| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.3 CrAccepted-AOC VCC FARM HOUSE GALL NO 3 VIKAS NAGAR NEAR UNIQUE GARDEN MURTHAL ROAD SONIPAT 131001 | SONIPAT | SONIPAT | HARYANA | 131001 | ₹3.3 Cr | L1 | Accepted-AOC accept |
| 2 | L2₹3.3 CrRejected-AOC | ₹3.3 Cr | L2 | Rejected-AOC accept |
| 3 | L3₹3.4 CrRejected-AOC NA VILLAGE SUDKAIN KALAN DISTT JIND 125116 | SUDKAIN KALAN | JIND | HARYANA | 125116 | ₹3.4 Cr | L3 | Rejected-AOC accept |
| 4 | L4₹3.4 CrRejected-AOC | ₹3.4 Cr | L4 | Rejected-AOC accept |
| 5 | L5₹3.4 CrRejected-AOC | ₹3.4 Cr | L5 | Rejected-AOC accept |
| Sl No | Description | Qty | Unit | m/s omparkash contractor L6 | Ashi Construction Co L8 | Naveen L3 | V.P YADAV CONTRACTOR L4 | vedprakashcontractor L5 | VIDYA PROJECT PVT. LTD. L1 | JOGINDER SINGH CONTRACTOR L2 | M/s Balaji Construction Co. L7 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | CREDIT FOR STEEL OF OLD SLAB | 36.75 | cum | 1,800 -₹66,155.40 | 1,800 -₹66,155.40 | 1,800 -₹66,155.40 | 1,800 -₹66,155.40 | 1,800 -₹66,155.40 | 1,800 -₹66,155.40 | 1,800 -₹66,155.40 | 3,000 -₹1,10,259 |
| 2.00 | CREDIT OF OLD BRICK WORK | 129.06 | cum | 540 -₹69,690.78 | 540 -₹69,690.78 | 540 -₹69,690.78 | 540 -₹69,690.78 | 540 -₹69,690.78 | 540 -₹69,690.78 | 540 -₹69,690.78 | 1,025 -₹1,32,283.43 |
| 3.00 | Supply and carriage of stone from approved cuarry to site of work including all lead ,lifts and other equipments complete. | 253.43 | cum | 1,480 ₹3.8 L | 1,480 ₹3.8 L | 900 ₹2.3 L | 1,000 ₹2.5 L | 1,480 ₹3.8 L | 1,480 ₹3.8 L | 1,480 ₹3.8 L | 1,000 ₹2.5 L |
| 4.00 | Credit of RCC pipe | 52.49 | Metre | 5,455 -₹2,86,311.13 | 5,455 -₹2,86,311.13 | 15,000 -₹7,87,290 | 5,400 -₹2,83,424.40 | 5,455 -₹2,86,311.13 | 5,455 -₹2,86,311.13 | 5,455 -₹2,86,311.13 | 6,000 -₹3,14,916 |
Tender Value
₹4.4 Cr
EMD Value
₹8.8 L
Closing Date
7 Feb 2026, 6:00 pmClosed
MOHIT VASHISHTA
W.S. Divn. Palwal
existing bridge is in deteriorated condition
2026_HRY_498855_1
20260E2DA526 5F6A 4230 9417 4672FC356762164IRR
Open Tender
Civil Works
180 days
BANCHARI GAROTA
2 documents required · 2 mandatory
₹15,000
₹8.8 L
Yes
Palwal W.S. Division, Palwal
8 Apr 2026
23 Jan 2026
9 Feb 2026
23 Jan 2026
7 Feb 2026
23 Jan 2026
30 Jan 2026
CREDIT FOR STEEL OF OLD SLAB
CREDIT OF OLD BRICK WORK
Supply and carriage of stone from approved cuarry to site of work including all lead ,lifts and other equipments complete.
Credit of RCC pipe
Percentage BoQ
BoQ_Ver3.0
Name of the Bidder/ Bidding Firm / Company :
PRICE SCHEDULE (This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only )
NUMBER #
[15.1.2.2]Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom and backfilling with approved material as per clause 304 of MORTandH specifications Ordinary soil 2.2. Mechanical Means Depth 3 m to 6 m [Through Rate]
[6.22.2.2]Providing and laying in position ready mixed plain cement concrete, with cement content as per approved design mix and manufactured in fully automatic batching plant and transported to site of work in transit mixer for all leads, having continuous agitated mixer, manufactured as per mix design of specified grade for plain cement concrete work, including pumping of R.M.C. from transit mixer to site of laying and curing, excluding the cost of centering, shuttering and finishing, including cost of curing, admixtures in recommended proportions as per IS : 9103 to accelerate/ retard setting of concrete, improve workability without impairing strength and durability as per direction of the Engineer-in-charge. 2.2. All works up to Plinth Level : M-15 grade plain cement concrete. (cement content considered @ 240 kg/cum) [Through Rate]
[2.B0976] B0976. Empty Cement bags [Rate]
[27.1]Brick masonry work in 1:3 in sub-structure including scaffolding complete excluding pointing and plastering, as per drawing and MoRTandH Specifications 1300 and 2200 [Through Rate]
[27.51.3]Filler joint 3. Providing and fixing in position 20 mm thick premoulded joint filler in expansion joint for fixed ends of simply supported spans not exceeding 10 m to cater for a horizontal movement up to 20 mm, covered with sealant complete as per drawing and MoRT&H specifications. [Through Rate]
[27.16.2]Back filling behind abutment, wing wall and return wall complete as per drawing and MoRTandH Specification 710.1.4 of IRC: 78 and 2200. 2. Sandy material [Through Rate]
[27.15]Providing weep holes in Brick masonry/Plain/ Reinforced concrete abutment, wing wall/ return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1V :20H towards drawing force. Complete as per drawing and MoRTandH Specifications 2706 & 2200. [Through Rate]
[16.27]Filling cement bags with sand, sewing and laying in position within 30 metres in water including cost of strings by mechanical/ mannual means. [Through Rate]
[5.25]Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. [Through Rate]
[34.5.1]Cautionary sign board 600x600x600mm triangular as per IRC 67- 2012 with retro reflective Sheeting as per ASTM D 4956 09 and as per IRC 67 2012 fixed over 3 mm thick aluminium Composite material (ACM) sheeting having aluminium skin thickness of 0.4 to 0.5 mm on both sided and fixing the same with suitable size aluminium alloy rivets @ 200 mm c/c to back support frame of 25x25x3mm angle iron supported on a square hollow steel section post 60x60x3.2mm conforming to IS 4923 without cost of definition plate firmly fixed to ground in foundation concrete M-25 of size 0.45x0.45x0.75m for vertical post complete as per clause 801 of MORTandH specifications. Supplier shall provide a warranty as per clause 6.9 of IRC 67-2012 for retro reflective sheeting and a certified copy of test reports from an independent test laboratory including three year outdoor weathering test report for sheeting tested in India condition conforming to clause 6.7 of IRC 67-2012 1. Using retro reflective Sheeting Class C as per IRC 67 2012 [Through Rate]
[3.1.2]By Mechanical Transport including loading, unloading and stacking 2. Earth [3km]
[21.95.10]Providing lowering cutting jointing and testing RCC pipe class NP3 as per IS-458-2003 with spigot and socketed joints manufactured with ISI marked sulphate resistance cement as per ISI 12330 with rubber rings ISI marked antiternmite as required at site in to trenches for all depths and laying out the same to correct alignment gradients and levels including dressing and trimming and cutting of concrete beds and side of trenches, if required jointing with rubber rings in trenches and jointing with 1:3/2 cement sand mortar and with end dowels filled with 1:3/2 cement sand mortar and finishing the joints at an angle of 45 degree with faces of spigot of socket joints cutting and finishing the cut surface to a uniform finish etc. as fully described in item No. 21.38, item 21.44, item 21.45, and item 21.46 including cartage loading and unloading complete in all respects. the internal diametric of the sewer being: 10. 1200 mm [Through Rate]
[6.25.2]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 2. All works above plinth level up to floor IV level [Through Rate]
[7.21.2]Brick work with common burnt clay non-modular bricks of class designation 10.5 in foundation and plinth in: 2. Cement mortar 1:6 (1 cement : 6 coarse sand) [Through Rate]
[16.44.1]Filling stone or spalls by mechanical/ mannual means.- 1. on level [Through Rate]
[10.33.2]Providing and laying of brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 2. 1:6 (1cement : 6 coarse sand) [Through Rate]
[34.49]Painting Two Coats on New Concrete Surfaces Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces [Through Rate]
[6.29.1]Centering and shuttering including strutting, propping etc. and removal of form work for : 1. Foundations, footings, bases for columns [Through Rate]
[6.25.1]Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. 1. All works up to plinth level [Through Rate]
[6.29.3]Centering and shuttering including strutting, propping etc. and removal of form work for : 3. Columns, piers, abutments, pillars, posts and struts [Through Rate]
[6.33.6]Steel reinforcement for R.C.C. work, where not included in the complete rate of RCC, including straightening, cutting, bending, placing in position, binding, wastage, overlaps, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire etc. complete in all respect below plinth level Note: Reinforcement shall be measured in length including hooks, if any, separately for different diameters as actually used in work , excluding overlaps. Wastage, overlaps, couplings, welded joints, spacer bars, chairs, stays, hangers and annealed steel wire or other methods of binding & placing shall not be measured and cost of these items shall be deemed to be included in the rates for reinforcement. 6. Thermo-Mechanically Treated bars of grade Fe-500D or more [Through Rate]
[5.23.2]Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. 2. Nominal concrete 1:2:4 or leaner mix (i/c equivalent design mix) [Through Rate]
[5.7.4]Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. 4. In cement mortar [Through Rate]
[4.12.1]Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead up to 50 m and lift up to 1.5 m, as directed by Engineer-in-charge. 1. All kinds of soil [Through Rate]
[6.30.5]Centering and shuttering including strutting, propping etc. and removal of form for 5. Lintels, beams, plinth beams, girders, bressumers and cantilevers [Through Rate]
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
techsummary_577422.pdf
BOQ Comparative Chart
xlsx
finsummary_577422.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_577422.xls
BOQ • 0.36 MB
Download all tender documents and submit your bid