Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 CrAccepted-AOC B 3 3 DHANALAXMI PARK OPP PMT BUS DEPOT BHUSARI COLONY PAUD ROAD KOTHRUD PUNE 411 038 | PUNE | PUNE | MAHARASHTRA | 411038 | ₹4.8 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹4.9 CrRejected-Finance PLOT NO 212 VAISHNAV NAGAR KEDGAON AHMEDNAGAR 411 001 | AHMEDNAGAR | PUNE | MAHARASHTRA | 411001 | ₹4.9 Cr | L2 | Rejected-Finance Not Lowest |
| 3 | L3₹5.1 CrRejected-Finance 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | ₹5.1 Cr | L3 | Rejected-Finance Not Lowest |
| 4 | L4₹5.2 CrRejected-Finance 223 3 E B 1 MALTI TOWER TARABAI PARK KOLHAPUR 416 003 | KOLHAPUR | KOLHAPUR | MAHARASHTRA | 416003 | ₹5.2 Cr | L4 | Rejected-Finance Not Lowest |
| 5 | L5₹5.7 CrRejected-Finance FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | ₹5.7 Cr | L5 | Rejected-Finance Not Lowest |
| Sl No | Description | Qty | Unit | Baljeet Singh Choudhari L1 | D R CONSTRUCTION L4 | Mehta Construction Co. L3 | UNIQUE ENGINEERS L5 | DARSHAN CONSTRUCTION Co. L7 | M/s S. R. Constructions L6 | SIDDHESH CONSTRUCTION L2 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00SCH 'A' PART-I : Note: These schedules are not pre-priced by MES and the Estimated rate 0.00 indicated against the respective schedule under Col 6 signifies this fact only. The tenderer is required to quote their lumpsum amount under col 13 against item of works catered under these schedule . | ||||||||||
| 1.01 | Construction of wet canteen (G+1) building including modular kitchen with permanent specification in RCC M-30 grade, using AAC brick masonry, UPVC windows, RCC roof and all fittings and fixtures complete all as specified and directed and as shown on drawings as listed in Schedule ‘A’ Part I | 1 | Lump Sum | 3,20,00,001 ₹3.2 Cr | 3,83,71,872.03 ₹3.8 Cr | 3,24,00,000 ₹3.2 Cr | 3,82,10,000 ₹3.8 Cr | 4,00,00,000 ₹4 Cr | 3,85,00,000 ₹3.9 Cr | 3,03,88,852.56 ₹3.0 Cr |
| 1.02 | Lumpsum price inserted under col 13 by the tenderer C septic tank designed to carry sewage and sullage water, excavation for 50 users including all fittings and fixtures complete all as shown on drawings and as specified as listed in Schedule ‘A’ Part I | 1 | Lump Sum | 1,00,000 ₹1 L | 4,50,000 ₹4.5 L | 3,51,000 ₹3.5 L | 1,00,000 ₹1 L | 3,50,000 ₹3.5 L | 5,00,000 ₹5 L | 6,60,000 ₹6.6 L |
| 1.03 | Lumpsum price inserted under col 13 by the tenderer worked out by the contractor for Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design / TD drawing with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including all fittings and fixtures complete all as shown on drawings and as specified. as listed in Schedule ‘A’ Part I | 1 | Lump Sum | 75,000 ₹75,000 | 30,000 ₹30,000 | 1,80,000 ₹1.8 L | 1,00,000 ₹1 L | 1,50,000 ₹1.5 L | 3,00,000 ₹3 L | 2,64,000 ₹2.6 L |
| 2.00SCH 'A' PART-II to XIV : Note: These schedules are pre-priced by MES and the rate indicated against the respective schedule under Col 6 signifies this fact only. The tenderer is required to quote their lumpsum amount under col 13 against item of works catered under these schedule . | ||||||||||
| 3.00 | Lumpsum price inserted under col 13 by the tenderer for SITE CLEARANCE AND DEVELOPMENT as listed in Schedule ‘A’ Part II representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part II | 1 | Lump Sum | 6,48,182 ₹6.5 L | 8,48,436.24 ₹8.5 L | 7,38,762.24 ₹7.4 L | 8,50,000 ₹8.5 L | 8,50,000 ₹8.5 L | 8,00,000 ₹8 L | 11,89,226 ₹11.9 L |
| 4.00 | Lumpsum price inserted under col 13 by the tenderer for Internal Electrification as listed in Schedule ‘A’ Part III representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part III | 1 | Lump Sum | 8,99,370 ₹9.0 L | 8,42,678.14 ₹8.4 L | 7,69,445.04 ₹7.7 L | 9,00,000 ₹9 L | 9,00,000 ₹9 L | 9,00,000 ₹9 L | 8,98,729.92 ₹9.0 L |
| 5.00 | Lumpsum price inserted under col 13 by the tenderer for Internal Water Supply as listed in Schedule ‘A’ Part IV representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part IV | 1 | Lump Sum | 93,300 ₹93,300 | 63,061.4 ₹63,061.40 | 66,408.11 ₹66,408.11 | 1,00,000 ₹1 L | 1,50,000 ₹1.5 L | 1,25,000 ₹1.3 L | 96,328.32 ₹96,328.32 |
| 6.00 | Lumpsum price inserted under col 13 by the tenderer for External Water Supply as listed in Schedule ‘A’ Part V representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part V | 1 | Lump Sum | 52,800 ₹52,800 | 37,247.78 ₹37,247.78 | 39,226.51 ₹39,226.51 | 50,000 ₹50,000 | 75,000 ₹75,000 | 50,000 ₹50,000 | 56,901.24 ₹56,901.24 |
| 7.00 | Lumpsum price inserted under col 13 by the tenderer for External Electrification as listed in Schedule ‘A’ Part VI representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part VI | 1 | Lump Sum | 40,000 ₹40,000 | 22,089.9 ₹22,089.90 | 30,522.17 ₹30,522.17 | 28,000 ₹28,000 | 45,000 ₹45,000 | 35,000 ₹35,000 | 40,971.48 ₹40,971.48 |
Updated dates
Tender Value
₹5.2 Cr
EMD Value
₹5.9 L
Closing Date
6 Apr 2026, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
PROVISION OF WET CANTEEN AS SPECIAL WORK AT HEMRL PUNE
2026_MES_748789_1
81403
Open Tender
Civil Works
365 days
PASHAN PUNE
Class A
category a(i)
8 documents required · 8 mandatory
₹3,000
GARRISON ENGINEER I RND PASHAN PUNE
₹5.9 L
Yes
29 May 2026
16 Jan 2026
8 Apr 2026
16 Jan 2026
6 Apr 2026
30 Mar 2026
SCH 'A' PART-I : Note: These schedules are not pre-priced by MES and the Estimated rate 0.00 indicated against the respective schedule under Col 6 signifies this fact only. The tenderer is required to quote their lumpsum amount under col 13 against item of works catered under these schedule .
Lumpsum price inserted under col 13 by the tenderer worked out by the contractor for Construction of wet canteen (G+1) including all fittings and fixtures complete all as shown on drawings and as specified as listed in Schedule ‘A’ Part I
Lumpsum price inserted under col 13 by the tenderer C septic tank designed to carry sewage and sullage water, excavation for 50 users including all fittings and fixtures complete all as shown on drawings and as specified as listed in Schedule ‘A’ Part I
Lumpsum price inserted under col 13 by the tenderer worked out by the contractor for Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design / TD drawing with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including all fittings and fixtures complete all as shown on drawings and as specified. as listed in Schedule ‘A’ Part I
SCH 'A' PART-II to XIV : Note: These schedules are pre-priced by MES and the rate indicated against the respective schedule under Col 6 signifies this fact only. The tenderer is required to quote their lumpsum amount under col 13 against item of works catered under these schedule .
Lumpsum price inserted under col 13 by the tenderer for SITE CLEARANCE AND DEVELOPMENT as listed in Schedule ‘A’ Part II representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part II
Lumpsum price inserted under col 13 by the tenderer for Internal Electrification as listed in Schedule ‘A’ Part III representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part III
Lumpsum price inserted under col 13 by the tenderer for Internal Water Supply as listed in Schedule ‘A’ Part IV representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part IV
Lumpsum price inserted under col 13 by the tenderer for External Water Supply as listed in Schedule ‘A’ Part V representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part V
Lumpsum price inserted under col 13 by the tenderer for External Electrification as listed in Schedule ‘A’ Part VI representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part VI
Lumpsum price inserted under col 13 by the tenderer for Road / Path / Culvert / Hardstanding as listed in Schedule ‘A’ Part VII representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-VII
Lumpsum price inserted under col 13 by the tenderer for Sewage Disposal as listed in Schedule ‘A’ Part VIII representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-VIII
Lumpsum price inserted under col 13 by the tenderer for Area Drainage as listed in Schedule ‘A’ Part IX representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-IX
Lumpsum price inserted under col 13 by the tenderer for Fencing / Compound Wall / Gate as listed in Schedule ‘A’ Part X representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-X
Lumpsum price inserted under col 13 by the tenderer for Rain Water Harvesting as listed in Schedule ‘A’ Part XI representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-XI
Lumpsum price inserted under col 13 by the tenderer for Air Conditioning and Refrigeration as listed in Schedule ‘A’ Part XII representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-XII
Lumpsum price inserted under col 13 by the tenderer for Fire Alarm and Fire Fighting System as listed in Schedule ‘A’ Part XIII representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-XIII
Lumpsum price inserted under col 13 by the tenderer for Standby Power Supply DG Set as listed in Schedule ‘A’ Part XIV representing the percentege arrived under col 54 above/below the lumpsum estimated rate inserted under col 6 by the MES in Schedule ‘A’ Part-XIV
SCHEDULE 'A' PART-XVII (MISCELLANEOUS B/R AND E/M Items) Note: This schedule is not pre-priced by MES and the rate indicated as "Rs 0.00" under Col 6 signifies this fact only.The tenderer is required to quote their rate under col 13 against item of works catered under this schedule .
SITE CLEARANCE AND DEVELOPMENT
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick each layer in soils complete all as specified and directed.
Removing excavated materials / soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation or for laying of pipe / cables / poles manholes etc., not exceeding 10 Sqm on plan and getting out in hard / dense soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation for laying of pipes / cables / poles etc, and getting out in soft / loose soil complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation for laying of pipes / cables / poles etc, and getting out in soft / disintegrated rock complete all as specified and directed.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5 m in depth for foundation for laying of pipes / cables / poles etc, and getting out in hard rock complete all as specified and directed.
INTERNAL ELECTRIFICATION
Wiring for One 3 pin socket outlet 5/6 amps point on the Independent board with 1.5 sq mm FRLS PVC insulated copper conductor single core multistrand copper conductor FRLS cable drawn into & including concealed medium grade PVC conduit with one way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required complete
Wiring for One 3 pin socket outlet 5/6 amps point on the same board with 1.5 sq mm FRLS PVC insulated copper conductor single core multistrand copper conductor FRLS cable drawn into & including concealed medium grade PVC conduit with one way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required complete
Wiring for One 3 pin socket outlet 6/16 amps point on the Independent board with 2.5 sq mm FRLS PVC insulated copper conductor single core multistrand copper conductor FRLS cable drawn into & including concealed medium grade PVC conduit with one way modular switch, modular plate, suitable GI box and earthing the point with 2.5 sq mm FRLS PVC insulated copper conductor single core cable etc. as required complete
S&F, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps 240 volts complete all as specified and directed.
S&F, triple pole and neutral enclosure witha three pin and earth plug and socket complete with one tripple pole MCB 32 Amps 415 volts complete all as specified and directed.
S&F, LED tube light fitting 1 x 20 W, 4 feet long wall mounted anodized aluminium extruded head provided for efficient heat dissipation and integrated and interchangeable integrated electronic driver luminaries LED as light source housing complete with all accessories including 20 W tube rod complete prewired and including up with twin core twisted flexible copper cable of suitable size complete all as specified and directed.
S&F, energy saving, environmental friendly, long life, corrossion resistant, impact proof, surface mounting luminaire with PC housing & opal finish cover LED 40 W light fitting 4 feet x 1 complete all as specified and directed.
S&F, LED light 24 W, surface mounted downlights with aluminium housing and heat sink for better performance provided for efficient heat dissipation and integrated and interchangeable integrated electronic driver luminaries LED as light source housing complete with all accessories and including up with twin core twisted flexible copper cable of suitable size complete all as specified and directed.
S&F, LED tube light 36 W 2 x 2 feet, surface mounted downlights square type with aluminium housing and heat sink for better performance provided for efficient heat, soft light, glare free symmetrical illumination and integrated electronic driver luminaries LED as light source housing complete with all accessories and prewired up with twin core twisted flexible copper cable of suitable size complete all as specified and directed.
S&F, LED light fitting 1 x 9W / 1 x 10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F, new generation energy saving and environmental friendly long life LED building security light 25 watt made up of pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and impact resistance of IK07 including fittings complete all as specified and directed.
S&F, security light bracket made out of 40mm dia medium grade GI pipe of 1.5 Mtr long bend to shape including single coat of aluminium paint over a coat of red primer painting and fixing clamps, nut bolts complete all as specified and directed.
S&F, exhaust fan steel body AC single phase 230V of size 300m sweep with blades and frame and louvers 900RPM complete all as specified and directed.
S&F, electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 50 litre, BEE star rated complete with all accessories such as safety valve, thermostat, NRV, connection piece etc., complete all as specified and directed.
S&F, wall mounting fan (air circulator) heavy duty, steel body AC single phase, 230 V of size 450 mm sweep complete all as specified and directed.
S&F, connecting and testing MCCB 4 pole 100 A, 440 volts, 16 kA complete all as specified and directed.
S&F, connecting and testing MCCB 4 pole 63 A, 440 volts, 16 kA complete all as specified and directed.
S&F, connecting and testing MCB triple pole, 230 volts of capacity 32 Amps, 10 kA 'C' curve complete all as specified and directed.
Supply, fixing, connecting & testing, MCB single pole and neutral (MCB SPN) 230 volts of capacity 6 to 32 Amps, 10 kA 'C' curve complete all as specified and directed.
Supply, fixing, connecting & testing, MCB single pole (MCB SP) 220 volts of capacity 6 to 32 Amps, 10 kA 'C' curve complete all as specified and directed.
S&F, triple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB of capacity 32 Amps, 10 kA 'C' curve complete all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60 x 60cm x 6 mm buried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of the plate not less than 1.5 m below normal ground level, connected to galvanized earth lead wire 4 mm dia by means of galvanized iron or steel bolts, nuts, check nuts & washers and connected to equipments as directed, including funnel with GI medium grade watering pipe 20 mm bore, wire mesh, charcoal or coke and common salt in alternate layers of 15 cm compacted thickness all around the earth electrode with concrete pit in PCC 1:3:6 type C1, 50 mm thick precast RCC 1:2:4 type B1 cover slab reinforced with 8 mm dia deformed bar 15 cm c/c and suitable handle of 10 mm dia round bar, GI medium grade pipe for earth lead protection including necessary excavation earthwork in soft / loose soil and disposal of spoil to a distance not exceeding 50m and necessary testing complete all as specified in DSR/ relevant IS complete all as specified and directed. Note: Earth wire beyond 7.5m shall be measured and paid seperately.
M&L for earth continuity conductor with 4 mm galvanised iron wire fixed to wall on batten or recess or chases with necessay porcelain insulators or buried in ground or drawn in conduit / pipe / wall or fixed to poles or any other indicated situation for loop earthing complete all as specified and directed.
Supply, laying & testing, cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminum conductor of size 35 sq mm 3.5 core complete all as specified and directed.
INTERNAL WATER SUPPLY
S&F, fancy type pillar tap, cast copper alloy, with capstan heads, brass chromium plated, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete of size 15mm dia pipe complete all as specified and directed.ge.
EXTERNAL WATER SUPPLY
Supply & laying, 80mm dia tubes, 'medium grade' galvanised, with all fittings and fixed walls, ceiling or laying in floors or laid in trenches complete all as specified and directed.
Supply & laying, 50mm dia tubes, 'medium grade' galvanised, with all fittings and fixed walls, ceiling or laying in floors or laid in trenches complete all as specified and directed.
Supply & laying, 25mm dia tubes, 'medium grade' galvanised, with all fittings and fixed walls, ceiling or laying in floors or laid in trenches complete all as specified and directed.
Cutting cast iron pipes 150mm dia and reducing to required length before laying in position for insertion of new tees, branches etc., complete all as specified and directed.
EXTERNAL ELECTRIFICATION
Supply, laying & testing, cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3.5 core complete all as specified and directed.
Supply & lay in trenches un-reinforced precast concrete cable cover class LV type 1 flat size 250 x150 x 40 mm for cable protection complete all as specified and directed.
Sand (stone crushed sand) in cable trenches as cushioning to cables including spreading and punning down complete all as specified and directed. Note: Punned thickness shall only be measured and paid.
S&F, MCCB 250 Amps rating and breaking capacity 36 KA, 4 pole, 415 volts with thermal magnetic release terminal spreaders with SS enclouser including grouting nut bolts or fasteners in wall fixing and connecting complete with suitable size of lugs and thimbles complete all as specified and directed.
Supply, install, testing & commissioning, factory made and tested, CPRI approved LT panel board outdoor type, hood on top weather, vermin proof, free standing floor mounting type, cable alley for all the feeders, suitable for 440 Volts, 3 Phase 4 wire 50Hz AC supply system, conforming to IS, IP-64 class protection and made of 3.15 mm CRCA mild steel sheet with 50 x 50 x 6mm angle iron frame, hinged doors, front & rear opening and locking arrangement and duly powder coated on the outside and inside including necessary earthwork excavation and and provision of 02 Nos earth terminals on both sides, cable glands and PCC foundation with PCC 1:2:4, type B1, using 20mm graded crushed stone aggregate of suitable size to accommodate and including cable gland and lugs for incoming and outgoing cable etc., complete and comprising of the the following:-
INCOMING: (a) Bus bar chamber with aluminium bus bar suitable for 400 Amps capacity for 3 phase and neutral (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrinked insulating sleeves.
(b) MCCB 4 pole adjustable thermal / magnetic setting, 250 Amps, 415 Volts 36 kA - 01 No. (c) On load change over switch open execution 4 pole 250 A, 415 V AC supply - 01 No. OUTGOING: (a) MCCB 4 pole adjustable thermal / magnetic setting, 100 Amps, 415 Volts 25 KA - 02 Nos. (b) MCB SPN 16 A - 02 Nos (c) LED indicator lamp 22.5 mm dia RYB, 230 volts - 01 set. (d) Panel wiring with suitable size PVC insulated heavy duty 1100 volts grade single core cable with copper conductor multistranded with cable end terminaion lugs. (e) Digital multifunction meter for Amps / Volts / KWH / PF and other parameter.
M&L for special factory made earthing electrode comprising of hot dipped galvaized MS flat inserted in to GI pipe of 88mm bore (outer), 3m length, filled with non magnetic anti corrosive material specially developed for ground resistance enhancement power around the electrode to retain moisture conforming to IS 3043 including necessary boring in ground of 150 / 200mm dia in any type of strata connecting to test point (the earth resistance shall be less than 1 ohm complete all as specified and directed. Contractor shall improve the earthing resistance within the permissible limit without any extra cost.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing as required 32 x 6 mm dia galvanised iron or steel strip complete all as specified and directed.
ROAD / PATH / CULVERT / HARDSTANDING
M&L for hardcore of broken stone or boulder of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and well rammed to a true surface complete all as specified and directed.
RAIN WATER HARVESTING
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 complete all as specified and directed.
M&L for hardcore of guage not exceeding 63mm deposited spread and levelled in layers not exceeding 150 mm thick watered and rolled / rammed to a true surface complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for flush pointing to to random rubble uncoursed or brought upto courses in CM 1:3 complete all as specified and directed.
AIR CONDITIONING AND REFRIGERATION
S&F, refrigerators, electric driven (single phase), capacity 350 Litres of BEE 5 star rating, frost free, rated voltage 230 (+ 10%), 50 Hz complete all as specified and directed.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven, 230 volts, 50 Hz single phase having approx storage and nominal cooling capacity 150/150 complete all as specified and directed.
Supply, installation, commissioning of Metal Top Deep Freezer 400 ltrs capacity single phase 240 volt, 50 Hz, suitable to working temprature range of tropical temperature range with two compartment suitable to storage fozen foods and dairy products without cross contamination complete all as specified and directed.
Supply, installation, commissioning of Glass Top Deep Freezer 400 ltrs capacity single phase 240 volt, 50 Hz, suitable to working temprature range of tropical temperature range with two compartment suitable to storage fozen foods and dairy products without cross contamination complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 2 KVA complete all as specified and directed.
Voltage stabilizer for automatic operation, single phase naturally air cooled type & designed for input variation between 150 V to 280 V with output voltage stabilized at 230 with accuracy ± 1% and speed of correction 50 Volts per second and of capacity 1 KVA complete all as specified and directed.
FIRE ALARM AND FIRE FIGHTING SYSTEM
S&F, Beam Master detector with Transmitter and receiver (add power supply unit & module) complete all as specified and directed.
Supply, laying & testing XLPE insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 1.5 sq mm, 2 core, 1100 Volts grade for connecting fire detector, test point and hooters with control panel complete all as specified and directed.
Supply, laying & testing XLPE insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric control cables (heavy duty) with stranded copper conductor of size 2.5 sq mm, 2 core, 1100 Volts grade for connecting siren with control panel complete all as specified and directed.
Supply, install, testing & commissioning of 8 zone electronic automatic fire alarm / supervisory control panel indoor type operating on 110-220 Volts, 50 Hz AC electric supply including battery charger as required complete all as specified and directed.
S&F, cable termination junction box size 93 x 93 x 62 mm, IP 66 with terminals for connection of armoured cables of detector including flame proof double compression brass cable gland complete all as specified and directed.
S&F, sealed maintenance free battery 12 Volt 28 AH including battery box complete all as specified and directed.
S&F, hose box made of 18 gauge MS sheet 800mm x 600mm x 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside yard complete all as specified and directed.
S&F, non percolating flexible fire fighting two layered delivery hose, synthetic fiber circular woven jacketed with EPDM synthetic rubber lined, 38 kgf/cm2 burst pressure, 23 kgf/cm2 proof pressure, 15 kgf/cm2 working pressure, bearing IS:636-2018 type 1 (uncoated), 63 mm x 15 mtr length duly SS wire bounded to fire hose coupling, gunmetal, instantaneous type, pair of male and female parts, bearing IS:903 mark complete all as specified and directed.
S&F, fire hydrant stand post with provision of single outlet conforming to IS 908 complete all as specified and directed.
Cutting cast iron pipes 150 mm dia and reducing to required length before laying, in position for insertion of new tees, branches etc., complete all as specified and directed.
M&L for fire point fabricated with MS angles and MS sheet on top including provision of 03 Nos bucket filled with fine sand, 03 Nos fire exinguishers ABC type 6.0 Kgs, 01 No. fire beater with bamboo and one No. fire hook with bamboo complete with necessary PCC foundation with 1:2:4 using 20 mm aggregate and sand derived from natural sources complete all as specified and directed.
STANDBY POWER SUPPLY DG SET
Supply, installation, commissioning & testing of silent, Diesel engine driven factory assembled, generating set of capacity 100 KVA, 3 phase, 4 wire, 50 Hz, 1500 RPM complete with engine and alternator mounted on a common MS fabricated base frame with AVM pads, acoustic enclosure, relay panel for automatic starting on main failure safety control and metering equipments mounted on & including common base frame and installed on PCC foundation as recommended by manufacturer and approved by GE and suitable for ambient conditions at Pune, environmental eco-friendly as per CPCB IV norms including the following all as specified and directed.
Genset - ISO 8528. Note: PCC foundation work as per manufacture instructions, anti vibration pads and other standard accessories and comprising. Diesel Engine: No of cylinders 06, Inline arrangement, Gross engine power (HP) 303.4 and (KWm) 223, water cooled, Turbocharged with after cooled, rated output 1500 RPM and Overspeed trip 1650 RPM. Engine is with electric start, compression ignition, 4 stroke cycle, designed to run continuously at 1500 RPM confirming to IS 10002, ISO-3046, BS 5514 standards. Diesel engines should comply with CPCB IV norms.
The Diesel Engines are comprising of followings: (i) Radiator with Fan. (ii) Fuel Injection equipment with Electronic Governor having CRS (Common Rail System) and DG performance class G3. (iii) Dry type Air Cleaner. (iv) Exhaust Silencer type NA, Max allowable backpressure (kPa) 17, Exhaust temperature (Deg C) 550. (v) Lube Oil filter (Spin On Type). (vi) Fuel Oil filter (Spin On Type). (vii) 24V Electric starting system. (viii) Battery charging alternator. (ix) Stop Solenoid. (x) Lube Oil pressure Gauge. (xi) Water Temperature Gauge. (xii) Lube Oil temperature Gauge. (xiii) Battery Voltage. (xiv) Extended life coolant. (xv) First Fill Lube Oil.
Alternator: Alternator type 4P, rotating field, automatic voltage regulator and voltage regulation +1%, suitable for continuous duty operations rated at 1500 RPM 415 V, 0.8 PF, 50Hz, current (3Ph) (Amps) 347.8 in SPDP enclosure, self- excited & self-regulated, Brushless, ‘H’ class insulation, temperature rise (Deg C) 125, coupling type Flex disc, unbalanced load capability 25% of rated Amps, floor mounted with anti frication sealed ball bearing on end. Alternator charging 12 VDC/35 A, the alternator conforms to IS:13364 (Part-II) suitable for tropical conditions including making cable connection.
Acoustic Enclousure: Following are some technical features of Acoustic enclosure:- i) The enclosure is modular in construction. ii) Base frame is made of sheet metal. iii) Durable industrial locking system is provided on doors. iv) Door gaskets are made in high quality EPDM material. CORROSION RESISTANCE: To make the enclosure weather proof:- i) All sheet metal parts / components are hot dipped in seven tanks process, pretreated and passivated.
ii) Sheet metal components are with pretreated and passivated base powder coated. iii) Base frame is epoxy coated / powder Coated. iv) Zinc passivated hardwares are used to avoid rusting. ACOUSTIC INSULATION: i) Sound proofing of the enclosure is done with Quality Rockwool confirming to IS:8183 standard. ii) Acoustic foam shall be fire retardant and fire resistant. iii) Attenuates are provided to control sound at entry and exit of container. iv) Specially designed Residential Silencer is provided.
VENTILATION AND AIR CIRCULATION: Exhaust pipe inside enclosure is thoroughly insulated by cladding of rock wool and sheet. ELECTRICAL: Neutral body earthing points at the sides of enclosure are isolated through moulded compound. SAFETIES: Emergency push button to stop the DG set from outside, Low fuel oil level, Low lube oil pressure, Low coolant level, High engine temperature. The canopies being offered are for output of Noise Level ≤ 75 dbA at a distance of 1-meter average, as per the CPCB IV Norms. Batteries: 02 Nos. 12 V Battery 180 AH. Make: Exide with Leads for electric starting. Paint: DG set and panel package will be painted with powder coated type paint.
STANDARD GENSET CONTROLLER UNIT WITH CONTROL PANEL: Genset controller unit with totally enclosed, steel construction control panel suitable for indoor floor / wall mounting installation having standard safeties and display parameters. AMF PANEL Supply, install, testing & commissioning of AMF panel for 100 KVA DG set factory made, outdoor cubical type as per IE/CPRI rules with IP-54 protection, dust and vermin proof, compartmentalised, made of 3.15 mm thick CRCA sheet, fixed on MS angle iron frame of 50 x 50 x 6 mm thick of required type for supporting double door both sides open type with necessary locking arrangement with
slope roof on top duly painted with two coats of powder coated sense grey paint with seven tank process complete and having separate doors inside for accommodating all incoming / outgoing cables and other relevant standards mounted on and including provision of necessary plinth in PCC 1:3:6, type C1 for foundation and PCC pillars with suitable size of nut, bolts & washers grouted as required at site and as per manufacturer's instructions including provision of the following items complete all as specified and directed. Note: Drawing of LT panel board and connections shall be got approved by GE before manufacture of panel board.
(a) Bus bar with electrolytic copper bus bar (for Mains and DG supply incoming and outgoing) suitable for 400 Amps capacity for 3 phase and neutral (TPN) (all connection inside the panel shall be through aluminium strip) connected duly supported with FRP insulators including colour code heat shrinked insulating sleeves. (b) Three phase 4 Pole, Power contractor, 250 Amps for ON-OFF the DG and mains supply - 02 Nos. (c) MCCB 250 Amps, 36KA for ON-OFF the DG and mains supply - 02 Nos. (d) On Load Change over switch 200 Amps for Bypass AMF Panel in case of Power contactor faulty - 01 No.
Earthing with galvanised steel earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25 m deep below ground level with top edge of the plate not less than 1.5 m below normal ground level connected to galvanised earth lead strip 32 x 6 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of SSR Part I connected to earthing test point including excavation / earth work in any type of strata, removal of surplus excavated material, GI pipe for watering and funnel, PCC 1:3:6 type C1 camber with RCC 1:2:4 type B1 in cover slab GI funnel with GI watering pipe 20mm dia medium grade, wire mesh, protection pipe 20mm dia GI pipe light grade for earth lead upto 7.50 m long complete all as specified and directed.
Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit / pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32 x 6 mm dia galvanised iron or steel strip complete all as specified and directed.
SPECIAL ITEM (KITCHEN EQUIPMENT) S&F, stainless steel body flour mixing / dough kneading machine of cap 25 kg, 3 phase 415 V supply, motor capacity 3 HP, bowl material SS food grade of make Samarth Engineers & Consultants or equivalent approved make complete all as specified and directed.
Provision of wall mounted kitchen exhaust system - wall mounted exhaust hoods made of SS sheet, oil filters made of SS sheet, suitable sized ducting in 24 swg GI sheet, suitable exhaust blower 1440 RPM and all accessories like mounting frame, canvas connection, anti vibration pads, all fastners etc., of make Samarth Engineers & Consultants or equivalent approved make complete all as specified and directed.
Provision of fresh air exhaust system SS - 12" dia STD exhaust fans to provide fresh air in kitchen of approved make complete all as specified and directed.
Provision of Hood type Dish Washer of size approx 770x880x1650 mm with dosing pump having tank capacity 28 liters and 21 kW 3 phase 415 V supply all as specified and directed.
Provision of grain storage rack of size approx 450 x 450 x 500 mm, 150 kgs capacity, white color, moisture proof with stand of approved make complete all as specified and directed.
Provision of stainless steel plate storage rack of size approx 1100 x 450 x 1800 mm, colour silver, 5 shelves complete all as specified and directed.
Provision of food warmer, 3 shelves 800 W, 230 V AC supply of 110 Ltr Cap, commercial food warmer of size approx 600 x 450 x 450 mm complete all as specified and directed.
S&F, automatic hand sanitizer spray liquid based machine complete all as specified and directed.
Provision of commercial IDLI steamer with steam generator, full SS 304 grade, capacity 240 IDLI / batch of approved make complete all as specified and directed.
Provision of stainless steel single stone wet grinder capacity 10 Ltrs, 220 V AC supply of approved make complete all as specified and directed.
Provision of air curtain, heavy duty of capacity 20 to 22 M/sec of length 4 feet 600 W, 230 V supply with electro magnatic limit switches of approved make complete all as specified and directed.
Provision of automatic Chapathi making Chapati machine, 600 capacity, full stainless steel body, fully electrically operated, capacity upto 600 pcs/hr of approved make complete all as specified and directed.
Provision of stainless steel centillion electrical Dosa Tawa, 12 kw 3 phase of size approx 900 x 600 x 850 of approved make complete all as specified and directed.
Please Enable Macros to View BoQ information
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.06 MB
Tendernotice_1.pdf
PDF • 0.65 MB
05_WD_PN_AR_549_2025.pdf
Additional Documents • 0.30 MB
BOQ_838572.xls
BOQ • 0.31 MB
81403Tender.pdf
Tender Documents • 2.24 MB
Str_Drgs.rar
Additional Documents • 3.35 MB
04_SP_PN_1504_2025.pdf
Additional Documents • 0.22 MB
15_WD_PN_549_2025_E.pdf
Additional Documents • 0.31 MB
11_WD_PN_AR_549_2025_compressed.pdf
Additional Documents • 0.43 MB
16_WD_PN_AR_549_SOF_2025_compressed.pdf
Additional Documents • 0.58 MB
03_SP_PN_1504_2025.pdf
Additional Documents • 0.22 MB
06_WD_PN_AR_549_2025.pdf
Additional Documents • 0.22 MB
07_WD_PN_AR_549_2025.pdf
Additional Documents • 0.18 MB
08_WD_PN_AR_549_2025.pdf
Additional Documents • 0.32 MB
01_LD_PN_49_2025.pdf
Additional Documents • 0.20 MB
09_WD_PN_AR_549_2025.pdf
Additional Documents • 0.24 MB
10_WD_PN_AR_549_2025.pdf
Additional Documents • 0.23 MB
14_WD_PN_AR_549_2025.pdf
Additional Documents • 0.28 MB
12_WD_PN_AR_549_2025.pdf
Tender Documents • 0.25 MB
81403Prepriced_schedules.pdf
Additional Documents • 0.30 MB
02_SP_PN_1504_2025_compressed.pdf
Additional Documents • 0.36 MB
13_WD_PN_AR_549_2025.pdf
Tender Documents • 0.27 MB
Download all tender documents and submit your bid