| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹19.9 LAccepted-AOC 3 4 JEEVAN DEEP BUILDING 10 PARLIAMENT STREET NEW DELHI 110001 | NEW DELHI | NEW DELHI | DELHI | 110001 | L-1 | Accepted-AOC Accepted being Lowest Bidder | |
| 2 | L-2₹22.0 L+₹2.1 L (10.3%)Rejected-AOC 94 D POCKET J AND K DILSHAD GARDEN DELHI DELHI 110095 | SHAHDARA | DELHI | 110095 | L-2 | Rejected-AOC Rejected since the agency is not the Lowest Bidder | |
| 3 | L-3₹24.5 L+₹4.6 L (23.3%)Rejected-AOC | L-3 | Rejected-AOC Rejected since the agency is not the Lowest Bidder | |
| 4 | L-4₹26.2 L+₹6.3 L (31.9%)Rejected-AOC B 3 105 PASCHIM VIHAR NEW DELHI 110063 | WEST | DELHI | 110063 | L-4 | Rejected-AOC Rejected since the agency is not the Lowest Bidder | |
| 5 | L-5₹26.3 L+₹6.4 L (32.3%)Rejected-AOC | L-5 | Rejected-AOC Rejected since the agency is not the Lowest Bidder |
Tender Value
₹30.6 L
EMD Value
₹61,283
Closing Date
7 Nov 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ARUN KUMAR SHARMA
D3-18, 3RD FLOOR, AAI OPERATIONAL OFFICES, RANGPURI, NEW DELHI-110037
ACMC FOR WINDOW, SPLIT, CASSETTE TYPE AIR-CONDITIONERS ETC., WATER COOLER AND 2 NOS. PACKAGE TYPE AIR-CONDITIONER UNITS INSTALLED AT FIRE TRAINING CENTRE, NEW DELHI (2020-22).
2020_AAI_60380_1
AAI/RHQ/NR/FTC-ACMC-AC/2020
Open Tender
Electrical Works
Item Rate
730 days
AAI OPERATIONAL OFFICES, RANGPURI
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,120
Yes
AIRPORTS AUTHORITY OF INDIA
₹61,283
Yes
10 Dec 2020
26 Oct 2020
9 Nov 2020
27 Oct 2020
7 Nov 2020
27 Oct 2020
27 Oct 2020 - 2 Nov 2020
90 days
Amount
Operation, Maintenance & Servicing of 2 nos. package AC plant having capacity of each 8.75 TR installed at Old NIAMAR of Voltas Make i/c repairing/ replacement of PCB, capacitor, relay, thermostat, gas charging, fan motor rewinding and any other damaged materials except compressor by engaging 01 no. AC mechanic (Skilled) & 01 no. helper (Unskilled) both in Six (06) days of general shift duty in each week of every month except Sunday & public holidays complete as required.
For 1st Year
For 2nd Year
All inclusive annual comprehensive repair & maintenance of 1.5 TR/ 2.0 TR Split type Airconditioner units i/c supply & replacement/ repair of defective components, rewinding/ replacement of all the fan motors, PCB, drainage pipe, capacitor, relay, electrical connection, thermostat, fan motor except gas charging, condenser copper coil & compressor complete as required (All materials for replacement/ rewinding to be arranged by contractor). 1.5 TR/2.0 TR Split type Airconditioners - Qty 76 nos.
For 1st Year
For 2nd Year
All inclusive annual comprehensive repair & maintenance of following 1.5 TR/2.0 TR Window type Airconditioner units i/c supply & replacement/ repair of defective components, rewinding/ replacement of all fan motors, PCB, drainage pipe, capacitor, relay, thermostat, electrical connection except Gas Charging, Condenser copper coil & Compressor complete as required (All materials for replacement/ rewinding to be arranged by contractor). 1.5 TR/2.0 TR Window type Airconditioners - Qty 41 nos.
For 1st Year
For 2nd Year
All inclusive annual comprehensive repair & maintenance of following 2.0 TR/3.0 TR Cassette type Airconditioner units i/c supply & replacement/ repair of defective components, rewinding/ replacement of fan motors, PCB, drainage pipe, capacitor, relay, thermostat, electrical connection except Gas Charging, Condenser copper coil & Compressor complete as required (All materials for replacement/ rewinding to be arranged by contractor). 2.0 TR/3.0 TR Cassette type Airconditioners - Qty 32 nos.
For 1st Year
For 2nd Year
All inclusive annual comprehensive repair & maintenance of following 3.0 TR/4.0 TR Tower type airconditioner units i/c supply & replacement/ repair of defective components, rewinding/ replacement of all the fan motors, PCB, drainage pipe, capacitor, relay, thermostat, electrical connections except Gas Charging, Condenser copper coil & Compressor complete as required (All materials for replacement/ rewinding to be arranged by contractor). 3.0 TR/4.0 TR Tower type Airconditioners - Qty 20 nos.
For 1st Year
For 2nd Year
Gas charging up to required capacity of unit for 1.5 TR/2.0 TR capacity of all Window/Cassette/ Split type AC unit including nitrogen pressure testing, vaccum testing & all material required, transportation etc. complete as required.
Gas charging up to required capacity of unit for 3.0TR/4.0TR Cassette/ Tower type AC unit including nitrogen pressure testing, vaccum testing & all material required, transportation etc. complete as required.
Providing and fixing insulation of Nitrile tube Foam of 25 mm thick on existing refrigerant piping along with protective Fiberglass tape, Adhesive, Clamping i/c dismantling of existing insulation etc. complete as required.
Providing and fixing insulation of Nitrile tube Foam of 13 mm thick on existing refrigerant piping along with protective Fiberglass tape, Adhesive, Clamping i/c dismantling of existing insulation etc. complete as required.
Providing insulation of Nitrile tube Foam of 19 mm thick on existing refrigerant piping along with protective Fiberglass tape, Adhesive, Clamping i/c dismantling of existing insulation etc. complete as required.
I.T.C. of Window type AC units i/c wooden frame & minor civil works as per site requirement.
I.T.C. of Split type/ Cassette type AC units i/c copper piping & minor civil works as per site requirement.
Supply and Fixing of decorative front grill of Window type AC units as per site requirement.
Supply and Fixing of following type compressor of Aircondioners i/c Welding, Gas recharging & dismantled materials to be taken as buyback by the agency etc. complete as required:
1.5 TR Rotary type
2.0 TR Rotary type
3.0 TR Scroll type
4.0 TR Scroll type
Supply, Installation, Testing & Commissioning of suitable dia. Copper Piping for suction & discharge for 1.5/2.0 TR Window/Split AC i/c nitrile rubber insulation, protecion fiberglass tabe covering etc. as complete as required.
Supply, Installation, Testing & Commissioning of suitable dia. Copper Piping for suction & discharge for 3.0/4.0 TR Cassette/Tower AC i/c nitrile rubber insulation, protecion fiberglass tabe covering etc. as complete as required.
Supply, Installation, Testing & Commissioning of Condenser Coils in Outdoor unit for 1.5/2.0 TR Window/Split AC etc. as complete as required.
Supply, Installation, Testing & Commissioning of Condenser Coils in Outdoor unit for 3.0/4.0 TR Cassette/Tower AC etc. as complete as required.
All inclusive comprehensive Maintenance Contract including repair/ replacement of all parts i/c Fan motor, Capacitor, PCB, Rewinding, Gas Charging except Compressor as per special conditions enclosed for the following type of AC units of make Blue Star Make complete as required. (i) 8 HP capacity variable refrigerant flow type air-conditioning system complete with inverter type compressor suitable for 230V for 1 no. outdoor & 3 no. 1.5 TR Split type indoor units with individual controller.
For 1st Year
For 2nd Year
All inclusive comprehensive Maintenance Contract including repair/ replacement of all parts, connecting pipes, taps, socket, connection gas charging, plumbing works, cleaning of water tank and water cooler etc. of water coolers of all capacity of all makes as complete as required.
For 1st Year
For 2nd Year
NATIONAL SAFETY ENGINEERS
PROFESSIONAL COOL TECH
HONEY COLLECTION
COOLREFENGINEERS
V Save Electronics Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .