| 1 | L1₹39.2 LAccepted-AOC 24 SHANTI BHAWAN DHARI ROAD BELTARI PITHORAGARH UTTARAKHAND 262520 | PITHORAGARH | UTTARAKHAND | 262520 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹40.7 L+₹13,658.30 (0.34%)Rejected-Finance BHU | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹41.8 L+₹1.3 L (3.09%)Rejected-Finance 229 CHANDEL MARKET HARJINDER NAGAR KANPUR 208007 | KANPUR | KANPUR | UTTAR PRADESH | 208007 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹43.2 L+₹2.6 L (6.51%)Rejected-Finance | L4 | Rejected-Finance Other than lowest |
| Sl No | Description | Qty | Unit | A.B.Enterprises L3 | smc system & services L4 | shanti trading company L1 | Lalta Prasad vijay kumar Forwarding Agency L2 |
|---|---|---|---|---|---|---|---|
| 1.00 | Removal of air lock / blockage of water in GI tubing 15 mm /20mm/25mm/32mm/50mm bore, cleaning the pipe or fittings etc and re-fixing in the same position complete all as specified and directed Up to 12th storey of building complete all as directed specified. | 100 | Each | 15 ₹1,500 Lowest | 30 ₹3,000 | 30 ₹3,000 | 50 ₹5,000 |
| 2.00 | Petty repairs to leaking water in bib taps, pillar taps stop cock, angle valve, PVC connection waste pipes, float valves, concealed stop cock, GI pipe joints bottle traps etc of any description by changing the washers etc or any other minor accessories to make the system functional complete all as specified and directed by Engr-in-charge. | 300 | Each job | 12 ₹3,600 Lowest | 16 ₹4,800 | 30 ₹9,000 | 40 ₹12,000 |
| 3.00 | Petty reapirs to PVC low level flusing cistern by adjusting the float valve, leakage PVC connection PVC / GI bend incl replacing of rubber washer check nuts plunges float valve complete handles, syphone etc for any type of flush complete all as specified and directed by Engr-in-charge. | 200 | Each job | 45 ₹9,000 Lowest | 80 ₹16,000 | 100 ₹20,000 | 50 ₹10,000 |
| 4.00 | Dismantling of existing sunken treatment including plaster and M&L for water proofing treatment on existing sunken portion with the following step complete all as specified and diirected - (a) 15 mm thick (average) plaster on sunken floor in CM (1:4) with waterproofing compound @ 3 % by weight of cement complete all as specified & directed.(b) M&L for providing two coat of master seal 550 or equivalent to prevent leakage/seepage through sunken floor over prepared surfaces complete all as specified and directed.(c) One spout of 40mm GI Pipe light grade shall be provided in Sunken floor and sunken portion shall be filled with lean concrete 1:5:10 using brick aggregate complete all as specified and directed. Note- Only plan of the floor area shall be measured and paid. | 25 | Sqm | 90 ₹2,250 Lowest | 120 ₹3,000 | 250 ₹6,250 | 1,400 ₹35,000 |
| 5.00 | Supplying and laying of CPVC pipes OUTER DIAMETER 25 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors .CPVC pipes as per IS:15778 are produced in Standard Dimensional ratios SDR 11 Pressure bearing capacity of SDR 11pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² includes all plain CPVC fittings and pipe cutting fixing with CPVC solvent cement and testing complete all as specified and directed. | 20 | RM | 210 ₹4,200 | 170 ₹3,400 | 280 ₹5,600 | 155 ₹3,100 Lowest |
| 6.00 | Supplying and laying of CPVC pipes OUTER DIAMETER 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors .CPVC pipes as per IS:15778 are produced in Standard Dimensional ratios SDR 11 Pressure bearing capacity of SDR 11pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² includes all plain CPVC fittings and pipe cutting fixing with CPVC solvent cement and testing complete all as specified and directed. | 150 | RM | 175 ₹26,250 | 190 ₹28,500 | 250 ₹37,500 | 120 ₹18,000 Lowest |
| 7.00 | Taking up or down 15mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height | 550 | RM | 12 ₹6,600 | 25 ₹13,750 | 20 ₹11,000 | 10 ₹5,500 Lowest |
| 8.00 | Taking up or down 20mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height | 50 | RM | 15 ₹750 | 45 ₹2,250 | 22 ₹1,100 | 12 ₹600 Lowest |
| 9.00 | Taking up or down 32mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height | 400 | RM | 25 ₹10,000 | 50 ₹20,000 | 40 ₹16,000 | 14 ₹5,600 Lowest |
| 10.00 | Taking up or down 50mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height | 200 | RM | 30 ₹6,000 | 50 ₹10,000 | 40 ₹8,000 | 16 ₹3,200 Lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Sept 2025, 6:00 pmClosed
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur-208008
REPAIR/REPLACEMENT OF RUSTED CI/GI PIPES AND ITS CONNECTED ITEMS IN AGV COMPLEX,CHARARI,N-2 ROAD AT AFS CHAKERI KANPUR
2025_MES_728055_1
GE (AF) BR/CHK/T-21 OF 2025-26 8543/A/E8
Open Tender
Civil Works
Item Rate
330 days
GE(AF) B/R Chakeri Kanpur
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE(AF) B/R Chakeri
₹90,000
Yes
11 Dec 2025
27 Aug 2025
6 Oct 2025
27 Aug 2025
29 Sept 2025
10 Sept 2025
Amount
Removal of air lock / blockage of water in GI tubing 15 mm /20mm/25mm/32mm/50mm bore, cleaning the pipe or fittings etc and re-fixing in the same position complete all as specified and directed Up to 12th storey of building complete all as directed specified.
Petty repairs to leaking water in bib taps, pillar taps stop cock, angle valve, PVC connection waste pipes, float valves, concealed stop cock, GI pipe joints bottle traps etc of any description by changing the washers etc or any other minor accessories to make the system functional complete all as specified and directed by Engr-in-charge.
Petty reapirs to PVC low level flusing cistern by adjusting the float valve, leakage PVC connection PVC / GI bend incl replacing of rubber washer check nuts plunges float valve complete handles, syphone etc for any type of flush complete all as specified and directed by Engr-in-charge.
Dismantling of existing sunken treatment including plaster and M&L for water proofing treatment on existing sunken portion with the following step complete all as specified and diirected - (a) 15 mm thick (average) plaster on sunken floor in CM (1:4) with waterproofing compound @ 3 % by weight of cement complete all as specified & directed.(b) M&L for providing two coat of master seal 550 or equivalent to prevent leakage/seepage through sunken floor over prepared surfaces complete all as specified and directed.(c) One spout of 40mm GI Pipe light grade shall be provided in Sunken floor and sunken portion shall be filled with lean concrete 1:5:10 using brick aggregate complete all as specified and directed. Note- Only plan of the floor area shall be measured and paid.
Supplying and laying of CPVC pipes OUTER DIAMETER 25 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors .CPVC pipes as per IS:15778 are produced in Standard Dimensional ratios SDR 11 Pressure bearing capacity of SDR 11pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² includes all plain CPVC fittings and pipe cutting fixing with CPVC solvent cement and testing complete all as specified and directed.
Supplying and laying of CPVC pipes OUTER DIAMETER 20 mm SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors .CPVC pipes as per IS:15778 are produced in Standard Dimensional ratios SDR 11 Pressure bearing capacity of SDR 11pipes @23°C is 28.12kg/cm² & at @82°C 7.03kg/cm² includes all plain CPVC fittings and pipe cutting fixing with CPVC solvent cement and testing complete all as specified and directed.
Taking up or down 15mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height
Taking up or down 20mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height
Taking up or down 32mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height
Taking up or down 50mm dia bore steel tubing and connections complete all as specified and directed. Note -The rate quoted by the contractor shall included upto 12th storey Height
Refixing old steel tubing of 15mm bore and connections in new or old position (walls,cellings, floors etc.) complete all as specified and directed .Note-The rate quoted by the contractor shall included upto 12th storey Height
Refixing old steel tubing of 20 mm bore and connections in new or old position (walls, cellings, floors etc.) complete all as specified and directed.Note-The rate quoted by the contractor shall included upto 12th storey Height
Refixing old steel tubing of 32mm bore and connections in new or old position (walls,cellings, floors etc.) complete all as specified and directed .Note-The rate quoted by the contractor shall included upto 12th storey Height
Refixing old steel tubing of 50mm bore and connections in new or old position (walls, cellings, floors etc.) complete all as specified and directed .Note-The rate quoted by the contractor shall included upto 12th storey Height
S & F 15 mm bore steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in floors including cutting threading and making forged bends on pipes MS hooks etc any position i.e concealed complete all as specified and directed .Note-The rate quoted by the contractor shall included upto 12th storey Height
S & F 20 mm bore steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in floors including cutting threading and making forged bends on pipes MS hooks etc any position i.e concealed complete all as specified and directed.Note-The rate quoted by the contractor shall included upto 12th storey Height
S & F 32 mm bore steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in floors including cutting threading and making forged bends on pipes MS hooks etc any position i.e concealed complete all as specified and directed.Note-.Note-The rate quoted by the contractor shall included upto 12th storey Height
S & F 50 mm bore steel tubing medium grade ,galvanized with all fitting such as bend ,elbow, socket,tees,and fixed complete to wall or in floors including cutting threading and making forged bends on pipes MS hooks etc any position i.e concealed complete all as specified and directed .Note-.Note-The rate quoted by the contractor shall included upto 12th storey Height
S & F in repair OUTER DIAMETER 25 mm SDR 11 fittings CPVC fittings of brass (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor) complete all as specified and directed.
S & F in repair OUTER DIAMETER 20 mm SDR 11 fittings CPVC fittings OF brass (Brass elbow, Brass Tee, Male threaded brass adaptor, Female threaded brass adaptor etc), Unions, Ball valves, Flange and tank adaptor) complete all as specified and directed.
S&F in repair small fitting of galvanized iron medium grade such as socket, elbow, nipple or different sizes Tee, union reducer etc and fixed complete to wall or in floors including cutting threading and making forged bends on pipes MS hooks etc any position for 15mm/20mm bore pipe all as specified and directed.
S&F in repair small fitting of galvanized iron medium grade such as socket, elbow, nipple or different sizes Tee, union reducer etc and fixed complete to wall or in floors including cutting threading and making forged bends on pipes MS hooks etc any position for 32mm/50mm bore pipe all as specified and directed by Engr-in-charge.
S &F in repair 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 20mm-210gms./ 25mm-455gms/ 40mm- 690 gm complete all as specified and as directed. Note-The rate quoted by the contractor shall included upto 12th storey Height
S &F in repair 40mm/50mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 20mm-210gms) complete all as specified and as directed. Note-The rate quoted by the contractor shall included upto 12th storey Height
Cutting chases, pinnng in, in brick walls making good to faciing where required and pointing in cement mortar 1:3 for concealed water tubing, and crossing one side of wall to another side by cutting or drilling exc 10 cm but nt exc 50 cm girth complete all as specified and as directed.Note-The rate quoted by the contractor shall included upto 12th storey Height
S&F in repair gun metal globe or gate valve for 20 mm bore pipe with iron wheel and screwed both ends for iron ppes complte all as specified and as directed.
S&F in repair gun metal globe or gate valve for 32 mm bore pipe with iron wheel and screwed both ends for iron ppes complete all as specified and as directed.Note-The rate quoted by the contractor shall included upto 12th storey Height
S&F in repair gun metal globe or gate valve for 50 mm bore pipe with iron wheel and screwed both ends for iron ppes complete all as specified and as directed.Note-The rate quoted by the contractor shall included upto 12th storey Height
M & L for preparation of OLD painted wooden surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and as directed.
Ditto all as per item No 29 here-in-before but applying on steel surfaces.
Taking down CI,rain water / vent pipes (any size & pattern) including all fittings, heads, noses, bends, swan necks etc including cleaning or repairing or emoval to store, complete all as specified & directed.
S&F of 100/110mm cast iron sand cast soil waste or vent pipes in any length with or without ears with cement joints laid in trenches, floors or fixed to walls etc including making good to match with existing surface complete all as specified and directed Note-.Note-The rate quoted by the contractor shall included upto 12th storey Height
S&F of 50mm cast iron sand cast soil waste or vent pipes in any length with or without ears with cement joints laid in trenches, floors or fixed to walls etc all as directed including making good to match with existing surface complete all as specified and directed Note-.Note-The rate quoted by the contractor shall included upto 12th storey Height
S&F in repair 100/110mm mm bore dia cast iron branches pieces( bends , junction, equal or unequal Y/T(single or doble )coupler,reducer, cowl etc) & oval access doors ,with cement joint, fixed on walls, floors etc , complete in any condition any position complete all as specified and directed.
S&F in repair 50 mm bore dia cast iron branches pieces( bends , junction, equal or unequal Y/T(single or doble )coupler,reducer, cowl etc) & oval access doors ,with cement joint, fixed on walls, floors etc , complete in any condition any position complete all as specified and directed.
S&F in repair for 50/100 mm dia pipe stack clamps out of 50 mm by 5 mm flat iron round iron stays , including bolts and nuts and securing ends of stays to wall or roof pipe any dia complete all as specified and directed .The rate quoted by the contractor shall included upto 12th storey Height
M & L for preparation of OLD decorated plastered surfaces of wall including filling wall care putty where required and applying one coat of oil emulsion distemper complete all as specified and directed.
S&F in repair 150 mm MS pressed handle oval type stove enamelled black complete all as specified and directed.
S&F in repair 200 mm long mild steel barel tower bolt stove enamelled black with bright bolt and fixed, complete all as specified and directed.
S&F in repair 300 mm mild steel sliding door bolts plate type stove enameled black with bright bolt not less than 12mm dia with and incl a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, length of bolt 250mm complete all as specified and directed
S&F in repair 100 mm size butt hinges medium weight cold rolled mild steel complete all as spd & directed.
S&F in repair 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised complete all as specified and as directed by Engr-in-charge.
S & F in repair PVC hinges of 100 mm long complete all as specified and directed.
S&F in repair Aluminium, anodised barrel tower bolt of extruded section of 150mm long complete all as specified and as directed by Engr-in-charge.
S&F in repair Aluminium handles extruded type ,anodised of 150 mm size complete all as specified and as directed by Engr-in-charge.
S&F in repair safety type, brass with mild steel hasp & staple safety type with mild steel hinge pin including bolt to hinge plate and fixed with screws of 100mm length all as specified and directed
S & F in repair of 2nd class hard wood Beads, straight (any size) for glazed or gauzed joinery, renewed, including mitres etc.complete all as speficied & directed
S&F in repair double legged door stopper of aluminium alloy with rubber complete all as specified and directed.
Easing of door /cupboard shutters exc 1.0 Sqm but n.exc 2.0 sqm each for easy closing / opening tightening of hinges or changing the position of hinges adjustment of tower bolts, sliding bolts with new screws etc complete all as specified and directed.
Easing of window shutters n.exc 1.0 Sqm each kitchen cupboard shutters, show case shutter drawers incl fixing of screws adjusting handles, knobs tightening piano hinges incl misc small adjustments complete all as specified and directed.
Hacking out old broken glass (any the size quality or description) from wooden or steel frames glazed all as specified and directed
S&F 3 mm thick sheet glass ordinary quality and galzing with oil putty or wooden beads in squares of any size complete all as specified and directed
S&F 3mm thick figured glass pin head type and glazing with oil putty or wooden beads in squares n exc 0.50 Sqmtr each pane complete all as specified and directed by Engr-in-charge.
S & F in repairs Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples or nails complete all as specified and directed.
S&F in repair mild steel helical door spring 300 mm ordinary rat tail type incl roller and roller plate complete fixed with screws to wooden frames or with welding to steel frames complete all as specified and directed.
S&F in repair Plain colour 1mm PVC sheet fixed or laid on window by using steel winding wire complete all as specified and directed by Engr-in-charge.
Taking down Shutters of any description but not exc 2 sqm each complete all as specified and directed.
M & L for 35 mm thick factory made Second class hard wood glazed and skelton shutters open rebated and prepared to receive glass, gauze /wire mesh etc with sash bar any number fitted with cut and mitered beads for securing glass gauze etc, sizes of members of shutters as specified in SSR Part I section 8, Section 8.24(a) and fitted to chowkats complete all as specified and as directed.
S & F Stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and ply wood face panels, commercial type on both sides complete, all as specified and directed.
S&F Butt hinges of 100 mm size, medium weight, cold rolled mild steel and fixed complete all as specified and directed.
S&F 200 mm mild steel barrel tower bolts, stove enamelled black, with bright bolt and fixed complete all as specified and directed.
S&F 150 mm Mild steel pressed handles, oval type, stove enamelled blackcomplete all as specified and directed.
S&F 300 mm long mild steel sliding door bolts, ISI marked clip type, stove enamelled black, with bright bolt not less than 12 mm dia with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate and fixed complete all as specified and directed
M & L for preparation of new wooden surfaces of any description exceeding 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed.
M&L for cleaning of RCC water tank over 9 to 12 storey building of AGV area with 35000 to 45000 ltr capacity including removal of all deposited scales, dirt and settled sand particals and cleaning with brushing, sweeping and brooming of inner wall (incl partition wall b/w the tank) of the tank and washing the complete with bleaching powder solution and three coat of lime coating in inner wall and writing the date of cleaning with synthetic enamel paint on the tank etc all as specify and directed by EIC. Note. 1. work shall be carried out with trained staff with hygeine and safety equipment. 2. Sand, silt other material shall be thrown out side of MD land as per direction of EIC.
M&L for cleaning of RCC water tank over 9 to 12 storey building of AGV area with 12000 to 15000 ltr capacity including removal of all deposited scales, dirt and settled sand particals and cleaning with brushing, sweeping and brooming of inner wall of the tank and washing the complete with bleaching powder solution and three coat of lime coating in inner wall and writing the date of cleaning with synthetic enamel paint on the tank etc all as specify and directed by EIC. Note. 1. work shall be carried out with trained staff with hygeine and safety equipment. 2. Sand, silt other material shall be thrown out side MD land as per direction of EIC.
S&F in repairs 15mm bore chromium plated cast copper alloy bib taps fancy type with flange complete all as specified and directed.
S&F in repairs 15mm bore chromium plated cast copper alloy pillar cock complete all as specified and directed.
S&F in repairs 15mm bore angle valves, cast copper alloy fancy type chromium plated with flange complete all as specified and directed.
S&F in repairs 15 mm bore concealed/open stop valves, cast copper alloy fancy type chromium plated with flange complete all as specified and directed.
S&F in repair chromium plated overhead shower multiflow with shower arm 225 mm (with flange) complete all as specified and directed.
S&F in repairs brass chromium plated towel rail of 450 mm long complete all as specified and directed
S&F in repair PVC connections 15mm size with PTMT nuts of length 450/600 mm, complete all as specified and as directed.
S&F in repair waste fittings brass,chromium plated for WHB with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed of size 32 mm, dia complete all as specified and as directed.
S&F in repair waste fittings brass,chromium plated for sink with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed of size 40 mm, complete all as specified and as directed.
S&F in repairs PVC waste pipe 32 mm dia, 800/900 mm long, complete all as specified.
S&F in repairs PVC waste pipe 40 mm dia, 800/900 mm long, complete all as specified.
S & F in repair 10 litre capacity, PVC valveless, symphonic action type, flushing cistern, low level , white with inlet, ball valve float, and handle including brackets and connections to pipes, complete all as specified and as directed.
S&F in repairs internal flushing kit of PVC low level flushing cistern and making in functional complete all as specified and dircted .
S&F in repair 100mm / 125mm dia mild steel chromium plated grating with or without waste hole fixed on floor trap / nahani trap in CM 1:6 all as specified and directed by Engr-in-charge.
S & F in repair Vitreous china wash basin , white , flat back, size 550 x 400 mm, excluding taps waste ,chain and plug and porcelain stopper but incluing brackets, and cutting for and pinning in ends of brackets or errecting stand, complete all as specified and as directed.
S&F in repair plastic water closet seat cover colour/ white, closed pattern with flat bottom and MS CP or aluminised hinging device complete all as specified and directed.
S & F in repair Vitreous china squatting pan 'orrisa' pattern size 580 x 440 mm white integral floot rests ( excluding flushing cistern ) including connection to trap and to flushing pipe anti syphonage pipe etc complete including making good to floor, complete all as specified and as directed.
S&F in repair vitreous china wash down water closet pedestal pan white excluding flushing cistern and flush pipes complete all as specified and as directed .
S&F in repairs health faucet cock brass chromium plated including 1M long flexible pipe of chromium plated complete all as specified and directed
S&F in repair MS brackets for WHB/kitchen sink including taking out of existing WHB and kitchen sink and fixed in same position including making good etc complete all as specified and directed.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed
Dismantling floor, hearth or wall tiling including cement mortar bedding but not backing , removing serviceable tiles to store and rubbish off the premises complete as directed.
Refixing of Shutters of any description(pvc/wooden) exc 1 sq. m and n exc 2 sq. m each (Note-The item for 'refixing' includes taking down, easing and adjusting and also refixing builders hardware as required)
M&L Coloured Glazed digital ceramic tiles(350x250)x7 mm/ (450x350)x7mm thick or as required size of 7 mm thick vertical surface as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles over and including 15 mm thick screed bed in CM 1:6 complete all as specified and directed.
M&L non skid ceramic digital tiles 7 to 8 mm thick (Square/ rectangular) area of each tile exceeding 0.09 sqm but not exceeding 0.16 sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match coloured tiles over and including 10 mm thick plaster in CM 1:4 complete all as specified and directed..
Dismantling stone slabs and tiles of any description or thickness, laid, bedded and pointed in any mortar as in floors, aprons etc complete all as specified and directed.
M&L screed bed or bedding layer or mortar 20 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
M&L for 18 - 20 mm thick granite (of any type) work (table rubbed and polished) in steps jambs, pillers, window -cills cooking platforms and like in cement mortal (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite, cutting and moulding edges complete all as specified and directed.
Demolition of Cement concrete (Unreinforced) n exe 15 cm thickness (below or above ground level) complete all as directed.
M&L 25mm thick cement concrete type B0, 1:2:4, (using 12.5 mm graded stone aggregate) as in sub base for floor complete all as specified and directed.
M&L for 75mm thick PCC 1:3:6 type C-2 (using 40mm graded stone aggregate) as in floor/plinth protection/sub base , finish even & smooth without using extra cement all as specified and directed.
Taking down chowkats or frames not exc 1.5 sqm each but with shutters (without taking off shutters from the frame) complete all as specified and directed.
S&F wood grain printed PVC sheet PVC door frame of size 50 mm x47 mm made out of 5 mm colour PVC sheet reinforced with MS tube , fixed in opening complete all as specified and directed .
S&F factory made both side prelaminated solid panel PVC door shutter 30mm thick (style) considting of frame made out of M.S tubes for top & bottom rails M.S frame shall be covered with heat moulded plain colour PVC 'C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail &bottom rail on either side & as gap insiert for top rail& bottom rail, panelling of double side prealm PVC sheet to be fitted in the M.S frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and jointed together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed by Engr-in-charge.
S&F 100 mm size butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised complete all as specified and as directed by Engr-in-charge.
S&F Aluminium, anodised barrel tower bolt of extruded section of 150mm long complete all as specified and as directed by Engr-in-charge.
S&F Aluminium handles extruded type ,anodised of 150 mm size complete all as specified and as directed by Engr-in-charge.
Taking down cement plaster on Brick or Stone,concrete walls ,ceiling etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 10 mm thick in cement plaster (1:6) on fair faces of brick work or concrete surfaces , finished even and smooth without using extra lime or cement complete all as directed by the Engr-in-Charge.
M&L for rendering 5 mm thick in cement mortar 1:3 on ceiling of brick or concrete surface, finished even and smooth without using extra lime or cement complete all as directed by the Engr-in-Charge.
M&L for preparation of OLD undecorated surfaces of walls/celing and applying one coat of cement based paint , all as specified and directed.
M&L for applying 2mm thick wall care putty on newly plastered surface of wall/celing and applying two coat of oil bound distemper over a coat of primer on wall complete all as specified and directed.
Note for Item No 1 to 111 (a) The contractor shall be employee adequate numbers of of skilled tradesman/labour for timely completion of the complaint as per time frame given below and work to be executed upto UPTO 12TH Storey (b) All T&P, safety equipments and other items required at site under subject contract shall be provided by Contractor. Cost of temporary supports such as Props, Jacks, Scaffolding, Shuttering etc as up to 12th storey required for each individual case component wise is deemed to be included in unit rates quoted. (c) Adequate safety arrangement need to be ensured to avoid accidents/mishap & cost of same is deemed to be included in unit rates quoted. (i) Priority-I : Complaints pertains to major water leaks, air locks, flushing cistern will be attended on priority-I and the same will be completed within 4 to 8 hrs. (ii) Priority-II : Compaints pertains to minor water leaks, re-glazing of door and windows, easing of joinery will be attended on priority-II and the same to be completed within 48 hrs. (iii) Priority-III : Compaints pertains to water proofing of roof, repair of sunken slab, minor plaster work, re-flooring, replacement of joinery minor etc will be attended on priority-III and the same to be completed within one week. (iv) Priority-IV : Major plastering, reflooring, plinth ptotections, brick work etc will be attended on priority-IV and the same to be completed within one month. (v) Contractor or his supervisor shall collect the complaint/job card from JE concerned between 0900 hrs to 1000 hrs on all working days and deposited the same after completion of job duly signed by user/occupants. (vi) Summary of complaints will prepared by the contractor and put up to Engineer-in-Charge last date of every month. (vii) If contractor shall not attend the complaint as per time frame given in Para (i) to (iv), Rs 500/- per complaint will be recovered from the RAR/Final bill.
Lalta Prasad vijay kumar Forwarding Agency (BID ID -3431646)
A.B.Enterprises (BID ID -3438457)
smc system & services (BID ID -3438564)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .