| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.7 LAccepted-AOC 16 APC SARANI WARD NO 30 DESHBANDHUPARA PO SILIGURI TOWN DIST DARJEELING PIN 734004 WB | SILIGURI | DARJEELING | WEST BENGAL | 734004 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹42.5 L+₹42,653 (1.01%)Rejected-Finance C O PULOKE NEOGI SURYA SEN PALLY PO KADAMTALA 734011 DIST DARJEELING WB | KADAMTALA | DARJEELING | WEST BENGAL | 734011 | L2 | Rejected-Finance Unsuccessful bidder | |
| 3 | L3₹43.0 L+₹92,144 (2.19%)Rejected-Finance | L3 | Rejected-Finance Unsuccessful bidder | |
| 4 | L4₹43.3 L+₹1.2 L (2.87%)Rejected-Finance | L4 | Rejected-Finance Unsuccessful bidder | |
| 5 | L5₹43.6 L+₹1.5 L (3.54%)Rejected-Finance C O KALIPADA MITRA SOUTH BHARAT NAGAR NEAR JAGDISH CHANDRA HIGH SCHOOL SILIGURI DISTT DARJEELING WB 734004 | JALPAIGURI | WEST BENGAL | 734004 | L5 | Rejected-Finance Unsuccessful bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
25 Jun 2024, 6:00 pmClosed
GE AF Bagdogra
GE AF Bagdogra Bagdogra Airport PO, Dist Darjeeling, WB - 734421
CAMOUFLAGE PAINTING AND CONCEALMENT FOR CERTAIN BLDGS AND REPAIR OF INTERNAL WIRING OF CERTAIN BUILDINGS AT AFS KURSEONG UNDER GE (AF) BAGDOGRA
2024_MES_657311_1
8568/E8
Open Tender
Civil Works
Item Rate
270 days
Kurseong AF Stn
As per NIT
10 documents required · 10 mandatory
₹500
GE AF Bagdogra
₹80,000
Yes
11 Jul 2024
1 Jun 2024
27 Jun 2024
1 Jun 2024
25 Jun 2024
18 Jun 2024
Amount
Camouflage Painting Taking down cement plaster from wall including racking out joints hacking for key and scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 20 mm thick cement plaster in cement mortar 1:4 in two layers of 10 mm thick each layer, mixed with water proofing compound on top layers as per manufacturer's instructions on top layers, finished even and fair without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately as "supply only".
Supply only water proofing compound ISI marked complete.
Complete removal of existing treatment of walls/ roof of RCC and AC sheets etc and preparation of old plastered surface of walls including plasters and cornices etc and applying two coats of exterior emulsion (weather coat) over a coat of anti alkaline primer in different for camouflage and concealment of sigma II software design/ patterns approved by users complete all as specified and directed.
Internal Wiring Taking down carefully copper/aluminium point wiring complete (light, fan, plug point & power complete alongwith fittings (switches, ceiling roses, tube light fittings, bulk head fitting regulator, sockets , removing materials to store and offering credit & making good of disturb surfaces of wall/floors etc as specified & directed.
M&L for Point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FRLS type drawn through and including PVC concealed conduit (ISI marked) of adequate size and its accessories with sunk cast iron/pressed steel terminal boxes of size 1.6mm thick, with 3mm thick plastic laminated sheet cover of adequate size for one light or one fan point controlled by one switch incl 1.5 Sqmm (nominal area) copper conductor cable (multistrand), FRLS type, PVC insulated and unsheathed with colour code earth wire connected to common earth dolly at one end and metallic bodies of luminaires/ fan at other end for one light point or one fan point controlled by one switch with cables 1.5 sq. mm size complete as per site requirement and complete all as specified & directed by Engr-in-Charge. Note: Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
All as per ser item No. 6.00 above, but for One 5 Amp, 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No. 6.00 here in before, but for One 5 Amp, 5 pin socket outlet point on independent board complete.
All as per ser item No. 6.00 here in before, but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp, 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes complete.
All as per ser item No. 6.00 here in before, but one light point controlled by 2 way switches complete.
All as per ser item No. 6.00 here in before, but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete.
M&L for point wiring with 1.5 Sqmm (22/0.30mm) PVC insulated and unsheathed multistranded copper conductor cable, 1100 volts grade, ISI marked, FR type drawn through and including PVC casing capping/ PVC Conduit (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm (nominal area) copper conductor cable (multistranded) PVC insulated and unsheathed as earth wire connected to common earth dolly at one end and metallic bodies of luminaire/ fan at other end including PVC folding boards with sunmica top for mounting switches, sockets, fan regulators, accessories etc for one light point or one fan point controlled by one switch with cables1.5 sq.mm size as per site requirement and complete all as specified & directed by Engr-in-Charge.
All as per ser item No. 12.00 above, but for one 5 Amp, 5 pin socket outlet point on same board with other switches including earth wire as specified.
All as per ser item No. 12.00 here in before, but for one 5 Amp, 5 pin socket outlet point on independent board complete.
All as per ser item No. 12.00 here in before, but with 4.0 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp, 5 pin socket outlet point including PVC cable 4 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to common earth & earth terminals including boards for mounting purposes complete.
All as per ser item No. 12.00 here in before, but one bell/buzzer point controlled by one push button on the same board with other switches or independent complete.
All as per ser item No. 12.00 here in before, but one light point controlled by 2 way switches complete.
S&F bell push, flush type, 5 Amp single pole, 230 volts white finish complete all as specified & directed.
S&F switch piano flush button 5 Amp, single pole, 2 way, 230 volts, white finish complete all as specified & directed.
S&F in repair, switch piano flush button 5 Amp, single pole, one way, 230 volts, white finish complete all as specified & directed.
S&F in repair, socket outlet flush type, 5 pin 5, Amp, multipurpose 230 volts, single pole, one way, suitable for 3 pin/2pin, 5 Amp plug top white/ivory finish complete all as specified & directed.
S&F in repair, switch socket combination flush type, 5 pin, 5 Amp, multipurpose, 230 volts, single pole, one way suitable for 3 pin/2pin, 5 Amp plug top white/ivory finish complete all as specified & directed.
S&F in repair, switch socket combination multipurpose, flush type, 2 in 1 type (3 and 5 pin) 5/15 Amps, 230V, AC complete all as specified & directed.
S&F in repair, ceiling rose surface PVC, 50mm dia, 3 terminals including PVC mounting block white/ivory finish complete all as specified & directed.
S&F in repair, surface and wall mounted LED batten 20 watt - 4Ft white with aluminum housing & integrated electronic driver, high performance batten and efficacy should not less than100 lumen/watt and complete all as specified & directed.
S&F in repair, surface and wall mounted LED batten 10 watt - 2Ft white with aluminum housing & integrated electronic driver, high performance batten and efficacy should not less than 100 lumen/watt and complete all as specified & directed.
S&F in repair, LED light fitting 1x9W/ 1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size as per site requirement and complete all as specified & directed.
S&F in repair, energy efficient Street/ Roadway/ Building Security Luminaire LED fitting upto 35 watt, 230 V, AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete, including brackets and all accessories needed to fixed to the wall or pole all as per site requirement and complete all as specified & directed.
S&F in repair, Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fitting complete all as specified & directed.
S&F in repair, stepped type electronic fan regulator Socket type on the existing phenolic laminated sheet etc. as reqd complete all as specified & directed.
S&F in repair, exhaust fan, steel body, AC, single Phase, 230V of size 300mm sweep with blades, frame and louvers complete as per site requirement and complete all as specified & directed.
Taking down carefully copper/aluminium sub main wiring complete alongwith all connected accessories etc complete all as specified & directed.
M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type cable 6 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 6 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cable and one run of continuous earthing cable drawn in conduit/ casing and capping will be measured as one length of sub main with colour code Red, Black and Green. (ii) PVC conduit/ casing capping and its accessories is deemed to be included in this item rate. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type cable 10 Sqmm drawn through in and including rigid PVC heavy duty concealed conduits including 10 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cable and one run of continuous earthing cable drawn in conduit/ casing and capping will be measured as one length of sub main with colour code Red, Black and Green. (ii) PVC conduit/ casing capping and its accessories is deemed to be included in this item rate. (iii) Unit rate include for cutting chases for conduits and sinking for boxes and making good to wall, floors etc.
M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type cable 6 Sqmm drawn through in and including rigid PVC heavy duty PVC casing capping upto 32mm or PVC conduit upto 25mm on wall surface/ recessed as required at site including 6 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cable and one run of continuous earthing cable drawn in conduit/ casing and capping will be measured as one length of sub main. (ii) PVC conduit/ casing capping and its accessories is deemed to be included in this item rate.
M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible copper conductor 1100 Volts grade, FRLS type cable 4 Sqmm drawn through in and including rigid PVC heavy duty PVC casing capping upto 32mm or PVC conduit upto 25mm on wall surface/ recessed as required at site including 4 Sqmm 1100 Volts grade, FRLS type, PVC insulated unsheathed multi stranded flexible copper conductor cable as continuous earth wire and connecting to common earth terminals complete all as specified and directed. Note:- (i) Two runs of cable and one run of continuous earthing cable drawn in conduit/ casing and capping will be measured as one length of sub main. (ii) PVC conduit/ casing capping and its accessories is deemed to be included in this item rate.
Taking down carefully DB/ Sheet Metal Enclosure with existing MCBs complete & making good of disturb surfaces of wall/floors etc complete all as specified and directed.
S&F distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 415 volts, 200 Amp rated bus bar with front openable cover suitable for TP & N 4 ways complete all as specified and directed.
S&F distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240 volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 4 ways complete all as specified and directed.
S&F distribution board sheet metal enlosure double door shutter type factory made fixed flush with wall or outside on wall surface suitable for mounting isolators & MCB's 240volts, 200 Amp rated bus bar with front openable cover suitable for SP & N 8 ways complete all as specified and directed.
S&F sheet metal enclosure (factory made), VTPN Vertical Distribution Boards, IP-43 & IP-44 protection suitable for MCCB's upto 125A as as incomer, Double Door, 8 way with 250 Amps rated copper busbar complete all as specified and directed.
S&F sheet metal enclosure (factory made), VTPN Vertical Distribution Boards, IP43 protection suitable for MCCB's upto 125A as as incomer, Double Door, 4 way with 250 Amps rated copper busbar complete all as specified and directed.
S&F sheet metal enclosures with plug socket single pole and neutal with two pin and earth plug and with one MCB of 20 Amps (SP) complete all as specified and directed.
S&F in repair, MCB SP 5 to 32 Amp rating 240V, 10KA, 'C' curve complete with connection testing and commissioning complete all as specified and directed.
S&F in repair, MCB SPN 32 Amp rating 240V, 10KA, 'C' curve complete with connection testing and commissioning complete all as specified and directed.
S&F in repair, MCB SPN 40 to 63 Amp rating 240V, 10KA, 'C' curve complete with connection testing and commissioning complete all as specified and directed.
S&F in repair, MCB TP 25 to 63 Amps, 415 Volts, 50 Hz with 10 KA, 'C' curve complete with connection testing and commissioning complete all as specified and directed.
S&F in repair, MCB TPN 16 to 32 Amps, 415 Volts, 50 Hz with 10 KA, 'C' curve complete with connection testing and commissioning complete all as specified and directed.
S&F in repair, MCB TPN 40 to 100 Amps, 415 Volts, 50 Hz with 10 KA, 'C' curve complete with connection testing and commissioning complete all as specified and directed.
M&L in repair, Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6 mm thickness burried directly in ground (earth pit not less than 2.25mtr deep below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level connected to and incl galvanised earth lead wire of 4.00 mm dia by means of nuts & bolts, check nuts and washers of galvanised incl PCC pit of 1:2:4, type B-1, cover reinforced with XPM weight not less than 4 Kg/Sqm and 6mm dia bar handle, earth pit angle iron frame of size 25mm x 25mm, excavation and earth work in any type of soil, charcoal dust, salt, light grade GI watering pipe 20mm dia with funnel and wire-mesh and medium grade GI protection pipe of 15mm bore from top edge of earth plate upto main distribution board complete all to as shown in electrical plate No 3 of MES Sch 2009 (Part-I) connected main switch board all as specified and testing on completion.
S&F in repair, modular type fan regulator, AC, 230 Volts complete all as specified and directed.
S&F in repair, switch modular type, 6 Amps, one way, AC, 230 Volts complete all as specified and directed.
S&F in repair, switch modular type, 16 Amps, one way, AC, 230 Volts complete all as specified and directed.
S&F in repair, modular type bell push, 6 Amps, AC, 230 Volts complete all as specified and directed.
S&F in repair, modular type socket, 6 Amps, 2/3 pin combined, AC, 230 Volts complete all as specified and directed.
S&F in repair, modular type socket, 6/16 Amps, 2/3 pin combined, AC, 230 Volts complete all as specified and directed.
S&F in repair, modular white cover plate with frame, 2 module complete.
S&F in repair, modular white cover plate with frame, 4 module complete.
S&F in repair, modular white cover plate with frame, 8 module complete.
NOTES :- 1. The amount of schedule of credit shall be deducted from the total of this BOQ for arriving at contract sum.
SHRI P P SHARMA
M/S BIJAN CHAKRABORTY
M/S MOHAN GHOSH
M/S MANAS MITRA
INDIA DEVELOPMENT CONSTRUCTION
M/S ALPHA BETA CONSTRUCTION
M/S B K ENTERPRISE
MAN BAHADUR THAPA
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .