Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.8 LAccepted-AOC 261 3 BESIDE ROYAL HOSPITAL KAMLA NEHRU NAGAR JABALPUR MADHYA PRADESH 482002 | JABALPUR | MADHYA PRADESH | 482002 | 1 | Accepted-AOC BEING L1 | |
| 2 | 2₹8.9 L+₹1.1 L (13.8%)Rejected-Finance A WARD PLOT NO 96 2 T P SCHEME NO 2 SIDDHI APARTMENTS DUDHALI KOLHAPUR 416 012 MAHARASHTRA | KOLHAPUR | MAHARASHTRA | 416012 | 2 | Rejected-Finance Rejected being other than L1 | |
| 3 | 3₹9.0 L+₹1.2 L (14.8%)Rejected-Finance | 3 | Rejected-Finance Rejected being other than L1 | |
| 4 | 4₹9.3 L+₹1.5 L (19.6%)Rejected-Finance | 4 | Rejected-Finance Rejected being other than L1 | |
| 5 | 5₹9.7 L+₹1.9 L (23.9%)Rejected-Finance F 402 AMBIKA APARTMENT PLOT A 9 SECTOR 20 NERUL W NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | 5 | Rejected-Finance Rejected being other than L1 |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
19 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE I CG RATNAGIRI
Military Engineer Services Garrison Engineer I CG Ratnagiri SLUY Shed Plot, W19-23, MIDC Mirjole, Ratnagiri 415 639
PROVN OF ADDITION ALTERATION TO TEMPORARY BUILDING T-1 AT ICGAS RATNAGIRI
2024_MES_675689_1
8215/E8
Open Tender
Civil Works
Item Rate
120 days
RATNAGIRI
As per NIT
8 documents required · 8 mandatory
₹300
GE I CG RATNAGIRI
₹19,000
Yes
7 Dec 2024
21 Sept 2024
21 Oct 2024
21 Sept 2024
19 Oct 2024
5 Oct 2024
Amount
Demolition of cement concrete (unreinforced) in ground floor not exceeding 15cm thickness below or above ground level including floor finishes and removing debris from the site all as specified and as directed.
Dismantling of wall and ceiling boards any thickness including cover fillets at any position and of any description.
M & L for Gypsum ceiling boards,decorative type prepainted of size 600 x 600 x 9 to 9.5mm thick laid over and including grid work of size 600 x 600mm, made out of 0.5mm thick G.I tee 32 x 24 mm for main, 25 x 24mm for cross tee and 20 x 20 mm angle fixed on wall powder coated finish on exposed faces of tee and angle, hung form ceiling using 3 mm thick G.I suspension wires spaced at 1200 mm on main runners including making niches for fans/light complete all as specified & as directed.
M&L 25mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in filling under floor
M&L vitrified ceremic tiles dark shade 10 mm thick (square/rectangular) area of each tiles n exc 0.36 sqm, in floors, set & jointed in neat cement slurry and pointed in coloured cement to match coloured tiles including for Screed bed (or) bedding layer of mortar 15mm thick for laying floor finishes CM (1:6) complete all as specified and directed.
S & F of Powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge.
Providing and fixing Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling,C.P. brass/ stainless steel screws all complete
S&F Door closer hydralulically regulated designation No 3 universal type, suitable for door shutters of 851 to 1000 mm width and weight between 61 to 80 Kg and fixed using aluminium extruded section all as specifieed by Engr-in-charge.
S&F Brass Mortice lock of 4 Levers, vertical type, of size 100mm.
S&F floor door stopper of aluminium alloy body and tongue, anodised with hard drawn steel spring, fixed in floor (Overall length of cover plate 150mm).
S&F Double action floor spring hydraulically regulated made up of minimum 1.25mm thick aluminiumallow sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed all as specified and directed by Engineer in Charge
S&F 100 mm long Butt hinges, extruded aluminum alloy with galvanised mild steel hinge pin, anodised type B-21 all as specified and directed by Engineer in Charge
S&F Aluminum anodised, barrel tower bolts of extruded section and fixed of 200mm long all as specified and directed by Engineer in Charge
S&F Extruded aluminium alloy handles, fabricated type, anodised,150mm long all as specified and directed by Engineer in Charge
S & F of Aluminium composite panel (ACP) AL 33D sheet 3mm panel with 0.3mm aluminium coil thickness aluminium alloy AA3105 for exterior applications sign board fixed on MS/SS/Aluminium frame work by riveting of bolts and nuts at 300mm c/c all along the periphery all as specified and as directed.
S & F12mm thick prelaminated particle board, exterior grade prelaminated both sides with decorative choice laminations fixed with screws to timber frame work/ Aluminium frame work.
S & F of sheet glass 5.5mm thick and glazing with provided with aluminium cleats for securing in squares exc 0.5 sq. m in each pane complete all as specified and as directed.
Taking down carefully copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendents, bell,bell push,regulators, sockets etc removing materials for taking credit and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by Engr-in-charge.(To be measured only when found serviceable in all respects complete for reuse).
Taking down unservicable/partly unservicable street light /light fittings any type, tube light fitting and fixtures, etc, and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes, for reuse at site or carrying to the store complete all as specified and directed by Engr-in-charge. (To be measured only when found serviceable in all respects complete for reuse).
Taking down unservicable/partly unservicable ceiling fan/exhaust fan, sealing cable end, dismantling blades and removing fan and blades to store and making good to the disturbed surfaces of walls/floor etc to macth with existing surfaces including white washing/colour washing/distempering to match with existing wall/floor/ceiling finishes, for reuse at site or carrying to the store complete all as specified and directed by Engr-in-charge. (To be measured only when found serviceable in all respects complete for reuse).
Dismantling serviceable Celing Fan & Refixing of ceiling fan, 1200/1400 mm sweep and connecting up including provision of three core flexible copper wire of size 23/0076 from ceiling rose to ceiling fan complete in all respect all as specified and directed.
Dismantling & Refixing the serviceable LED lights fitting 1x 18W/20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed by Engr-in-charge.
Dismantling & Refixing the LED luminaire 600 mm x 600 mm (2x2), 35/36 watt, 220 V AC recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete with all assoceries intenal prewired & including conecting up with 2 core flexible cppper conductor cable with sutable size complete all as specified and directed by Engr-in-charge.
Point wiring with PVC insulated unsheathed FRLS stranded copper conductor cable of size 1.5 Sq mm, with PVC insulated unsheathed stranded copper conductor cable of size 1.5 Sq mm stranded for earth continuity wire, to be drawn in and including, PVC medium grade conduit not less then 25 mm dia.concealed in walls/roof/floors with MS sheet metal sunken modular switch/Terminal box 1.0 mm thick and Modular plate and brass screws with cup washers complete all as specified and directed by Engr-in-charge. Note : (1) Rate is inclusive of Cutting/chases of wall/floor/ceiling (2) Sub Circuit shall be 2.5 sqmm from D.B to switch Board.
(a) One light point controlled by one, one way switch
(b) One ceiling /exhaust fan point controlled by one switch and regulator
(c) One 3 pin 5 amp socket out point on the same board with other switches.
(d) One3 pin 5 amps socket out let point on independent board
All as per same in item No 7(d) above but for one socket outlet 15/16 Amp on independent board with 2.5 Sq mm cable and 2.5 Sq mm earth wire complete all as specified and directed by Engr-in-charge. ( power point 15/16 Amps sockets) Note : (1) Rate is inclusive of Cutting/chases of wall/floor/ceiling (2) Sub Circuit shall be 4.0 sqmm from D.B to switch Board.
All as per same in item No 8 above but for one socket outlet 20 Amp on independent board with 4.0 Sq mm cable and 4.0 Sq mm earth wire complete all as specified and directed by Engr-in-charge. ( power point 20 Amps sockets) (1) Rate is inclusive of Cutting/chases of wall/floor/ceiling (2) Sub Circuit shall be 4.0 sqmm from D.B to switch Board.
S &F Modular switch 1 way 5A/6A,1 module
S &F Socket, 5A/6A - 2/3 pin combined 2module
S &F Modular switch 1 way 15/16A,1 module
S &F Socket 6A/16A - 2/3 pin combined 2 module
S&F modular white cover plate with frame 3 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F modular white cover plate with frame 8 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F modular white cover plate with frame 12 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F modular white cover plate with frame 18 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F Modular GI Metal flush box 3 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F Modular GI Metal flush box 8 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F Modular GI Metal flush box 12 module Make Legrand, Schneider, hager or equivalent makes specified.
S&F Modular GI Metal flush box 18 module Make Legrand, Schneider, hager or equivalent makes specified.
SHEET METAL ENCLOSURES WITH SOCKET PLUG TOP AND MCBs Double pole 20Amp and neutral enclosure with a two pin and earth plug and socket complete with one Double pole MCB complete all as specified and directed by Engr-in-charge.
S &F Modular Fan regulator 120 Watt 2 module complete all as specified and directed by Engr-in-charge.
Supply and fixing LED luminaire 600 mm x 600 mm (2x2), 35/36 watt, 220 V AC, recessed/surface type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete with all assoceries intenal prewired & including conecting up with 2 core flexible cppper conductor cable with sutable size complete all as specified and directed by Engr-in-charge.
Dismantling & Refixing the Air Conditioning Unit complete with outdoor & Indoor unit with all assoceries intenal prewired & including conecting up with cable of sutable size complete all as specified and directed by Engr-in-charge.
Ideal Infrastructure and Consultants (BID ID -3144478)
m/s Pravin s Bhosale (BID ID -3137431)
SHRIKALP ENGINEERS AND CONTRACTORS (BID ID -3137536)
Advait Enterprises (BID ID -3137523)
ANJALI CONSTRUCTIONS (BID ID -3144522)
LAXMI ENTERPRISES (BID ID -3137483)
K M SUBHANAIAH (BID ID -3143916)
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .