Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being Lowest Bid Value | |
| 2 | L2₹38.2 L+₹73,190.06 (1.95%)Rejected-AOC | L2 | Rejected-AOC Rejected being L2 bidder | |
| 3 | L3₹39.6 L+₹2.1 L (5.69%)Rejected-AOC | L3 | Rejected-AOC Rejected being L3 bidder | |
| 4 | L4₹40.0 L+₹2.5 L (6.73%)Rejected-AOC VILL P O MANKAR DIST BARDHAMAN PIN 713144 | MANKAR | BARDHAMAN | WEST BENGAL | 713144 | L4 | Rejected-AOC Rejected being L4 bidder |
Tender Value
₹43.0 L
EMD Value
₹86,500
Closing Date
19 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE PANAGARH
HQ CWE PANAGARH, MES, PO - PANAGARH, DIST - BURDWAN, WB, PIN - 713420
PROVN OF REPAIR BAY AT URO FOR REPAIR / MAINTENANCE AND BATTERY CHARGING SHED FOR 3RD LINE ALS VEHS WITH AREA DRAINAGE OF SURROUNDING AREA AT ASC BN (MT) UNDER GE PANAGARH
2022_MES_502569_1
8774/E8
Open Tender
Civil Works
Item Rate
180 days
PANAGARH
Pl refer Tender Documents
7 documents required · 7 mandatory
₹500
GE PANAGARH
₹86,500
Yes
8 Mar 2022
19 Jan 2022
21 Feb 2022
19 Jan 2022
19 Feb 2022
5 Feb 2022
60 days
Amount
B/R PORTION
Excavation in trenches not exc 1.5m wide and not exc 1.5m deep for foundation etc or for shafts n.exc 10 Sqm on plan and n.exc 1.5m in depth and getting out in soft/loose soil all as specified complete all as specified and as directed.
All as per Item No. 1.01 here-in-before but exc 1.5 m depth and not exceeding 3.0 mtrs. complete all as specified and as directed.
Excavating over areas, n exc 1.5 m deep and getting out soft/loose soil complete all as specified and as directed.
M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 (using 40mm graded stone aggregates) as in bed concrete for foundation filling & mass concrete complete all as specified and as directed.
M&L for brickwork with fly ash old sized bricks straight or curved on plan to any radius built in CM 1:4 complete all as specified and as directed.
S & F for Anodised powder coated aluminium frame for doors,windows, ventilators with one or more rebates including joining cleat for fixing etc. complete all as specified and as directed.
S&F for Anodised aluminium window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified and as directed.
S&F for Anodised powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, glazing clips, ruber neoprene packing, handles 2 Nos in each door, hinges, anodised aluminum snap beading screws etc. complete all as specified.
Removing surplus soil to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as specified and as directed.
M & L for formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams, and similar work, vertical or to batter complete all as specified and as directed.
M & L for formwork for rough finished surface of concrete (flat surface) to sides of pillars, posts, struts, piers, columns, and stanchions complete all as specified and as directed.
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc complete all as specified and as directed.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc complete all as specified and as directed.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) in columns, pillars, piers, etc.complete all as specified and as directed.
M & L for reinforced cement concrete (Design Mix) M-25 (20mm graded stone aggregate) in beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and as directed.
M & L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed.
All as per Item No. 1.18 here-in-before but 6mm to 8mm dia complete all as specified and as directed.
All as per Item No. 1.18 here-in-before but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:4 on fair faces of brick work or concrete wall surfaces & finishing the surfaces fair even and smooth complete all as specified and as directed.
Supply only Integral Water proofing compound complete all as specified and as directed.
M & L for Preparing surfaces plastered or unplastered as on new surfaces and three coats of white wash complete all as specified and as directed.
Material & Labour for mixing of Fly ash, Clinker & stone dust in proportion of 1:3:6 ( i .e 10 % Fly ash, 30% Clinker and 60% Stone dust) laying , watering , ramming and compacting with vibratory roller to get min CBR value 8% and Dry density 97 % placed at required camber and gradient complete all as specified and as directed.
M&L for broken bricks hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and as directed.
M & L for Cement concrete (1:3:6) 100 mm thick type C-2 using 40 mm aggregates as in sub base of floors complete all as specified and as directed.
M & L for Cement concrete (1:2:4) finished even and smooth without using extra cement 100 mm thick type C-2 using 20 mm aggregates as in floor finishes complete all as specified and as directed.
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade A. complete all as specified and as directed.
Forming Construction joint 30mm deep x 10mm wide filled with sealing compound grade A complete all as specified and as directed.
S & F Plates (plain or chequered) of Fe 410 -W (GdeE- 250) quality A, channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment complete all as specified and as directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. complete all as specified and as directed.
M & L for preparation of new steel surfaces and painting with synthetic enamel paint on Steel Surfaces of any description, n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint over a coat of Red oxide Zinc chrome complete all as specified and as directed.
S&F for Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
S& F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified complete all as specified and as directed.
Moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick spread, levelled and rammed including watering complete all as specified and as directed.
M & L for Cement concrete (1:3:6) Type C2 using 40 mm graded aggregates as in foundations, filling and mass-concrete complete all as specified and as directed.
M & L for PCC (1:2:4) Type B0 using 12.50 mm graded aggregate used as in copings complete all as specified and as directed.
M & L for precast RCC (1:2:4) type B1 using 20 mm graded aggregates as in Cover Slabs set in CM 1:4. complete all as specified and as directed.
S & F Low density polyethylene pipes (LDPE) of 50 mm bore of pressure rating 6 kgf/cm2 laid in trenches as in weep holes complete all as specified and as directed.
Supply, Laying and Testing of Reinforced concrete pipes class NP2 , laid and jointed complete with collars 450 mm bore complete all as specified and as directed.
M&L for Concrete bed to drain pipes including packing under, and haunching against the sides of pipes after they are laid and tested in Cement concrete (1:3:6) type C-2 for 450 mm bore pipes complete all as specified and as directed .
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, mounds, mitred/stopped end etc.complete all as specified and as directed.
Add or deduct for each 25 mm girth or part thereof over or under 30 cm ditto complete all as specified and as directed.
E/M PORTION
Material and labour for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
Material and labour for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC casing caping and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
Material and labour for wiring for 5 Amps socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc.complete all as specified and as directed.
Material and labour for wiring for 15 Amps socket out let on independent Boards controlled by one, one way switch using 4 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and as directed.
Supply and fixed switch piano flush type, single pole , 5/6 Amps, one way complete all as specified and as directed.
Supply and fixed switch socket combination, 2 in 1 multipurpose 5 pin , (5/6 Amps ) complete all as specified and as directed.
Supply and fixed switch socket combination, 5/16 Amps 5 in 1 flush type controlled by one switch complete all as specified and as directed.
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified and as directed.
Supply & fixed stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified and as directed.
Supply & fixing 01x 20 W LED extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and as directed.
Supply and fixing security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and as directed.
Supply and fixing flood light fittings 30 watts, made up of pressure dia cast aluminium housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as specified and as directed.
Supply & fixing exhaust ventilation fan of sweep 300mm with louvers, 240 volts, BEE 5 star rated, steel body,ISI marked complete all as specified and as directed.
Supply & fixing ceiling fan 1200mm size , star 5 rated, ISI mark, 240V, 50 Hz complete all as specified and as directed.
Supplying and fixing two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified and as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as specified and as directed.
Supply and fixed MCCB TPN 125 Amps, 25kA, 240 Volts,ISI marked and to be housed in DBs complete including necessry connection complete all as specified and as directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fixed MCB SP, 40 to 63 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed.
Supply and fixed MCB SPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
Supply & fixing XLPE armoured cable 25 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as specified and as directed.
Excavation in trenches not exceeding 1.5m wide and not exc. 1.5m depth and getting out in hard/dense soil complete all as specified and as directed.
Returning, filling, including spreading, leveling, watering and well ramming in layers not exc. 25cmin soft/loose soil complete all as specified and as directed.
Removal of excavated soil to a distance not exc 50 m and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and as directed.
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion complete all as specified and as directed. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Disconnecting ,taking out and removing from trenches/ducts/sleeve/on pole/wall etc existing UG XLPE insulated, armoured cable of any description, any size/core and in any position complete all as specified and directed. Note: Earth work shall be measured & paid separately under respective item. complete all as specified and as directed.
Supplying, laying, jointing & testing XLPE insulated armoured LT cable of size 70 sqmm 3.5 Core, 1100 volts grade heavy duty with aluminium conductor of the following sizes complete laid in trenches/pipe on road etc complete all as specified and directed.
Supplying, laying & fixing in replacement GI light grade pipes of size 50 mm dia for cable protection laid in trenches/floor/roof and on the walls, with all accessories, all as specified and directed.
Supplying, laying & fixing in replacement GI light grade pipes of size 40 mm dia for cable protection laid in trenches/floor/roof and on the walls, with all accessories, all as specified and directed.
M&L for PCC (1:3:6) type C2 using 40mm graded aggregate as in foundation for stay set /Pole/ FPB etc including fair finish even and fir to exposed surfaces without using extra cement complete all as specified and as directed.
M&L for PCC (1:2:4) type B-1 (with using 20 mm graded stone aggregate) as coping of pole including necessary form work as required complete as directed.
Supply, commissioning and testing Outdoor type LT Distribution Panel, weather proof, CPRI approved, Seven tank treatment powder coated factory made LT Panel board, totally enclosed, dust and vermin proof openable from front & back side, canopy headed, connected with suitable size MS angle iron frame, Overall dimension (1500 x 200 x 600)mm for main distribution Panel, fabricated with CRCA sheet 3.15mm thick sheet incluing IP - 55 protection, installed on concrete base made of PCC (1:3:6) type C1 using 20mm graded aggregate,including self locking arragement. complete all as specified and as directed. New Panel board shall comprise of :- (a) Copper Busbar rating- 400 Amps- 04 Nos (b) Indication lamp for RYB - 01 Set (c) MCCB-200 Amp, 4 pole, 36KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Incoming) (d) MCCB-160 Amp, 4 pole, 25KA Adj Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (e) MCCB-100 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (f) MCCB-63 Amp, 4 pole, 25KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-01 No(Outgoing) (g) MCB-63 Amp, 4 pole, 10KA Fixed Thermal & Fixed Magnetic setting, 415 V, 50 Hz AC-10 No(Outgoing) (h) S&F digital ampere meter 3 1/2 display incl CT having CTR 500/5-01 Nos (j) S & F digital voltmeter 0-500 V = 01 Nos
M & L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in any type of soil , charcoal dust , salt and PCC 1 : 2: 4 type B1 in chamber with RCC 1 : 2 : 4 type B1 cover slab with 6 mm dia mild steel bars at 100 mm centre to centre both ways and with 6 mm dia MS hook complete and testing of resistance complete all as specified and as directed.
M/S DEBNATH MONDAL
HIGH HILLS INFRA
ANIMA ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .