Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.0 CrAdmitted-Finance 5 5 313A S D LAYOUT TIRUPATHI ANDHRA PRADESH | TIRUPATHI | ANDHRA PRADESH | ₹1.0 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.1 Cr+₹61,430.97 (0.59%)Admitted-Finance | ₹1.1 Cr+₹61,430.97 (0.59%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Ujwala Infratech (India) Pvt. Ltd., L1 | G MURALIDARAN L2 |
|---|---|---|---|---|---|
| 1.011. Providing FHTC, infiltration well, motor set, electrical work, Pumbing main and distribution line, in Paloothu | |||||
| 1.02Providing the water supply pipe Line,with GI, pvc pipe | |||||
| 1.03 | supply of 80mm GI pipe- | 600 | M | - | - |
| 1.04 | 80mm GI elbow | 2 | Each | - | - |
| 1.05 | 80mm GI coupling | 100 | Each | - | - |
| 1.06 | 80mm GI gate valve | 4 | Each | - | - |
| 1.07 | Laying and jointing the 80mm GI pipe line | 600 | M | - | - |
| 1.08 | Provision for water meter 50 mm , page 81 of SOR TWAD | 4 | Each | - | - |
| 1.09 | Dirt box | 4 | Each | - | - |
| 1.10 | Fitting charges of meter in OHT column | 4 | Each | - | - |
Tender Value
₹1.1 Cr
EMD Value
₹1.1 L
Closing Date
24 Aug 2020, 3:00 pmClosed
Project Director
DRDA, 3rd floor, Collectorate, Theni
Implementation of Jal Jeevan Mission to provide Functional Household Tap connection to Rural Households in Paloothu Village Panchayats in K.Myladumparai Block in Theni District for the year 2020-2021
2020_RDTN_175804_1
1353/2020/D9 Dated 13.08.2020
Open Tender
Civil Works - Water Works
Item Rate
180 days
Theni
As per tender document
3 documents required · 3 mandatory
₹0
₹1.1 L
25 Aug 2020
17 Aug 2020
24 Aug 2020
17 Aug 2020
24 Aug 2020
19 Aug 2020
Amount
1. Providing FHTC, infiltration well, motor set, electrical work, Pumbing main and distribution line, in Paloothu
Providing the water supply pipe Line,with GI, pvc pipe
supply of 80mm GI pipe-
80mm GI elbow
80mm GI coupling
80mm GI gate valve
Laying and jointing the 80mm GI pipe line
Provision for water meter 50 mm , page 81 of SOR TWAD
Dirt box
Fitting charges of meter in OHT column
Pipe line works
earth work excavation in all classes of soil for pipe line trench
supply and delivery of 63mm PVC-4Ksc
63mm PVC Elbow
63mm PVC Bend
63mm PVC Endcap
Laying and jointing the 63mm pvc pipe line
Re-filling with excavated earth as per standard spesification
supply of 80mm GI pipe-
80mm GI elbow
80mm GI coupling
80mm GI gate valve
Laying and jointing the 80mm GI pipe line
supply of 50mm GI pipe-
50mm GI elbow
50mm GI coupling
50mm GI gate valve
Laying and jointing the 50mm GI pipe line
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for wate meter 90 x 75cm
Construction of Infiltration Well
Reinforced cement concrete in 1: 1 1/2: 3 using ordinary portlan cement and 20mm size hard blue granite stone (machine crushed) excluding cost of reinforcement, fabrication and placing the grills in position and excluding cost of shoring and strutting but including curing, finishing and mixing concrete using mechanical mixer machine and compaction by machanical vibrator etc., complete and as directed by TWAD Board Officers.
Sinking of 3.5 M internal dia and 4.50 M external dia below water level including all incidental charges in light (or) sandy soil
First Depth ( 0 - 2.00 )
Second Depth( 2.00 - 4.00 )
Third depth ( 4.00 - 6.00 )
Fourth depth( 6.00 - 8.00 )
Porous Concrete in CC 1: 4 ( one cement and four hard broken granite jelly size 20 MM) for steining of infitration well excluding cost of centering but including curing etc, complete and as directed by TWAD Board Officers.
Brick Work in CM 1: 5 ( one cement and five sand) using country bricks of size 22 X11 X5 CM for steining of 45 CM thick for infiltration well including curing etc complete and as directed by TWAD Board officers
Centering for sides and soffits of R.C.C items including strutting upto 3.3 mt height using MS sheets of size 90cmx60cm and stiffend with welded MS angle of size 25mmx25mmx3mm laid over silver oak (country wood) joists of size 10cmx6.5cm (space at about 90cm c/c) and supported by casurina props of 10cm to 13cm dia 90cmx60cm and BG10 guage (spaced at 75cm c/c) complying with standard specification etc., complete as directed by the TWAD Board Officers.
Plane Surface 0.00 - 3.30 M above GL
Curved Surface 0.00 - 3.30 M above GL
Supply, delivery, fabrication and placing in position of steel rod for reinforcement for binding ring, pillasters, roof slab, well curb including cost of binding wire and labour charges etc, complete and as directed by TWAD Board Officers
Plastering in CM 1:3 (one cement and three sand) 10 mm thick including curing etc, complete and as directed by TWAD Board Officers)
Plastering in CM 1: 5 (one cement and four sand) 20 mm thick including curing etc, complete and as directed by TWAD Board Officers)
Supply, delivery and fixing in position of 50 MM thick RCC Manhole cover of size 0.60 X 0.60 M with necessary reinforcement and MS angle of Size 50 X50 X 6 MM thick fixed alroud the edges of the slab complete and as directed by TWAD Board Officers
Supply, delevery and fixing of CI steps in position at 30 CM staggered manner and as directed by TWAD Board officers
Providing ventilating arrangements by fixing in position of 160 MM OD PVC 6 KSC pipe with PVC cowl and as directed by TWAD Board officers.
Providing confirmatory bores to ascertain sand depth and locating well site before commencing the work
Providing for cutting edge using 12 Guage MS sheets including the cost of fabrication, welding and placing in position in the curb including supply of MS sheet
Colour washing the outside of well plastered surfaces and side of the roof
Plugging the bottom of the well with coarse sand of approved sizes and grade and as directed by the TWAD Board officers
provition for the diversion of water flow by using the sand bags to safety of the execution zone and as per the standard specification
Motor set,electrical works for Infiltration Well
Supply and delivery of 10.00 HP three phase open well sub mersible (Mini) pump set as per IS 14220 without Panel Board having duty condition of 250 LPMx 125 m Head
Supply and delivery of 10.00 HP three phase panel board with two level Guard and Auto Start Suitable for 7.50 HP open well submersible pumpset
4.00 Sqmm 3Core copper cable -flat type copper
50 mm GI pipe-medium
50 mm GI Bend
50 mm GI Coupling
50 mm x 80 mm GI Reducer Heavy
Supply and run of 4 of 4 sqmm ( 56/0.30 ) PVC insulated Single wire multi strand fire retardent flexible copper cable with ISI mark conforming to IS :- 694 /1990 for 3 Phase
7/20 CI Wire
64A Fuse Unit
24" x 18'' Stater Board(Wood)
Labour charges for the erection of 10.00 HP sub mersible pump set in the bore well including fixing and jointing open well submersible cable with proper clamps up to the starter to required depth and also fixing of riser pipes to the required depth valve erection charge
Supply and fixing 6 way SP DB 16A DPIC switch of 500 V ( side lendle ) with F & N on suitable TW board with PWD earthing
80mm GI pipe for Anchorage into the Ground
Anchorage clamp set
Pipeline From Infiltration Well to Paloothu
Earth work excavation in all classes of soil for pipe line trench
supply and delivery of 90mm pvc pipe -6ksc
Laying and jointing the pvc pipe line
supply and filling with sand including cost and conveyance
Re-filling with excavated earth as per standard spesification
80mm Gi Pipe
80mm GI Coupling
80mm GI Elbow
80mm Gi Bend
Laying Of GI Pipe line
80 mm GI Flangeset
80 mm GI H Nipple
80 mm GI Union
90 mm PVC FTA
90 mm PVC Bend
Functional Household Tap Connection(From PVC Pipe)
Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around. 20mm (1/2”)
Supply, delivery and fixing of stainless steel flow control valve having stainless steel 202 Grade body and stainless steel ball in 304 Grade . The average flow rate of each model from 3 m to 12 m inlet pressure head to be tested and supplied with FCRI, Palakad and test certificate shall be furnished. The flow control valve shall have external threading and including packing, forwarding and transportation and as directed by the TWAD Board Officers. - 15mm size flow control valve with an average flow rate of 5-10 lpm.
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRCNSF LTD, UK. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRCNSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes. 20mm (1/2”)
Supply and delivery of U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mmx1/2" suitable for 20mm OD MDPE pipes.
Earth work excavation Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandyand depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply in the following type of soils as directed by Departmental officers (As per Revised data 2017-18)
Lowering, laying and jointing of MDPE pipes upto 40mm Dia etc., complete
Refilling the basement with excavated Soil (other than sand) in layers of not more than 15cm thick, watering, well ramming, consolidating, complying with standard specification
Labour Charges of House Hold Connection including All Charges
Restoration of road cut portion
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
2. Providing FHTC, Pumbing main and distribution line, in Paloothu Devarajnagar
Providing the water supply pipe Line,with GI, pvc pipe
supply of 80mm GI pipe-
80mm GI elbow
80mm GI coupling
80mm GI gate valve
Laying and jointing the 80mm GI pipe line
Provision for water meter 50 mm , page 81 of SOR TWAD
Dirt box
Fitting charges of meter in OHT column
Pipe line works
earth work excavation in all classes of soil for pipe line trench
supply and delivery of 63mm PVC-4Ksc
63mm PVC Elbow
63mm PVC Bend
63mm PVC Endcap
Laying and jointing the 63mm pvc pipe line
Re-filling with excavated earth as per standard spesification
supply of 80mm GI pipe-
80mm GI elbow
80mm GI coupling
80mm GI gate valve
Laying and jointing the 80mm GI pipe line
supply of 50mm GI pipe-
50mm GI elbow
50mm GI coupling
50mm GI gate valve
Laying and jointing the 50mm GI pipe line
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for wate meter 90 x 75cm
Functional Household Tap Connection(From PVC Pipe)
Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around. 20mm (1/2”)
Supply, delivery and fixing of stainless steel flow control valve having stainless steel 202 Grade body and stainless steel ball in 304 Grade . The average flow rate of each model from 3 m to 12 m inlet pressure head to be tested and supplied with FCRI, Palakad and test certificate shall be furnished. The flow control valve shall have external threading and including packing, forwarding and transportation and as directed by the TWAD Board Officers. - 15mm size flow control valve with an average flow rate of 5-10 lpm.
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRCNSF LTD, UK. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRCNSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes. 20mm (1/2”)
Supply and delivery of U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mmx1/2" suitable for 20mm OD MDPE pipes.
Earth work excavation Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandyand depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply in the following type of soils as directed by Departmental officers (As per Revised data 2017-18)
Lowering, laying and jointing of MDPE pipes upto 40mm Dia etc., complete
Refilling the basement with excavated Soil (other than sand) in layers of not more than 15cm thick, watering, well ramming, consolidating, complying with standard specification
Labour Charges of House Hold Connection including All Charges
Restoration of road cut portion
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
3. Providing FHTC, Pumbing main and distribution line, in Kombukaranpuliyur
Providing the water supply pipe Line,with GI, pvc pipe
supply of 80mm GI pipe-
80mm GI elbow
80mm GI coupling
80mm GI gate valve
Laying and jointing the 80mm GI pipe line
Provision for water meter 50 mm , page 81 of SOR TWAD
Dirt box
Fitting charges of meter in OHT column
Pipe line works
earth work excavation in all classes of soil for pipe line trench
supply and delivery of 63mm PVC-4Ksc
63mm PVC Elbow
63mm PVC Bend
63mm PVC Endcap
Laying and jointing the 63mm pvc pipe line
Re-filling with excavated earth as per standard spesification
supply of 80mm GI pipe-
80mm GI elbow
80mm GI coupling
80mm GI gate valve
Laying and jointing the 80mm GI pipe line
supply of 50mm GI pipe-
50mm GI elbow
50mm GI coupling
50mm GI gate valve
Laying and jointing the 50mm GI pipe line
Provision for 50 mm Water meter - TWAD SOR PAGE 81 , 16 clause
Water meter Dirt BOX
Water meter erection charges
Provision for pit for wate meter 90 x 75cm
Functional Household Tap Connection(From PVC Pipe)
Providing suitable dia non corrosive engineering plastic moulded Clamp Saddle with SS 304 threaded metal inserted for tapping outlet suiting for ½”, 3/4” &1” clear bore and with wide plastic strap (Engineering Plastic) with SS 304 suitable bolts & nuts. Saddle to have sealing of Thermo plastic elastomeric (TPE) material around. 20mm (1/2”)
Supply, delivery and fixing of stainless steel flow control valve having stainless steel 202 Grade body and stainless steel ball in 304 Grade . The average flow rate of each model from 3 m to 12 m inlet pressure head to be tested and supplied with FCRI, Palakad and test certificate shall be furnished. The flow control valve shall have external threading and including packing, forwarding and transportation and as directed by the TWAD Board Officers. - 15mm size flow control valve with an average flow rate of 5-10 lpm.
Poly Propylene compression Female Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK for connecting 15mm, 20mm and 25mm outlet points of Brass ferrule of sizes 15mm, 20mm and 25mm respectively. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
MDPE PE 80 PN16 Blue pipe as per standards ISO 4427 and Tested as per BS 6920 in WRCNSF LTD, UK. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
Poly Propylene compression Male Threaded Adaptor with metal insert of SS 304 as per standards ISO 14236 and Tested as per BS 6920 in WRC-NSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes. (As Per Table 7.0 of TWAD SR 2017-18 For HSC items) - 20mm (1/2”)
Poly propylene 90 Degree Compression elbow with compression joint at both ends as per standards ISO 14236 and Tested as per BS 6920 in WRCNSF LTD, UK suitable for 20mm, 25mm and 32mm OD MDPE pipes. 20mm (1/2”)
Supply and delivery of U PVC ball valve with one side compression end and other side female end as per ISO 4422-4 and Tested as per BS 6920 in WRC-NSF LTD, UK,size : 20mmx1/2" suitable for 20mm OD MDPE pipes.
Earth work excavation Sand, silt or other loose soil, wet sand or silt not under water light black cotton soil, sandyand depositing on bank with initial lead of 10 m and lift of 2 M in narrow trenches for laying of pipes for water supply in the following type of soils as directed by Departmental officers (As per Revised data 2017-18)
Lowering, laying and jointing of MDPE pipes upto 40mm Dia etc., complete
Refilling the basement with excavated Soil (other than sand) in layers of not more than 15cm thick, watering, well ramming, consolidating, complying with standard specification
Labour Charges of House Hold Connection including All Charges
Restoration of road cut portion
Construction of Granular Sub base by providing well graded material (25 mm to 4.75 mm IRC HBG metal @ 65 %,4.75 to 2.36mm IRC HBG metal @20%&2.36 mm below IRC HBG metal @15%)& (the material passing 425 microns sieve shall have liquid limit and plasticity index not more than 25 & 6% repectively) spreading in uniform layers with motor grader on prepared surface mixing by mix in place method with rotovator at OMC and compacting with three wheel 80-100 KN capacity and finished in accordance with the requirements of the specification and thickness as per approved plans or as directed by the Engineer (Mix -in - place method) .GRIII
Cement concrete 1:4:8 mix using 20mm ISS metal including cost and all cost and conveyance of materials and all labour charges etc complete
Cement concrete 1:2:4 mix using 20mm ISS HBG metal including cost and conveyance and all other labour charges etc complete.
Electro Chloranation Disinfection - common salt as per TWAD SOR - page no -57 clause 21.2
GST Amount for providing Service to Government Contract Works for the above Construction Works. { GST Amount is the Total GST Amount for total overall quoted amount above this row in column "BB" for all works in this package}
G MURALIDARAN
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.65 MB
Tendernotice_2.pdf
PDF • 0.28 MB
BOQ_210446.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .