Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.6 LAccepted-AOC | L1 | Accepted-AOC Queted Less Then Tender Value | |
| 2 | L2₹44.1 L+₹51,050.75 (1.17%)Rejected-AOC | L2 | Rejected-AOC Queted More Then Tender Value | |
| 3 | L3₹44.7 L+₹1.1 L (2.43%)Rejected-AOC | L3 | Rejected-AOC Queted More Then Tender Value |
| Sl No | Description | Qty | Unit | BEEMJI ENTERPRISE L1 | VM DEEPAK INFRA L2 | VMD CONSTRUCTION L3 |
|---|---|---|---|---|---|---|
| 1.00VELLORE DISTRICT CONSTRUCTION OF BUILDING FOR HEALTH SUB CENTRE BUILDING AT BRAMMAPURAM PANCHAYAT OF KATPADI BLOCK 15TH CFC (NHM) 2025-26 PACKAGE NO 01 | ||||||
| 2.00 | Clearing jungle including uprooting of trunk vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared for etc Complete | 375 | Sqm | 6 ₹2,250 Lowest | 6.44 ₹2,415 | 6.44 ₹2,415 |
| 3.00 | Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. Refilling the sides of foundation with excavated earth other than sand in layers of well rammed and compacted and depositing the surplus earth in places shown by the departmental officers with an initial lead of 10m and initial lift of 2m and clearing and leveling the site etc. complete complying with standard specification. | 151.55 | Cum | 322 ₹48,799.1 | 246.52 ₹37,360.11 Lowest | 290 ₹43,949.5 |
| 4.00 | Supplying and filling in foundations and basement with filling M sand in layers not exceeding 15 cm. thick, well watered rammed and consolidated etc. complete complying with standard specifications. | 24.87 | Cum | 1,629 ₹40,513.23 Lowest | 1,629 ₹40,513.23 Lowest | 1,629 ₹40,513.23 Lowest |
| 5.00 | Plain Cement Concrete 1:4:8 (one part of cement, four parts of sand and eight parts of hard broken stone) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement. | 29.43 | Cum | 5,237 ₹1,54,124.91 Lowest | 5,237.02 ₹1,54,125.5 | 5,237.02 ₹1,54,125.5 |
| 6.00 | Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site. | 89.89 | Cum | 42 ₹3,775.38 Lowest | 42 ₹3,775.38 Lowest | 49 ₹4,404.61 |
| 7.00Supplying and erecting Centering and Shuttering for soffits including necessary supports and strutting up to 3 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dial spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid). | ||||||
| 8.00 | Upto Basement | 183.93 | Sqm | 516 ₹94,907.88 Lowest | 516.5 ₹94,999.85 | 550 ₹1,01,161.5 |
| 9.00 | Ground Floor | 268.64 | Sqm | 1,033 ₹2,77,505.12 Lowest | 1,033 ₹2,77,505.12 Lowest | 1,033 ₹2,77,505.12 Lowest |
| 10.00Design Mix Concrete | ||||||
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
16 Jul 2025, 3:00 pmClosed
THE BLOCK DEVELOPMENT OFFICER
THE BLOCK DEVELOPMENT OFFICER, KATPADI
VELLORE DISTRICT CONSTRUCTION OF BUILDING FOR HEALTH SUB CENTRE BUILDING AT BRAMMAPURAM PANCHAYAT OF KATPADI BLOCK 15TH CFC (NHM) 2025-26 PACKAGE NO 01
2025_RDTN_576987_1
A2/1504/2025
Open Tender
Civil Works
Item Rate
180 days
THE BLOCK DEVELOPMENT OFFICE, KATPADI
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
₹90,000
15 Oct 2025
2 Jul 2025
16 Jul 2025
2 Jul 2025
16 Jul 2025
2 Jul 2025
Amount
VELLORE DISTRICT CONSTRUCTION OF BUILDING FOR HEALTH SUB CENTRE BUILDING AT BRAMMAPURAM PANCHAYAT OF KATPADI BLOCK 15TH CFC (NHM) 2025-26 PACKAGE NO 01
Clearing jungle including uprooting of trunk vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared for etc Complete
Earthwork excavation for foundation (for narrow excavation) to full depth as per designed in all soils and sub soils except soft disintegrated rock not requiring blasting and hard rock requiring blasting and bailing water wherever necessary. Refilling the sides of foundation with excavated earth other than sand in layers of well rammed and compacted and depositing the surplus earth in places shown by the departmental officers with an initial lead of 10m and initial lift of 2m and clearing and leveling the site etc. complete complying with standard specification.
Supplying and filling in foundations and basement with filling M sand in layers not exceeding 15 cm. thick, well watered rammed and consolidated etc. complete complying with standard specifications.
Plain Cement Concrete 1:4:8 (one part of cement, four parts of sand and eight parts of hard broken stone) using 40 mm gauge hand broken hard broken granite stone jelly complying with standard specifications in foundations and basement.
Refilling the approved good quality earth in plinths, area development etc. wherever specified in layers is not exceeding 200 mm thick, with available earth at site.
Supplying and erecting Centering and Shuttering for soffits including necessary supports and strutting up to 3 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dial spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid).
Upto Basement
Ground Floor
Design Mix Concrete
Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of M25 grade for reinforced cement ratio with plasticizer using 20mm and down concrete structural elements under controlled water graded machine broken granite stone jelly excluding the cost of centering and shuttering and reinforcement but including curing, fixing, fan clamps etc., as per standard specification and as directed by the depart- mental officers comple.
Foundation & Basement
Ground Floor
Steel Fe 500 D: Supply, fabrication and placing of reinforcement steel of high yield strength ribbed bars of various diameters and grade conforming to IS 1786 for reinforced concrete work. The work includes recoiling, straightening, cutting, bending, fabricating, and placing in position, at all levels including lead and lift, according to drawings, specifications etc. complete and supply & use of 18G black annealed binding wire double fold to tie the bars in position and providing precast cement/ PVC cover blocks for main reinforcement to ensure specified cover and complete., including all labor charges etc as directed by departmental officers.
Brick work in following Cement Mortar 1:5 using best quality Country bricks of size 8"3/4 x 41/4" X2 3/4" for foundation and basement including curing etc., complete complying with standard specification Including scaffolding curing cost of reinforcement etc. all complete as per specifications and drawings as directed by the Engineer in-charge.
Foundation & Basement
Ground Floor
Brick partition walls of 11.50cm thickness using best quality Country bricks of size 8"3/4 x 41/4" X2 3/4" in Cement Mortar 1:3 (One Cement and Three Sand) using hoop iron reinforcement if found necessary including curing etc. complete and as directed by the departmental officers. (Hoop iron reinforcement will be measured and paid for separately).
Ground Floor
PLASTERING WORK
Providing and applying 10 mm thick Cement plaster in Cement mortar 1:3 (One part of Cement and Three parts of Sand), to finishing the exposed surfaces of R.C.C. items of works such as Roof (or) floor slabs, beams, and Sun shades etc.to correct plane and level including scaffolding, hacking of surface, chiselling the undulated surface wherever necessary and curing etc., all materials and labour complete in all respects including all lead, lift and descent and as directed by the Enineer in charge. This rate includes the cost of providing Cement Mortar beadings for sun shades, steps, landing slabs, elevation etc. complete complying with standard specifications.
Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement 5 parts of sand) to walls internally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or chambering of corners, offsets, fin/bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface, chiseling the undulated surface wherever necessary and curing, etc., all materials and labor complete in all respects including all lead, lift and descent and as directed.
FLOORING AND DADOOING
Paving the floor with best quality Vertified Tiles of size 600 x 600 x 8mm of approved color, shade and quality laid in cement mortar 1:3 (one cement and three sand) 20mm thick in all floors and the top pointed with the white cement mixed same color pigments etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
Flooring with following ceramic tiles of size 305 x 305 x 6 mm laid over 20 mm thick cement mortar 1:3 (One Cement and Three Sand) base mortar over the existing slab /floor including cutting the tiles to the required size with special cutter wherever necessary, laying in position and pointing with white cement mixed with colouring pigment at the rate of 0.3 Kg./sq.m. etc., complete complying with standard specification. (The make and brand of the tiles should be got approved by Executive Engineer before use on works).
Dadoodling the walls with colored glazed tiles approved size, quality and color set in CM 1:2 10 mm thick. And pointed with suitable cement including finishing the joint and pointing flesh with walls and tile surface in all floors at the rate of 0.40 Kg /Sqm etc. complete.
Paving the four with pre-polished concrets antiskid step thes (Required shape and dereign) of 20mm thick of approved quality and motor teid in Cement Mortar 13 (One Cement and Three sand) 20mm thick and 22 05 pointed with white cement mixed with Jestbuing plament at the rate of 0.40 Kg./em curing, etc, complete complying with standard specification and as directed by the departmental officers. (The make and brand of the tiles should be got approved by Daecutive Engineer before use on works).
Providing, fabricating and fixing M.S. grills Windows, and ventilator, gates, ladders, rail pipes, nosing angles, with M.S.lugs in staircase steps etc., made out of M.S rods, flats, angles, pipes, channels etc. including necessary fixtures complete as per drawings and specifications and as directed by the Engineer
Manufacturing, supplying and fixing of stainless steel hand rails for staircase using 50mm dia 3041, grade stainless steel pipe of 1.6mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia stainless steel pipe post of 1mm thick as vertical at 900mm centre with 2 Nos of 25mm dia intermediate horizontal stainless steel pipe of 1.6mm thick in between The vertical pipe has to be welded to the 100 x 100 x 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, ect completeS.S Handrail
door with the following specification MS angels of size 40x40x6mm are used for the outer frames and M.S. angles of size 35x35x5mm for the shutter frames stiffeners with 32 x 6mm M.S flat is provided at required intervals in the shutter frame. 18-gauge C.R. sheet laid as panel in the shutter and welded intact. M.S. flat 18x5mm is welded over the 32 x 6mm M.S. flat M. Sandwitching the C.R. sheet in between additional stiffeners with
Steel door 1.10m x2.10m
Solid PVC door shutters Toilet door using 19 Gauge 19mm MS square tubes for styles and outer frames 15mm MS square square tubes for top, lock and bottom rails. The steel tubes shall be covered with 5mm thick solid PVC sheets Shutter using 6mm thick solid PVC sheets for panelling shall rigidly fixed in position including necessary furniture and fittings. The over all size of styles shall be 50mm x 30mm. The over all size of top rail, Lock rail and bottom rail shall be 75mm x 30mm The over all size of frames shall be 50mm x 45mm, with suitable rabate for housing the shutter.
Manufacturing, supplying and fixing in position of steel windows with the following lowing specifications. Outer frames of windows made of "Z" section F7D of size 33 x 25 x 3mm at 1.419kg/m and mullion "J" section (F4B) of size 46 x 25 x 3mm at 2.28kg/m and shutter section of made of F7D of 33 x 25 x 3mm at 1.419kg/m as specified in IS 7452/1990. ach openable shutter should not exceed a width of 600mm to enable separate operations and easy maintanenance. The panel of the shutters to be covered with 18 gauge cold rolled sheet of superior quality and welded intact with shutter frames. Horizontal stiffeners using 18 x 5mm MS flat at 0,70kg/m at 3Nos, for each shutter and additional diagonal stiffeners of the same MS flats at all the four corners of each shutters to the suitable length welded to the shutters, for holding the CR sheets in position firmly.
Window 1.20 mx 1.30m
Supplying and fixing Steel glazed ventilators with side hung swing shutter outer frame and shutter frames Supplying and fixing Steel glazed ventilators with side hung swing shutter outer frame and shutter framesork.
Ventilator - V1
Ventilator - V2
PAINTING WORK
Painting two coats of synthetic Enamel paint of approved colour and make over ons coat of anti corrosive Zinchromite primer over new wood/steel work, suitably prepared for ared for receiving the paint by surface scraping, rubbing applying filler etc. including cost of hiller, primer, paint all complete as per drawings and specifications
Supplying and painting the walls with two coats of oil bound distemper over one coat of water based cement primer including cost for distemper, primer, cleaning and scrapping the walls, rendering the walls smooth with necessary putty, brushes, scaffolding arrangements, labour charges, etc, as per standard specification. (The colour and shade of the distemper shall be got approved by the Executive Engineer before use of work)
Painting two coats of newly plastered wall surface with ready mixed plastic emulsion paint of first class quality and of approved colour over a priming coat including thorough scrapping, clean removal of dirt, and including necessary plaster of paris putty, wherever required etc., complete complying with standard specification.
Weathering Course Concrete using best quality broken brick jelly of 20 mm uniform gauge in pure slaked lime (NO Sand to be used (over the RCC roof slab in the proportion of brick jelly to lime being 32: 121/2 by volume laid over in single layer and 6.61 consolidated to the required slope and finished thickness and beating the concrete with wooden beaters of approved pattern, keeping the surface constantly wet by sprinkling lime, jiggery water etc. complete complying with standard specifications and as directed
Finishing the top of roof with one course of machine pressed tiles of size 230mm x 230mm x 20mm of approved quality set in Cement Mortar 1:3 (One Cement and Three Sand) 12mm thick mixed with water proofing compound conforming to ISS at 2% by weight of cement used and the joints pointed neatly to full depth of tiles with the same cement mortar mixed with red oxide and water proofing compound including curing etc., complete complying with standard specification and as directed by the departmental officers.
Providing Cup-board Shutter with frame using termite water proof plywood of 19mm thick over which laminated sheet of 0.8mm thick fixed inside the shutter and 1mm thick fixed in the outside of the shutter using fevicol along with necessary furniture fittings, such as, hydralic hinges, tower bolt, handles, multi purpose locks etc., as directed by the Departmental Officers. The design pattern, water proof plywood, laminate sheet and other materials should be got approved from the Executive Engineer befoe use on work.
PART A SANITARY FITTNGS
Supplying and fixing in position best approved quality (Oriya type) white indian type water closet $30 mm x 440 mm white glazed earthern ware of approved quality and brand with "D" or "s" trap conforming to BIS with sand cushion and forming flooring alround the closet using 40 mm broken brick jelly in lime concrete 1:2:5 (one lime, two sand and five brick jelly) 100 mm thick and finishing the top to the required slope and including giving necessary connection to CI soil pipes (including the cost of 100mm dia CI pipe for a length of 600mm) by dismantling brick masonry wall / reinforced cement concrete roof /floor slab and making good the dismantled portion to the original condition with leakages etc., complete complying with standard specifications and as directed by the departmental officer.
Supplying and fixing of Indus floor mounted white colour European water closet Parryware or equivalent, with seat cover and dual flush (3 & 6 lit) cistern having P trap with seat cover, supplying non corrosive hinges, CP bolts, nuts, washers, providing and fixing dash anchor fastners with bolts / L brackets with anticorrosive paint cutting grooves in masonry or concrete surfaces, grouting with cement concrete 1:2:4 mix, using 20mm size stone jelly, restoring the damaged portion to their original condition using required materials, fixing the water closet to perfect level, alignment, testing etc.complete.
Providing and keeping in stores, shifting to the place of installation, fixing, testing and commissioning of white coloured vitreous china under counter Regular rectangular wash basin with brackets / G.I. rag bolts and nuts painted, 32mm dia brass C.P. waste coupling, (heavy) 32mm dia brass C.P. bottle trap, 15mm dia brass C.P. Angle stop cock with flange, 15mm dia brass C.P. cold water connecting pipe, etc., The work shall include, required extension nipples, cutting /chasing and making good the walls and floors toilets. Wash Basin
Supplying and fixing of PVC water storage tank of best approved quality and make of super thick with lid of capacity of 2000 litres with accessories including giving necessary connection etc., complete as directed by the departmental officer. (The PVC water storage tank should be got approved by the Engineer before use on work) (TWAD- Pa no:89)
ELECTRICAL ARRANGEMENTS
Light/Fan point SD 25
Concealed Light point SD 26
Plug point SD 38
Concealed Power Plug Point SD 40
Ceiling Fan SD 106
Exhaust Fan SD 114
4 18W Crystal Glass LED Tube Light Fitting
TNEB meter board
Service Connection SD 66
Earth Connection SD 74
UNDER GROUND SEPTIC TANK
Earthwork for foundations and depositing on bank with initial lead of 10 ML and initial lift of 12M in sand, silt or other loose sot, wet 8.24 sarnd or sill not under water, light black soil, sandy loam and ordinary sold including excavated earth
Supplying and filling in foundation and basement with M sand in layers of not more than 10cm thick well watered, rammed and consolidated etc., complete as per standard specification.
Laying the Plain Cement concrete 1:4:8(One cement four sand and eight broken Machine crushed stone jelly) using HBG Machine creased Machine crushed stone jelly of size 40mm gauge for founding and basement including de watering if found necessary and laid in etc., complete complying with standard specification and as directed by the departmental officers. The rates inclusive of Centering, shuttering, strutting, propping, removal of form work if it is required and all leads, lifts and curing etc..
Supplying and Erecting centering for sides and soffits including necessary supports and strutting up to 3.29 M height for plane surfaces as detailed below in all floors with all cross bracings using Mild Steel sheets of size 90 x 60 cm and 10 BG stiffened with welded Mild Steel angle of size 25mm x 25mm x 3 mm for boarding laid over silver oak joists of size 10cm x 6.50 cm spaced at about 90 cm centre to centre and supported by casurina props of 10cm to 13 cm dia spaced at not more than 75 cm centre to centre etc. complete complying with the standard specification. (Payment for centering shall be given after the concrete is laid)
Brick work in following Cement Mortar using best quality of Country Bricks of size 8-3/4" x 4-1/4" x 2-3/4" for foundation and basement including curing, etc., complete complying with standard specifiction.
REINFORCED CEMENT CONCRETE 1:1.5:3 mix using 20mm machine crushed 20mm gauge hard broken granite stone jelly for all reinforced cement concrete works connected to this work excluding cenetering. shuttering and cost of reinforcement grills placed in position for etc Complete
Providing & applying 12 mm thick cement plaster in CM 1:5 (1 part of cement: 5 parts of sand) to walls internally and externally in single coat at all levels to correct line and level including chicken wire mesh at all joints of brick and concrete surfaces with minimum overlap of 150 mm in all directions, scaffolding, rounding off or champhering of corners, offsets, fin/ bands, projections, etc. and cleaning of surface, raking out joints, roughening of surface, chiseling the undulated surface wherever necessary and curing, etc., all materials and labour complete in all respects including all lead, lift and descent and as directed.
Supplying and fixing in position C.I.Manhole covers (heavy duty) mof various sizes of best approved quality and as per standard specificationsetc., complete.0.6X0.6M Size etc., complete.
Providing, machine mixing and laying on the PCC/RC.C. surface in approved panels of 25 mm thick granolithic flooring in cement concrete mix of 1:2:4 (1 Cement: 2 Sand: 4 Aggregate 10 to 12 mm thick) well vibrated, compacted including 45 x 3 mm glass dividing strip, fixed to correct level and finished 8180 smooth and cured by keeping surfaces well-covered and protected against excess of an type. (The contractor to provide for preparation of surface by cleaning, hacking and exposing aggregate to achieve the best bond and any curling, lifting or beybonding noticed shall be rectified by the contractor at his cost).
Supplying, fabricating and placing in position mild steel/Ribbed tor steel rods for all RCC works including cost of steel and binding wire also in all floors, complete complying with standard specfication.
Provision for Name board charges
GST Amount for providing service to Government contract works for the above construction works. { GST amount is the Total GST amount for total overall quoted amount above this row in column "BB" for all works in this package}
VM DEEPAK INFRA (BID ID -1403110)
VMD CONSTRUCTION (BID ID -1403790)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_689523.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .