Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
| 5 | Admitted-Finance | Admitted-Finance |
Tender Value
₹41.5 L
EMD Value
₹83,000
Closing Date
7 Apr 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE GOLCONDA
GE GOLCONDA LANGER HOUSE OPP MILITARY HOSPITAL HYDERABAD TELANGANA-08
ADDN/ALTN TO OFFRS MESS BLDG (IBL-15) IN ARTY CENTRE UNDER GE GOLCONDA
2022_MES_511938_1
8556/E8
Open Tender
Civil Works
Item Rate
180 days
HYDERABAD
As Per Tender
9 documents required · 9 mandatory
₹500
GE GOLCONDA
₹83,000
Yes
11 Apr 2022
4 Mar 2022
9 Apr 2022
4 Mar 2022
7 Apr 2022
18 Mar 2022
60 days
Amount
Dismantling Mangalore pattern roofing tiles with ceiling tiles or slate roofing complete all as directed.
Dismantling battens for tiles, shingles etc of any size including tilting fillets n. exc 15 cm centre to centre complete all as specified and directed.
Dismantling of AC sheets/Galvolume sheet/GI sheet of corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings and removing from site complete all as directed.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling of boarding, any description fixed in any position with nails complete all as specified and directed.
M & L pre-painted galvalume aluminium zinc coating GI based corrugated mangalore profile sheet 0.50 mm thick of any colour having tensile strength 550 mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for.
Dismantling timber scantlings 40 Sqcm and over in section in any position in framed work
S & F rolled mild steel in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats of Grade Fe 410 -W (Gde- E- 250) quality- A etc. complete all as specified and directed.
M & L for preparation of new or previously untreated steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Drilling holes round, drill or cut in second class hardwood diameter or side not exc 15 mm dia and complete all as specified and directed.
S & F for mild steel screw bolts of 5 to 10 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt exc. 10 cm. but not exc 15cm complete all as specified and directed.
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6 complete all as specified and directed.
M&L for brickwork with sub class ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1: 4 complete all as specified and directed.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearthed built in CM 1:6 complete all as specified and directed.
M&L for Raised pointing to Squared rubble masonry, uncoursed in cement motar 1:3 complete all as specified and directed.
M&L brick work with fly ash modular bricks built in CM 1:4 straight or curved on plan exc 6 mtr mean radius complete all as specified and directed.
M & L for half brick wall with fly ash bricks straight or curved on plan to any radius built in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster on wall of any description including racking out joints for key scrubbing with water etc. complete all as specified and directed.
M & L for rendering 15mm thick in cement mortor 1:4 (5 mm thick with IWPC @ 3% over a coat of 10 mm thick) on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed. ( Note: IWPC shall be measured and paid separately).
M&L for Rendering 15 mm thick in CM (1:4) on fair faces of brick or concrete surface of walls finished even and smooth without using extra cement complete all as specified and directed
M & L for rendering 10mm thick in cement mortor 1:6 on Brick wall surfaces, finished even and smooth without using extra cement complete all as specified and directed.
M&L Rendering 5 mm thick in CM 1:3 on fair faces of brick surfaces of ceiling finished the surface fair and even including Praparation of newly plastered surfaces and applying Three coats of White wash complete all as specified and directed.
M & L for preparation of new plastered surfaces of walls and applying two coats of exterior grade from asian paint (ACE) or equivalent over a coat of primer comlpete all as specified and directed.
M&L for preparation of newly plastered surfaces wall and applying two coats of oil bound distemper over a coat of chalk whiting primer including 3mm thick wall care putty complete all as specified and directed.
M&L for preparing new plastered surfaces and applying Two coats of cement based paint on surfaces of walls complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of oil bound distemper over a coat of alkali resistant primer on old surface of walls including 3mm thick wall care putty on wall complete all as specified and directed.
M&L for complete removal of existing treatment and applying two coats of cement base paint on walls surfaces complete all as specified and directed.
M&L Preparation of old painted steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of Synthetic enamel paint (Ordinary tint) complete all as specified and directed.
Demolition of Stone slabs and tiles of any description or thickness in floors, plinth Protection, aprons etc Laid, bedded and pointed in any mortar,complete all as specified and as directed.
M&L for Granite 20mm(of any type) work (table rubbed and polished) for wall lining (veneering to wall) 12mm thick in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for Granite 20mm(of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar10 mm thick (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
M&L for Granite 25mm(of any type) work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar10 mm thick (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed.
Demolition of cement concrete (unreinforced) of any description of any position not otherwise specfically provided for as in sunken floors & floor etc and removing debrish from site complete all as directed.
M&L 75mm thick plain cement concrete 1:3:6 Type C2 (using 40mm graded stone aggregate) as in sub base of floors laid in alternative bays including necessary form work complete all as specified and directed
M&L 75mm thick plain cement concrete 1:4:8 Type D-2 (using 40mm graded stone aggregate) as in sub base of floor complete all as specified and directed
M & L for 25 mm thick PCC 1:2:4 Type B1 (using 20 mm graded stone aggregate) sub base/below tiles for levelling of existing surface complete all as specified and directed.
M&L Virified Ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed.
M&L Virified Ceramic tiles dark shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in skirting / dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in CM (1:4) on fair faces of brick brick or concrete surfaces complete all as specified and as directed.
M&L Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed.
M&L Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exceeding 0.42 sqm but not exceeding 1.00 sqm, in skirting / dados etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including 10mm thick backing coat in CM (1:4) on fair faces of brick brick or concrete surfaces complete all as specified and as directed.
M & L for 75 mm thick PCC 1:3:6 type C2 (Using 40 mm graded granite stone aggregate) as in plinth protection finishd even and smooth without using extra cement complete all as specified and directed.
M&L for Machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade laid over and including 50mm thick sand cushioning and the voids shall also be filled with fine sand complete all as specified and directed.
M&L for chequered cement concrete tiles of size 200 x 200x 25 mm thick with mixture of white cement and pigment, machine pressed, set jointed and pointed in neat cement slurry in floors including 15mm thick screed bed or bedding layer in CM (1:6) complete all as specified and as directed.
S & F for 4 mm thick Sheet glass, ordinary quality and glazing with oil putty or wooden beading in squares not exceeding 0.5 Sq. M in each pane complete all as specified and directed.
M&L for Resecuring or easing and adjusting without taking down Shutters of any description exc. 1 sqm and exc. 2 sqm each complete all as specified and directed.
Taking down Chowkats or frames exceeding 1.5 SqM but not exc 4 Sqm each (Without taking off shutters from the frames) complete all as specified and directed.
S&F for Anodised aluminium powder coating of any colour (thickness of powder coating not less than 50 micron) door shutters, aluminium section weighing 0.55 kg/m inlcuding necessary joining cleats, glazing clips, rubber neoprene packing, handles 2 nos in each door, hinges anodised aluminium snap beading screws etc complete all as specified and directed.
S&F Anodised aluminium powder coating of any colour (thickness of powder coating not less than 50 micron) frame for door, windows, vantilators with one or more rebates incl joining cleats and other accessories for fixing complete all as specified and directed.
S & F for Anodised aluminium window and ventilator shutters, side hung type without sash bars, luminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified
S&F pre laminated particle board(12mm thick ) interior grade pre-laminated both side with decorative choice laminations fixed in alluminium door or frame work with screws or necessary fittings complete all as pecified and as directed.
S&F in repair aluminum extrudded section door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg and fixed complete all as specified and as directed.
S&F Brass mortice lock 4 levers, vertical type size 100 mm complete all as specified
S&F of curtain rod 25mm MS decorative type powder coated all as specified in repairs complete all as specified.
S&F of 25 mm dia MS brackets to curtain pipe, decorative type powder coated complete all as specified.
Taking down existing felt, plaster and preparing the surface of roof by cleaning of foreign materials down with water complete all as specified and directed.
M & L for roughening surfaces of old concrete floor or concrete surfaces by picking, sweeping clean and washing down with water to remove dust, etc.and brushing neat cement slurry with 3 Kg of cement per square metre complete all as specified and directed.
M&L for providing cement concrete type B0 1:2:4 (12.5mm graded stone aggregate) as in padding and benching & filletting with IWPC complete all as specified and directed. (Note: IWPC shall be measured and paid seperately)
M & L for 10mm thick screed bed or bedding layer on brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement with IWPC @ 3% as in roof slabs complete all as specified and directed. Note: IWPC shall be measured and paid seperately
M & L for 15mm thick screed bed or bedding layer on brick work or concrete surfaces in CM 1:4 and finished even and smooth without using extra cement with IWPC @ 3% as in roof slabs complete all as specified and directed. Note: IWPC shall be measured and paid seperately
M&L for APP based polymeric membrane minimum weighing 3Kg/Sqm and minimum 3 mm thick reinforced with polyster non wove fabric (weight not less than 150 gms/sqm) laid over primed surface including bituminous primer conforming to IS-3384 applied @ 0.3 ltrs/sqm by forced application and applying one coat bitumen grade 85/25 @ 1.2 Kg/Sqm over finished with one coat of aluminium paint @ 100 ml/sqm, 10 cm overlap fused uniformly by LPG torch flame complete all as specified and directed. Note No.01 :-Rate included taking down and refixing of earth strips or any other in the same position.
Supply only integral water proofing compound.
S & F Mild steel work framed work as in guards bars, grills, barred iron doors, framed and hung gates, including pintle hinges, stops, hand made sliding bolts etc. and similar work confirming to Fe 290 Gde - E - 165 complete all as pecified and as directed.
S & F in repairs stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.4 mm and fixed with wooden beeds complete all as specified and directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards slabs/ blankets any thickness including cover fillets all as specified and as directed.
S & F true or horizontal level 600mmx600mm panels, false ceiling, hot dipped galavnised steel sections exposed suface with precoated capping, main tee of size 24x32mm at every 1200mm c/c and cross tee of size 24x27mm (1200mm & 600mm long) at every 600mm c/c and wall angle of size 19x19mm fixed to perimetere wall, as per manufacturer's instructions, grid to be suspended at every 1200mm c/c in both directions by using 3mm dia pre-straightened GI wire at every 1200mm internal at the main tee, including 9mm thick gypsum board of size 600mm X 600mm with rear size aluminium foil and front side PVC lamination, complete all as specified and directed.
Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in hard/dense soil complete all as specified and directed.
Excavation in trenches n.exc 1.50m wide and n. exc 1.50m in depth and getting out in hard rock by means of mechanical plant or by chisel cutting complete all as specified and directed.
Returnng, filling in including spreading, levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed.
Spreading & Levelling and well ramming including watering as required in layers n.exc 25 cm thick complete all as specified and directed.
Removing excavated material n exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed.
M&L for Treating the backfill in contact with foundation at the rate of 7.5 litres of emulsion per square metre of vertical surface complete all as specified and directed (Area of the sub structure in contact with backfill to be measured)
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square metre of surface complete all as specified and directed
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square metre of surface area complete all as specified and directed
M&L for PCC type D2 1:4:8 (40mm graded Aggr) in foundations, filling and mass Concrete complete all as specified and directed
M&L for use & waste of rough finished flat Form work to sides of concrete foundations rafts, footing, base of columns, raft and raft beams, sides & soffits of foundation (if any) of foundation and plinth beams and similar work complete all as specified and directed.
M & L for reinforced Cement Concrete (Nominal mix) type B1 1:2:4 (using 20 mm graded granite stone aggregate) in foundations including rafts, footings and mass concrete, foundation beams, plinth beams, bases for columns, basement slabs etc complete all as specified and directed.
M&L for use and waste of form work to sides and soffits of floor or roof beams, lintles, cantlevers, shelves incl supports etc for rough finished surface of concrete complete all as specified and directed.
M&L for reinforced cement concrete (Nominal mix) type B1 1:2:4 (20 mm graded aggregate) in lintel bands, roof beams and cantilevers etc complete all as specified and directed.
Use & waste of rough finished Square, rectangular or polygonal Form work to sides of pillars, posts, struts, columns and stanchions complete all as specified and directed.
M & L for reinforced Cement Concrete (Nominal mix) type B1 1:2:4 (using 20 mm graded granite stone aggregate) in Columns, piers, posts and struts complete all as specified and directed.
M&L for form work to chullah hoods,chajjas troughs and similor items including edges complete all as specified and directed.
M&L for reinforced Cement Concrete type B11:2:4 (20 mm graded aggregate) nominal mix for Chajjas complete all as specified and directed.
M&L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) rough finished surface complete all as specified and directed.
M&L for formwork to edges of concrete flats, treads, breaks in floors,window cills, concrete railings,openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide rough finished surfaces complete all as specified and directed.
M&L for reinforced Cement Concrete 1:2:4 20 mm graded aggregate nominal mix for slabs supported on walls, beams and columns in floors, roofs, landings balconies canopies, desk slabs and in shelves and the like complete all as specified and directed.
Material and labour for mild steel TMT bars, 10mm dia and over,as in reinforcement, cut to length bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips quality complete all as specified and direceted.
All as per Item No 91 here-in-before but mild steel TMT bars, 6 mm to 8 mm dia ditto-
All as per Item No 91 here-in-before but 5mm dia and over upto and including 10 mm dia in stirrups, spaces and binders Ditto-
M&L hardcore of gauge n.exc 63mm of broken stone or boulders, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed.
S&F double action floor spring hudraulically regulated made up of minimum 1.25mm thick aluminium alloy sheet foundation box, main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty complete all as specified and directed.
S&F for 4.00mm thick Figured glass pin headed quality in squre n.exc. 0.5 Sqm in each pane complete all as specified and directed.
S&F 0.63 mm nominal dia of wire ; galvanised mild steel wire cloth and average width of aparture 1.40 mm and fixed with tinned tacks or galvanised wire stapple complete all as specified and directed.
S&F 12mm thick tinted glass shelve/sliding shutter including 250mm long stainless steel handle 02 nos, locking arrangements, and necessary fitting complete all as specified and directed.
M&L for providing, cement concrete 1:3:6 Type C1 using 20 mm graded aggregate in, coping complete all as specified and directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cum, getting out in Hard/ Dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil complete all as specified and directed.
M&L for plain Cement Concrete Type B1 1:2:4 (using 20 mm graded stone aggregate) in foundation filling, mass concrete and similar works and for MS Pipe fixing complete all as specified and directed.
S&F for Steel work in tubular trusses & vertical post including special shaped washer etc complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade st-240 complete all as specified and directed.
S&F MS Plain plates, square cut, with riveted, bolted or welded attachment Fe-410-W (Gde-E-250) quality A complete all as specified and directed.
M&L for 15 mm bore GI Tubing medium grade with all fittings fixed to wall/ ceiling/ in floor complete all as specified and directed.
M&L for 20 mm bore GI Tubing medium grade with all fittings fixed to wall/ ceiling/ in floor complete all as specified and directed.
S&F for rotational moulded polyethylene water storage tanks (multi-layar) (cylindrical vertical with closed top) of 1000 ltrs capacity hoisted and fixed in position complete all as specified and directed.
S&F of ball valves high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe and fixed to 25mm bore pipe complete all as specified and directed.
S&F for 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
Taking down carefully existing point wiring of any description for (light, fan, sockets bells etc) complete including fittings such as sunken boxes, switches, sockets, ceiling rose, lamp holders, brackets, fittings, pendants, fan regulartors etc and making good the disturbed surface of walls, floors etc complete all as specified and directed.
Taking down existing sub main wiring /Service wire of any description and size including earth wire, batten, conduits and making good the disturbed surfaces of walls, floors etc complete all as specified and directed.
M&L for Point wiring for one light point/fan point/bell point controlled by one switch with 1.5 sq. mm (nominal area) single core PVC insulated FRLS sheathed multi-stranded copper conductor cable (maintaining colour code), 1100 volts grade in and including non metalic rigid PVC conduit with appropriate size with all fittings (ISI Marked) suitable surface wiring on stone/brick, masonary walls, roof etc including modular sunken box of adequate size with suitable modular plate cover for mounting modular switches, sockets, regulators, light fittings etc. complete with all fittings and accessories fixed to wall/ ceiling for one light/ fan /bell point controlled by one oneway modular switches including one run 1.5 sqmm (nominal area) PVC insulated FRLS unsheathed multi-stranded copper conductor cable green in colour for earth continuity conductor connected to common earth dolly including cutting/running chases, pinning in and making good the disturbed surfaces to match with the existing specification, complete all as specified & directed.
All as per Item No.112 above but one 5 Amps 3/5 pin modular socket outlet on independent board complete all as specified and as directed.
All as per Item No.112 above but for one 3/5 pin 5/6 Amps modular socket outlet point on same board with other switches complete all as specified and as directed.
All as per item no:3 but for One 3 pin 15 / 16 Amps modular switch socket outlet point on independent board with 2.5 sqmm PVC (FRLS) insulated sheathed copper conductor single core multi stand flexible cable and 2.5 sqmm PVC (FRLS) insulated sheathed copper conductor single core cable (green colour) as earth lead complete all as specified and directed.
M&L lamp holder insulated body with back plate suitable for battern fittings complete all as specified and directed.
S&F Ceiling rose surface bakelite 65 x 50 mm 2/3 terminals complete all as specified and directed.
S&F Modular switch, single pole, one way, 6 Amps one module complete all as specified and as directed.
S&F Modular 6A 3 pin universal socket outlet, 2 module complete all as specified and as directed.
S&F Modular switch, single pole, one way, 16 Amps one module complete all as specified and as directed.
S&F Modular socket outlet 2-in-1, 6/16 Amps, 2 module complete all as specified and as directed.
S&F modular stepped type electronic fan regulator 220 volts, 100Watt complete all as specified and as directed.
S & F Ceiling fans, complete with three blade, down rod, accessories 230V, 1200mm sweep, with Squirrel cage induction motor complete all as specified and as directed.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, 240 volts complete all as specified and as directed.
S&F 9 W LED bulb of base B22 with color temp 6500K all as specified and directed.
Supply and fixing LED luminaire 7.5 watt, 230 V AC wall Mounted with glass diffuser including connecting up with three core flexible copper conductor cases of suitable size and 7.5 watt led E27 warm white bulb complete all as specified and directed.
S&F Wall mounted indoor decorative 20W LED 6000K (4 ft.), extruded aluminium batten in anodised finish with opal diffuser, IP20 heat sink provided for efficient heat dissipation and integrated electronic driver, lamp color white complete set including necessary connection with twin twisted unsheathed PVC copper cable of suitable size complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing LED luminaire 2x2 panel light, 24 watt, 230 V AC recessed type with high efficiency PMMA diffuser suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing LED luminaire 18 watt, 230 V AC recessed / Surface type with high efficiency PMMA diffuser suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
S&F Sheet metal enclosure MCB distribution board including 200 Amps bus-bar single pole and neutral 240V, 8 Ways, double door including taking down of existing sheet metal enclosure complete all as specified and directed.
All as per item No. 131 above but TPN 4 way, 415 V complete all as specified and directed.
S&F MCB SPN, 240V, 10KA 'C' curve, 32 Amps.
S&F MCB SP, 240V, 10KA 'C' curve, 5 to 32 Amps.
S&F MCB TPN, 415V, 10KA 'C' curve, 40 to 100 Amps.
M&L Submain wiring with two single core PVC (FRLS) insulated flexible copper conductor cable of size 6 Sqmm and one single core PVC (FRLS) insulated unsheathed flexible copper conductor cable green colour of size 4.0 Sqmm as earth lead in and including PVC conduit medium grade with all fittings suitable for concealed type and making good the disturbed wall surfaces to match with existing specification all as required at site complete with all as specified and directed.
All as per item No. 136 above but Sub main wiring using two runs of 2.5 Sqmm wire with 2.5 Sqmm earth wire complete all as specified and directed
All as per item No. 136 above but Sub main wiring using two runs of 1.5 Sqmm wire with 1.5 Sqmm earth wire complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25.0 sq mm 4 core complete all as specified and directed
Supply and spread approved dry river sand / M sand for cushioning of cable laid in trenches including watering and consolidation, complete all as specified and directed. Note:- Punned thickness of sand cushioning shall measured and paid.
M&L brick protection with common burnt bricks sub class ‘B’ for cable protection complete all as specified and directed.
S & L GI tubing , light grade, with all fittings for cable protection at road crossing / on poles and tubing sealed at both ends after laying the cables complete all as specified and directed of size 40 mm bore complete all as specified and directed
Material & Labour for shifting of LT Panel (Approx.size 1 M x 0.3 M x 0.8 M) including removing the existing incoming and out going cables and reconnecting cables with necessary lugs, glands nuts, bolts etc and PCC foundation of suitable size complete all as specified and directed
M&L bands, straps, supports or stays for rain water, ventilating pipes including bolts if required hooks (stay) heavy for large gates, hook and pintle hinges, large hasps and staples, chains, hand made slidings bolts clamps hold fasts, wall ties hook for hanging fans, plain angles cleats for securing purlins to wood trusses or rafters, knee piece inserts two way and three way straps plate washers and similar small articles conforming to Fe 290 Gde E-165, including clamps nuts, bold, fixing and old one complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less 1.5 mtrs below normal ground level connected to galvanised earth lead wire 4 mm dia by means of bolts nuts, check nuts and washers of galvanized iron of steel all as shown in electrical plate No.3 connected to earthing test point incl necessary earth work, excavation, PCC 1:3:6 type CI using 20mm graded stone aggregate for earth chamber, provn of PCC cover 40 mm thick 1:2:4 mm type B1, funnel with water Pipe, GI pipe 15mm dia medium grade as protection pipe, GI earth lead complete all as specified and directed.
SANJEEV CONSTRUCTIONS
m/s s indra reddy constructions
M/S Veerabhadra Constructions
Sumpoorthy Engineers
SWAMY AYYAPPA CONSTRUCTIONS
NAVANAND ENTERPRISES
BUILDWEL
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .