Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.8 LAccepted-AOC 1001 63 SHALIMAR GARDEN ISMAILGANJ NEAR INDIRA NAGAR SECTOR 08 CROSSING LUCKNOW 226016 | LUCKNOW | UTTAR PRADESH | 226016 | L1 | Accepted-AOC Being the lowest tenderer and fulfilling all the criteria | |
| 2 | L2₹29.0 L+₹4.1 L (16.7%)Rejected-Finance 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | L2 | Rejected-Finance Not being the lowest tenderer | |
| 3 | L3₹30.7 L+₹5.8 L (23.2%)Rejected-Finance | L3 | Rejected-Finance Not being the lowest tenderer | |
| 4 | L4₹32.3 L+₹7.5 L (30.0%)Rejected-Finance NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | L4 | Rejected-Finance Not being the lowest tenderer | |
| 5 | L5₹45.1 L+₹20.2 L (81.3%)Rejected-Finance D 3 7TH BLOCK JAIN GREEN ACRES DHARGA ROAD ZAMIN PALLAVARAM CHENNAI 600043 | CHENNAI | CHENNAI | TAMIL NADU | 600043 | L5 | Rejected-Finance Not being the lowest tenderer |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
31 Aug 2021, 6:00 pmClosed
GE Chennai
Fort Saint George, Chennai
REPAIRS REPLACEMENT OF LT UG CABLE AND ITS ALLIED WORKS AT ZONE C AND E AREA UNDER GE CHENNAI
2021_MES_464837_1
8531/E8
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
Fort Saint George
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Chennai
₹70,000
Yes
6 Oct 2021
3 Aug 2021
7 Sept 2021
3 Aug 2021
31 Aug 2021
17 Aug 2021
Amount
BOQ UPLOADED ON 11 AUG 2021
Excavation in trenches in soft/ loose soil n. exc. 1.50m wide and n. exc. 1.50m deep for taking out/ laying cables, CI/ GI/ DI/ HDPE pipe line and getting out complete all as specified and directed.
Returning filling in including spreading, leveling, watering & well ramming in layers not exceeding 25cm thick in soft/ loose soil complete all as specified and directed.
Removing excavated soil not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Supply, laying in trenches clean dry sand to required width and depth at bottom and top of cable including spreading, levelling, punning for laying/ cushioning of cable all as specified and directed. Note: Punned thickness only will be considered or payment.
Supply and laying burnt bricks, old size, sub class 'B', laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and directed.
Laying only old size burnt bricks, laid flat abutting each other, perpendicular to cable with width equal to width of brick laid in trenches for protection of cable all as specified and as directed. Note: Old re-useable bricks obtained during taking out of cable shall be re-used.
Taking out existing PVC/ XLPE cable 1100 volts grade LT cable of size 6 sqmm 2 core with glands, bricks/ cable protection pipe, cable route indicators etc. from the trench/ fixed along wall or passing through pipes/ in floor, removing the unserviceable/ faulty cable and stacking serviceable cable for re-use complete all as specified and directed. Note: Excavation and earthwork will be measured and paid separately under appropriate items.
All as per item No. 7.00 above but cable size 10 sqmm 2 core.
All as per item No. 7.00 above but cable of size 25 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 7.00 above but cable of size 240 sqmm 3½ core.
Laying only old serviceable cable of size 25 sqmm 3½ core including jointing, testing and commissioning complete all as specified and directed. Note: Old serviceable cable as obtained from taking down shall be re-used after testing as directed by Engineer-in-Charge.
All as per item No. 16.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 16.00 above but cable of size 240 sqmm 3½ core.
Supply and laying in trenches, fixed on wall (or) passing through pipes/ in floors including connecting up, testing and commissioning of XLPE insulated screened PVC bedded galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6 Sqmm 2 core complete all as specified and directed.
All as per item No. 23.00 above but cable size 10 sqmm 2 core.
All as per item No. 23.00 above but cable of size 25 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 35 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 50 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 95 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 150 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 185 sqmm 3½ core.
All as per item No. 23.00 above but cable of size 240 sqmm 3½ core.
M&L cable jointing kit for 1100 volts grade cable for straight through heat shrink type joints complete with jointing material and accessories suitable for 25 sqmm to 50 sqmm 3½ core XLPE armoured aluminium conductor cable complete all as specified and directed.
All as per item No. 32.00 above but for 95 sqmm 3½ core cable.
All as per item No. 32.00 above but for 150 sqmm to 185 sqmm 3½ core cable.
All as per item No. 32.00 above but for 240 sqmm 3½ core cable.
Supply and laying GI tube light grade 50mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 80mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply and laying GI tube light grade 100mm bore with all fittings laid in trenches/ floor for cable protection and for drawing earth strip/ earth lead wire etc., complete including taking down old pipe complete all as specified and directed.
Supply, fix, connecting and testing MCCB three pole 125 Amps, 415 volts breaking capacity, 16kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed. Make: Havells Cat No. IHA13EBF0125# or equivalent from other makes specified in Particular specifications.
Supply, fix, connecting and testing MCCB four pole 160 Amps, 415 volts breaking capacity, 36kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed. Make: Havells Cat No. IHA13EBF0160# or equivalent from other makes specified in Particular specifications.
Supply, fix, connecting and testing MCCB four pole 200 Amps, 415 volts breaking capacity, 36kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed. Make: Havells Cat No. IHA13EBF0200# or equivalent from other makes specified in Particular specifications.
Supply, fix, connecting and testing MCCB four pole 250 Amps, 415 volts breaking capacity, 36kA with adjustable thermal and magnetic setting including taking down the existing one complete all as specified and directed. Make: Havells Cat No. IHA13EBF0250# or equivalent from other makes specified in Particular specifications.
S&F ONLOAD change over switch in sheet steel enclosure with side handle, 4 pole, compact design type 415V AC, 50 Hz, 100 Amps including taking down old change over switch complete all as specified and directed. Make: Havells Cat No. IHBFFE0100 or equivalent from other makes specified in particular specifications.
S&F OFFLOAD change over switch in sheet steel enclosure with side handle, 4 pole, compact design type 415V AC, 50 Hz, 200 Amps including taking down old change over switch complete all as specified and directed. Make: Havells Cat No. IHBFFE0200 or equivalent from other makes specified in particular specifications.
S&F street light panel, 3 phase, digital 24 hours timer with 32 Amp TP contactor and 40 Amp TPN MCB provided with inbuilt circuit protection with protection degree IP 54 suitable for 6 KW load including taking down old street light panle complete all as specified and directed. Make: Havells Cat No. IHXTS03060 OR equivalent from other makes specified in particular specifications.
S&F street light panel, 3 phase, digital 24 hours timer with 65 Amp TP contactor and 63 Amp TPN MCB provided with inbuilt circuit protection with protection degree IP 54 suitable for 12 KW load including taking down old street light panle complete all as specified and directed. Make: Havells Cat No. IHXTS03060 OR equivalent from other makes specified in particular specifications.
M&L for 60mm thick M-35 grade machine pressed precast concrete interlocking paver block any shape and size conforming to IS: 15658-2006 with grey cement and no pigment laid as per manufacturer's instructions complete all as specified and directed.
M&L for preparing old painted steel surface (LT panel of any size and type) of any description over 10cm width or girth and applying two coats of synthetic enamel grey colour paint after thoroughly burning the existing paint including repairing the LT panel door by tack welding as required complete all as specified and directed.
M&L painting to LT steel tubular poles 8.5/ 9Mtr long including all fittings and fixtures complete, fixed with poles with one coat of aluminium paint after scrapping of rust and preparation of surfaces complete all as specified and directed.
M&L for writing letters in figures with synthetic enamel paint (Block, Roman, Italic & Indian) n. exc. 30cm height all as specified and directed.
Supply and fixing GI earth strip of size 25mm x 4mm fixed with nuts and bolts of suitable size as in earth lead including taking down old strip complete all as specified and directed.
Supply, install, test & commissioning LT panel outdoor, floor mounted/ pedestal type, cubical, self supported, CPRI approved make, front and rear openable, double door hinged type with locking arrangement and suitable ventilations on both sides with wire mesh, IP-65 protection, fabricated out of 3mm CRCA sheet duly powder coated, mounted/ fixed on and including MS angle iron stand of 50cm height above ground, fabricated out of 50mm x 50mm x 6 mm thick MS angles duly painted with black enamel synthetic paint over a coat of red oxide primer duly grouted in PCC (1:3:6) type C-2 using graded stone aggregate as in foundation, control wiring copper stranded PVC insulated FRLS cables not less than 1.5 sqmm, interconnection of suitable size/ capacity of copper strips for switch gear connection from main bus bar four run including earth bus strip of 200A capacity for entire length of panel, suitable size of MS gland with gland plate and aluminium lugs/ thimbles for all incoming/ outgoing cables etc. complete including taking down the old panel and accommodating the followings:
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.3mm thick buried directly in ground vertically to a depth of not less than 2.25 mtr below normal ground level with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to ganvanised iron strip of size 25 x 4mm as earth lead by means of bolts, nuts and washers of galvanised iron, protected by means of 40mm dia light grade GI pipe all as specified and shown in MES schedule electrical plate No. 3 of SSR (Part-I) including necessary excavation and earth work in soft/ loose soil, PCC (1:3:6) type C-1 in chamber, 50mm thick RCC (1:2:4) type B-1 cover slab with 8mm dia MS bars at 100mm centre to centre both ways and MS 6mm dia hook, charcoal dust, salt, funnel for watering complete and testing the earth resistance and writing on the chamber by paint including demolition of existing earthing complete all as specified and as directed.
EVEREST ENGINEERING WORKS
RADHIKAGANESH ENTERPRISES
PSK Enterprises
lakshmibuilders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .