Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.0 LAccepted-AOC | L1 | Accepted-AOC Lowest quoted rate | |
| 2 | L2₹44.8 L+₹1.9 L (4.32%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest quoted rate |
Tender Value
₹49.4 L
EMD Value
₹98,880
Closing Date
10 Nov 2021, 6:00 pmClosed
Maj Pramod Kumar Tripathi
Military Engineer Services, Garrison Engineer (South) Ahmednagar - 414002
Special Repairs to TR Huts, Provn of Geysers, Exhaust Fans and Static Water Tank for STP at MIRC under GE(South) Ahmednagar
2021_MES_481387_1
8824/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
AHMEDNAGAR
Class D Cat a (i), b (i)
8 documents required · 8 mandatory
₹500
Garrison Engineer (S) Ahmednagar
₹98,880
Yes
29 Nov 2021
13 Oct 2021
12 Nov 2021
13 Oct 2021
10 Nov 2021
27 Oct 2021
13 Oct 2021 - 20 Oct 2021
Amount
Dismantling of kota stone slab, cudappah stone, lime stone etc of any description in floor, laid, bedded & pointed in any mortar, all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing complete all as specified and as directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n exc 15 cm thickness (below or above ground level) all as specified and as directed
Demolition of reinforced cement concrete in ground floors and paving n exc 15 cm thickness (below or above ground level) all as specified and as directed
Demolition of brickwork, built in cement mortar/ cement lime mortar including all quoins, arches, pillars,etc all as specified and as directed
Taking down chowkats or frames with shutters(without taking off shutters from frames), area n.exc 1.50sqm each and making good disturbed surfaces of wall in cement mortar (1:3) all as specified and as directed.
Taking down chowkhats or frames with shutters (without taking off shutters from frames), area exc 1.50sqm & n.exc 4.00sqm each and making good disturbed surface of walls in cement mortar (1:3) all as specified and as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and as directed.
Dismantling of AC sheet (corrugated, semicorrugated etc) in roof covering including ridges complete all as specified and as directed.
Dismantling plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings all as specified and as directed.
Taking up or down steel tubing and connections for 15mm bore including cleaning for refixing all as specified and as directed.
Taking up or down steel tubing and connections for 20mm bore including cleaning for refixing all as specified and as directed.
Taking down cement plaster of any description on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc all as specified and as directed.
Excavation over areas, n exc 1.5m deep and getting out in soft/loose soil all as specified and as directed.
Excavation over areas, exc 1.5m deep but not exc 3.0 m deep and getting out in any type of soil all as specified and as directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation, taking out pipe line etc for repairs / laying cables etc and getting out in soft / loose soil complete all as specified and as directed.
Returning filling in (soil), including spreading, levelling, watering and well ramming in layers n exc 25cm thick all as specified and as directed.
Removing excavated soil to distance n.exc 50 m and depositing where directed at a level n exc 1.5m above the starting point all as specified and as directed.
Removing excavated soil to distance exc 250 m but not exc 500m and depositing where directed at a level n exc 1.5m above the starting point all as specified and as directed.
M&L for moorum filling in floors or pavings, laid in layers n exc 15 cm thick, spread, levelled and rammed including watering all as specified and as directed..
M&L for hardcore of gauge exc 63mm but n exc 100mm, deposited, spread and levelled in layers n exc 15 cm thick, watered and rolled / rammed to a true surface all as specified and as directed.
M&L for PCC 1:4:8, type D2, using 40mm graded stone aggregate as in foundations filling and mass concrete all as specified and as directed.
M&L for RCC 1:2:4, type B1 using 20mm graded stone aggregates as in foundation, basement/ground floor slab etc all as specified and as directed.
M&L for RCC M-25 (Design mix) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs and mass concrete all as specified and as directed.
M&L for RCC M-25 (Design mix) as in walls, retaining walls and like, any thickness, mixing with water proofing compound @ 2% by weight of cement or as per manufacturers instruction all as specified and as directed.
M&L for RCC M-25 (Design mix) as in beams, cantilevers, bressummers, lintels over 1.50m span all as specified and as directed.
M&L for RCC M-25 (Design mix) as in slabs supported on walls, beams and column in floor, roofs, landings shelves etc all as specified and as directed.
Supply only integral water proofing compound, ISI marked as approved by GE all as specified and as directed
M&L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6, complete all as specified and as directed.
Use and waste of form work to sides of concrete foundations, footings etc and similar work for rough finished flat surfaces of concrete all as specified and as directed
Use and waste of form work to faces of concrete walls, retaining walls etc and similar work for rough finished flat surfaces of concrete all as specified and as directed
Use and waste of form work to sides and soffits of floor/roof beams etc and similar work for rough finished flat surfaces of concrete all as specified and as directed
Use and waste of form work to soffits of suspended slab, landing etc n exc 200 mm thick etc and similar work for rough finished flat surfaces of concrete all as specified and as directed
S&F 35 mm thick, second class hardwood, factory made, plain framed, panelled shutter (two panels) with panel of 9 mm thick BWP plywood bonded with high quality phenol formal dehyde synthetic resin adhesive confirming to IS-710. the size of rails & style shall be as per IS -1003 (Part I) kiln seasoned as per IS -1141 & chemically pressure treated as per IS-401 complete all as specified and as directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube and fixing in opening all as specified and as directed.
S&F factory made solid PVC moulded door shutter with particle board core, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick moulded prelam PVC sheet on the front face and 2mm prelam PVC sheet on back face and in frame all as specified and as directed.
S&F mild steel butt hinges, medium weight, colled rolled ISI marked of size 100mm complete all as specified and as directed.
S&F 300 mm long rat helical tail door spring including roller and roller plate complete all as specified and as directed.
S&F aluminum anodised barrel tower bolt 150 mm long of extruded section & fixed complete all as specified and as directed.
S&F aluminum handle 125 mm long, fabricated type anodised all as specified and as directed.
S&F 250mm in long, aluminium sliding door bolts with hasp, staple (bolt type) and fixing clips of sheet cast or extruded sections and fixing bolts and sliding bolts of extruded section, complete all as specified and as directed.
S&F in repairs for galvanised mild steel wire cloth 0.56 mm nomonal dia of wire & average width of aperature 1.18 mm & fixed with wooden beads / tinned tacks or galvanised wire staples to steel / wooden frame all as specified and as directed.
S&F galvanised iron netting mesh, 0.90mm dia and 12mm aperature fixed to walls, ceiling etc including all laps complete all as specified and as directed.
S&F mild steel TMT bars 10mm dia and over as reinforcement for concrete, cut to length, bent to shape required, including cranking, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia all as specified and as directed.
S&F rolled mild steel plates (plain or chequred) channels, square cut or notched, forming holes, with riveted, bolted or welded attachment confirming to Fe 410 - O or Fe 310 - O all as specified and as directed.
S&F rolled mild steel sections in roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.(Fe-410-W(Gde-E-250) quality- B all as specified and as directed
Fabrication and errection only, rolled mild steel sections in roof trusses (framed), trussed,purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc all as specified and as directed. Note : Usable mild steel sections obtained from dismantling under item No 8 shall be re-used.
M&L for pressed steel frames of size 105mmx60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate etc complete all as specified and as directed.
M&L for 0.63mm thick, plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 all as specified and as directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls fixed with L-type or J-type or cranked hook bolts complete as all as specified and as directed.
M&L for 6mm thick asbestos cement, corrugated or semi-corrugated sheets in roofs, walls fixed with L-type or J-type or cranked hook bolts complete but except sheets as all as specified and as directed.
S&F 12mm thick gypsum board in ceiling, fixed with screw/clips, including Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flangesof 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre including dismantling existing old false ceiling boards with framework and necessary fixing/ repair /replacement of existing electrical fittings at site all as specified and as directed.
M&L for 75mm thick PCC 1:3:6, type C2 (using 40mm graded stone aggregate) as in plinth protection, etc finished the surface even and smooth without using extra cement including provision of joint of size 10 mm wide & 10 mm deep and filling with bitumen mastic joint filling at every 3m length and at corners complete all as specified and as directed.
M&L for glazed coloured ceramic tiles 7mm thick (plain or printed), area of each tile exc 0.11 sqm but n exc 0.18 sqm, shade as approved by GE, as on vertical surfaces like dado, skirting etc laid over and including 10 mm thick backing coat in cement mortar 1:4, jointed in neat cement slurry and pointed in coloured cement to match with colour of tiles complete all as specified and as directed.
M&L for non-skid coloured ceramic tiles 7 to 8 mm thick (square/ rectangular), area of each tile exc 0.06 sqm but not exc 0.11 sqm, shade as approved by GE, as in floors etc., laid over and including 15 mm thick screed bed in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles complete all as specified and as directed.
M&L for 20-25mm thick machine cut cudappah stone slab laid over and including 20mm thick cement screed in cement mortar 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
M&L for machine cut kota stone flooring, 20-25 mm thick (size of kota stone slab 22"x22") laid over and including 20 mm thick bedding layer of cement mortar 1:6 jointed with grey cement slurry mixed with pigments to match the shade of slab including cutting, rubbing and mirror polishing including removing dust complete all as specified and as directed.
All as per serial item No. 57 here-in-before but 18 to 20 mm thick kota stone on vertical surfaces such as in skiting /dado of size as required at site over and including10 mm thick backing coat of cement mortar (1:4) complete all as specified and as directed.
M&L for 40 mm thick, rough dressed lime stone slab in flooring, laid and bedded on and including 20mm thick cement mortar 1:6 and pointed in cement mortar 1:3 complete all as specified and as directed.
M&L for rough dressed lime stone slab flooring, laid and bedded on and including 20mm thick cement mortar 1:6 and pointed in cement mortar 1:3 complete but expect stone slab all as specified and as directed. Note : Old stone slab obtained under dismantling under item No 1 shall be reused.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of brick masonary surfaces or concrete surfaces, finished even and fair without using extra cement complete all as specified and as directed.
M&L for 10mm thick rendering in cement mortar 1:6 on stone masonry or other than fair faces of brick or concrete surfaces, finished even and smooth with out using extra cement all as specified and as directed.
M&L for preperation of new plastered wall surfaces and applying two coats of distemper oil emulsion over a coat of chalk whitening over 1mm thick(average) wall care putty all as specified and as directed.
M&L for preparation of new plastered surfaces or previously untreated surface of wall and applying two coats of cement base paint over one coat of primer all as specified and as directed.
Complete removal of existing treatment from old decorated plastered or unplastered wall surfaces and applying two coats of distemper oil emulsion over a coat of chalk whitening all as specified and as directed
Complete removal of existing treatment from old decorated plastered or unplastered wall surfaces including cornices, pillars etc and applying two coats of cement base paint complete all as specified and as directed.
M&L for preparation of old painted surfaces of wood and wood based material over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed
M&L for preparation of old painted surfaces of steel over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and as directed
Hacking out old broken glass (any thickness ,size quality or description) from wooden / metal frames including punching or drilling out old glazing pins/spring clips all as specified and as directed.
M&L for 3mm thick sheet glass, ordinary quality fixed with oil putty, size of glass n.exc 0.50 sqm in each pane complete all as specified and as directed.
M&L for 3mm thick figured glass, pin headed type, glazing with oil putty in square n.exc 0.50 sqm in each pane of metal frame completeall as specified and as directed.
S&F 15mm dia bore galvanized tube medium grade with all fitting fixed complete on walls and ceiling or laid in floors all as specified and as directed.
S&F 20 mm dia bore galvanized tube medium grade with all fitting fixed complete on walls and ceiling or laid in floors all as specified and as directed.
S&F 15 mm bore, bib tap, cast copper alloy chromium plated with crunch or butterfly handle, screwed down for iron pipe complete all as specified and as directed.
S&F in repairs 15mm bore, bib taps,cast copper alloy, chromium plated, screwed down screwed for iron pipe or for brass ferrule and fixed all as specified and as directed.
S&F in repairs 15mm bore fancy type bib taps, cast copper alloy chromium plated with crutch/butterfly handle screwed down screwed for iron pipe or brass ferrule complete all as specified and as directed.
S&F 15 mm bore, stop valve , cast copper alloy chromium plated with crunch or butterfly handle, screwed down for iron pipe complete all as specified and as directed.
S&F in repairs 15 mm bore stop valves chromium plated, screwed both ends for iron pipe and fixed all as specified and as directed.
S&F in repairs 15mm bore stop valve, fancy type, cast copper alloy screwed down high pressure with crutch or butter fly handle screwed both end for iron pipes complete all as specified and as directed.
S&F PVC connections 15 mm dia, 300mm long with PTMT nuts all as specified and as directed.
S&F in repairs, PVC connections 15 mm dia, 600mm long with PTMT nuts all as specified and as directed.
S&F in repairs, 10 litre capacity, PVC coloured flushing cistern high/low level including ball valve, brackets, inlet, outlet PVC pipe complete all as specified and as directed.
Taking down carefully any type of point wiring (light, fan, bell, socket or power), complete excluding light fittings but including switches, ceiling roses, pendants, regulators, sockets, etc. and making good disturbed surfaces of walls, ceiling, floors etc to match with existing surface complete all as specified and as directed.
M & L for point wiring complete on surface of wall (open) type with two runs of 1.5 sqmm for phase and neuatral single core multistranded copper conductor cable of 1100 Volts grade PVC insulated and unsheathed , FRLS cable drawn through and including PVC casing and caping (ISI marked) and its accessories such as Tee, elbow, jointer, elbow corner etc. fixed on surface of walls, coloumns/ beams alongwith 1.5 Sqmm copper conductor cable (multistranded) PVC insulated and unsheathed FRLS cable as earth wire connected to common earth dolly at one end and metalic bodies of luminaire/ fan at other end including PVC folding boards for mounting switches, sockets, fan Regulators, accessories etc for One light/fan point controlled by one way switch all as specified and as directed NOTE: (1).Proper colour coding shall be adopted for wiring (for phas-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) (2 ). All points shall be earthed up to fixtures i.e holders,tube lights,all lights,ceiling lights,bulkhead lights,bldg security lights etc.)
All as per serial item No 84 above but one 5 Amp 5 pin socket outlet point on same board with other switches
All as per serial item No 84 but for one switch socket out let 3 pin, 5 Amps point on independent board.
All as per serial item No 84 above but with 2.5 Sqmm (36/0.30mm) PVC copper stranded cable FRLS type for one 15 Amp 6 pin socket outlet point including PVC cable 2.5 Sqmm FRLS type copper stranded conductor as earth wire as specified & connected to commen earth & earth terminals including PVC/wooden folding boards for mounting purposes all as specified and as directed
S&F switch piano, flush type , single pole , one way , 6 Amps, 230 volts complete all as specified and as directed.
S&F socket outlet flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified and as directed.
S&F switch socket combination flush type 5 pin 5 Amp multipurpose 230 volts single pole one way suitable for 3 pin/2pin 5 Amp plug top white/ivory finish all as specified & directed.
S&F switch socket combination multipurpose, flush type 2 in 1 type (6 pin ) 6/16 Amps, 230V, AC. all as specified and as directed.
S&F ceiling rose, surface PVC 50mm dia 3 terminals including PVC mounting block white/ivory finish all as specified and as directed.
S&F lamp holder angle/batten type, PVC/Polycarbonate type with back plate suitable for batten fittings all as specified and as directed.
S&F in replacement and connecting up fan regulator electronic on existing phenolic laminated sheet 5 step socket type 230 volts, 450 watts suitable for ceiling fan 1200/1400mm sweep all as specified and as directed.
S&F ceiling fan with blades,down rods, electronic type regulator and accessories, 230 V, 1200 mm sweep, BEE 5 star rated with brushless direct current motor (BLDC) complete with all acessories and connections all as specified and as directed.
S&F 300 mm sweep metallic exhaust fans, AC, single phase, 230/240 volt, with blades, frame and louvers including making hole in brick/stone masonry for fixing of exhaust fan and making good disturbed surfaces with cement mortar and cement plaster and applying two coats of distemper oil emulsion of same pattern/tint complete complete all as specified and as directed.
Supply, installation , testing and commissioning of vertical water heater storage type, steel body with copper inner tank and heating element upto 2 KW of capacity 25 litres,BEE 5 star rated, AC, 50 Hz, 230 Volts complete with thermostate, temperature control knob,,NRV, safety valve, inlet and outlet ports, connection piece and all acessories and connections all as specified and as directed.
S&F in repairs, LED box type fitting pre-wired including LED tube 1 x 20 W connecting up with PVC insulated and sheathed 1100 volt grade flexible copper cable complete all as specified and as directed. Make:- Jaquar Model-LGLZ01X020XC/ LGLZ01X020XN/LGLZ01X020XW or Havells Model-LUMILINEPLUSBS20WLED865SPCSS or equivalent model of make Philips / GE/ Crompton/ Halonix/ Century LED/Luker
S&F in repairs, LED light fitting, Lumeno LED bulb 10 Watt (Cool day light) having colour temp 6500 K and lumen output 900 suitable for B-22 type to fix on batten holder and wall light etc complete all as specified and as directed. Make : Havells cat No LHLDEUEEML8R010 or Equivalent model of make Philips / GE/ Luker/ Crompton/ Halonix/ Century LED
M&L for submain wiring with two single core PVC insulated unsheathed, multistranded flexible FRLS copper conductor 1100Volts grade cables 4 Sqmm drawn through and including PVC heavy duty surface casing caping, including 2.5 Sqmm 1100Volts grade PVC insulated unsheathed multi stranded flexible FRLS copper conductor cable as continuous earth wire and connecting to common earth terminals including taking down old sub-main wiring complete all as specified & as directed. NOTE: (1) Proper colour coding shall be adoptd for wiring (for phase-RED,YELLOW,BLUE for Earth-Green and Neutral-Black) (2) Two run of 4 sq.mm for one run for phase,one run for neutral with one run of 2.5 sqmm cable for earth and one run of PVC casing & caping shall be measured as one unit all as specified and as directed.
S&F in repairs, ISOLATOR, TPN, AC 415 V, 63 amps 10 KA capacity ,'B' series making connection with suitable size of copper lugs etc complete all as specified and directed.
S&F in repairs, MCB SP, AC 240 V, 6 to 32 Amps, 10 KA capacity ,'b' series making connection with suitable size of copper lugs etc complete all as specified and as directed.
S&F in repairs, MCB SPN, AC 240 V,40 Amps 10 KA capacity ,'c' series making connection with suitable size of copper lugs etc complete all as specified and as directed.
S&F in repairs, sheet metal enclosure (Factory made), double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 volts, 8 way, protection class IP-42, suitable for fixing MCBs,Isolators etc,confirming As per IEC 61439-3,suitable for flush mounting and surface mounting,with 200 Amps rated copper busbar,with Neutral bar,Earthbar and cable lies for cable managment,fully shrouded,Neutral bars,prefittes masking sheet complete all as specified and as directed. Make: Havells,Cat No:DHDMSH0DDW04 or Equivalent model of make Philips / GE/ Luker/ Crompton/ Halonix/ Century LED
S&F in repairs, sheet metal enclosure (Factory made) double door shutter type for distribution board (when MCBs are to be used) single pole and neutral 240 volts 4 way protection class IP-42,suitable for fixing MCBs,Isolators etc,confirming As per IEC 61439-3,suitable for flush mounting and surface mounting,with 200 Amps rated copper busbar,with Neutral bar,Earthbar and cable lies for cable managment,fully shrouded,Neutral bars,prefittes masking sheet complete all as specified and as directed. Make: Havells,Cat No:DHDMSH0DDW04 or Equivalent model of make Philips / GE/ Luker/ Crompton/ Halonix/ Century LED
S&F in repairs, security light of building with single piece new generation energy savng and environmental friendly long life LED, 30W, made up of pressure die cast aluminium housing with acrylic covers as diffuser with IP66 protection and impact resistance of IK07 including one bracket made of Light grade GI Pipe 25 mm dia 1.5 mtr long fixed to wall/ pole with two clamps made out of mils steel FI 40 mm x 5 mm and connect to nearest electric supply by three core 1.5 sqmm aluminium cable all as specified and as directed. Make : Havells Cat No ENDURACITYLITEPLATSL30WLED757SASYBOPC or equivalent model of make Philips / GE/ Crompton/ Halonix/ Century LED/Luker
M&L in repairs/replacement earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level, connecting to the GI wire 4 mm dia , by means of nut bolts, check nuts and washer of the GI . Earth wire connected upto main earth point/DBs alongwith 15mm dia GI pipe, medium grade, including provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregates with 40 mm thick RCC (1:2:4) cover with reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, test point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified including testing on completion.
S&F LT XLPE insulated, PVC sheathed, armoured heavy duty, electric cable with aluminium conductor of size 10 sqmm 4 core,1100 volts grade conforming to relevant IS, ISI marked, laid in trenches / wall / floor/ poles, including making connection using suitable size aluminium lugs including testing and commissioning including taking down old cables with protection covers complete all as specified and as directed. Note : Excavation/earth work, provision of sand cushioning and brick protection shall be measured and paid for separately under respective items
Supply, laying and testing LT XLPE, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sqmm 2 core including making connection using suitable size aluminium lugs all as specified and as directed.
Supply, laying and testing LT XLPE, Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core including making connection using suitable size aluminium lugs all as specified and as directed.
M&L for sand cushioning with natural dry unwashed river sand and punning down in layers all as specified and as directed. NOTE : For measurement purpose, only punned thickness of sand shall be considered.
M&L for sub class ‘B’ old size well burnt brick laid flat in trenches with length of brick perpendicular to length of cable, over the cable for protection of LT cable complete all as specified and as directed.
Taking out/down and opening of existing ceiling fans 1200 mm sweep, from any position of any make etc & refixing at the desired location after reassembling and after servicing/overhauling by throughly cleaning the shaft,rotor,stator and applying lubricant/grease to bearings and one coat of super enamelled varnish over winding to improve the insulation resistanc including repair/replacement of spare parts/material/items,making connection by replacing PVC insulated unsheathed cable of copper conductor of size 1.50 sqmm upto 0.5 mtr length including using material/parts of minor nature such as screws,lugs,insulation tape,nuts,bolts,washers etc after cleaning the metal surface,greasing/lubricant etc to make it functional complete all as specified and as directed. NOTE: The connected items required like capcitor, bearings,bush,canopy,down rods etc will be measured and paid separetely under respective items all as specified and as directed.
S&F in replacement of ball bearing No 6201. etc complete all as specified and as directed all as specified and as directed.
S&F in replacement of ball bearing No 6202. etc complete all as specified and as directed. all as specified and as directed.
S&F in replacement of canopy (top and bottom) of ceiling fans any make / size with canopy of matching colour all as specified and as directed..
S&F in replacement of rubber reel with nut, bolts, split pins etc of ceiling fan with rubber reel heavy duty for hanging fan all as specified and as directed..
S&F in replacement of down rod with clamps etc of ceiling fan with down rod of 15mm bore medium grade GI pipe 0.6 metre long with clamps, bolts, nuts, split pins washers of suitable size of approved quality all as specified and as directed.
S&F in replacement of connector block of ceiling fan of suitable size of approved quality all as specified and as directed.
S&F in replacement of capacitor of ceiling fans with capacitor having capacity 2.5mfd, 240 Volts complete all as specified and as directed.
M&L for cutting the existing bituminous road / PCC hard standing upto 75cm in depth, 60cm in width and getting out excavated materials, making good the damaged portion after laying of pipes by returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick and PCC 1:2:4 type B1 using 20mm graded stone aggregate upto 30cm depth from top of the road all as specified and as directed.
S&F 25mm bore dia GI tubing, medium grade, laid in trenches / floors or fixed to wall in any length with screwed and socket joints together with all galvanised GI fitting such as sockets, bends, elbows, tees, reducers, unions, jointing materials etc and pressure testing, washing out, including dismantling, taking out old corroded pipe complete all as specified and as directed.
All as per serial item No 122 above but 40mm bore dia of pipe.
All as per serial item No 122 above but 50mm bore dia of pipe.
All as per serial item No 122 above but 80mm bore dia of pipe.
S&F in repairs, 25mm size Gun metal or Bronze globe / ball valve, ISI Marked, screwed both ends suitable for GI tubing with side way operating GI lever handle, complete all as specified and as directed.
All as per serial item No 126 above but 40mm size
All as per serial item No 126 above but 50mm size
S&F in repairs, PVC foot valve, 40mm size, suitable as per existing foot valve all as specified & as directed.
S&F 80mm bore dia, sluice valve, cast iron long body both ends flanged as per IS-14846 and drilled with stainless steel spindle iron wheel head and as per pressure rating PN 1.6, Class I, ISI Marked alongwith nuts, bolts, washers , gaskets etc. including dismantling and taking out old sluice valve from valve chamber / trenches, all as specified and as directed.
Supply, install, testing and commissioning of heavy duty high performance and high efficiency, Horizontal Openwell Submersible pump, single or multi stage water pump of discharge capacity 10 HP,1620 LPM at 20 mtr head, having horizontal mounting with bronze impellar, high tensile carbon steel shaft, protection sleeve, gland packed stuffing box or with mechanical sealing arrangement having 100 mm dia suction and 100 mm dia delivery, 1450 RPM, 400 V, 3 phase 50 Hz TEFC, AC electric motor of Suitable HP including suitable anti vibration mounting / fixing arrangement for base frame of pump set as designed / recommended by the manufacturer, connecting the pump motor with and including fully automatic star delta starter (with standard protective / safety devices relays, single phase preventor etc as supplied alongwith the motor of suitable capacity) suitable size of PVC insulated stranded copper conductor cables, encased in and inclusive of flexible conduits or PVC pipes heavy gauge of duly embedded in floor from starter to motor, pressure gauge with stop valve 1/2" size at delivery side and with all standard accessories / fittings / devices and including supply of 2 years normal maintenance spares as per manufacturer standard recommended list complete all as specified and as directed. Make: Kirloskar/Crompton /KSB
Supply, install, testing and commissioning of heavy duty high performance and high efficiency, MONOBLOCK, automatic air release type, single or multi stage water pump of discharge capacity 1.02 HP,1200 LPM at 20 mtr head, having horizontal mounting with bronze impellar, high tensile carbon steel shaft, protection sleeve, gland packed stuffing box or with mechanical sealing arrangement having 25 dia suction and 25 mm dia delivery, 1200RPM, 415 V, single phase 50 Hz TEFC, AC electric motor of Suitable HP rating with tall fins for better heat dissipetion and having 'F' class insulation complete mounted on common MS base plate RCC foundation and foundation bolt grouted in PCC including suitable anti vibration mounting / fixing arrangement for base frame of pump set as designed / recommended by the manufacturer, suitable size of PVC insulated core stranded copper conductor cables, encased in and inclusive of flexible conduits or PVC pipes heavy gauge of duly embedded in floor from starter to motor, pressure gauge with stop valve size at delivery side and with all standard accessories / fittings / devices and including supply of 2 years normal maintenance spares as per manufacturer standard recommended list complete all as specified and as directed. Make: Kirloskar/Crompton /KSB
Vinod Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .