Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.4 LAccepted-AOC | ₹4.4 L Quoted ₹4.9 L | L1 | Accepted-AOC Being L1 |
| 2 | L2₹5.0 L+₹13,300 (2.73%)Rejected-Finance | ₹5.0 L+₹13,300 (2.73%) | L2 | Rejected-Finance Not Being L1 |
| 3 | L3₹5.8 L+₹90,700 (18.6%)Rejected-Finance | ₹5.8 L+₹90,700 (18.6%) | L3 | Rejected-Finance Not Being L1 |
| 4 | L4₹8.2 L+₹3.4 L (68.8%)Rejected-Finance | ₹8.2 L+₹3.4 L (68.8%) | L4 | Rejected-Finance Not Being L1 |
| 5 | L5₹8.7 L+₹3.8 L (77.8%)Rejected-Finance 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | ₹8.7 L+₹3.8 L (77.8%) | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹9 L
EMD Value
₹18,000
Closing Date
5 Nov 2024, 6:00 pmClosed
Offg GE I R and D Kanpur
GE I R and D Kanpur DMSRDE Complex, GT Road Kanpur 208013
REPAIR MAINT OF CEILING FAN, WALL FAN, EXHAUST FAN AND OTHER CONNECTED WORKS OF OTM MD ACCN AND MES INSTALLATION OF RAKSHA VIHAR COLONU AREA UNDER GE I R AND D KANPUR
2024_MES_677748_1
8384/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Kanpur
As per Appendix A of NIT
8 documents required · 8 mandatory
₹500
GE I R and D Kanpur
₹18,000
Yes
28 Jan 2025
3 Oct 2024
13 Nov 2024
3 Oct 2024
5 Nov 2024
17 Oct 2024
3 Oct 2024 - 16 Oct 2024
Amount
Taking down ceiling fan of any type, any make and any sweep for repairing, opening the body and blade, checking for replacement of unserviceable spares,cleaning internally and externally, oiling, overhailing, greasing, re-assembling of all components in original position,checking of electric connections, replacement of worn out check nuts, split pins, nuts, bolts and washers, sockets rebber real, clamps and minor repairing works and items etc testing and hanging up the same complete all as specified and as directed by the Engr-in-Charge. Note : New spare parts required for replacement shall be measured and paid seperately
All as per item No 1 above but Exhaust/wall fan any sweep,make and any size complete all as sepcified and direct by Engr-in-charge
M&L for painting of ceiling fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No ceiling fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed
M&L for painting of Exhaust fan of any size sweep including blades and canopies with white enameled approved spray paints one coat after cleaning dust etc and Marking of MES No Exhaust fan such as MES No, and height of letter 2.5 cm in figures including sign writing with black enameled paints all as directed
M&L for removing the burnt copper winding of ceiling fan ,cleaning to cores and rewinding of ceiling fans with copper enameled wire of suitable size including film paper, sleaving and varnishing, 56” (1400mm) complete any make any type as directed by Engr-in- Charge .
All as per item No 5 above but 48”(1200 mm) sweep any make and any size
All as per item No 5 above but exhaust fan 18” sweep 450mm complete any make all as directed by Engr-in- Charge
All as per item No 5 but exhaust fan 12” sweep(300 mm) dia complete
All as per item No 5 but Wall fan 12'' /15" (300 mm/350 mm) dia complete
M&L for renewal of ball bearing suitable size where required and as directed. Make SKF/NBC :- (a) 6201ZZ
M&L for replacement of condensor 2.5 MFD for ceiling fan complete all as specified and directed
M&L for replacement of condensor 3.15/4.00 MFD for ceiling /exhaust fan complete all as specified and directed
M&L for renewal of Gun metal bush where required as directed for ceiling fan or exhaust fan all as directed.
M&L for renewal of shaft suitable for any make of ceiling fans and exhaust fans all as directed.
M&L for replacement of existing ceiling fan down rod with medium grade galvanized iron/ stove enameled pipe 20mm / 15 mm dia including threading both side or MS conduit heavy duty including both end hole with clamp with rubber real and split pin cable entry hole and check nuts including 3 core copper conductor 23/76, PVC insulated wire complete all as specified and directed
Supply & Fixing medium step and socket type fan regulator 80 Watt, 240 Volt AC, ISI marked complete in replacement of old unserviceable resistance type regulator all as specified and directed. Make Anchor/Cona or equivalent in SSK/Crabtree as approved by GE (I).
Supply and fixing as in replacement for PVC insulated unsheathed flexible cord copper wire of size 23/0076 complete all as specified and as directed by the Engr-in-Charge.
S&F in replacement of C/fan blades set of three (56'/48' sweep) make and size as per existing or as required and directed at site by Engr-in-Charge.
All as per item No. 18 above but exhaust fan /wall fan of size 300/450 mm sweep complete all as specified and directed.
M&L in replacement Ceiling fan canopy both upeer and lower complete all as sepcified and direct by Engr-in-charge
M&L Ceiling fan clamp in replacement with rubber real and suitable size of nut and bolt complete all as sepcified and direct by Engr-in-charge
S B ENTERPRISES (BID ID -3157588)
SUSHMANAND ENGINEERING WORKS (BID ID -3152693)
M/S PASHUPATI TRADERS (BID ID -3154449)
DEO Traders (BID ID -3155835)
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .