Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹9.0 L+₹91,066 (11.3%)Rejected-Finance HIMACHAL PRADESH HP | KULLU | HIMACHAL PRADESH | 172023 | L2 | Rejected-Finance L2 |
Tender Value
₹9.1 L
EMD Value
₹18,200
Closing Date
31 Jan 2026, 5:00 pmClosed
EE
Electrical Division No.II, HPPWD, U.S. Club, Shimla-01.
Providing rewiring E.I. and replacement of safety devices in Court Complex building at Theog District Shimla.
2026_PWD_126471_1
ED.II.TA.TENDER.25.26.3183 dt. 21.01.2026
Open Tender
Electrical Works
Percentage
30 days
Theog
Please refer to tender documents. Eligibility criteria is mentioned at page No. 9-10 of GCC. Documents mentioned in eligibility criteria must be uploaded to qualify the bid.
7 documents required · 7 mandatory
₹350
₹18,200
19 Mar 2026
24 Jan 2026
2 Feb 2026
24 Jan 2026
31 Jan 2026
24 Jan 2026
Rewiring for light point/ fan point/exhaust fan point/call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.:
76.03:Group C
Rewiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required.:
:Twin Control
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.:
11.03:3 x 1.5 sq. mm
11.06:3 x 2.5 sq. mm
11.09:3 x 4 sq. mm
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.:
10.04:2 X 6 sq. mm + 1 X 6 sq. mm earth wire
10.05:2 X 10 sq. mm + 1 X 6 sq. mm earth wire
10.08:4 X 10 sq. mm + 2 X 6 sq. mm earth wire
Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.:
18.01:1 or 2 Module
18.02:3 Module
18.03:4 Module
18.04:6 Module
18.05:8 Module
18.06:12 Module
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.:
16.01:5/6 amps switch
16.02:2 way 5/6 A switch
16.03:15/16 A switch
16.04:3 pin 5/6 A socket outlet
16.05:6 pin 15/16 A socket outlet
16.08:Bell push
Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required.:
S/E of LED Downlighter surface square with CRCA/PDC body and diffuser The fitting should be installed on existing surface The job includes carriage, erection, making connections testing and commissioning of the fittings.:
Specification of LED fittings::
Wattage of LED fittings :As per following parameter.
Lumen output of the fitting:as below
Diffuser : Polycarbonate diffuser/pmma
Operating voltage :140 V to 270 V, AC supply or better.
Input frequency :50 Hz + 1 Hz
Power factor :Minimum 0.90
Luminaire efficacy :>85 lm/w
Color rendering index:CRI shall be greater than 80
Working/ operating temperature :00 to + 450c or better
Color temperature :60000K + 10%
Electronic Driver :
Drive current (LED):As per OEM.
Operating voltage :140 V to 270 V AC supply or better
Type of driver :Constant current output driver
THD :Less than 10%
Surge Protection :2.5 KV minimum
Efficiency Driver:>85%
Protection:Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver :2 years against manufacturing defect.
Fixture :Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model:Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED:50000 burning hours at 70% lumen maintenance
S/E of LED Panel with PDC body and prismatic diffuser to be mounted in recess The job includes carriage, erection, making connections testing and commissioning of the fittings.2 * 2 feet:
Specification of LED fittings::
Wattage of LED fittings :As per following parameter.
Total lumens of the fittings. :as below
Diffuser : Prismatic multilayer diffuser UGR <19
Operating voltage :140 V to 270 V, AC supply or better.
Input frequency :50 Hz + 1 Hz
Power factor :Minimum 0.90
Luminaire efficacy :>120 lm/w
Color rendering index:CRI shall be greater than 80
Working/ operating temperature :00 to + 450c or better
Color temperature :60000K + 10%
Electronic Driver :
Drive current (LED):As per OEM.
Operating voltage :140 V to 270 V AC supply or better
Type of driver :Constant current output driver
THD :Less than 10%
Surge Protection : 2.5 KV minimum
Efficiency Driver:>85%
Protection:Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver :2 years against manufacturing defect.
Fixture :Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model:Power CREE/ OSRAM/ NICHIA/ Philips LUMILED havell .Panosonic ,Wipro Chengi etc with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED:50000 burning hours at 70% lumen maintenance
S/E of LED Batten with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.:
Specification of LED fittings::
Wattage of LED fittings :As per following parameter.
Total lumens of the fittings. :as below
Diffuser : Polycarbonate diffuser/PMMA
Operating voltage :140 V to 270 V, AC supply or better.
Input frequency :50 Hz + 1 Hz
Power factor :Minimum 0.90
Luminaire efficacy :>100 lm/w
Color rendering index:CRI shall be greater than 80
Working/ operating temperature :00 to + 450c or better
Color temperature :60000K + 10%
Electronic Driver :
Drive current (LED):As per OEM.
Operating voltage :140 V to 270 V AC supply or better
Type of driver :Constant current output driver
THD :Less than 10%
Surge Protection :2.5 KV minimum
Efficiency Driver:>85%
Protection:Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver :2 years against manufacturing defect.
Fixture :Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model:Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 25,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED:25000 burning hours at 70% lumen maintenance
Lumen output of the fitting:Rate
Providing and installation exhaust fan of following sizes in the existing opening, Double ball bearing type metal frame including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required: of Approved Make Domestic type.:
66.02:Exhaust Fan, Light duty, (Domestic) 225/230 mm sweep
66.03:Exhaust Fan, Light duty, (Domestic) 300 mm sweep
S/E of LED Bluk head fitting with polycarboante body and diffuser The fitting should be installed on existing surface/recess The job includes carriage, erection, making connections testing and commissioning of the fittings.:
Specification of LED fittings::
Wattage of LED fittings :As per following parameter.
Total lumens of the fittings. :as below
Diffuser : Polycarbonate diffuser/PMMA
Operating voltage :140 V to 270 V, AC supply or better.
Input frequency :50 Hz + 1 Hz
Power factor :Minimum 0.90
Luminaire efficacy :>80 lm/w
Color rendering index:CRI shall be greater than 80
Working/ operating temperature :00 to + 450c or better
Color temperature :60000K + 10%
Electronic Driver :
Drive current (LED):As per OEM.
Operating voltage :140 V to 270 V AC supply or better
Type of driver :Constant current output driver
THD :Less than 10%
Surge Protection :2 KV minimum
Efficiency Driver:>85%
Protection:Shall have under voltage and over voltage protection.
Guarantee of LED fittings including LED driver :2 years against manufacturing defect.
Fixture :Should comply with LM 79 test from UL/NABL lab.
LED Type/ Make/ Model:Power CREE/ OSRAM/ NICHIA/ Philips LUMILED with life more than 50,000 burning hours @70% lumen maintenance complying with LM 80 test report from the manufacturer.
Life of LED:50000 burning hours at 70% lumen maintenance
Lumen output of the fitting:1100
S/E of MCCB 4 Pole 415 Volt. with Microprocesser Release for overload and short circuit protection breaking Capacity (Ics=100% Icu with positive isolation) with/ without Spreader/ Rotary Handle.:
30.03:MCCB 125/160 Amp. 36 ka 4 Pole Release with rotary handle
Supplying and fixing TP&N copper bus-bar chamber suitable for 415 volts capacity with 4 No. copper strip bus-bars each of length and x-section suitable for following current carrying capacities, enclosure made of sheet steel having thickness of 1.6mm, dust protected, duly powder painted with detachable gland plate and other accessories including drilling holes on the board, making connections, earthing etc. as required.:
43.02:100 A Copper Busbar Chambers 15" (SS Enclosure)
Providing and fixing following rating, four pole, 415 volts, On-Load change over switch unit, in sheet steel enclosure, with side handle operation, including drilling holes on the board, making connections, etc. as required:-:
42.02:100 amps. TPN, On Load Change over switch (SS Enclosure type)
S/E of MCCB 4 Pole 415 Volt. with Microprocesser Release for overload and short circuit protection breaking Capacity (Ics=100% Icu with positive isolation) with/ without Spreader/ Rotary Handle.:
30.01:MCCB 40- 100 Amp. 36 ka 4 Pole Release with rotary handle
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator):
32.02:8 way , Double door
32.03:12 way , Double door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.:
2.01:Single pole
Supplying and fixing following rating, followings poles 10ka 240/415v 'C' curves miniature circuit braker suitable for inductive load of following poles in the exsisting MCB DB complete with connections, testing and commissioning etc. as required.:
Providing and laying of one number additional PVC insulated and PVC sheathed armoured / XLPE power cable of 1.1 KV grade of following size direct in cable tray including accessories clamping.:
72.01:Armoured cable 6 sq. mm (twin core)
72.02:Armoured cable 10 sq. mm (twin core)
Supplying and Fixing New generation IP 65 led Post Top family energy saving environmental friendly long life aesthetically designed with sysmetrical light distribution spun aluminum landscape luminiare with high power LED s as light sourace clear cover offer bright illumination for different applications at the top of existing pole including painting the pipe with two coats of approved paint over priming coat complete in all respects as required:- make Havell Wipro or its equilant make as directed by Er -in -charge .:
LED Post Top light 45 watt :
Providing and fixing two hencel box for street light with MCB SP 6 AMP 1nos as reqd complete in all respect. :
Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required.:
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.:
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.:
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.:
Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required.:
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For horizontal run):
Providing and fixing G.I. tape 20 mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required.(For vertical run):
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_186493.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.75 MB
GCC.pdf
Tender Documents • 4.69 MB
BOQ_186493.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .