| 1 | L1₹2.8 CrAccepted-AOC NO 1 7 INSPECTOR QUARTERS PGR LINE BEHIND CPO BUILDING ANNATHANAPATTI LINEMEDU SALEM 636 006 | SALEM | TAMIL NADU | 636006 | ₹2.8 Cr | L1 | Accepted-AOC Successful tenderer |
| 2 | L2₹2.8 Cr+₹1,051.25 (<0.01%)Rejected-AOC 53 MIDDLE STREET ARUMALAI TIRUKOILUR VILLUPURAM DISTRICT | VILLUPURAM | TAMIL NADU | 604001 | ₹2.8 Cr+₹1,051.25 (<0.01%) | L2 | Rejected-AOC Unsuccessful tenderer |
| 3 | L3₹2.8 Cr+₹3.0 L (1.10%)Rejected-AOC NO 2 15 SANTHIYUR ATTAYAMPATTI POST MALLUR VIA SALEM DISTRICT 636 203 | NAMAKKAL | TAMIL NADU | 636203 | ₹2.8 Cr+₹3.0 L (1.10%) | L3 | Rejected-AOC Unsuccessful tenderer |
| 4 | Not Admitted-Fee/PreQual/Technical/Finance NO 18 A KACHI MADA STREET NEAR ALWAR BANGULOW KANCHIPURAM 631 502 | KANCHIPURAM | KANCHIPURAM | TAMIL NADU | 631502 | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
| 5 | Not Admitted-Fee/PreQual/Technical/Finance | - | - | Not Admitted-Fee/PreQual/Technical/Finance Others-Original Demand Draft not handed over for Tender processing fee. |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
17 Mar 2025, 6:00 pmClosed
O/o the Superintending Engineer/TNPHCL/NC/Salem
The Superintending Engineer/TNPHCL/North Circle, No.1 and 7, Inspectors quarters, PGR Line, Behind CPO Building, Annadhanapatty, Linemedu, Salem 636 006.
Construction of Fire and Rescue Service Station with development works at Thiyagadurgam in Kallakurichi District
2025_TNPHC_529734_1
SE/NC/DB/142/2025
Open Tender
Civil Works
Lump-sum
210 days
Thiyagadurgam in Kallakurichi District
Refer the tender documents
7 documents required · 7 mandatory
₹0
₹1.7 L
5 Apr 2025
4 Mar 2025
19 Mar 2025
4 Mar 2025
17 Mar 2025
4 Mar 2025
Amount
1.1 : Earth work excavation in all soils (including refilling) a. 0 to 2 mt.
b. 2 to 3 mt.
1.5 : Earth work excavation for Open foundation (excluding refilling) a. 0 to 2 mt.
1.6 : Earth work excavation for Open foundation for drains (excluding refilling) width upto 1.25 m a. 0 to 2 mt.
2.6: Supply and Filling of 40mm HBSJ
2.7: Supply and Filling of 20mm HBSJ
13.1 : Filling with Excavated Earth
21.2 : Teak wood Wrought & Put up a. T.W. over 2 m & below 3 m
b. T.W. below 2 m length.
23.3 : S&F of Magnetic door catches
25 : M.S.Holdfast
30 : Ellispattern
31 : Weathering course
37.1 : White washing 3 coats (slaked)
39 : M.s Grills
40 : Painting - New "wood work"
41 : Painting - New "iron work"
46 : S & F 20 mm dia Alu. Hanger Rod
47 : S & F Alu Towel rail 75 cm long
48 : S & F 5 pin Coat stand
49 : S & F chromium plated 8 guage Picture Hook
50.3 : Supply and planting avenue trees
50.4 : Providing Tree guard
52 : PVC Water supply (ASTM) a. 32 mm dia
b. 25 mm dia
c. 20 mm dia
52.1 : Supplying and fixing of 20mm dia "B" Class GI pipe for Hot water line (Fully Concealed in walls)
53.3 : C.I. Steps ( 5 kg)
55.2 : Flat Back Urinal
Electrical arrangements 69 : 16 Amp. Power plug
72 : Box type Fibre Fan hook
74 : Charges for fixing of "Fan"
76 : 8 SWG wire
78 : Earthing Station IS3043 (Type I)
81 : Meter cupboard
86 : Anti termite treatment
ANNEXURE-I 2.1.1 : Supplying and filling Gravel
2.1.3 : Filling crushed stone sand
3.1.1 : C.C.1:5:10 for Foundation & Basement (using crushed stone sand)
3.2.1 : P.C.C. 1:2:4 for Foundation & Basement and other similar works (using crushed stone sand)
3.3.1 : P.C.C. 1:8:16 using 20 mm broken brick jelly (using crushed stone sand)
3.9.1 : PCC 1:3:6 for foundation & basement using 20mm metal (using crushed stone sand)
6.2.1.1 : Brick work in C.M. 1:5 (F& B) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM²
8.1.1.1 : Standardised concrete Mix M20 Grade concrete. (using crushed stone sand) a) In Foundation and Basement.
b) In Stilt / Ground Floor
c) In First Floor.
d) In Second Floor.
9.2.1.1: Brick work in Cement Mortar 1:6 (One of cement and six of Crushed stone sand) with Admixture using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Stilt / Ground floor
b. In First Floor
c. In Second Floor
10.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 110mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² in the following floors a. In Foundation and basement
b. In Stilt / Ground Floor
c. In First Floor
d. In Second Floor
11.2.1.1 : Brick partition wall in Cement Mortar 1:4 (One of cement and four of Crushed stone sand with Admixture) 70mm thick for super structure in the following floors using Fly ash bricks of size 230x110x70mm having the compressive strength of not less than 100 Kg/CM² for superstructure in the following floors a. In Stilt / Ground floor
b. In First Floor
12.1.1 : Brick partition work in C.M. 1:4 using country bricks of size 22 x11x5cm 50 mm thick (using crushed stone sand) a. In Ground floor
b. In First Floor
14.1.1.I : Precast Cupboard slab 20 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Stilt / Ground floor
b. In First Floor
14.1.1.II : Precast cupboard slab 40 mm tk using standardised concrete mix M20 grade.(using crushed stone sand) a. In Foundation & Basement
b. In Stilt / Ground Floor
c. In First Floor
15.2.1: Cuddappa slab 40 mm tk.for C/B slab. (using crushed stone sand) a. In Ground Floor
16.1.2 : Precast Jally Ventilator 50mm thick.Using standardised M20 grade concrete Mix. (using crushed stone sand) a. In Ground Floor
b. In First Floor
18.1 : Formwork using M.S.Sheet a. For Column footings, plinth beam, Grade beam, Raftbeam, Raft slab etc.,
b.Plain surfaces such as Roof slab,floorslab,Beams,lintels,lofts,sill slab,staircase,portico slab and other similar works
c.For Square and rectangular columns and small quantities
d.For Vertical wall
f.Curved Surface
g.Double centring for Garage
21.5.2 : Supply and fixing Solid UPVC door shutter with frame
21.5.5.1: Supplying and fixing of solid core flush door shutter of thickness 35mm a) Door size 1000mm x 2400mm (Single Leaf)
22.1.1: TW Double leaves panelled door shutter (Aluminium fittings with brass screws) a. 1500 x 2400mm.
22.2 : Teak wood glazed window and ventilators shutters 6.25 x 3.12cm styles and rails and 3mm thick ground or frosted glass for panels including labour charges and cost of furniture fittings as per schedule ‘E’ and as directed by the departmental officers. a) T.W. glazed single leaf for each bay to suit window frames of over all height 135cm.
22.3.3 : T.W. frame & T.W styles & rails with BWR double leaf shutters for Cup board/ward robes including two coat enamel paint & one coat primer.
23.1.1 : TW styles & rails with 9mm thick BWR single leaf shutters with brass screws a. 900 x 2400 mm
23.2.1 : 4mm thick pin headed Glass panels with Aluminium beedings
26.1 : Flooring in C.C.1:5:10 (using crushed stone sand)
28.1 : Floor plastering in C.M. 1:4, 20 mm tk. (using crushed stone sand) with plasticizer
29.8.1 : Glazed tiles using Grout (Tile Joint Filler) (using crushed stone sand)
29.9.1 : Floor ceramic tiles using Grout (Tile Joint Filler) (antiskid) (using crushed stone sand)
32.1.1: Finishing top of roof with one course of Hydraulic Pressed Tiles of approved superior quality of size 23cmx 23cmx20mm thick laid over weathering course in cm 1:3 (One of cement and three of crushed stone sand) 12mm thick mixed with Water proofing compound at 2%
33.1 : Plastering in C.M. 1:5, 12 mm tk. (using crushed stone sand) with plasticizer
34.1 : Plastering in C.M. 1:4, 12 mm tk.(using crushed stone sand) with plasticizer
35.1.1 : Plastering 1:3, 12mm with WPC (using crushed stone sand)
35.1.2 : Spl. Ceiling plastering in C.M. 1:3, 10 mm tk. (using crushed stone sand) with plasticizer
36.1 : Cement mortar Border in C.M. 1:5, 12 mm tk. (using crushed stone sand) a. 150 mm wide
b. 75 mm wide
c. 50 mm wide
38.6 : One coat white cement for new walls and other similar works.
38.7 : Plastic Emulsion PAINT including primer for inner walls
38.7.1 : Plastic Exterior Emulsion PAINT including primer for outer walls
43.1 : Supply & Fabrication of Mild steel / RTS grills (without cement slurry) for all sizes of rods.
44.2.1 : Rain water harvesting using defunct borewell and providing perforated cover slab a). Providing pit (M20)
b) Augering 30cm dia
44.6 : PVC SWR 110 mm dia with ISI mark type- A for Rain water down fall pipe
50.2.1 : Providing precast Kerb stone in C.C. 1:3:6, 450 x 300 x 150mm (using crushed stone sand)
50.5.1 : Supplying. Fabricating and erection of M.S Scheme Name board (using crushed stone sand)
50.6.1 : Precast slab 50 mm tk.in C.C. 1:3:6 with fibre (using crushed stone sand)
53.4 : S&F of C.I Manhole cover 60 x 60 cm (50kg weight )
53.5.2 : Wash Hand Basin of size 550 x 400 mm (White without Pedestal)
54.1.1 : S & F of 15mm dia half turn CP long body tap
54.2.1 : S & F of 15mm dia half turn CP short body tap
56.3.1: S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - In G.F.(using crushed stone sand)
56.4.1 : S&F of Indian Water Closet white glazed (Oriya type) of size 580 x 440mm with PVC SWR grade P' or "S' trap - Other than G.F.(using crushed stone sand)
57.1.2 : S & F of E.W.C (White) 500mm with PVC SWR grade "P" or "S" Trap (using crushed stone sand)
58.3 : PVC SWR pipe (Soil line) with ISI mark - type 'B'. a. 110 mm dia.
b. 75 mm dia.
58.4 : Supplying, Laying & Concealing the 50mm dia PVC ( SWR) pipe with ISI mark type - 'B' with relevant specials.
58.5 : PVC (SWR) pipe with ISI mark - type 'A' for Ventilating shaft with cowl
60.1 : PVC Nahani trap (4way/2way)
61.3 : UPVC Non Pressure pipe of SN8 SDR 34 (S 16.5) as per IS 15328/2003 a. 110 mm UPVC Non Pressure pipe
b. 160 mm UPVC Non Pressure pipe
62.1.1 : PVC Specials as per IS 10124/1982 Part II a. 110 mm dia PVC bend
b. 160 mm dia PVC bend
62.2.2 : PVC Equal Tee as per BIS 7834/1975 a. 110 mm dia PVC Equal tee
b. 160 mm dia PVC Equal tee
64.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990. a. Light point with ceiling rose
b. Light point without ceiling rose
c. Calling bell point with Buzzer/Calling bell
65.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Fan point.
66.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for Staircase Light Point.
67.1 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Switch Board Itself.
68.2 : Wiring with 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990 for 5 amps 5 pin plug socket point @ Convenient Places.
71.2: Supplying and fixing of 32Amps triple pole main switch with fuse and neutral link
75.1.2 : Supply and delivery of 48" (1200 mm) Fan with ISI mark with Eletronic Dimmer
77.5 : Run of 2 Wires of 1.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
77.7 : Run of 2 Wires of 2.5 sqmm PVC insulated single core multi strand fire retardant flexible copper cable with ISI mark confirming IS: 694:1990.
79.1.1: 1 No. of 32 amps fuse unit
79.2.1: 3 Nos. of 32 amps fuse unit
85.1 : Supply of G.I pipe 40mm dia 'B' Class
87.1: Supplying and delivery of Three phase ELCB/RCCB
90.1: Providing additional strutting to centering of plain surface
98.5.4.1: TW Panelled door shutter with brass fittings (Double leaf) a. 1200mm x 2400mm.
98.5.4.2: TW Panelled door shutter with brass fittings (Double leaf) a. 1800mm x 2400mm.
105.1 : 4 x 4 Sq mm copper PVC insulated unsheathed single core cable for 3 phase EB service connection.
112.1 : S&F of 225 mm dia sweep AC exhaust fan
344.2 : S&F of Bevelled edge mirror 500 x 400 x 5.5mm
361.1 : Concrete designer tiles flooring (using crushed stone sand)
361.5.1: Vitrified Tiles flooring (ivory) incl. pointing (using crushed stone sand)
448.2: Supply and fixing 32mm dia PVC Tee with end cap
ANNEXURE-II: A1: Providing Rain Water Harvesting well ring circular shape of 90cm dia, 60cm depth, 50mm thick using M20 grade concrete including steel fabrication.
A2: Supplying, delivery and fixing of 83mm tk rubber moulded hydraulic pressed paver block including conveyance charges, laying of 83mm thick paver block
A3: Supplying and fixing of LED bulbs suitable for fixing it to pendent / bakelite battern holder of best approved variety a) 9 watts LED bulb
b) 12 watts LED bulb for bulk head fittings
A4: Supplying and fixing of 18W LED TUBE LIGHTS 4' long with necessary fittings and charges for assembling and fixing
A5: Supply and fixing of LED Bulk head fitting for 12W LED Bulb
A6: Supplying and fixing of 25W LED Street light with necessary fittings (Superior variety) Charges for fixing 25W LED lamp street light fittings
A7: Drilling of 6" dia (150mm) vertical bore well in Overburden soil including labour charges for insertion of casing pipe in the scheme area to required depth etc., all complete and as directed by the departmental officers.
A8: Drilling of 6" dia (150mm) vertical bore in hard rock areas anywhere in Tamil Nadu including transportation to the worksite in hard rock areas and developing the borewells etc., all complete and as directed by the departmental officers. a) Up to 150m below Ground Level
b) From 151m up to 180m
c) From 181m up to 210m
d) From 211m up to 240m
e) From 241m up to 250m
A9: Supplying, delivery and fixing of 160mm dia PVC casing pipe 6kg/cm2 of approved quality with ISI mark conforming to IS specifications as per IS 12818/1992 for borewell with average wall thickness of 6.10mm and with inner/outer threaded ends at standard length etc.,
A10: Supplying and fixing of 160mm dia PVC end cap for borewell of best approved quality with ISI mark conforming to IS specifications including cost of materials conveyance to site and labour charges for fixing in position etc., all complete.
A11: Supply and delivery of clear water vertical wet type 5 HP submersible pumpset without panel board suitable for 150mm dia borewell conforming to IS 8034/2002 as amended thereafter and BEE 3 Star Rated capable of discharging noted LPM against head of water column due to all causes. Duty - 50 lpm x 175m
A12: Supply and delivery of 2 HP Open well Submersible pump set without panel board conforming to IS 14220 /2002 and as amended thereafter and BEE 3 Star Rated capable of discharging the following duties due to all causes. Duty - 50 lpm x 75m
A13: THREE PHASE PANEL BOARD- D.O.L WITH TWO LEVEL GUARD AND AUTO START Supply and delivery of direct online starter confirming to IS13947, IEC60947-1 and as amended thereafter with suitable KW rating for operation in AC/Three Phase/50HZ(± 5%) and 415 V(±10%) For 5 HP
A14: Labour charges for the erection of submersible pumpset in borewell / openwell including fixing and jointing submersible cable with proper clamps upto the starter. Upto 5 HP
A15: Supply and delivery of 3 core 4 sqmm 1100V grade copper UG flat cable of best and approved quality having ISI mark etc., all complete.
A16: Supply & laying of 32mm dia UPVC - Column pipe approved quality with ISI mark
A17: Supply and delivery of Nylon rope of best and approved quality for tying the delivery line with submersible pumpset for safety measure etc., all complete.
A18: Supplying, laying, fixing and jointing the following PVC pipe as per ASTM-D-1785 of schedule 40 including cost of materials and labour charges for earth work excavation, laying, jointing and cost of conveyance charges with necessary specials etc., all complete and as directed by the departmental officers. (Below Ground level). a) 50mm dia PVC pipe (Bore to Sump line)
A19: Supplying and fixing of MS angle of size 50 x 50 x 12.5mm MS angle to hold LTUG cable in OH portion etc., all complete and as directed by the departmental officers.
A20: Supply and delivery of 3.5 core 50 sqmm PVC armoured UG Cable with ISI mark of best approved quality etc., all complete and as directed by the departmental officer.
A21: Labour charges for conveying and laying of UG cables in the cable trench including earth work and providing sand cushion with brick layers below ground level etc., complete for UG cable of size 4 to 95 Sq.mm and 2, 3, 3.5, 4 core with ISI Mark etc., all complete and as directed by the departmental officers.
A22: Supply and frxing of brass cable gland for 3.5 x 50 sq.mm. PVC armoured LTUG cable with earth connection etd., all complete and as directed by the departmental officers.
A23: Supplying of 25 mm dia PVC rigid pipe 10 Kg/cm² including all specials etc., completed for casing pipes for 4.0 sq mm submersible flat cable and as directed by the departmental officers.
A24: Supplying and delivery of 40mm dia PVC pipe 10 Kg/cm² etc., all complete and as directed by the departmental officers.
A25: Supplying and delivery of following dia GI, GM, CI, PVC and MS specials of best and approved quality having ISI mark etc., all complete and as directed by the departmenal officers. (The qualiy of the GI, GM & UPVC specials should be got approved by the Executive Engineer before use) a) 32mm dia GI Union
b) 40mm dia GI Union
c) 40mm dia GI Elbow
d) 50mm x 40mm dia GI Reducer
e) 40mm dia GI Bend
f) 32mm dia GI Bend
g) 50mm dia GI Bend
h) 40mm dia GI Tee
i) 40mm dia GI Coupling
j) 32mm dia GI Hex Nipple
k) 40mm dia GI Hex Nipple
l) 50mm dia GI Gun metal Valve
m) 40mm dia Gun Metal Foot Valve
n) 50mm dia Gun Metal Non Return valve
o) 50mm dia UPVC MTA
p) 50mm dia UPVC FTA
q) 40mm dia PVC MTA
r) 40mm dia PVC FTA
s) 40mm dia Gun Metal Gate valve (Heavy Duty)
t) 32mm dia Gun Metal Gate valve (Heavy Duty)
A26: Supplying, laying, fixing and jointing the following UPVC pipe as per ASTM-D-1785 of schedule 40 including cost of materials and labour charges for earth work excavation, laying, jointing and cost of conveyance charges with necessary specials etc., all complete and as directed by the departmental officers. (Below Ground level). a) 40mm Dia UPVC pipe below GL
A27: Supplying and fixing of 40mm dia Cast Iron Adopter with ISI marks of best quality etc., all complete and as directed by the departmental officers.
A28: Supplying and laying of GI pipe "B" class with ISI mark for above ground level including cost of clamping and labour charges, fixing GI pipes etc complete, all complete and as directed by the departmental officers. a) 50mm dia GI 'B' class pipe
A29: Supplying and fixing of following size of Aluminium Dye casting letters with MRF Powder Coating including labour charges for fixing in position cost and conveyance of all materials, T.W plugs, screws metal paste and labour charges etc.,. a) 9" size Aluminium Dye casting letters
b) 12" size Aluminium Dye casting letters
c) 60cm (24") size TNPHCL logo
A30: Supplying and fixing of 15" size TNPHC Emblem (Tamil Stainless Steel letters) including cost of emblem & letters and labour charges for fixing with necesssary Scaffolding etc., all complete and as directed by the departmental officers.
A31: Supplying and fixing of RCC precast Exhaust fan collor including delivery at site and labour for fixing in position etc., all complete.
A32: Supplying and fixing of Plastic name board of size 60 cm X 10 cm (24"x4") with Stikness cut in computer to the depth including cost & fixing charges etc., all complete.
A33: Supplying and fixing 3 Nos 100 Amps 500 volts grade/ well porcelin fuse unit on suitable teak wood plank
A34: Supply and fixing of brass cable gland for 3.5 x 25 sq.mm. PVC armoured LTUG cable with earth connection
A35: Supply and providing cable end termination of 3.5 x 50 sq.mm. PVC LTUG aluminium armoured cable with necessary aluminium cable sockets by crimping etc with electrical connection complete
A36: Supplying and fixing of Single Pole 6A to 32A, 10KA MINIATURE CIRCUIT BREAKERS 240 V / 415V 50HZ - AC Supply suiatble for both lighting and motor circuits etc., all complete and as directed by the departmental officers.
A37: Supplying and fixing 50mm dia M.S. Clampset with ISI mark etc., all complete and as directed by the departmental officers.
A38: Supplying and fixing of 500 watts Focus light fittings including cost of material and labour charges for fixing of light etc., all complete and as directed by the departmental officers. (The brand shall be got approved from the Executive Engineer before use)
A39: Supplying and fixing of 250 watts sodium vapour lamp fittings including cost of material and labour charges for fixing of light etc., all complete and as directed by the departmental officers. (The brand shall be got approved from the Executive Engineer before use)
A40: Supplying and fixing of 12" dome light fittings and 9 watts LED bulb including cost of material and labour charges for fixing of light etc., all complete and as directed by the departmental officers. (The brand shall be got approved from the Executive Engineer before use)
A41: Supplying and fixing of Spot light fittings and LED bulb including cost of material and labour charges for fixing of light etc., all complete and as directed by the departmental officers. (The brand shall be got approved from the Executive Engineer before use)
A42: Supply and fixing of 900x700x250mm thick EB service panel for 415 Volt, 3 Phase, 4 wire 50 hz power distrbution system.the panel shall be indoor wall mouting type out of 16 swg sheet steel complete with all accessories. in comng 1 No. 300 Amps bus bar compartment and separate energy meter compartment outgoing 3 Nos. 300 Amps fuse with base includng all necessary connection etc.. all complete and as directed by the departmental officers.
A43: Supply and fixing of 32 Amps double pole main switch on teakwood board top mes service connection / Motor Pump set (Single Phase) etc.. all complete and as directed by the departmental officers.
A44: 7 SEGMENTS (3 TIER) 3 PHASE DISTRIBUTION BOARD WITH MCB 4 way / 6 way / 8 way / 12 way TPMCB sheet steel distribution boards flush type / surface type fitted with bus bars and neutral links with single / three phase MCB outgoings and separate 4 way provision for accommodating One No. 4 pile incoming MCB / Isolator and another separate 4 way provision for accommodating One No. 4 pole ELCB / RCD (totally 8 ways in one segment) (3 x 4 ways in each segment) and separate provisions for MCB / Isolator (totally 12 Nos.) for sub incomers in 3 segments with label holder and provisions for taking up cable for size not less than 35 sq.mm. TPMCB DB with Metal / Acrylic Door Cover with IP42 Pro- tection - HIGHER END 4 ways 3 phase DB No. of ways incomer MCB / Isolator - 4 No. of ways incomer ELCB / RCD - 4 No. of sub-incomers - 12 No. of outgoings ways - 12
A45: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free.
A46: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free.
A47: Geologist Survey Charges
ASR CONSTRUCTIONS (BID ID -1263823)
LGN CONSTRUCTION (BID ID -1272391)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_630842.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .