Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.0 LAccepted-AOC B 134 GANESH MURTHI NAGAR PART III COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | ₹31.0 L Quoted ₹33.0 L | L1 | Accepted-AOC Lowest one |
| 2 | L2₹34.1 L+₹1.2 L (3.51%)Rejected-Finance ROOM NO 145 MASJID WALI GALLI GANESH MURTI NAGAR PART NO 2 COLABA MUMBAI 05 | ₹34.1 L+₹1.2 L (3.51%) | L2 | Rejected-Finance Other than lowest one |
| 3 | L3₹35.9 L+₹2.9 L (8.85%)Rejected-Finance | ₹35.9 L+₹2.9 L (8.85%) | L3 | Rejected-Finance Other than lowest one |
| 4 | L4₹43.4 L+₹10.4 L (31.6%)Rejected-Finance | ₹43.4 L+₹10.4 L (31.6%) | L4 | Rejected-Finance Other than lowest one |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
10 Jul 2021, 6:00 pmClosed
GE NW NOFRA
GE NW NOFRA DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIRS REPLACEMENT AND MAINTENANCE OF UNSERVICEABLE CEILING FAN EXHAUST FANS GEYSERS INCLUDING ELECTRIC WIRING WITH MCB DBS FOR RESIDENTIAL AREA UNDER OUTLYING AREA OF GENW NOFRA COLABA MUMBAI
2021_MES_451109_1
8912
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
Mumbai
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE NW NOFRA
₹80,000
Yes
21 Jan 2022
15 Jun 2021
15 Jul 2021
15 Jun 2021
10 Jul 2021
28 Jun 2021
15 Jun 2021 - 26 Jun 2021
Amount
Material & labour for unscrewing body parts of fans of any make/brand and description and opening of the stator & rotor of following sizes of fans and taking out down rod canopy, shackle, condenser housing with rubber reel bushes,ball bearing,metal bush and carry out repairs all as directed by Engineer-in-charge and as required as under:- (a) M&L for opening the stator & rotor of the 1200mm / 1400 mm sweep ceiling fan cutting the exsisting worn winding & rewinding the fan with superior quality rewinding wire & filling the warnish as insulation between each winds & covering each loops of winding by sleeves & paper & reassembling of complete fan by fixing servicable old and new parts of fans i.e. rubber bush of condensor & shackle housing , condensor, gun metal bushes,ball bearings twin twisted copper cable down rod assembly with its shackle condenser housing & canopy ,split pins complete all as per manufacturers design air delivery including greasing,oiling & testing of fans all as per manufacturers design & speed complete all as directed by Engineer in charge
Notes for item No 1.00 :- (i). The quoted unit rate shall be deemed to be inclusive of taking out defective parts and fixing of new parts. All new parts shall be measured and paid vide relevant items of the schedule. (ii). The rates for refixing & taking out servicable parts shall be deemed to be included of quoted unit rates. (iii). New parts shall be of respective makes of fans. (iv). The quoted unit rates shall also include writing of MES No of fans (v). Unservicable / defective retrived parts shall be credited vide sch of creidt. (vi). After assembling all fans shall be tested for the speed as directed. (vii). All the fans are laying in store yard of AGE E/M and shall be repaired at store yard only.
(b) All as per srl item No 1.00 here-in-before but for air wall mounting fans
(c) All as per srl item No 1.00 here-in-before but for Exhaust fans of 225 / 250mm / 300 mm sweep
(d) All as per srl item No 1.00 here-in-before but for Exhaust fans of 450 mm sweep
Supply & Fix in repair elctronic Fan regulator 450 watt step type heavy duty complete all as specified and directed by engineer in charge.
Supply and fix in repair GI 'U' clamp heavy duty rubber reel of superior quality and nut and bolts with locking arrangement complete all as specified and directed by engineer in charge.
Supply only PVC canopy cover superior quality complete all as specified and directed by engineer in charge.
M&L for cleaning the fan motor assembly body,blade of ceiling fan, filling the cavity & painting with existing colour of the ceiling fan with one coat of superior quality synthetic enamel paint by spraying appratus and spraying process including writing the MES number on the ceiling fans of 1200mm /1400 mm sweep with black colour synthetic enamel paint complete all as specified and directed by engineer in charge.
M&L for cleaning the fan motor assembly body,blade of Exhaust fan, filling the cavity & painting with existing colour of the Exhaust fan with one coat of superior quality synthetic enamel paint by spraying appratus and spraying process including writing the MES number on the Exhaust fans of 225/250mm/ 300 mm sweep with black colour synthetic enamel paint complete all as specified and directed by engineer in charge.
Supply only bearing No 6201 for 1200/1400mm sweep ceiling fans complete all as specified and directed by engineer in charge. Make NBC, SKF , equivalent as approved by GE.
Supply only bearing No 6202 for 1200/1400mm sweep ceiling fans complete all as specified and directed by engineer in charge. Make NBC, SKF , equivalent as approved by GE.
Supply only capacitor 2.5 MFD dry type complete all as specified and directed by engineer in charge. Make: Amcap , Epson , equivalent as approved by GE.
Supply only capacitor 4.0 MFD dry type complete all as specified and directed by engineer in charge. Make: Amcap , Epson , equivalent as approved by GE.
Supply only gun metal bush suitable for 1200/1400mm sweep ceiling fan complete all as specified and directed by engineer in charge.
S&F Clamp nut , bolt incliding safety pin for ceiling fan including taking down old pin complete all as specified and directed by engineer in charge.
S&F modular fan regulator step type electronic of capacity 300/450 watt working on 230 Volts including taking down old one complete all as specified and directed by engineer in charge.
Taking down old unserviceable rusted extaust fan shutter and supply and fixing shutter of size 255 to 450 mm sweep complete all as specified and directed by engineer in charge.
Making round/ squar hole cutting in the kitchen wall with the help of cutting machine / chisel / hammer etc for fixing of exhaust fan of size 225 mm to 300 mm & making good to the distrubed surface including plaster, distumper , white wash complete all as specified and directed by engineer in charge.
Checking serviceability of all ceiling fans/ exhaust fan in each quarter and checking clamps nut, bolts, pins are in healthy condition If any problem in any items will be note down by electrician and informed concerned JE E/M and rectify the problem next day complete all as specified and directed by engineer in charge. Note : All the items will be paid separately
Supply and fixing the ceiling fans complete with blades, down rods, electronic regulator and accessories , 230 volts , 1200 sweep. Min air delivery 210 CFM with service value 6.0 BEE. Five star rated with brushles direct current motor and fixed to ceiling and connecting up including provision of flexible 3 core copper cable and testing smooth functioning at site complete all specified and directed. Make : Havells / Orient / Philips Note : a) The ceiling fans consider against BER. b) Old fan shall be deposited to the MES store as directed by Engineer in charge.
M&L for stopping the leakage of the geyser by applying brazing to inner tank and refixing the inner tank after making it functional all as specified and as directed by engr-in-charge. Note : Adeuqate water pressure will be apply to the brazed tank to ensure that no leakage is left if the tank leaked the same will be repaired by the contractor witout claiming any additional cost from the department.
S&F in replacement of heating element as required at site of 1.5 KW ISI marked as required at site and approved by Engr-in charge. Make: CG,Havells,Racold as approved by GE.
S&F in replacement of heating element as required at site of 2.0 KW ISI marked as required at site and approved by Engr-in charge. Make: CG,Havells,Racold as approved by GE.
S&F in replacement thermostat switch for geyser of any type ISI marked complete all as specified and directed by engineer in charge.
S& F in replacement geyser inner tank assembly suitable for geyser capacity of 25 Ltr complete all as specified and directed by engineer in charge.
S& F in replacement geyser inner tank assembly suitable for geyser capacity of 50 Ltr complete all as specified and directed by engineer in charge.
S&F in replacement inner tank for geyser of 06 Ltr capacity complete all as specified and directed by engineer in charge.
S&F in replacement inner tank for geyser of 03 Ltr capacity complete all as specified and directed by engineer in charge.
S&F CP in replacement non return valve 15mm bore with air lock relase arrangement ISI marked complete all as specified and directed by engineer in charge.
S&F in replacement metal clad socket top of any make suitable for fixing on existing metal clad socket complete all as specified and directed by engineer in charge. Note: Metal clad plug of any make as required at site will be provided.
S&F in replacement of glass wool for geyser of 25/50 ltr complete all as specified and directed by engineer in charge.
S&F in replacement of inspection cover stainless steel in 2 piece suitable for gesyer of 50/25 ltr capacity and having provision of fixing indiactor lamps complete all as specified and directed by engineer in charge.
S & F in replacement PVC insulated 3 core circular stranded copper conductor of 2.5 sqmm complete all as specified and directed by engineer in charge. Make: Havells,Finolex,Polycab as approved by GE.
S&F CP gate valve of 15 mm bore suitable for fixing on existing fittings complete all as specified and directed by engineer in charge. Make: Leader , Zoloto , Sant as approved by GE.
S&F in replacement brass connection 15mm bore pipe 1.5 feet to 2.5 feet having wire mesh coating over it with PTMT nuts and washers suitable for connecting geysers inlet and outlet with GI tubings complete all as specified and directed by engineer in charge.
S&F in replacement GI tubing med grade 15 mm bore with all fittings as required at site i.e. elbow,socket,nipple reducer & union as required for plumbing work and making connection as required at site all as specified and as directed by engr-in-charge. Note: Rate quoted shall also include the plumber work as per site requirements.
S&F in replacement of top plug 15 Amp 3 pin complete all as specified and directed by engineer in charge. Make: Anchor,Plaza,CG as approved by GE.
S&F in replacement of MCB 16/20 Amp Sp 'C' curve 230 Volts complete all as specified and directed by engineer in charge. Make:Legrand / Scheinder / GE as approved by GE.
S&F in replacement of plug & Socket enclosure 16 /20 Amp including one 16/20 Amp MCB SP complete all as specified and directed by engineer in charge. Make:Legrand / Scheinder / GEas approved by GE.
S&F in replacement indicating lamp green/red in colour 230 volts complete all as specified and directed by engineer in charge.
S&F of NRV as per existing sample of instant geyser 03 ltr / 06 ltrs complete all as specified and directed by engineer in charge.
Supply & Fixing 3 inch / 4 inch long 12 mm to 20 mm dia including bolt , pin , washer complete all as specified and directed by engineer in charge.
Taking down old unserviceable geyser and deposited to MES store as directed by engineer in charge and fixing only new geyser of capacity 25 ltr to 50 ltrs including transporting both side from MES store to Qtrs by the contractor and geyser collected from MES store.
Taking down carefully aluminium point wiring (light, fan, socket or power) complete, (fittings such as switches, ceiling roses, pendants, regulators sockets etc to be measured separately) and making good disturbed surfaces of walls, floors, etc. complete all as specified and directed by engineer in charge.
Material and Labour for point wiring complete with 1.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC pipe of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement , ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes/ modular boxes surfacing on wall including one FRLS PVC insulated & sheathed multistranded green colour copper conductor 1.5 sqmm as earth continuity conductor connected to common earth as earth dolly for :-
(a) One light point controlled by one switch SP one way.
(b) One ceiling fan point controlled with one 5A switch
(c) One exhaust fan point controlled with one 5A switch
(d) One 3 pin socket outlet 5Amps on independant board.
(e) One 3 pin socket outlet 5Amps on same board with other switches.
(e) One 3 pin socket outlet 15 Amps on same board with other switches.
Material and Labour point wiring for Geyser /AC complete with 4 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC pipe of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly.
Material and Labour point wiring for 15 Amps socket complete with 2.5 sqmm single core multistranded FRLS PVC insulated unsheathed copper conductors 1100 volts grade drawn through and including PVC pipe of size not less than 20 / 25 mm dia including PVC bend, tee joints etc as per site requirement, ISI marked with accessories fixed on wall/ceiling/truss etc with PVC non metallic ISI marked terminal boxes / modular boxes surfacing on wall including one FRLS PVC insulated & unsheathed multistranded green colour copper conductor 4 sqmm as earth continuity conductor connected to common earth as earth dolly.
Supply and fix Modular Switch, 6Amp, One way, 1 module complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix support function blank plate single, 1 module complete all as specified and directed by engineer in charge.
Supply and fix Modular type, electronic fan regulator (5 step), 450 Watts, 230 volts, 2 module complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix ceiling rose surface bakelite with ISI mark, flush type with ISI mark three terminals complete all as specified and directed by engineer in charge.
Supply and fix Modular Socket oulet, 6 Amps, 2/3 pin combined, 2 module complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix Modular Socket oulet, 6/16 Amps, 2/3 pin combined, 2 module complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (NIXON).
Supply and fix Modular white cover plate with Frame 2 Module complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular white cover plate with Frame 3 Module complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular white cover plate with Frame 4 Module complete all as specified and directed by engineer in charge. Make : Legrand(Arteor), Havells(Coral) , Anchor(Ave) .
Supply and fix Modular white cover plate with Frame 6 Module complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 2 module including cutting and chassing complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 3 module including cutting and chassing complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 4 module including cutting and chassing complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix Modular metal flush box 6 module including cutting and chassing complete all as specified and directed by engineer in charge. Make : Legrand (Arteor)/Havells (Coral)/Gold Medal Electrical Pvt Ltd (WEGA)
Supply and fix baton intergrated LED channel 1x20WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by engineer in charge. Make : Havells/Philips/Jaquar as approved by GE.
Taking down old unserviceable submain cable of any size and capacity and finishing wall surfaces complete all as specified and directed by engineer in charge.
Supply and fix submain wiring in repair with two single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 4 Sqmm in and including PVC casing caping /conduit of suitable dia 20 and 25 mm, ISI marked including 1 single core cable with stranded copper conductor of size 4 sqmm (green colour) for earthing. Make : Polycab, Havells, Plaza, Note :- (i) Two runs of 4Sqmm cable, 1 run of PVC casing & caping and 1 run of 4 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC conduit/ casing and caping as per site requirment
Supply and fix submain wiring in repair 2 single core FRLS unsheathed 1100 volts grade cable with stranded copper conductor of size 6 Sqmm in and including PVC casing caping /conduit of suitable dia 20 and 25 mm, ISI marked including 1 single core cable with stranded copper conductor of size 06 sqmm (green colour) for earthing. Make : Polycab, Havells, Plaza as approved by GE. Note :- (i) Two runs of 06 Sqmm cable, 1 run of PVC casing caping and 1 run of 06 Sqmm cable shall be measured as 1 RM. (ii) Each submain wiring shall run in seperate PVC conduit/ casing and caping as per site requirment
Supply and fix sheet metal enclosure 12 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed by engineer in charge of comprising of the following :- Make: ABB, Standard , Legrand as approved by GE.
Supply and fix sheet metal enclosure 8 way Double door type having protection IP-42, with 200 Amps rated bus bar connecting with existing wiring circuits by providing copper pin terminals of suitable size complete all as specified and directed by engineer in charge of comprising of the following :- Make: ABB, Standard , Legrand as approved by GE.
(a) MCB SPN 63 Amps, 240 Volts - 01 No Make - Legrand /Standard/ Havells
(b) MCB SP 6-32 Amps, 240 Volts - 10 Nos Make - Legrand /Standard/ Havells
Supply and fix in repair PVC Box for Switches, with fixing accessories complete of the following sizes :-
(a) -do- but size 4”x4”
(b)-do- but size 4” x 7”
(c)-do- but size 6” x 8”
(d)-do- but size 10” x 8”
Supply and fix in repair LED lamp suitable for 14 watts, 240 volts, single phase, 50 Hz, Lumen 1450 AC supply complete all as specified and directed by engineer in charge. Make :Jaquar / Philips/ Havells as approved by GE.
Material and Labour in repair for Lamp holder, PVC /Polycarbonate type with cord grip cap suitable for pendant fittings complete all as specified and directed by engineer in charge.
Supply and fix baton intergrated LED channel 1x10 WH accessories internally prewired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed by engineer in charge. Make : Havells/Philips/Jaquar as approved by GE.
Supply and fix of One Bell point controlled by one bell push 5 amps independent board complete all as specified and directed by engineer in charge.
Supply and fix in replacement of modular type bell push 6 amps 1 module complete all as specified and directed by engineer in charge.
Supply and fix in replacement of bell electric AC 230 volt single pole ding dong with ISI mark complete all as specified and directed by engineer in charge.
CHOUDHARY ELECTRICAL
NOEL ENGINEERS
DHARMESH ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .