all as specified and directed.
M&L, GI pipe light grade 40 mm dia bore for cable protection fixed to pole or under road/ pavement, complete including MS clamps, nuts, bolts etc all as specified and directed.
Supply, install, testing and commissioning factory made tested LT panel board cubical outdoor type of size 0.75 x 0.75 x 0.40 mm plate mounted suitable for , 415 volts 3 phase, 4 wire,50 HZ AC supply system having bus bar chamber with insulated aluminium bus bar of rating 400 Amp installed on proceline/ SMC insulator. The panel shall be dust and vermin proof IP -65 class protection and made of 3.15 mm CRCA MS sheet and 40X40X6 mm thick MS angle iron frame work, powder coated finished over one coat of red oxide on out side surface and painted in side with two coats of red oxide primer and rear opening type with apran for cable entery closing locking arrangement including internal wiring with PVC insulated solid copper conductor FRLS cable 1100 volts grade of appropriate size (but not less than 4.0 sqmm) and comprising of the following including necessary PCC in 1:2:4 type B1 using 20mm graded stone aggregate for platform of suitable size etc all as deviated with the following fitments:- (a) MCCB 4 pole 415 volt 250 amp rating breacking capacity 36 KA incoming (Adjustable Overload 40-100%). (b) Bus bar: Providing suitable size of Bus bar of aluminium 400 amp rating with coloured heat shrinkable insulated sleeves 415 volts mounted on proceline/ SMC insulator
Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.5 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe,funnel,wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the water- ing pipe,bends,elbows shall be included in the unit rate.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing not less than 4 Kg/Sqm.
Supply, fixing, intallation and testing Water cooler 120 ltrs, nominal cooling capacity of 80 ltrs/Hrs electric driven single phase 230 Volts, 50Hz, including necesssary water connection required at site, complete all as specified and directed (Make : Blue Star, Voltas, Usha)
Supply and fixing, voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA, complete all as specified and directed
Supply and fixing, Water purifier RO 25 Ltr capacity suitable for single phase 230 Volts, 50Hz, complete all as specified and directed
Note : The total amount shall subject to adjustment of Credit for old materials as per Schedule of Credit.
kapoor and co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .