Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.2 LAccepted-AOC LANE NO 5 HNO 560 SHAM VIHAR TALAB TILLO JAMMU | L1 | Accepted-AOC Accept | |
| 2 | L2₹8.1 L+₹80,377.60 (11.1%)Rejected-AOC | L2 | Rejected-AOC Reject | |
| 3 | L3₹8.5 L+₹1.2 L (16.7%)Rejected-AOC 00 KIWADI SAFEDABAD BARABANKI BARABANKI UTTAR PRADESH 225001 | BARABANKI | UTTAR PRADESH | 225001 | L3 | Rejected-AOC Reject | |
| 4 | Rejected-Technical | - | Rejected-Technical No Similar Work Done Document. | |
| 5 | Rejected-Technical | - | Rejected-Technical EMD and Tender Cost not submitted. |
Tender Value
₹5.5 L
EMD Value
₹11,100
Closing Date
31 Mar 2021, 5:00 pmClosed
EE BBNDA BADDI
BBNDA BADDI
Providing and Installation of 2 Nos. High Mast. Lights at CETP Kenduwal, Baddi
2021_BBNDA_45862_1
BBNDA-06(PROJECT)NIT/1929-39 DATED 22.03.2021
Open Tender
Electrical Works
Item Rate
30 days
BADDI
Please refer Tender documents.
2 documents required · 2 mandatory
₹350
EE BBNDA BADDI
₹11,100
8 Jun 2021
24 Mar 2021
3 Apr 2021
24 Mar 2021
31 Mar 2021
24 Mar 2021
24 Mar 2021 - 30 Mar 2021
Amount
Supplying/Erection of high power LED Flood light luminaries High-brightness White LED's sources with high transmittance flat tempered glass cover and peanut LENS on each LED's system lamen output of minimum 17200 lumens in maximum 172 W. System watt consumption with 100 ims/watt system luminous effcacy, 5000k colour temprature & 70 CRI value for ensuring good quality light output life of at least 50,000 hours at 70 % lumen maintenance & LED driver efficency >85 % power factor greater than 0.90,THD< 15% & min 4kv surge protection with operating voltage rannge from 120-170V for ensuring life long high performance of luminaire the fixture is made of LM 6 pressure die cast aluminium with engraved/embossed company name & have IK05 & IP 65 class i protection with NABL Acceredited LM 79 & LM 80 report The fixture should be comprehensively warranted to be required or replaced for any defect with in five year of installation . The Luminary should not be over power derived the fitting shall be mounted on the plate bracket on existing pole including making connection testing & energizing complete in all respect to the entire satisfaction of Engineer- in-Charge The luminary should be tempo BVP410LED 172 CWHE NB FG S# X T Of Philips OR equivalent of BAJAJ/HAVELLS/KASELEC SCHEREDAR/GE/Twinkle male The detail specification for supply of LED flood light luminary is as :-1)Input voltage 120-270 V AC/50Hz 2)System Efficacy Minimum 100 Lm/W 3) Uniformity Ratio of min to Av illumination Min 0.3 4) Usage hours 10-12Hrs/Day 5)Power Factory 0.90 6)Life Expectory Minimum 50,000 Hrs with 70% Lumens 7)Power Consumption of system 172 watt Maximum 8) Lumen Output Minimum 17200 Lumens 9) Color temp 5000-6000 k cool white 10) LED High power SMD LED 11)Working Humidity 10%90% as 1 to MSL 12) Ingress Protection IP-65 13) Surge Protection Minimum 3 KV 14) Coloring Rendering Index >70 15) Total Harmonic Distortion 15% Max 16) Average Lighting Beam Angel 120Deg 17) Make of LED Make NICHIA/OSRAM/PHILIPS/LUMILED/CREE 18)Luminary Casing Pressure die cast aluminium with toughened glass cover 19) Control of circuit Compatible to LED 20) Lamp starting time Should not be more than 10 sec 21)Thermal Management System Good Thermal Management 22)System Driver more than 5% efficency 23)Applicable standard The fixture should sonfirm to application BIS/IES standard /IESNA LM79_80 from NABL accredited lab. 24)Wind Pressure capable to with stand 160MPH wind velocity 25) Manufacturer should produce NABL,accredited LM-79 and LM-80 Lab certificate for verifying the above mentioned system lumen output ,system power consumption & system Luminous efficacy
Supply & laying of ISI marked 4 core 16 mm Sq PVC insulated aluminium conductor armoured cable U/G without protective covering :- Supply and laying of PVC insulated armoured ISI marked 4 core 16 mm sq. 1100V .grade Havells /Finolex/Ecko/Lapp/Polycab?KEI cable conforming IS:1554(Pt I) amended upto date having the specification to be laid under ground 1 Mtr. below the ground level without sand and protective covering but including excavation and back filling the trench as per DSR code 1.21 MV CB GR-25 W(External) . Specification of the cable as below :- i)Conductor Aluminium ii)Core -4 iii)Working Voltage - 1100V iv)Nominal cross Section -16mm2 v) Minimum No. of wire - 6 vi)Insulation Thickness-0.1mm(Nominal) vii)Inner Sheath Minimum Thickness - 0.3mm viii) Outer Sheath Minimum Thickness -1.40mm ix)Normal size of Armoured Wire /Strip - 4 x 0.8mm x) Approximate O.D -22mm Maximum d.c resistance at 20 Deg.c-1.91 ohm/km The work shall be executed to the entire satisfaction of Enginner- in -Charge .
Supply & laying of ISI marked 4 core 16 mm Sq PVC insulated aluminium conductor armoured cable loode in trench/pipe :- Supply & Laying of ISI marked 4 core 16mm sq Aluminium conductor armoured cable of make Havells/Finolex/Ecko/Lapp/Polycab/KEI conformng IS:1554(Pt. I) amended . The cable shall be laid as per DSR Code 1.7MV CBPIP(external). The specification of the cable as below :- i)Conductor Aluminiun ii)Core - 4 iii) Working voltage -1100 V iv) Nominal Cross Section -16mm2 v) Minimum No. of wire - 6 vi)Insulation Thickness-0.1mm(Nominal) vii)Inner Sheath Minimum Thickness - 0.3mm viii) Outer Sheath Minimum Thickness -1.40mm ix)Normal size of Armoured Wire /Strip - 4 x 0.8mm x) Approximate O.D -22mm Maximum d.c resistance at 20 Deg.c-1.91 ohm/km The work shall be executed to the entire satisfaction of Enginner- in -Charge .
Supply & Laying DWC pipe 51/63mm with hand bockey :- Supply and laying of 50/63mm(I/D & O/D) Double Wall Corrugated (DWC)High Density Polyethylene pipe (HPDPE Density 240 to 958 KG/Cm3)having corrigation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1 +0.1mm and for inside layer 1.2+0.1mm conforming to ISI4930(P-II)and PSEN-50086(P-I & II) of make duraline /Rex/Zen duct/ Gemini/ The pipe should be laid 3 feet below ground /road level with hand bockey without cutting of road for laying cables etc.including cost of digging and refilling of pits complete in all respect to the entire satisfaction of Engineer-in-Charge .
Supply & Laying DWC pipe 51/63mm with hand bockey :- Supply and laying of 50/63mm(I/D & O/D) Double Wall Corrugated (DWC)High Density Polyethylene pipe (HPDPE Density 240 to 958 KG/Cm3)having corrigation on the outer wall and plain surface inner wall with average wall thickness for outer layer as 1.1 +0.1mm and for inside layer 1.2+0.1mm conforming to ISI4930(P-II)and PSEN-50086(P-I & II) of make duraline /Rex/Zen duct/ Gemini/ The pipe should be laid 3 feet below ground /road level by digging the ground upto 3 feet & laying of DWC pipe for laying L.T(up to 1.1 KV grade) cables etc. including cost of digging and refilling of pits/Trench complete in all respect to the entire satisfaction of Engineer-in-Charge of work .
Supplying /Erection /Testing & Commisioning of 12.5Mtrs High Mast Lightining System having mInimum top dia 150mm & Bottom dia 410mm. System suitable for 6 Nos. Luminaries complete all respect as per detail specification given below :- 1)Mast shell be in two sections.hot dip galvanized inside & out side in single dip. suitable for wind velocity as per IS 875 part 3/1987 .There shall be only one longitudinal seam weld v section and no circumferential weld it shall also incude accesories for high mast including head frame 2 point suspension system with steel wire rope 6mm dia(7/19 costruction ) double drum winch galvanisation lowering of lantern carriage . ii) Foundation bolts manufactured from special steel along with nuts washers,anchor plate and template with anti aviation obstruction lights with 2 nos. LED lights of 6-11 watt Detail specification:- i) Height of Mast :- 12.5 mtr.(including the height of head frame ) ii) Wind speed :- 180km/hour as per IS-875(part iii) iii) The high mast & head frame shall be structurally suitable to accommodate the 6 no. Flood lights 7 its control gera boxes. iv) The entire high mast structure (internally 7 externally) and all MS parts shall be hot dip galvanized asm per BS - 729 IS -1461 or equivalent. v) Material :- The high Mast section should be manufactured with best steel garde in compliance with BSEN 10025- EQ or equivalent with yield strength not less then 355 MPA the head frame shall also be steel construction of steel grade as per WPS/PQR in accordance wuth BS-5135 or AWSD 1.1 vi) Welding All welding shall be undertaking & performed as per Telescope slip jints (stress fit) vii)Structure :- Continuesly tapered polygonal with no circumfrence weld on shaft .type of joint Telescope slip joints(stress fit) viii)Thickness :- Bottom section Min-4mm Top section Min - 3mm ix) Headframe : (Lantern carriage arangement)Galvanized Fabbricated lantern carriage for fixing & holding the flood light fittings & control gear boxes provided with suitable winch arrangement to lower & raise the lantern carriage assembly x)Earthing . the mast shall be bounded properly to the existing earth .xi) Electrical system & cables :- A suitable treminal box shall be provided at the base compartment of high mast for terminating the incoming cables . The internal connection from the bottom to the top shall be made with special trailing cables (including supply ) and erection of cables for luminary and aviation light mast for terminating the incoming cables . The internal connection from the bottom to top shall be made with special xii)Lighting finial :- One number heavy duty hot dipped galvanized lightingfinial(minimum 1.2mt in lenght) shall be provided at the center of head frame . It shall be bolted steadily to the head frame to get a direct conducting pathe to the earthe through the mast . xiii)3 Phase 1.5K.W power tool suitable for 16 Mtr high Mast . It includes cost of 1 No. starter to be provided in the pedestal . It also includes the cost of connection with 10mm2 copper wire from starter to motor in the High Mast Panel to starter complete in all respect as per satisfaction of E.I.C xiv) It should include MCBTPN of capacity 63 A of Havell's/Haggers/Siemens/ASCO inside the base compartmenter/J.B to terminate the incoming /outgoing cables .The firm /manufacture will give thhe following guranteed parameters in respect of the High Mast a) Height of the High Mast . b)Lenght of each section & No of sections. c)Material of construction Lenght of over lap at each joint d)Top & bottom diameter of the pole e) Thickness of each section in mm f)Base/Bottom plate thickness g)No. & size of rag bolts along with anchor plate h)Make of Manufacturer i)Drawing /catalogues of High mast to be attached The firm submitt the type test report of high mast for structure stability as per requirement before installation of the mast . The Mast shall be of Philips/Bajaj/G.E/ Surya?val Moat Makes only . The work shall be executed to the entire satisfaction of Engineer-in -Charge .
RCC Foundation :-Design & Construction of R.C.C foundation with M-20 cement concrete & steel reinforcement suitable for installation off 12.5Mtr. High Mast. The Complete foundation design & calculation shall be got vetted from PEC/TTTI by the firm at its own cost before execution of work to entire satisfaction of Engineer-in-Charge .
Supply & errection of earthing of High Mast with G.I strip 25x3 mm thick G.I tape riveted to 600mm X 600mm X 3mm thick G.I plate and bound 4.5 mtr. For suitable depth below ground level with all respected i.e. charcoal/salt . The work will be executed to the entire satisfaction of Engineer-in-Charge .
Supply & Erection of Three Phase Aluminium Bus Bar Supply & Erection of Three phase Aliminium Bus Bar of size 300 mmx 25mmx4mm with L type fuse unit to be fixed on Porcelain Insulators in the existing pedestal with required nuts,bolts & M.S sheet . The fuse links should be equal to the number of out going circuits .The work shall be executed to the entire satisfaction of Enginner-in-Charge .
M/s Ravindra Electrical
Kumar Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .