| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 CrAccepted-AOC 244 22 ONKAR NAGAR B TRI NAGAR TRI NAGAR NEW DELHI 110035 NORTH WEST DELHI DELHI 110035 INDIA | NORTH WEST DELHI | DELHI | 110035 | ₹7.4 Cr Quoted ₹7.5 Cr | L1 | Accepted-AOC Being lowest tender |
| 2 | L2₹7.8 Cr+₹30.5 L (4.07%)Rejected-Finance 3A RAM MOHAN MULICK GARDEN LANE UNIT NO 6A 3RD FLOOR KOLKATA 700010 | KOLKATA | WEST BENGAL | 700010 | ₹7.8 Cr+₹30.5 L (4.07%) | L2 | Rejected-Finance Higher than lowest tender |
| 3 | L3₹8.4 Cr+₹91.5 L (12.2%)Rejected-Finance 183 MG ROAD JUNGLIGHAT PORT BLAIR 744103 | PORT BLAIR | SOUTH ANDAMANS | ANDAMAN NICOBAR ISLANDS | 744103 | ₹8.4 Cr+₹91.5 L (12.2%) | L3 | Rejected-Finance Higher than lowest tender |
| 4 | L4₹9.9 Cr+₹2.4 Cr (32.5%)Rejected-Finance | ₹9.9 Cr+₹2.4 Cr (32.5%) | L4 | Rejected-Finance Higher than lowest tender |
| 5 | Rejected-Technical | - | - | Rejected-Technical Work experience more than 5 years. Annual turnover and solvency certificate not submitted. Hence rejected. |
Tender Value
Refer Docs
EMD Value
₹8.3 L
Closing Date
6 Sept 2023, 6:00 pmClosed
BRIG SUSHIL KUMAR CHIEF ENGINEER
HQ CHIEF ENGINEER KOLKATA ZONE MILITARY ENGINEER SERVICES BALLYGUNGE MAIDAN CAMP GURUSADAY ROAD KOLKATA 700019
ADDN ALTN AND SPL REPAIRS TO OFFR MD ACCN UNDER GE ALIPORE KOLKATA
2023_MES_609752_1
89078/E8
Open Tender
Civil Works - Buildings
Works
360 days
KOLKATA
Please refer Tender documents.
8 documents required · 8 mandatory
₹3,000
Yes
GE ALIPORE KOLKATA
₹8.3 L
Yes
3 Nov 2023
19 Jul 2023
13 Sept 2023
19 Jul 2023
6 Sept 2023
23 Aug 2023
Amount
Taking down cement plaster including raking out joints, hacking for key, scrubbing down with water etc complete.(upto 04 storey High of building)
All as per item No 1 but 5 storey to 8 storey
All as per item No 1 but 9 storey to 12 storey
Demolition of Brickwork quoins,arches,pillars etc but excluding ashlar facings,dressed all store work and precast concrete articles built in cement mortar.(upto 04 storey High of building)
All as per item No 4 but 5 storey to 8 storey
All as per item No 4 but 9 storey to 12 storey
M&L for brick work with sub class 'B' bricks built in cement mortar 1:6 straight or curved on plan exceeding 6 mtr mean radius and all as directed.(upto 04 storey High of building)
All as per item No 7 but 5 storey to 8 storey
All as per item No 7 but 9 storey to 12 storey
M&L for Brickwork with sub-class `B’ bricks, straight or curved on plan to any radius in half brick thick walls built in CM (1:4) .(upto 04 storey High of building)
All as per item No 10 but 5 storey to 8 storey
All as per item No 10 but 9 storey to 12 storey
Demolition of RCC (reinforcement) of any description and in any position not otherwise specifically provided for .(upto 04 storey High of building)
All as per item No 13 but 5 storey to 8 storey
All as per item No 13 but 9 storey to 12 storey
Use and waste of formwork to sides of column, pillars, posts, stanchions for rough foinished surface complete all as specified and as directed by the Engr-in-Charge.(upto 04 storey of building)
All as per item No 16 but 5 storey to 8 storey
All as per item No 16 but 9 storey to 12 storey
Use and waste of formwork to sides and soffit of beams, lintels, cantilevers, shelves etc for rough finished surface complete all as specified and as directed by the Engr-in-Charge. .(upto 04 storey high of building)
All as per item No 19 but 5 storey to 8 storey
All as per item No 19 but 9 storey to 12 storey
Use and waste of formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railing horizontal or sloping and similar work exe 5 cm but not exe 10 cm thick completeall as specified and as directed by the Engr-in-Charge. .(upto 04 storey High of building)
All as per item No 22 but 5 storey to 8 storey
All as per item No 22 but 9 storey to 12 storey
Use and waste of formwork to chullah hoods, chajjas, troughs, parapets and similar items including edges for rough finished surface complete all as specified and as directed by the Engr-in-Charge. .(upto 04 storey of building)
All as per item No 25 but 5 storey to 8 storey
All as per item No 25 but 9 storey to 12 storey
M&L for RCC for M 25 (Design Mix) using 20 mm graded crushed stone aggregate as in parapets, balcony and similar work all as specified and directed (upto 04 storey high building)
All as per item No 28 but 5 storey to 8 storey
All as per item No 28 but 9 storey to 12 storey
Chipping of unsound /weak concrete materials from slabs , beams,columns ,lintel,chajja, fin , facia etc. by any means as directed by engr-in-charge including tapering all edges, making square shoulders of cavities air or sand blasting etc and cleaning of exposed concrete surface of lightly picking materials by air blasting or sand blasting incl foreign matrials , loose concrete/aggregate etc and disposal of all debris out of MOD land and complete all as specified and as directed by Engr-in-Charge ( upto 4 storey of building) for 25mm average thickness for slabs/Chajja
All as per item No 31 but 5 storey to 8 storey
All as per item No 31 but 9 storey to 12 storey
All as per Item No 31 but 50 mm average thickness for beams/Lintel (upto 4 storey of building)
All as per item No 34 but 5 storey to 8 storey
All as per item No 34 but 9 storey to 12 storey
All as per Item No 31 but 60 mm average thickness for Column( upto 4 storey of building)
All as per item No 37 but 5 storey to 8 storey
All as per item No 37 but 9 storey to 12 storey
All as per item No 31 but add or deduct for every 10 mm thickness extra ( upto 4 storey of building)
All as per item No 40 but 5 storey to 8 storey
All as per item No 40 but 9 storey to 12 storey
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap)by manual methods (using wire brushing ,chiselling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area throughly by water and allow it to dry all as per manufacturer,s instruction to give it a totally rust free finished steel surface complete all as specified and directed by Engr-in-charge upto 12 mm dia bar (upto 4 storey of building)
All as per item No 43 but 5 storey to 8 storey
All as per item No 43 but 9 storey to 12 storey
Removing of concrete all around reinforcement including from behind the reinforcing bars to give an average 25mm (but not less than 15mm clear air gap)by manual methods (using wire brushing ,chiseling etc) and applying alkaline rust removing chemical followed by removing rust including from behind the reinforcing bars by emery paper and cleaning the area thoroughly by water and allow it to dry all as per manufacturers instruction to give it a totally rust free finished steel surface complete all as specified and directed by Engr-in-charge (Make : SIKA/FOSROC) above 12 mm dia bar (upto 4 storey of building) Make Sika/Hindcon/Fosroc or its equivalent
All as per item No 46 but 5 storey to 8 storey
All as per item No 46 but 9 storey to 12 storey
M & L for providing single coat of epoxy bond adhesive of prepared non metallic surface (existing surface) and applying by brush all as per manufactures instruction/specification. The bonding agent shall have minimum compressive strength of 40 N/Sqmm and complete all as specified and directed by Engr-in-charge (upto 4 storey of building)
All as per item No 49 but 5 storey to 8 storey
All as per item No 49 but 9 storey to 12 storey
Supply and application of Epoxy Zinc rich primer on the prepared steel surface by brush the primer shall have a minimium specific gravity 1.75 minimum weight film thickness/coat 40 microns and minimum adhesive bond strength with steel is 1.5N/mm2 complete all as specified and directed by Engr-in-charge (upti 04 storey building)
All as per item No 52 but 5 storey to 8 storey
All as per item No 52 but 9 storey to12 storey
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling,fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. upto 12 mm dia bar upto 4 storey High.
All as per item No 55 but 5 storey to 8 storey
All as per item No 55 but 9 storey to 12 storey
M & L for introducing new reinforcement bars for structural connection in RCC beams, columns, lintel and slabs including power drilling holes of appropriate diameters in reinforced or plain cement concrete to a minimum depth of 150mm and upto 200mm including power drilling, fixing the reinforcement in position using epoxy, cleaning of loose dust by blowing air, sealing with epoxy cartridges etc all as specified and directed by Engr-in-charge. Above 12 mm dia bar upto 4 storey High.
All as per item No 58 but 5 storey to 8 storey
All as per item No 58 but 9 storey to 12 storey
M & L for providing and inserting mild steel shear key bars/levelling gauges of required length and diameter in reinforced/plain concrete as per drawing and direction of engr-in-charge including power drilling holes of appropriate diameters to a minimum depth equal to 12 times the diameters of shear key bar/levelling gauge, cleaning the drilled holes of loose dust by blowing , insertion of epoxy from cartridge, placing the shear key bar in position and allowing it to stay undisturbed for 24 hours. Rate shall be include cost of labour, all materials, T&P for power drilling in concrete , epoxy cartridge, plastic nozzle etc, complete incl cleaning the drilled holes of loose dust by blowing air complete all as spd and dir by Engr-in-charge. 12 mm dia, 300mm long @ MS shear key of bar . The projection length of shear key shall be more than 10 times its diameter plus half of the thickness of cover to concrete plus bend length.( upto 4 storey High).
All as per item No 61 but 5 storey to 8 storey
All as per item No 61 but 9 storey to 12 storey
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected column etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as spd and dir by Engr-in-charge. 60 mm average thickness of Column,upto 4 storey High. Make Sika/Hindcon/Fosroc or its equivalent
All as per item No 64 but 5 storey to 8 storey
All as per item No 64 but 9 storey to 12 storey
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as spd and dir by Engr-in-charge 50 mm average thickness of Beam, upto 4 storey High.
All as per item No 67 but 5 storey to 8 storey
All as per item No 67 but 9 storey to 12 storey
M & L for providing and placing in position free flow non shrink cementitious micro concrete of Grade of M-50 to the effected beam, column etc . The micro concrete shall have a minimium 1 day compressive strength of 10 Mpa and 28 days strength of 50 Mpa, minium tensile strength 5N/mm2 @ 28 days, minimium flextural strength 5N/mm2 @ 28days and complete all as spd and dir by Engr-in-charge. Add or deduct for every 10 mm thickness extra, upto 4 storey High.
All as per item No 70 but 5 storey to 8 storey
All as per item No 70 but 9 storey to12 storey
Supply, mixing and application two component structural grade polymer modified reinstatement morter, where local spalling has taken place or shuttering is not possible . The morter can be applying in layers not exceeding 6mm thick in each layer in and upto any thickness in smaller vertical pockets and upto any thickness in horizontal applications. The mortar should have a minimium compressive strength 12N/mm2 in 1 day and 45N/mm2 in 28 days. Minimum flexural strength should be 8 N/mm2 in 28 days. A modified styrene butadience emulsion for use as a bonding aid and gauging liquid for cementious system to be mixed with cement slurry before the application of modified polymer mortar to be used @ 6 ltr/bag of cement. The bonding agent should have minimium compressive strength 24N/mm2. Minimum tensile strength 3.5N/mm2, minimium flexural strength 6.5N/mm2 complete all as spd and directed by the Engr-in-charge upto 25 mm average thickness and upto 4 storey High NOTE:- Cement and sand morter in proportion of 1:2 graded coarse sand ) with polymer admixed in proportions approved by Engr-in-charge.
All as per item No 73 but 5 storey to 8 storey
All as per item No 73 but 9 storey to 12 storey
M & L for applying curing compound over concrete surfaces as per manufactures instruction complete all as spd and dir by Engr-in-charge upto 4 storey high.
All as per item No 76 but 5 storey to 8 storey
All as per item No 76 but 9 storey to 12 storey
Providing of double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly alignede for the functional aspect and safe of the building upto and including 15m hieght complete all as specified and as directed.
Providing of double layer self supporting steel scafolding to external perimeter of building duly cross braced and properly alignede for the functional aspect and safe of the building exceeding 15m height but not exceeding 45m height complete all as specified and as directed.
Materials and labour for providing and inserting 12mm dia aluminium/ GI injection nipples along crack line honey combed area including drilling holes as required diameters upto depths from 40mm to 80mm or half the thickness of member (whichever is less) at required spacing as approved by GE for the concrete work surface upto 12 storied building complete all as specified and as directed.
Materials and labour for making grooves of size 12mmx12mm along the crack line, making the crack dust free by blowing compressed air and then washing with water, finnaly sealing the distance between the injection nipple with approved putty (polymer modified cement mortar/polyster putty) etc. and allow to cure. If cementitous grout the materail proposed to be used, washing and saturating the cracked surface with water by pumping from top most nipple and down wards and curing of putty upto 12 storied building complete all as specified and as directed.
Supply and applying two coats of High performance elastomeric cementitious waterproof coating sandwiched with 45 GSM glass fibre reinforcement on the entire floor and 1.0 m of all walls of all toilets as per following methodology:- Cleaning of exposed concrete surface by mechanical means or by hydro blasting to remove laitance, loose particles, contamination etc. which may hinder bonding. Coving of RCC joints with PCC (1:1.5:3) mixed with Integral Water Proofing compound. Applying one coat of Waterproofing membrane to concrete surfaces followed by application of 45GSM glass fibre on the wet surface. Applying second coat of waterproofing membrane at the right angles to the direction of first coat. Second coat shall be applied after the first coat gets dry. Sprinkling fine aggregate immediately after the application of second coat to get the mechanical key for protective plaster. Curing to Water proofing membrane to be carried out for minimum period of 3 days with ponding complete. The Water Proofing Product Should have Mixed density: 1.68g/cc (brushable consistency). Adhesion to concrete : >1N/mm2. Static crack accommodation: 1mm (upto 04 storey high building)
All as per item No 83 but 5 storey to 8 storey
All as per item No 83 but 9 storey to 12 storey
S&F shear connector of 8mm dia & requisite length on the surface to be repaired for the bonding between old and new concrete as per the locations instructed by the Engr-in-Charge. The shear connectors shall be of L shape and welded with existing reinforcement at least 100mm in length @ 200mm c/c both horizontally and vertically followed by coat of epoxy Zinc primer as per the specification mentioned in complete all as specified and as directed. ( upto 04 Storey ht of Bldg)
All as per item No 86 but 5 storey to 8 storey
All as per item No 86 but 9 storey to 12 storey
S&F TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips (upto 04 storey High of building)
All as per item No 89 but 5 storey to 8 storey
All as per item No 89 but 9 storey to 12 storey
S&F TMT bars 8 mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips .(upto 04 storey High of building)
All as per item No 92 but 5 storey to 8 storey
All as per item No 92 but 9 storey to 12 storey
S&F TMT bars 8 mm dia and over as in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips .(upto 04 storey High of building)
All as per item No 95 but 5 storey to 8 storey
All as per item No 95 but 9 storey to 12 storey
Demolition of cement concrete of any description and in any position not other wise specifically provided for complete all as specified and as directed. (upto 04 storey High of building)
All as per item No 98 but 5 storey to 8 storey
All as per item No 98 but 9 storey to 12 storey
M&L for Rendering 15mm thick in CM (1:6) on other than fair face of brick work or concrete surfaces and finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
All as per item No 101 but 5 storey to 8 storey
All as per item No 101 but 9 storey to 12 storey
M&L for Rendering 20mm thick in two layers (Top 10mm thick rendering coat mixed with water proofing compound applied as per manufacturers instructions shall be laid over 10mm thcik plastered surface) with CM (1:4) on fare faces of brick work or concrete surfaces finished the surface even and smooth without using extra cement complete all as specified and as directed by Engineer-in-charge.. .(upto 04 storey High of building) Note: WPC shall be measured and paid separately
All as per item No 104 but 5 storey to 8 storey
All as per item No 104 but 9 storey to 12 storey
M&L for Rendering 5mm thick with CM (1:3) on or concrete surfaces and finished the surface even and smooth as in ceiling complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
All as per item No107 but 5 storey to 8 storey
All as per item No 107 but 9 storey to12 storey
Material and labour for preparation of new wall or previously untreated surfaces and one coat alkali resistant primer, sanding the surfaces and Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives 1.43 litre/ 10 sqm over upto four storied building complete all as specified and as directed.
All as per item No 110 but 5 storey to 8 storey
All as per item No 110 but 9 storey to 12 storey
Material and labour for complete removal of existing old surfaces of wall and preparation of old or previously untreated surfaces and one coat alkali resistant primer, sanding the surfaces and Material & Labour for applying Two or more coatsof 100% Premium acrylic emulsion painthaving VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade Company Depot Tinted) with silicon additives 1.43 litre/ 10 sqm over upto 04 storied building complete all as specified and as directed.
All as per item No 113 but 5 storey to 8 storey
All as per item No 113 but 9 storey to 12 storey
M/L preparation of new plastered surface and applying three coats of white wash on ceiling complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
All as per item No 116 but 5 storey to 8 storey
All as per item No 116 but 9 storey to 12 storey
M/L preparation of old surface and applying one coats of white wash on ceiling to match with the new one complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
All as per item No 119 but 5 storey to 8 storey
All as per item No 119 but 9 storey to 12 storey
M/L preparation of new plastered surface and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
All as per item No 122 but 5 storey to 8 storey
All as per item No 122 but 9 storey to 12 storey
M/L preparation of old decorated surface by complete removal of existing treatment, washing, rubbing, stopping etc and applying two coat of oil emulsion distemper over a coat of primer to match with the new suface on wall. complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building).
All as per item No 125 but 5 storey to 8 storey
All as per item No 125 but 9 storey to 12 storey
Supply only Integral Liquid water proofing compound (ISI Mark).
Dismantiling of floor hearth or wall tiling incl cement mortar (but not backing), and rubbish off the premises (out of MOD land), complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
All as per item No 129 but 5 storey to 8 storey
All as per item No 129 but 9 storey to 12 storey
M&L for light shade double charged vitrified tiles 7 to 8 mm thick (square /rectangular) area of each tiles exceeding not exc 0.36 Sqm , in floor etc. set and jointed in neet cement slurry and pointed white or coloured cement to match the light shade of the tiles, over and including Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and as directed by Engineer-in-charge .(upto 4 storey of building)
all as item No 132 but from 5 storey to 8 storey of building
all as item No 132 but from 9 storey to 12 storey of building
all as item No 132 but as in skirting over and including backing coat/Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:4) as in dado/skirting complete all as specified and as directed by Engineer-in-charge. (upto 4 storey of building)
All as item No 135 but from 5 storey to 8 storey of building
All as item No 135 but from 9 storey to 12 storey of building
Roughening of surface of old concrete floor by picking , sweeping clean and washing down with water to remove dust etc complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building)
All as per item No 138 but 5 storey to 8 storey
All as per item above but 9 storey to 12 storey
Non - skid Ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but n.exc 0.18 sqm infloors etc. set and jointed in neat cement slurry andpointed in white or colouredcement to match the shade of tiles over and including Screed bed or bedding layer 15 mm thick in cement mortar (1:6) for laying floor finishes complete all as specified and as directed by Engineer-in-charge .(upto 04 storey High of building)
All as per item No 141 but 5 storey to 8 storey
All as per item No 141 but 9 storey to 12 storey
All as item No 141 but as in skirting over and including backing coat/Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:4) as in dado/skirting complete all as specified and as directed by Engineer-in-charge. (upto 4 storey of building)
All as item No 144 but from 5 storey to 8 storey of building
All as item No 144 but from 9 storey to 12 storey of building
Glazed ceramic tiles in vertical surface 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match the shade of tiles .complete all as specified and as directed by Engineer-in-charge. (Note:- Screed bed shall be measured and paid Seperately under respective items of Sch "A') (upto 04 storey High of building)
All as per item No 147 but 5 storey to 8 storey
All as per item No 147 but 9 storey to 12 storey
Backing coat/Screed bed or bedding layer of mortar 10 mm thick in cement mortar (1:4) as in dado/skirting complete all as specified and as directed by Engineer-in-charge. (upto 4 storey of building)
All as per item No 150 but 5 storey to 8 storey
All as per item No 150 but 9 storey to 12 storey
M&L for 18 to 20 mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window- cills, cooking platforms and like over and including 15mm thick cement mortar bedding (1:6) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling complete all as specified. (upto 04 storey High of building)
All as per item No 153 but 5 storey to 8 storey
All as per item No 153 but 9 storey to 12 storey
Rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed by Engr-in-Charge.(upto 04 storey High of building)
All as per item No 156 but 5 storey to 8 storey
All as per item No 157 but 9 storey to 12 storey
Taking up or down 15mm steel tubing and connections, including cleaning for removal.(upto 12 storey High of building)
S&F CPVC pipes 20 mm outer diameter of SDR 11 & plain CPVC SDR 11 including necessary brass fittings and fixers to conect/receive GI pipes/brass taps as in walls, ceiling, floor, etc. complete all as specified.(upto 12 storey High of building)
Taking up or down 20mm steel tubing and connections, including cleaning for re-fixing or removal.(upto 12 storey High of building)
S&F CPVC pipes 25 mm outer diameter of SDR 11 & plain CPVC SDR 11ncluding necessary brass fittings and fixers to conect/receive GI pipes/brass taps as in walls, ceiling, floor, etc. complete all as specified.(upto 12 storey High of building)
S&F 25 mm bore gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipes complete all as specified and as directed by Engineer-in-Charge.(upto 12 height of building)
S&F in repair 15mm bore Brass CP bib cock fancy type with qtr turn or half turn chromium plated with crutch or butterfly handle, screwed down, screwed for iron pip or for brass ferrule and complete all as specified and as directed by Engineer-in-Charge.(upto 04 storey High of building)
All as per item No 164 but 5 storey to 8 storey
All as per item No 165 but 9 storey to 12 storey
S&F in repair 15mm bore Brass CP angular stop cock type with crutch or butterfly handle complete all as specified and as directed by Engineer-in-Charge.(upto 04 storey High of building)
All as per item No 167 but 5 storey to 8 storey
All as per item No 167 but 9 storey to 12 storey
S&F in repair PVC connection 15 mm size pipe with PTMT nut of Length 600 mm complete all as specified and as directed by Engineer-in-Charge.(upto 04 storey High of building)
All as per item No 170 but 5 storey to 8 storey
All as per item No 170 but 9 storey to 12 storey
S&F in repair brass CP shower roses with or without swivel joints,with shower arm, 125mm size, including fixing to steel pipes or union complete all as specified and as directed by Engineer-in-Charge.(upto 04 storey High of building)
All as per item No 173 but 5 storey to 8 storey
All as per item No 173 but 9 storey to 12 storey
S&F in repairs Vitreous China wash basin ( white), flat back, size 580 x 450 mm, excluding taps, waste,chain and plug and porcelain stopper but including brackets, complete all as specified and as directed by Engineer-in-Charge.(upto 04 storey High of building)
All as per item No 176 but 5 storey to 8 storey
All as per item No 176 but 9 storey to 12 storey
All as per item No 179 but 5 storey to 8 storey
All as per item No 179 but 9 storey to 12 storey
Supplying and laying of CPVC pipes 40 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings in wall complete all as specified. complete all as specified and as directed by engineer-in-charge. (upto 04 storey High of building).
All as per item No 182 but 5 storey to 8 storey
All as per item No 182 but 9 storey to 12 storey
S&F 32 mm bore waste fittings, brass, chromium plated for glazed ware sinks, basins, etc. with long screwed shanks and fly-nuts, flange end bedded in red lead cement and other end fixed complete all as specified and as directed by engineer-in-charge. (upto 04 storey High of building)
All as per item No 185 but 5 storey to 8 storey
All as per item No 185 but 9 storey to 12 storey
S&F 32 mm bore brass CP bottle traps for wash basin with inlet and outlet screwdfor pipe and connections incl nessesary packing complete all as specified and as directed by engineer-in-charge. (upto 04 storey High of building)
All as per item No 188 but 5 storey to 8 storey
All as per item No 189 but 9 storey to 12 storey
S & F in repair vitreous china squatting pan of orissa pattern long pan of size 580 mm x 440mm with integral foot rest white with cast iron p or s trap with back inlet including flush pipe of suitable length to connection with existing cistern & make good complete all as specified and as directed by Engineer-in-Charge.(upto 04 storey High of building)
All as per item No 191 but 5 storey to 8 storey
All as per item No 191 but 9 storey to 12 storey
Supplying only 10 litres capacity PVC valveless, syphonic action type, flushing cistern, white colour, low level, white with inlet, ball valve, float and handle including brackets duly painted, 32mm dia PVC flush pipe complete all as specified and as directed by Engineer-in-charge.. (upto 04 storey High of building).
All as per item No 194 but 5 storey to 8 storey
All as per item No 194 but 9 storey to 12 storey
S&F in repair Stainless steel kitchen rack / plate rack of size 31"x36"x10" , made of stainless steel sheet 0.63 mm thick etc complete all as specified and as directed by Engineer-in-charge.. (upto 04 storey High of building).
All as per item No 197 but 5 storey to 8 storey
All as per item No 197 but 9 storey to 12 storey
S&F PVC (SWR) floor trap of 100mm dia, including jointing to waste pipe fixed in cement concrete, (1:2:4) type B1 ( using 20 mm graded crushed stone aggregate). .complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building).
All as per item No 200 but 5 storey to 8 storey
All as per item No 200 but 9 storey to 12 storey
S&F CP grating of 100mm dia, fixed with cement mortar (1:3).complete all as specified and as directed by Engineer-in-charge.(upto 04 storey High of building).
All as per item No 203 but 5 storey to 8 storey
All as per item No 203 but 9 storey to 12 storey
M&L for PCC 1:5:10 Type E2 (using 40mm graded crushed stone aggregate) as in filling sunken floor complete all as specified and as directed by Engineer-in-charge.. (upto 04 storey High of building)
All as per item No 206 but 5 storey to 8 storey
All as per item No 206 but 9 storey to 12 storey
M&L 25mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stone aggregate) as in flooring complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 209 but 5 storey to 8 storey
All as per item No 209 but 9 storey to 12 storey
M&L 40 mm thick PCC 1:2:4 Type B-1 ( using 20 mm graded crushed stone aggregate) and concrete surface is to be finished even and smooth using extra cement complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 212 but 5 storey to 8 storey
All as per item aNo 212 but 9 storey to 12 storey
Taking down chowkat with shutter (without taking off shutters from the frame) n. exc 1.5 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 215 but 5 storey to 8 storey
All as per item No 215 but 9 storey to 12 storey
S&F Solid PVC Door Frame of size 50mm x47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing but wood grain printed PVC sheet used instead of Plain colour PVC sheet & edges will be painted to match with printed sheetcomplete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 218 but 5 storey to 8 storey
All as per item No 218 but 9 storey to 12 storey
S&F Factory Made Solid PVC Moulded Door Shutter, with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 221 but 5 storey to 8 storey
All as per item No 221 but 9 storey to 12 storey
S&F 200 mm long Aluminium anodised, barrel tower bolts of extruded section all as specified and as directed (upto 04 storey High of building)
All as per item No 224 but 5 storey to 8 storey
All as per item No 224 but 9 storey to 12 storey
S&F 150 mm long Aluminium handles, cast type, anodisedcomplete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 227 but 5 storey to 8 storey
All as per item No 227 but 9 storey to 12 storey
S&F stainless steel ball bearing 100 mm long Butt hinges, extruded aluminium alloy steel hinge pin, anodised and fixed, type C-21 complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 230 but 5 storey to 8 storey
All as per item No 230 but 9 storey to 12 storey
Supply & fixing Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples complete,all as specified and directed.complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 233 but 5 storey to 8 storey
All as per item No 233 but 9 storey to 12 storey
Supplying and fixing Mild Steel framed work such as grills, gratings, etc. with ends of bars shouldered and or riveted, or forged into spikes, framed guard bars, barred iron doors, railings and similar work conforming to Fe-290 Gde E-165, complete all as specified and as directed and design/shap approved by by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 236 but 5 storey to 8 storey
All as per item No 236 but 9 storey to 12 storey
Material & labour preparation of new steel and iron surfaces of any description area exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and zinc chrome primer, complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 239 but 5 storey to 8 storey
All as per item No 239 but 9 storey to 12 storey
M&L for cement concrete ( 1:2:4) type B1( using 20 mm graded crushed stone aggregate) as in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 242 but 5 storey to 8 storey
All as per item No 242 but 9 storey to 12 storey
Dismantling cast iron or re-inforced concrete drain pipes including fittings of 100mm bore, jointed in cement mortar complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 245 but 5 storey to 8 storey
All as per item No 245 but 9 storey to 12 storey
Dismantling AC( SWR) pipe up to 150 mm bore including all fittings,heads,shoes,swan necks etc complete all as specified and directed by the Engr-in-Charge.(upto 4 storey of building)
All as item No 248 but from 5 storey to 8 storey of building
All as item No 248 but from 9 storey to 12 storey of building
S&F 110mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 251 but 5 storey to 8 storey
All as per item No 251 but 9 storey to 12 storey
S&F 75mm bore PVC(SWR) pipe single socket in any length rubber ring joints complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 254 but 5 storey to 8 storey
All as per item No 254 but 9 storey to 12 storey
S&F 110mm bore PVC(SWR) pipe bend single socket complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 257 but 5 storey to 8 storey
All as per item No 257 but 9 storey to 12 storey
S&F 110mm bore PVC(SWR) pipe (Single T) equal or unequal with acess door complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 260 but 5 storey to 8 storey
All as per item No 260 but 9 storey to 12 storey
S&F 110mm bore PVC(SWR) pipe (branch piece) single (single Y) equal or unequal complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 263 but 5 storey to 8 storey
All as per item No 263 but 9 storey to 12 storey
S&F 110mm bore PVC(SWR) pipe (SWR) vent cowl complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 266 but 5 storey to 8 storey
All as per item No 266 but 9 storey to 12 storey
S&F 75mm bore PVC(SWR) pipe bend single socket complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 269 but 5 storey to 8 storey
All as per item No 269 but 9 storey to 12 storey
S&F 75mm bore PVC(SWR) pipe (Single T) equal or unequal with acess door complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 272 but 5 storey to 8 storey
All as per item No 272 but 9 storey to 12 storey
S&F 75mm bore PVC(SWR) pipe (branch piece) single (single Y) equal or unequal complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 275 but 5 storey to 8 storey
All as per item No 275 but 9 storey to 12 storey
Material & labour preparation of old painted wooden surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge (upto 04 storey High of building)
All as per item No 278 but 5 storey to 8 storey
All as per item No 278 but 9 storey to 12 storey
Material & labour preparation of old painted steel surfaces of any description exc 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed by Engineer-in-charge (upto 04 storey High of building)
All as per item No 281 but 5 storey to 8 storey
All as per item No 281 but 9 storey to 12 storey
Supply and fixing 4.0 mm thick Sheet glass, ordinary quality and glazing with oil putty in square n exc 0.5 sq. m in each pane complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 284 but 5 storey to 8 storey
All as per item No 284 but 9 storey to 12 storey
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads (upto 12 storey High of building)
Taking down window/door shutter area exc 1 sqm but n exc 2 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 288 but 5 storey to 8 storey
All as per item No 288 but 9 storey to 12 storey
Taking down window / door chowkhat with shutter (without taking off shutters from the frame) area exc 1.5 sqm but n.exc 4 sqm each complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 291 but 5 storey to 8 storey
All as per item No 291 but 9 storey to 12 storey
S&F 2nd Class HW Plain, solid, straight chowkats and frames, wrought framed rebated on the solid, rounded or chanfered, put together with glue pinned at joints all as specified and as directed. (upto 04 storey High of building)
All as per item No 294 but 5 storey to 8 storey
All as per item No 294 but 9 storey to 12 storey
S&F 35 mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both side.(upto 04 storey hight of building)
All as per item No 297 but 5 storey to 8 storey
All as per item No 297 but 9 storey to 12 storey
S&F 35mm thick 2nd class hard wood gauged & skelton shutter, open rebated & prepared to receiv e gauged, ( without sase bar ) eadge of framing plain, chamford or rounded, fitted with cut & mitred beads for securing gauged etc,all as specified and directed. (upto 04 storey High of building)
All as per item No 300 but 5 storey to 8 storey
All as per item No 300 but 9 storey to 12 storey
S&F 2nd class hardwood Small fittings such as brackets of any type, latch and hinge blocks, shaped door and window stops and the like, including all necessary' labours; articles n exc 200 cu. cm each (upto 04 storey High of building)
All as per item No 303 but 5 storey to 8 storey
All as per item No 303 but 9 storey to 12 storey
S& F 50 mm long butt hinges medium weight cold rolled mild steel and fixed all as specified and directed.(upto 04 storey High of building)
All as per item No 306 but 5 storey to 8 storey
All as per item No 306 but 9 storey to 12 storey
S&F 300 mm aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast al alloy all as specified and as directed.(upto 04 storey High of building)
All as per item No 309 but 5 storey to 8 storey
All as per item No 309 but 9 storey to 12 storey
M&L for two coats of synthetic enamel paint over a coat of pink primer area exc.10cm width or girth over new wooden surfaces including preparation of surface complete all as specified and as bdirected by Engineer-in-Charge.(upto 04 storey High of building)
All as per item No 312 but 5 storey to 8 storey
All as per item No 312 but 9 storey to 12 storey
M&L for 25x4mm size mild steel flat iron as in hold fast conforming to Fe-290 Gde E-165 complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building).
All as per item No 315 but 5 storey to 8 storey
All as per item No 315 but 9 storey to 12 storey
S & F second class hard wood beads, straight (n exe 3 sq cm ) for glazed or gauzed joinery, renewed, including mitres etc complete al as specified and as directed by Engineer-in-charge.
All as per item No 318 but 5 storey to 8 storey
All as per item No 318 but 9 storey to 12 storey
Taking down door shutter exe 1 Sqm and n exe 2 Sqm each after including refixing in same opening (upto 04 storey hight of building)
All as per item No 321 but 5 storey to 8 storey
All as per item No 321 but 9 storey to 12 storey
Taking down existing roof treatment and taking out existing cracked plaster by manuallyor mechanically and wire brushing and cleaning the existing surface with water complete all as specified and as directed by the Engr-in-Charge.
Dismantling water tank and removing to store of 2000 litrs capcity (upto 12 storey High of building)
Dismantling wrought iron or mild steel work of any description not otherwise provided for
M&l for PVC perforated sheet 6mm thick, rounded hole of dia 12mm staggered type c/c spacing 25mm with MS frame (size 40X40X5mm thick) fixing on beam and column with nut and bolt of required size including dismantling of old RCC jallies upto four storied of building complete all as specified and as directed. (upto 04 storey High of building) Note:- Shape / Design of jallies as appoved by GE)
All as item No 327 but from 5 storey to 8 storey of building
All as item No 327 but from 9 storey to 12 storey of building
M & L for cutting chases, pinning, in making good to facing where required of of brick wall and pointing in cement motrar 1:3 to ends and cutting chases for concealed water tubing and concealed conduit wiring ete and making good surfaces
All as item No 330 but from 5 storey to 8 storey of building
All as item No 330 but from 9 storey to 12 storey of building
Cutting holes in brick work for inserting hold fast etc including making good the adjacent area with cement and sand mortar 1:3 or PCC 1:2:4 type B, as required at site complete all as specified depth of embedded potion of hold fast or legs measured from the face of the jamb into the wall exc half brick but n. exc one brick (upto 04 storey hight of building)
All as item No 333 but from 5 storey to 8 storey of building
All as item No 333 but from 9 storey to 12 storey of building
S&F in repair towel rail of brass chromium plated tube 19 to 20 mm dia 600 mm long `D' type complete fixed in repairs with brass chromium plated screw complete all as specified and directed. (upto 04 storey hight of building)
All as item No 336 but from 5 storey to 8 storey of building
All as item No 336 but from 9 storey to 12 storey of building
S&F for Powder coated aluminium sliding windows for (three tier) withwith shutter styles 40mm X 20 mm sheet thickness 1.5 mm Two shutter glass and one shutter of wiremess consisting of Stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel wire staples, frame (chowkat) of window shall 100 mm X 44 mm X 1.5 mm thick section with or without rebate including 5 mm thick tinted glass fixed with aluminum beads locking arrangements with each shutter complete in all respect as specified(upto 04 storey hight of building)
All as per item No 339 but 5 storey to 8 storey
All as per item No 339 but 9 storey to 12 storey
Supply and fixing in repair powder coated aluminum ventilator (single leaf single shutter) side hung type with stainless steel butt hinges, one shutter glazed with and including 4.00mm thick plain sheet glass and other shutter with stainless steel wire cloth of 0.36 mm dia of wire and average width of aperture 1.40mm fixed with stainless steel wire staples, rubber gasket, stopper,aluminium anodised handle 100mm long ,aluminium anodised tower bolts 100mm long and peg stay etc, size of aluminum frame shall be 100mmx50mmx1.50mm and shutter frame shall be 40mmx20mmx1.50mm complete all as specified and as directed by the Engr-in-Charge. upto 12 storied bldg. Note : 1 No Glazed shutter and 1 No Gauged shutter constitube one unit.
Materials and labour for providing and fixing anchor fastener system machanical/ epoxy for connections in concrete i/c power drilling, cleaning of holes by air blowing, insertion of epoxy cartridge with plastic nozzles as required, placing internally threaded screw driving of bolts etc. upto to 10mm dia bars and upto twelve storied building complete all as specified and as directed.
S&F powder coated aluminum Fixed Partition wall as faced of stair case and Balcony of frame size 64mm x 38mm x 1.55 mm with standard beads/glazing clips, locking arrangement etc with necessary all fittings including 5 mm thick tinted glass fixed with aluminum beads locking arrangements with complete all as per anufacturer's instructions and all as specified and as directed by the Engr-in-Charge.Up to 4 storey Bldg
All as item No 344 but from 5 storey to 8 storey of building
All as item No 344 but from 9 storey to 12 storey of building
M& L for 15mm thk rendering in CM (1:3) with waterproofing compound for laying of APP membrane complete all as specified and as directed by the Engr-in-Charge. (upto 12 storey High of building)
Applying evenly a tack coat of in 1.2 kg per sq.m including cleaning surfaces complete all as specified and as directed by the Engr-in-Charge. (upto 12 storey High of building)
S&L 3MM thick prefabricated plastomeric water proofing membrane (Polyster rainforced) with spun bonded polyster mat as a core (APP membrane) (Weight not less than 3 kg per sqm ) laid over bituminous coated surface of roof and applied with lpg torch and applying uniform pressure with a roller /wet cloth to ensure to remove entrapped air ,if any all as per manufactureer instrucction .The APP membrane shall be overlap of not less than 100mm and 150mm as end lap and side lap respectively sas per manufacturer instruction .The over laping and joints will be thermosealed with the propane torch complete all as specified and as directed by the Engr-in-Charge. (upto 12 storey High of building)
M& L for cement concrete tiles size n' exc 0.16 SQM, 20-25mm thick, machine pressed tiles, set jointed and pointed in neat cement slurry on roof over and including 15 mm thick bedding layers in CM 1:6, cut and finished neatly and polished etc and complete all as specified.(upto 12 storey High of building)
Supply and fix rotational moulded PVC water storage tank 2000 Ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I. (upto 08 storey High of building)
Disconnecting existing water tank, setting aside for cleaning & removing scale and dirt and fixing in same position of size exc 1000 and n.exc 2000 litres.(upto 12 storey High of building)
S&F toilet paper holder fixed in repairs to wall with chromium plated brass screws complete all as specified and as directed.(upto 4 storey High of building)
All as item No 353 but from 5 storey to 8 storey of building
All as item No 353 but from 9 storey to 12 storey of building
Supply & fixing in repair wash down water closet (pedestal pattern) including connection to drain (or outgoing pipe) and to flush pipe etc. and making good the damaged surfaces complete all as specified and as directed by the Engr-in-Charge. Upto 4 storey of building
All as item No 356 but from 5 storey to 8 storey of building
All as item No 356 but from 9 storey to 12 storey of building
S&F PVC water closet seat cover heavy duty coloured closed pattern with flat bottom and cover and mild steel CP hinnging device complete.(upto 4 storey High of building)
All as item No.359 but from 5 storey to 8 storey of building
All as item No 359 but from 9 storey to 12 storey of building
S&F brass CP soap dish, fixed with brass screws or embedded in wall. or equivelent.
All as item No 362 but from 5 storey to 8 storey of building
All as item No 362 but from 9 storey to 12 storey of building
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete in all respect as specified upto 4 storey
All as item No 365 but from 5 storey to 8 storey of building
All as item No 365 but from 9 storey to 12 storey of building
S&F in repair Brass CP wall mixer with half or qtr turn for mixing hot & cold water screwed down for iron pipeand fixed for upto 4 storey
All as item No 368 but from 5 storey to 8 storey of building
All as item No 368 but from 9 storey to 12 storey of building
S&F in repair wash hand basin mixture Brass CP tap for mixing hot and cold water with qtr or half turn including three joints to 15 mm bore pipes or union and pluging and screwing to wall complete fixed in repair.upto 04 story
All as item No 371 but from 5 storey to 8 storey of building
All as item No 371 but from 9 storey to 12 storey of building
S&F Sheet glass shelf assembly consisting of 5.5mm thick sheet glass shelf 12cm wide with chromium plated bracket guard and railing 60cm long (upto 04 building).
All as item No 374 but from 5 storey to 8 storey of building
All as item No 374 but from 9 storey to 12 storey of building
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and waste; including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm and including 32mm waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms/40mm-60 gms)
All as item No 377 but from 5 storey to 8 storey of building
All as item No 377 but from 9 storey to 12 storey of building
Supply and Fixing in repair of drapery of made of electric resistance welded MS pipe of 21 mm dia having a coating of corrugated virgin PVC extrusion and cover with ABS plastic,f complete all as specified. (upto 12 storey hight of building)
All as item No 380 but from 5 storey to 8 storey of building
All as item No 380 but from 9 storey to 12 storey of building
Supply and fixing of end finials for drapery rod and including closed type stainless steel all brackets fixed onwall, complete all as specified and as directed (upto 12 storey High of building)
All as item No 383 but from 5 storey to 8 storey of building
All as item No 383 but from 9 storey to 12 storey of building
S&F for framed brackets of angles or tees with web and flanges cut to shape, drilled and counter sunk for screws including bending and welding angles as necessary, gusset plates, riveting, etc n,exc 10 kg each brackets confirming to Fe 290. Grade-E- 165(brackets over 10kg each to be measured under structural steel) upto four storied building complete all as specified.
All as item No 386 but from 5 storey to 8 storey of building
All as item No 386 but from 9 storey to 12 storey of building
S&F for pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering /cladding to wall, fixed with self taping screw upto four storied building complete all as specified.
All as item No 389 but from 5 storey to 8 storey of building
All as item No 389 but from 9 storey to 12 storey of building
Supply & fixing in repairs Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with SS wire staples complete,all as specified and directed.complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 392 but 5 storey to 8 storey
All as per item No 392 but 9 storey to 12 storey
S& fix in repair Prelaminated particle board 18/19 mm, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work in cup board for short area complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 395 but 5 storey to 8 storey
All as per item No 395 but 9 storey to 12 storey
S& fix 18 mm thick HDMF board inner side laminated white colour and one site decorative lamination (teak wood finishes) complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 398 but 5 storey to 8 storey
All as per item No 398 but 9 storey to 12 storey
S & F 2 mm thick wall care putty on wall(in Two layers) complete all as specified and as directed by Engineer-in-charge. (upto 04 storey High of building)
All as per item No 401 but 5 storey to 8 storey
All as per item No 401 but 9 storey to 12 storey
Supplying and fixing 1.25mm thick steel rolling shutters, with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual typecomplete all as specified and as directed.
S&F lock plate bracket made of angle 40X40X5 mm, flat 25X6 mm, cleat, latice flat & locking arrangement etc of rolling shuttes including necessary welding / riveting and one coat of red oxide primer including taking down old lock plate complete all as specified and directed.
Providing anti termite (post construction) along the external wall below concrete or masonary apron using chemical Chloropyritphos 20 EC or linane 20 EC (ISI Marked) emulsion @ 2.25 literes per linear meter including drilling and plugging holes etc in aprons/plinth protection , complete all as specified and directed by Engineer-in-Charge.
Providing anti termite (post construction) of soil under existing floors using chemical Chloropyritphos 20 EC or linane 20 EC (ISI Marked) emulsion @ one leter per holes , 300 mm apart along the junction of floor and walls including drilling and plugging 12 mm dia holes with cement mortar 1:2 ( 1 Cement : 2 coarse sand) to match the existing floors.
Providing anti termite (post construction) of voids in masonary using chemical Chloropyritphos 20 EC or linane 20 EC (ISI Marked) emulsion @ 1.00 liter per holes , at 300 mm intervals including drilling 6 mm dia holes at downward angle of 45 degree and repluging the holes with cement mortar (1:2) to match the existing surface , complete all as specified and directed by Engineer -in-Charge.
Providing anti termite (post construction) at the point of ontact of wood work by chemical emulsion ( in iol or kerosene based solution ) @ 0.50 leter / holes by drilling 6 mm dia holes at a downward angle of 45 degree at 150 mm centre angle of 45 degree at 150 mm centre to centre and sealing the same,
S&F Corner glass shelf assembly consisting of 5.5mm thick sheet glass shelf 300mm long complete all as specified and directed Make Prayag or equivalent (upto 04 building).
All as item No 410 but from 5 storey to 8 storey of building
All as item No 410 but from 9 storey to 12 storey of building
S & F Plywood for moduler kitchen, grade BWR, type BB, fixed with screws to timber frame work 19 mm thick incl all necessary fittings complete in all respect as specified
S & F Decorative laminate 0.9 mm thick type 1 of surface finish, colour and pattern as approved, fixed with approved adhesive as per manufacturer's instructions complete in all respect as specified
S & F Ball catches with 8mm dia steel ball, and brass body and striking plate including letting in and fixed complete in all respect as specified
S & F stainless steel soft close hydraulic clamp on concealed hinges for half / full overlay door with 0-8 degree crank, suitable for door of thickness 14mm to 22mm door moulted type, concealed hinge for easy installation, size of cup 11.5 mm with necessary fittings/ fixture etc complete all as specified and directed by Engineer-in-Charge.
S & F stainless steel handle of 100 mm length for kitchen cabinet including necessary fitting and fixture complete in all respect as specified and directed by Engineer-in-Charge.
M & L 2nd class hardwood Plain fillets.square, rectangular or triangular in section, clean sawn, secured with nails or brads Not exc 3 Sqm complete in all respect as specified
S & F in repair for mild steel slot profiles of 1.25 mm thick including taking down old profiles complete all as spd and as directed.
S & F Zinc Coated SS Steel ball type 24 " telescopic channel 1" width incl all necessary fittings complete in all respect as specified (upto 12 storied of bldg)
Dismantling and taking down point wiring (light, fan, socket and power complete including fixtures and fittings such as switches ceiling roses, pendents , regulators, sockets, light fittings etc. removing materials for taking credit ( credit for above items should be made as per conditions separately) and making good distrubed surfaces of walls, floors, etc.
M&L for point wiring with PVC insulated unsheathed stranded copper conductor cable FRLS of size 1.5 Sq mm with proper colour coding and including concealed PVC conduit 20 mm dia medium duty ISI marked with all necessary fittings for mounting of modular switches/sockets including 1.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly for one light / ceiling fan/exhaust fan controlled by one switch complete including cutting, chasing the surface on wall and then making good the same in CM 1:3 complete all as specified and directed by Engr- in-charge. Make of wire : Finolex/Havells/KEI Industries Ltd Make of PVC conduit and fittings : BEC/Prestro/Avon Plast/Finolex
All as per item No. 422 above but of one bell point controlled by one bell push with cables of 1.5 sqmm size
All as per item No. 422 above but 3 pin 5 amps socket out let point with the same board with other switches with cables of 1.5 sqmm size
All as per item No. 422 above but for one 5 amp socket on independent board with cables of 1.5 sqmm size
All as per item No. 422 above but using 2.5 sq mm size stranded copper conductor cable for one 16 amp switch socket outlet on independent board including 2.5 sq mm PVC insulated unsheathed stranded copper conductor as earth lead and connected to common earth doly complete all as specified and directed by Engineer- in-Charge.
All as per item No. 422 above but for one light point controlled by two switches two ways.
S& F sunken flush metal GI boxes for fixing of modular switches/sockets flush to the walls complete for 2 modules.
All as per item No 428 above but for 3 modules
All as per item No 428 above but for 4 modules
All as per item No 428 above but for 6 modules
All as per item No 428 above but for 8 modules
S&F modular cover plate with frame for fixing of modular switches/sockets complete for 1 modules (Note:- switch and sockets will be measured and paid separately)
All as per item No. 433 above but for 2 modules
All as per item No. 433 above but for 3 modules
All as per item No.433 above but for 4 modules
All as per item No. 433 above but for 6 modules
Al as per item No. 433 above but for 8 modules
S&F switch modular type 6 Amps 230V AC complete one way
S&F switch modular type 6 Amps 230V AC complete two way
S&F modular bell push 5 Amps.
S&F for modular socket outlet 3 pin 5 Amps 230 volts .
S&F modular socket outlet multipurpose 3 pin 16 Amps and one 6 Amps controlled by one switch.
Supply and fix modular type switch, one way 16 Amps, 1 module complete all as specified and directed.
S&F modular electronic step type fan regulator 230 volt , 2 module .
S&F Polycorbonate /PVC ceiling rose of size 65x50mm single phase
S&F Call bell, musical AC 230 volt single pole.
Supply and fixing LED lights fitting 1x 18-20 W, 220V, AC decorative box type aluminimum extruded, with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete.all as directed. Make : Crompton CAT No : CCS-100-20-65-HL2-DP-NWH Bajaj CAT No :- BCLAB 20W LED P S Havells CAT No :-LUMILINE+BS20WLED830SPCSS
Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 9-12 watt 220 V AC decorative type aluminium exturded with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete Make :Crompton CAT No : CCS-102-10-65-SL-DP-NWH Philips CAT No :- CAT No BN021LED12S6500 PSU Havells CAT No :- LUMILINE+BS10WLED865SPCSS
Supply and fixing Decorative type LED Wall bracket light fitting having Chromium Plated steel body , frosted glass defuser, suitable for 7-10 watt LED lamps complete all as specified and directed. Make : Lukar CAT No :- LWL112-1 Havells CAT No :- LHFOECE1TZ10014 STYLO or equivalent
S&F AC starter unit consisting of one 25 Amp capacity starter, one 240 V 25 Amps 10 KA SPN MCB, one 25 Amps socket and one 25 Amps plug top prewired including taking down complete all as directed. Make : Crabtree/Legrand/Anchor/ABB
Taking down unserviceable rusted / damaged MCB DBs of any type and way along with any type MCB and keeping serviceable MCB in safe custody in re-use in the work and making good to the distubed surfaces of walls etc. complete all as specified and as directed.
S&F MCB TPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 415 volts complete all as specified and as directed.
S&F MCB SPN DB made up with sheet metal double door, phosphorised, power coated, neutral link, earth bar and din rail, 4 way with 200 amps rated bus bar, 230 volts complete all as specified and as directed.
S&F MCB SP 5-32 amps 230 volts 10KA breaking capacity complete all as specified
S&F MCB SPN 40-63 amps 230 volts 10KA breaking capacity complete all as specified
S&F MCB TPN 63 amps 415 volts 10KA breaking capacity complete all as specified
Taking down aluminimum sub mainwiring alongwith damaged casing capping /PVC conduit pipe from the wall roof or in floor and making good disturbuted surfaces complete all as directed
S&F Sub main wiring with proper colour coading 4 run of single core PVC insulated unsheathed stranded copper conductor FRLS of size 10 sqmm & 2 run of PVC insulated unsheathed stranded copper conductor of size 10 Sqmm as earth lead drawing into rigid non metalic PVC conduit of suitable size ISI marked. Note: Four run of 10sqmm cable and two run of 10 sqmm earth cable will be measured as single length.(From DB TPN to meters)
All as per item No. 459 above but with two run of single core 6 sqmm and one run of 6 sqmm cable complete ( From Meters to DBs) Note: Two run of 6 sqmm cable and one run of 6 sqmm cable will be measured as single length
All as per item No. 459 above but with two run of single core 4 sqmm and one run of 4 sqmm cable complete. (for two nos of ACs at each qtr) Note: Two run of 4 sqmm cable and one run of 4 sqmm cable will be measured as single length
Supply and fixing 5 star rated water heater(geyser) storage type Energy efficient SPHP Technology inner container ,A.C single phase 230 Volt,50 Hz of storage capacity 25 ltrs Vertical type complete connecting upwater heater , including fixing of hold fast 10 cm long including washers complete including dismanling of old unsv geyser from its existing position as specified Note : old dismantled unsv Geysers will be deposited to MES store of AGE E/M-II at turf view for further disposal under departmental arrangements.
Supply and fixing Five star rated with brushless direct current motor (BLDC) ceiling fans 1200 mm sweep complete with blades, down rods, electronic regulator and accessories, 230 V, Min air delivery 210 CFM with service value 6.00 BEE complete including dismanling of old unsv Ceiling fan from its existing position all as specified and directed. Note : Old dismantled unsv Ceiling Fans will be deposited to MES store of AGE E/M-II at turf view for further disposal under departmental arrangements.
Supply and fixing Five star rated with brushless direct current motor (BLDC) ceiling fans 1400 mm sweep complete with blades, down rods, electronic regulator and accessories, 230 V, Min air delivery 245 CFM with service value 6.00 BEE complete including dismanling of old unsv Ceiling fan from its existing position all as specified and directed. Note : Old dismantled unsv Geysers will be deposited to MES store of AGE E/M-II at turf view for further disposal under departmental arrangements. .
Supply and fixing Wall Mounted fan 300 mm sweep, voltage range 220V to 230 volts, 50 Hz, single phase complete with speed regulator and oscilator with pulling threads complete as directed.
Supply, installaion , testing and commissioning Electric kitchen chimney , auto clean type with Baffle filters, minimum length 90cm (suitable for 3 to 5 burner stove) with suction capacity 1425 m3/hour (min) including exhaust duct with alll fixing accessories and making hole on the wall for passing the exhaust duct complete all as specified and directed.
Supply and fixing Exhaust fan 250 mm sweep, with polycorbonate blades 230 volts 50 Hz single phase including louvres & shutters nuts and bolts complete including modification of existing hole (if required) all as directed. .Make: Havells or equivalent in Bajaj/CG Note : Old dismantled unsv exhaust fans will be deposited to MES store of AGE E/M-II at turf view for further disposal under departmental arrangements.
S & F in repair LED luminaire 600 mm x 600 mm, 34-36 watt, 220 V AC Surface type with high efficiency PMMA diffuser soft glare free light complete with inbuilt driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor wire of suitable size complete all as specified and as directed by the Engr-in-Charge. (for Lift Lobby) Make : Crompton CAT No :- LCTLSNE-36-FO-CDL Havells CAT No- PLUTOSURFACE2X2PLS34WLED857S Bajaj CAT No -BZSSQL 36LLED WHGX
S & F in repair LED luminaire 600 mm x 600 mm, 34-36 watt, 220 V AC Surface type with high efficiency PMMA diffuser soft glare free light complete with inbuilt driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor wire of suitable size complete all as specified and as directed by the Engr-in-Charge. (for Lift Lobby) Make : Crompton CAT No :- LCTLSNE-36-FO-CDL Havells CAT No- PLUTOSURFACE2X2PLS34WLED857S Bajaj CAT No -BZSSQL 36LLED WHGX
Taking dlown carefully the existing LED light batten fitting of any wattage 20/10W and any size by unscrewing from wall/outlet boxes and fixture and keeping in safe custody and refixing the same after completion of new wiring work and complete all as specified and as dircted by the Engr-in-Charge (Note :- Any breakage/damage of light fitting during taking down/ refixing shall be make good by the contractor with his own cost)
Supply and fixing Fire alarm control panel 8 zone complying with IS 2189, micro controller based with 32 character LCD display , inbuilt battery charger and battery with inbuilt common hooter connection point including taking down of existing unserviceable one complete all as specified and directed.
Supply and fixing Fire alarm control panel 16 zone complying with IS 2189, micro controller based with 32 character LCD display , inbuilt battery charger and battery with inbuilt common hooter connection point including taking down of existing unserviceable one complete all as specified and directed.
Supply and fixing manual call point resettable type MS body red in colour including taking down of existing unserviceable one complete all as specified and directed.
Supply and fixing Hooter MS body red in colour including taking down of existing unserviceable one complete all as specified and directed.
Supply and fixing control wiring of MCP and hooter with 2 runs of 1.5 sqmm PVC insulated FRLSH copper conductor wire in PVC casing Caping of suitable size including taking down of existing unserviceable wiring complete all as specified and as directed.
Dismantling , Supply and fixing single pointed air termination rod of 12mm dia and 600mm long complete all as specified and as directed by the Engr-in-Charge.
Dismantling , Supply and fixing single aluminium strip 25x3.15 mm complete with saddles and fixing screws for roof conductor/down conductors all as specified. Including pocelain insulator complete all as specified and as directed by the Engr-in-Charge Note :-Rate quoted shall deemed to be inclusive of scaffolding etc in high rise buildings
Dismantling , Supply and fixing earth continuity conductor 32x6mm GI strip or main earthing lead fixed to wall on batten or recess or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc. complete all as specified and as directed by the Engr-in-Charge.
Dismantling ,Supply & Laying GI tubing light grade fixing for lightning conductor of 40mm bore complete all as specified and as directed by the Engr-in-Charge.
Dismantling ,Supply & Laying GI tubing light grade fixing for lightning conductor of 80mm bore complete all as specified and as directed by the Engr-in-Charge
Dismantling , Supply and fixing Test point terminal Box made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including taking down complete all as specified and as directed by the Engr-in-Charge.
NARSINGH DEVELOPERS LLP
DNS CONSTRUCTION COMPANY
Hindustan Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .