Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
10 Oct 2022, 6:00 pmClosed
CWE SRI GANGANAGAR
HQ CWE POST BOX 48 SRI GANGANAGAR-335001 (Rajasthan)
CWE/SGNR/TOKEN - 22 OF 2022-23 REPAIR/MAINT TO UNDERGROUND OVERHEAD HT EXTERNAL ELECTRIFICATION SYSTEM ALONGWITH OTHER CONNECTED ITEMS AT MIL STATION FAZILKA
2022_MES_551467_1
CA NO CWE SGNR T-22 OF 2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE ABOHAR
CLASS-E
CATEGORY-b(ii)
10 documents required · 10 mandatory
₹500
GE ABOHAR
₹40,000
Yes
30 Nov 2022
12 Sept 2022
12 Oct 2022
12 Sept 2022
10 Oct 2022
26 Sept 2022
Amount
Excavation in trenches any type of soil , n exc 1.5m wide and n exc 1.5m in depth , for foundation , etc or for shaft, well, cesspits , manholes , pier hole etc n exc 1.5 m in depth and getting out for laying of cable complete all as specified and directed by Engr-In-Charge.
Returning , filling in including, spreading , levelling , watering and well reamming in layers not exc. 25 cm complete all as specified and directed by Engr-In-Charge.
Removing excavated material n exc 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed by Engr-In-Charge.
M&L for Sand filling under flooors, in trenches or in foundation for cable protection including and consolidation complete all as specified and directed by Engr-In-Charge.
M&L for cement concrete in foundations, filling and mass comcrete type D2 1:4:8 with 40 mm graded stone aggrigate for foundation of pole etc complete all as specified and directed by Engr-In-Charge.
M&L for providing cement concrete type C:2, 1:3:6 using 40 mm stone aggregate in foundation, roof,kerb or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-In-Charge.
M&L for providing cement concrete type B1, 1:2:4 using 20 mm stone aggregate in foundation, roof,kerb or mud stops, rounded or chamfered on edges complete all as specified and directed by Engr-In-Charge.
M&L for boring hole across the road/plinth/hard standing by trench less technology method suitable for up to 100 mm bore pipe for 0.4 mpa working pressure for cable passing without damaging Road/plinth/floor complete all as specified and directed by Engr-In-Charge.
Takng out old unserviceable under ground HT cable upto 185 sqmm from trenches/floor/road/pipe/along poles including taking out old bricks complete all as specified and directed by Engineer-in-charge. (Note:- Excavation,earth work required for item shall be measured and paid seperately under respective items of BOQ.)
Supplying, laying, jointing and testing XLPE insulated,screened,PVC beded,galvanised steel strip or wire armoured,clectric power cables (heavy duty)with aluminium conductor HT cable 11000 volts grade with cross sectional area 95 Sqmm 3 core laid in trenches/ ducts/ along poles/ through pipes complete all as specified & directed by Engineer-in- charge. Note: Excavation & earth work shall be measured & paid separately under appropriate item of this Schedule.
All as per Item No.10 above but HT cable 11000 volt grade with cross sectional area 120 sqmm 3 core complete all as specified and directed by Engr-In-Charge.
All as per Item No.10 above but HT cable 11000 volt grade with cross sectional area 185 Sqmm 3 core complete all as specified and directed by Engr-In-Charge.
Laying only HT UG Cable of size 3 Core , 95 to 185 Sqmm, 11000 V grade PVC/XLPE insulated, PVC sheathed armoured conductor laid in trenches/Road/paths/ on poles through GI protection pipe complete including connection of cable at both ends with suitable size of glands, aluminium lugs complete joining, testing and commissioning including disconnecting and removing existing UG Cable complete all as specified and directed by Engr-In-Charge. Note: 1. HT UG Cable shall be laid against retrived Serviceable cable under relavent items of the schedule. 2. Earth work for the cable removing, laying measured and paid separately under relevent items of the schedule.
S&F un-reinforced precast concrete cable cover class HVP type 1 with peak, size 300mmx180mmx40mm laid flat length of cover across the length of cable and old US PCC cover to be disposal off 100 mtr away from the site complete all as specified and directed by Engr-In-Charge.
Laying only old bricks full size of useful obtained from excavation against cable shifting/rerouting complete all as specified and directed by Engr-In-Charge.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified. Make:Denson,M-Seal/Birla 3M/CCI or equivalent
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-In-Charge. Make: Denson,M-Seal/Birla 3M/CCI or equivalent
S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-In-Charge. Make: Denson,M-Seal/Birla 3M/CCI or equivalent
S&F cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm complete all as specified and directed by Engr-In-Charge. Make: Denson,M-Seal/Birla 3M/CCI or equivalent
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm complete all as specified and directed by Engr-In-Charge. Make: Denson,M-Seal/Birla 3M/CCI or equivalent
S&F Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm. complete all as specified and directed. Make: Denson,M-Seal/Birla 3M/CCI or equivalent
M&L for fabrication of cross arms bracings supports,clamps and back plates,iron stainer, water gate, ladder for clear water tank etc as required structural steel section including nuts, bolts, washers, welding,bending, cold or hot, drilling holes for bolts in any shape or size and including of one coat of primer and one under coat and one finishing coat of paint complete all as specified and as directed by Engr in charge.
M&L for painting of old painted surfaces with synthetic enemel paint to HT steel tubbular pole 11 mtr long including clamps,brackets,chanels,cross arms,bracing support and supporting pipe of cables etc including zebra painting at bottom up to 1.5 mtr above from the PCC couping and writing pole No with white paint complete etc complete all as specified and directed by Engr-In-Charge.
All as per item No.23 herein before but for 4 pole structure including cross arm,bracings complete all as specified and directed by Engr-In-Charge.
All as per item No.23 herein before but for 2 pole structure including cross arm,bracings complete all as specified and directed by Engr-In-Charge.
S & F GI tube light grade galvanised of size 100 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
S & F GI tube light grade galvanised of size 80 mm with all fitting and fixed to wall and celling or laid in floors/under road etc complete all as specdied and directed by Engineer-in- Charge.
S&F in replacement of pin type,porcelain,vitreous,white,brown or green insulator including one galvanised mild steel spindle,two galvanised iron washers and one galvanised iron nut, 150 mm height,150 mm dia for 11000 volts grade complete all as specified and directed by Engr-In-Charge.
S&F disc type insulator, porcelain,vitreous 145 mm high and 255 mm dia ball and socket type,white,brown or green 'Two in series' assembly for tension with tension clamps for conductors,suitable for working pressure 11000 volts grade complete all as specified and directed by Engineer-in-charge.
S&F in repair loop type insulator, vitrous porcelain, white brown or green large size with overall dimensions 90 mm X 140 mm clearance of hole 25.5 mm dia complete all as specified and directed by Engineer-in-charge.
S&F in replacement of galvanised stay wire with stay strand 7/4mm complete all as specified and directed by Engr-In-Charge.
Supply and fix stay assembly complete with accessories as shown electrical plate No. 1 of SSR Part I for HT poles with 20 mm dia stay rod complete all as specifed. Note: Loop type insulator excavation and concrete will be measured and paid seperately in relevant item of sch.
Supply and fix in replacement of ACSR conductor, steel rainforced of required size or guage complete all as specified and directed by Engineer-in-charge.
Supply and fix Vice type connectors of size 4 to 7mm consisting of two brass plates,and two steel bolts and nuts for 2 conductors of equal or unequal sizes, for non-tension connections 'including treatment of connector and ACSR conductor with conducting jelly complete all as specified and directed by Engr-In-Charge.
Supply and fix Vice type connectors of size 10 to 13mm consisting of two brass plates,and two steel bolts and nuts for 2 conductors of equal or unequal sizes, for non-tension connections 'including treatment of connector and ACSR conductor with conducting jelly complete all as specified and directed by Engr-In-Charge.
Supply and fix Vice type taps, consisting of two brass plates and one bolt and nut for onnecting 2 equal or unequal size conductors for service wire of size 3 to 10 mm complete all as specified and directed by Engr-In-Charge.
Supply and fix Vice type taps, consisting of two brass plates and one bolt and nut for onnecting 2 equal or unequal size conductors for service wire of size 10 to 14 mm complete all as specified and directed by Engr-In-Charge.
Supply and fix Compression/crimping type sleeve joints of size Upto 10mm dia of conductor wire overall for jointing conductors/jumper connections including treatment with conducting jelly complete all as specified and directed by Engr-In-Charge.
Supply and fix Compression/crimping type sleeve joints of size Above 10mm dia of conductor wire overall for jointing conductors/jumper connections including treatment with conducting jelly complete all as specified and directed by Engr-In-Charge.
Supply and fix Galvanised steel wire 3.15 or 4mm dia for earth wire complete all as specified and directed by Engr-In-Charge.
Supply and fix in replacement of cradles,hexagonal/rectangular,fabricated with Galvanised steel wire 3.15 mm or 4 mm dia, for LT/HT guard wire and craddles of required size or span complete all as specified and directed by Engineer-in-charge.
Supply and fix Anti-climbing device; spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed by Engr-In-Charge.
Supply and fix Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size complete all as specified and directed by Engr-In-Charge.
S&F in replacement of HT 11 KV Air break switch, gang operated, complete with all acessories, mounted on insulator and steel frame, with operating mechanism working from ground level, for current rating up to 200 Amps including GI pipe of suitable size,clamps,nuts,bolts amd washers etc complete all as specified and directed by Engr-In-Charge.
S&F in replacement of HT 11 KV Air break switch, gang operated, complete with all acessories, mounted on insulator and steel frame, with operating mechanism working from ground level, for current rating up to 400 Amps including GI pipe of suitable size,clamps,nuts,bolts amd washers etc complete all as specified and directed by Engr-In-Charge.
S&F in replacement of lightning arrester expulsion type complete with all fittings, transmission class, discharge capacity 65 Kilo amp suitable for 11000 Volts complete all as specified and directed by Engr-In-Charge.
S&F in replacement of drop out fuse unit two post insulator per pole complete complete with FRP fuse barrel channel type of capacity 200Amps,11000 Volts with all acessories including nuts,bolts and washer etc complete all as specified and directed by Engr-In-Charge.
M&L for filling of aggregate for loose filling of size 40 mm to 80 mm graded brocken stone aggrigate pices complete all as specified and directed by Engineer-in-charge.
M&L for disconnecting HT & LT side cables of follwing indoor/outdoor transformer of capacity 50 KVA to 500 KVA and earth strip from body and neutral of transformer mounted on two pole/four pole structure/staging/sub stn and taking down the transformer manually/using mechanical means and lifting loading and transportation to MES store yard/site to civil workshop for repair and opening of covers,draining out existing transformer oil,lifting of core,cleaning oil tank using chemicals,cleaning of core after removing HT/LT winding,re-assembling of new HT/LT windings with core varnishing heating and bringing back the same after repairs to the same point all as specified and directed by Engineer-in-charge. Note: (i) Rewiding of HT/LT coil any type/material,dihydration of transformer oil reassembling after repair etc.will be measured and paid seperately under relevant item of the schedule. (ii) Spare part shall be measured and paid seperately as supply only and cost of fixing and connection of spare shall be deemend to included in the quoted rate of the above items.
M&L for re-winding of 11 KV HT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for re-winding of LT coils with super enemelled best quality copper wire of existing guage with superior quality insulation material for transformer of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for assembling of HV and LV coils including necessary insulation with paper boards and varnishing,making internal connections,drying,removal of moisture from core and coils heating etc complete including testing of transformer on full load of capacity upto 500 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic LV bushing complete with bushing stud (brass metal) for transformer of capacity 50 KVA to 315 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic LV bushing complete with bushing stud (brass metal) for transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
Dehydreation and filteration of exisitng transformer oil for transformer of any capacity using centrifugal plant to eliminate foreign particals and to improve die electric straingth not less than 40 KV for one minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete all as specified and directed by Engineer-in-charge. Note: Transformer oil required for toping up shall be measured and paid for seperately under respective item of BOQ.
Supply and topping up to filling of fresh transformer oil conforming to IS-335 having die electric strength not less than 50 KV in existing transformer installed at different locations complete all as specified and directed by Engineer-n-charge. Make: Transol/Power oil/Savita
Supply and fixing in replacement of ceramic HV bushing complete with bushing stud (brass metal) for transformer of capacity 100 KVA to 250 KVA complete all as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of ceramic HV bushing complete with bushing stud (brass metal) for transformer of capacity 315 KVA to 500 KVA complete all as specified and directed by Engineer-in-charge.
M&L for supplying and refixing in replacement silica cork rubberised gasket, 5mm thick for transformer of capacity 100 KVA to 500 KVA complete all as specified and directed by Enginer-in-charge.
Disconnecting transformer of capacity 50 to 100 KVA , indoor/outdoor from HT/LT side carefully at site, dismantling carefully and removing primary and secondary terminals, top cover, conservator tank, neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers, cleaning of terminals, inspection of core, supply and replacing the 5 mm thick rubberised cork sheet gasket to leak proof seal under relevent item of this schedule for tank top cover and reassembling the complete dismantling items by replacing unserviceable minor spares such as nut, bolts, washers, expulson vent diaphram, bush seals and filling drained out transformer oil after filtration to eliminate foreign particals and to improve die electric straingth not less than 40 KV for one minute in 2.5 mm electrode gap as per relevant IS and to bring the acidity within the permissible limit complete and reconnecting the HT/LT supply cable ends at the site and testing complete all as specified and directed by Engr-In-Charge.
All as per item No 60 here in before but transformet of capacity above 160 KVA and up to 300 KVA complete all as specified and directed by Engr-In-Charge.
All as per item No 60 here in before but transformet of capacity 315 KVA to 500 KVA complete all as specified and directed by Engr-In-Charge.
Taking out old unserviceable defective HT bushings from transformers by opening carefully primary and secondary terminals top cover conservator tank neutral earth strips and draining out transformer oil to the required level and storing carefully in cleaned containers for fixing porcelain bushing with brass studs under relevant items of the schedule and supply and fixing minor spares like nuts,rubber bush and washers connecting to winding and reassembling the complete dismantling items with same position, including reconnecting HT and LT sides by relacing suitable nut,bolts and lugs,testing and commissioning The transformer 50 KVA to 250 KVA capacity complete all as specified and directed by Engr-In-Charge.
All as per item No 63 here in before but HT bush for transformer of capacity 300 KVA to 500 KVA complete all as specified and directed by Engr-In-Charge.
All as per item No 63 here in before but LT bush for transformer of capacity 300 KVA to 500 KVA complete all as specified and directed by Engr-In-Charge.
Taking out old unserviceable drain cocks from the transformers and Supply and fix new gun metal gate valve 25 mm bore along with brass/ gun metal dummy cap with rubbber washers as required at site complete all as specified and directed by Engr-In-Charge.
Supply and replace silica gel in to the serviceable breathers of transformers all as specified and directed by Engr-In-Charge.
Supply and replace silica gel breather by connecting required short length GI pipe of existing size with conservator oil tank for transformer of capacity 50 KVA to 160 KVA all as specified and directed by Engr-In-Charge.
All as per item No. 68 above here in before but for transformer of capacity above 200 KVA and up to 315 KVA all as specified and directed by Engr-In-Charge.
All as per item No.68 above here in before but for transformer of capacity above 315 KVA and up to 400 KVA all as specified and directed by Engr-In-Charge.
M & L for preparation of old painted surfaces of HT/LT transformers of capacity 50 KVA to 160 KVA including removing oilly and greasy spots and applying one coats of synthetic enamel paint including white wash to transformer foundation plinth and lettering with white paint as MES NO/SM No, capacity, year of installation, serial No over coat on black paint complete all as specified and directed by Engr-In-Charge.
All as per item No.71 here in before but transformer of capacity exceeding 160 KVA but not exceeding 300 KVA complete all as specified and directed by Engr-In-Charge.
All as per item No.71 here in before but transformer of capacity 315 KVA to 400 KVA complete all as specified and directed by Engr-In-Charge.
Shifting of transformers of capacity 50 KVA to 300 KVA from one location to another location under the area of GE Abohar as required and specified placing in position including making all connections and comissioning complete all as specified and directed by Engr-In-Charge.
All as per item No .74 here in before but transformer of capacity 315 KVA to 400 KVA complete all as specified and directed by Engr-In-Charge.
Material and Labour Framed work of Fe 410-W (Gde-E- 250)quality-A as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging also fastening and fixing complete as in compound guards of transformers, four pole/two pole structures in sub stations incuding painting of two coats of enamel paint over one coat of zinc coating primer complete all as specified and directed by Engr-In-Charge.
M&L for Steel wire fabric Welded steel wire fabric supplied and fixed complete to wood or steel members not exceeding 4 kg Weight per square metre complete all as specified and directed by Engr-In-Charge.
Supply and fix self adhesive reflective radium stickers 75 mm wide around the street light poles 1.5 above ground level complete all as specified and directed by Engr-In-Charge.
Taking down the HT Vacuum circuit breaker of capacity 400 Amps , 11 KV 250 MVA for servicing, repairs replacement of defective/wornout components and reassembling complete comprisng of the following including testing and commissioning of the following including testing and commissioning to the entire satisfaction of Eingineer-in-charge.
(i) Dismantling the VCB from the enclosure consisting of vacuum interrupter assembly, socket contacts, checking the serviceablility of the following parts carefully including cleaning, adjustments, replacements, of defective/won our parts and re-assembling the complete all as specified and directed by Engr-In-Charge. (a) Cleaning the external surface of bushing with CTC or liquid ammonia to remove the accumulation of dirt or any other deposits. Inspection of bushings and make sure that vibration due to breake operation have not caused the bushings to move resulting mis alignment of contacts. (b) Checking the vacuum interputer assemnbly and contact Checking the alignment of contacts and setting the contact surfaces to bare firm and uniform pressure and adjust the gap as per manufacture tolerance. Badly potted contact needs to be replaced Note: Contacts shall be ordered saperately. (c) Checking the breaker bushing of bus bar and circuit side inspecting the interval surface carefully for any charging/tracking, replacement of bushings.
(ii) Dismantling the spring Charging mechanism of VCB, checking the operations of closing/tripping through closing/tripping coils electrically as well as manual charging including cleaing adjustements and replacement of defective/worn out parts re-assembnly complete for the following:- (a) Checking the ratchet wheel assembly, driving and charging parts including replacement of defective ratchet wheel and like parts. (b) Checking the operation mechanism of breaker and ensure its operation freely through lentyire stroke. Parts which shows excessive wear nd tear to be replaced or adjusted as per manufactures tolerance. (c) Checking of operating voltage watt mechanism termanials tripping arrangement for positive tripping. Contacts to be examined for their condition and operation. Dress the pitted contacts and replace if necessary. (iii) Review the adjustement of all pressure switched land lockout devices. (iv) Inspecting all bolts, nuts pins and collar pins and inplace and they are tight and opened properly. Note : (a) Checking the ratchet wheel assembly, driving and charging parts including replacement of defective ratchet wheel and like parts. (b) cost of additional hardware like bolts, nuts, washers and springs, washers, petroleum jelly etc, to put the breaker in serviceable condition is deemed to be included in the rated quoted. Inspection cleaning and re-lubrication of circuit breaker
Taking down old unserviceable Circuit spout connection R,Y & B 400 A from VCB breaker and supply and fix new Circuit spout connections 630 /800 A Capacity replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable Isolating socket contact 400 A from VCB breaker and supply and fix new Isolating socket contact 630 /800 A Capacity replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable VCB Bushing for soket contact 400 A from VCB breaker and supply and fix new IVCB Bushing for soket contact 630 /400 A Capacity replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable Conductor stud for socket 400 A from VCB breaker and supply and fix new Conductor stud for socket 630 /400 A Capacity replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable Tripping coil for 400A and supply and fix new Tripping Coil for630 /400 A Capacity replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable Closing coil for 400 A and supply and fix new Closing Coil for 630 /400 A Capacity replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable protection relay from VCB breaker and supply and fix new proteftion relay of 3 OC + EF for 220 volt DC 1250/ 800/630/400 AMPS replaced by unserviceable one complete all as specified and driected by Engineer-In-Charge.
Taking down old unserviceable CT ( Current Transformer) from 11 KV VCB breaker and supply and fix new CT of ratio 200-100/5+5 A (current Trnasformer) of VCB capacity 1250/800/630/400 AMPS replaced by unserviceable one complete ass as specified and directed by Enigneer-in-charge
Taking down old serviceable vacuum interrupter from VCB beaker and supply and fix new vacuum interrupter of VCB capacity 1250/800/630/400 AMPS capacity by unserviceable one complete as specified and directed by Enigneer-in-charge
Taking down old unserviceable indoor VCB LED Lamps for lighting and supply and fix suitable new LED lamps for HT Panel replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable PF Meter and supply and fix new PF Meter for HT Panel replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable Amp Meter and supply and fix new Amp Meter for HT Panel replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable Volt Meter and supply and fix new VoltMeter for HT Panel replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
Taking down old unserviceable TNC Switch and supply and fix new TNC (Trip, Neatural. Close) Switch for HT Panel replaced by unseriveable one complete all as specified and directed by Engr-In-Charge.
M&L for repair and maint of HT Air break GOD switch to removing carbon/burnt accessories and replacement of unservceable male and female contacts assembly including treatment with conducting jelly of contact points and removing/replacement of unserviceable jumpering with new ACSR conductor jumpers duly load test the HT OH lines jumpering position/points and provision for requiered minor spares like screws,nuts,bolts,washers and links are inclusive complete all as specified and directed by Engr-In-Charge. Note: Male and female contacts of HT Airbreak GOD switch will be measured and paid separately under relevant item of this schedule.
Supply only Male and female contacts of HT 11 KV Airbreak switch GOD of 200/400 amps rating complete all as specified and directed by Engr-In-Charge. Note: fixing only measured under relevant item of this schedule.
Takintg down old unserviceable TNC switch and supply & fix new TNC switch for HT panel complete all as specified and directed by Engr-In-Charge.
M&L 15 mm thick screed bed or bedding layer of cement mortar 1:4 for layiny floor finishes, etc complete all as specified and directed by Engineer-in-charge.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to galvanised iron earth strip 25x4mm thick fixed by means of bolts, nuts and washers of the earth wire galvanised iron or steel and thimbles and other end of the earth wire connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia upto 3m height above ground level and watering pipe 20mm dia GI medium grade with socket and plug 30 cm above ground level including earthwork, PCC chamber in PCC (1:3:6) type C-2 using 40mm stone aggregate, cast iron cover, wire meah etc all as shown in electrical plate No. 3 of MES Schedule Part-I of SSR-2009 complete and all as specified and direcrted by Engr-in-charge. Notes:- (i) 20 mm dia GI pipe for watering to be provided with a socket and plug and should be 30 cms above ground level. (ii) GI strip connecting upto pump,Gen set,LT panel and DBs earth connection is included in this item. (iii) GI pipe 40 mm dia protection pipe shall be provided upto Ground level.
S&F GI strip 32x6 mm with saddles and fixing screws etc. for roof conductors and down conductors above ground or fixed on structure fixed with screws and bend to any shape as required for site complete all as specified and directed by Engineer-in-charge. ---------------------------------------------------------------------------------------------------- Note : A sum of Rs. 296250.00 will be deducted on account of credit for taken down material. Please refer details on Srl Page No. 32 (Schedule of Credit) of Tender documents.
Romil Trading Co
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .