Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.1 LAccepted-AOC 114 SHASTRI NAGAR MEERUT | MEERUT | UTTAR PRADESH | 245206 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹38.1 L+₹4.4 L (13.1%)Rejected-Finance 64 250 2 COD ROAD HASTINAPURI MADHU NAGAR AGRA 282001 | AGRA | AGRA | UTTAR PRADESH | 282001 | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹44.3 L+₹10.6 L (31.5%)Rejected-Finance 34 1 12 2F SAINIK VIHAR DEORI ROAD AGRA UP 282007 | AGRA | UTTAR PRADESH | 282007 | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹44.5 L+₹10.8 L (32.1%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹44.9 L+₹11.2 L (33.4%)Rejected-Finance | L5 | Rejected-Finance Other than lowest |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
29 Jun 2023, 6:00 pmClosed
Maj Ashwin Awadh
GE West Agra (West) 62 Station Road Agra Cantt
REPAIR REPLACEMENT OF CEILING LIGHT/ HIGHBAY LIGHT, INTERNAL WIRING, LIGHTENING CONDUCTOR AND EARTHING ALONGWITH OTHER CONNECTED ITEMS AND FIXTURES OF COD AGRA UNDER AOR OF GE(W) AGRA.
2023_MES_598532_1
8012/951/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE West Agra
₹90,000
15 Sept 2023
27 May 2023
1 Jul 2023
27 May 2023
29 Jun 2023
12 Jun 2023
Amount
Taking down carefully copper/aluminium point wiring on batten/ PVC conduit (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etcexcluding tubelight fittings etc, including removal and making good disturbed surfaces of walls, ceilings etc by cement/colour/plaster to match with the existing location spot complete all as specified & directed by Engr-in-Charge.
M&L for point wiring complete for One light/Fan/Exhaust Fan point controlled by one switch with PVC insualted and unsheathed FRLS cable 1.5 Sqmm (nominal area) ISI marked, multi-stranded copper conductor single core including ISI marked 20 mm dia PVC conduit medium grade concealed in wall and PVC conduit not less than 20 mm in roof / floor slab and ceiling, pressed GI concealed terminal boxes not less than 1.6 mm thick of required size and with top cover 3 mm thick of plastic laminated sheets of requied colour complete, including 1.5 Sqmm PVC, FRLS cable insulated unsheathed copper earth wire to the common earth and connecting to earth dolly, including colour coding of cable shall be Phase-red, Neutral-black and Earth- green with all accessories complete all as specified and directed by Engr-in-Charge.. (Note :- In case of roof/ceiling, heavy duty PVC pipe shall be used without any extra cost.)
All as above item No-2 here in before but one socket out let 3/5 pin, 5/6 Amps controlled by one way switch on independent board but not below the switch board of light points complete all as specified & directed by Engr-in-Charge.
All as per item No-2 here in before but one socket out let 3/5 pin, 5/6 Amps controlled by 1 one way on the same board with other switches complete all as specified & directed by Engr-in-Charge.
all as per item No-2 here in before but point wiring for one six pin socket outlet 15 & 5 amps (independent) controlled by one modular switch using PVC FRLS cable of size 2.5 sqmm complete all as specified & directed by Engr-in-Charge. NOTE-For item no 2 to 5 -: (i)The quoted rates shall be deemed to be inclusive for cutting chases in brick wall/pillers etc for concealing the conduits to required depth & making good the disturbed surfaces in cement mortar 1:4 including finishing the surface to match with the existing surface.The portion of point wiring at RCC beams/ coloumns /ceilings etc shall be in surface steel conduit of suitable size fixed on surface with using PVC rawl plug. (ii) Fittings like switches,sockets,regulators,lamp holders,light foittings shall be measured and paid for separately under appropriate item of schedule A. (iii)The size of conduits shall be determined on permissible no of runs of wires as specified in SSR part-I clause 19.125 (B).However minimum size of conduit shall be 20 mm dia (medium grade)
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed by Engr-in-Charge.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed by Engr-in-Charge.
Supply and fix switch piano, flush type, single pole, 20 Amps one way, 230 volts complete all as specified and directed by Engr-in-Charge.
Supply and fix socket outlet, multi-purpose 3 pin 5/6 Amps and 3 pin 15/16 Amps complete all as specified and directed by Engr-in-Charge.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed by Engr-in-Charge.
S&F switch, bell push button, single pole, 5/6 Amps, one way, 230 Volts complete all as specified and directed by Engr-in-Charge.
Supply & fix in replacementsingle pole and neutral sheet metal enclosure (AC box) with a two pin & earth plug and socket with one no. MCB SP of capacity 20 Amps 240 volts IK-08 As per IEC 61439-3 complete all as specified & directed by Engr-in-Charge.
Supply and fix in replacement lamp holder insulated body with back plate for batten fitting complete all as specified and directed by Engr-in-Charge.
Supply & fix rotory stepped type electronic fan regulator mini flush type 100 watt 230 Volts complete all as specified & directed by Engr-in-Charge.
Supply and fix in replacement electrical bell model city ding dong (Ding dong type) AC, 230 Volts complete all as specified & directed by Engr-in-Charge.
Taking down care fully sub main wiring / service connections of any size including batten/ conduit, and making good the disturbed surfaces of wall/ floor complete all as specified & directed by Engr-in-Charge.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 10 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 10 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed. Note:- Finished sub main wiring with two runs of 10 sqmm cable & one run of 10 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length complete all as specified & directed by Engr-in-Charge.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 6.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 6.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed complete all as specified & directed by Engr-in-Charge.Notes:- Finished sub main wiring with two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 4.0 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 4.0 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed.Notes:- Finished sub main wiring with two runs of 4.0 sqmm cable & one run of 4.0 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
M&L for sub main wiring with two runs of single core FRLS PVC insulated, unsheathed, mutistranded copper conductor cable of size 2.5 sqmm drawn in and including rigid PVC rigid conduit medium grade of suitable size but not less than 20mm dia with its accessories, concealed type, including one run of single core FRLS PVC insulated, unsheathed, stranded copper conductor cable of size 2.5 sqmm as earth continuity and cutting chases to wall as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed by Engr-in-Charge.Note:- Finished sub main wiring with two runs of 2.5 sqmm cable & one run of 2.5 sqmm cable alongwith PVC conduit including its accessories shall be measured and paid one unit length.
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified & directed by Engr-in-Charge
Supply and fix in replacement MCB DB vertical type 4 way VTPN sheet metal enclosure 415 volts with 100 Amp fully insulated standard copper bus bar for each face & surrounded with neutral bars and two common neutral bar, two earth bar including cable ties for cable manegement suitable for housing MCCB TPN 415 Volts as incommer, IP-43, IK-09 as per IEC 61439-3 with metal doors all enclosed on standard steel sheet flush mouting type double door factory fabricated complete without MCB & MCCB but with enclosue blank plate complete all as specified & directed by Engr-in-Charge
Supply,fixing, in replacement connecting & testing factory made epoxy powdercoated, distribution board (sheet metal encloser), single pole and neutral, 8 ways, 240 volts horizontal DBs), with metal door and fixed flush wall and suitable for universal mounting with having copper bus bar of capacity 200 Amp rating, of suitable size, for double door and suitable for using MCB, SPN as incommer and SPMCBs as out going confirming to IS 13032 complete all as specified and directed. (Note :- MCBs shall be measured and paid separately under appropriate item of Sch 'A'. complete all as specified & directed by Engr-in-Charge
Supply and fix MCCB 4 pole 125 Amp, Icu 16 Kilo Amp and Ics 100% of Icu with adjustable overload setting 70% to 100% and thermal magnetic release suitable for fixing in VTPN DB complete all as specified & directed by Engr-in-Charge
Supply & fix Isolator TPN, 4 Pole, 415 Volts, 50 Hz AC Supply , 63 Amps, breaking capacity 10KA, IP-20 as per IEC 60947-3 ISI marked complete with connection testing and commissioning complete all as specified & directed by Engr-in-Charge
Supply and fixing MCB SPN 240V, 50 Hz, breaking capacity 10KA 'C' curve miniature circuit breaker (MCB) and current carrying capacity 32 Amp rating in the MCB DB complete with connection testing and commissioning complete all as specified & directed.
Supply & fix MCB SP, 40 Amps, 'C' Curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed.
Supply & fix MCB SP, 2 to 4 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed. (for light circuit)
Supply & fix MCB SP, 6 to 32 Amps, 'C' curve, 240 volts, 50Hz, 10kA IP-20 as per IS/IEC 60898-1 2002 ISI marked complete all as specified & directed by Engr-in-Charge
S&F in replacement rugged LED midbay/highway LED light fittings of capacity 100 Watts, 13000 lm with black colour, powder coated aluminum heta sink for efficent heat dissipation and high purity anodized refelector with electro chemically anodised matt finish inside, the effective glass optics for maximum illumination radious of aluminium reflector not less than 240 mm dia of outer peripherals. Driver and accessories prewired power consumption less then 100 W, with luminaire lumen 13000lm, colour temprature not less than 6600k, ingress protection IP-65 teh high lumen output minimum 130lm/Watts including 3 core flexible copper conductor cord of size 0.75 Sqmm from ceiling rose to light connector complete all as specfied and directed.by Engr-in-Charge
Supply & fix in replacement rugged LED midbay/highway LED light fittings of capacity 80 Watts, powder coated aluminum heat sink for efficent heat dissipation and high purity anodized refelector with electro chemically anodised matt finish inside, the effective glass optics for maximum illumination radious of aluminium reflector not less than 240 mm dia of outer peripherals. Driver and accessories prewired power consumption not less then 80 W, with luminaire lumen >8000 lm, colour temprature not less than 6600k, ingress protection IP-65 teh high lumen output minimum 130lm/Watts including 3 core flexible copper conductor cord of size 0.75 Sqmm from ceiling rose to light connector complete all as specfied and directed. Note for item No. 48 & 49 :- The work ref to be carried out in hangers at the height 12 to 15 Mtrs. therefor units rate quoteds by the contractor should be including of required necessary TNP.
S&F in replacement LED security with aluminum pressure die cast housing, high purity PC fresneldiffuser with silicon gaskets for IP-65 protection, power consumption < 30 W and system efficiency > 100lm /W, in built electronic driver prewired upto terminal block with driver efficiency > 85% power factor > 0.95, suitable for external pole upto 35mm LED Make :- Nichia/Cree/Osram, CRI > 70, ambient temprature range 0-450c, THD<10%, colour tempreature 5700K, surge protectionin cm 3.5KV 50000burning hour as per L70 criteria, multistage constant current constant voltage operated driver with range 150 -270 V AC and safety extra low volatge safe level < 60V DC as per IEC standard including GI pipe medium grade ISI mark of size 32 mm dia length not less than 1.5 mtrs bending to shape for fixing light and nuts, bolts, clamp as required to fix to wall including 3 core flexible copper conductor cord of size 0.75 Sqmm from ceiling rose to light connector complete all as specfied and directed. by Engr-in-Charge
S&F in replacement 2 ft x 2 ft recess mounted full panel LED luminaire with white powder coted housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired upto terminal block, power consumption< 35 W, luminaire lumen > 3500lm and system efficiency > 120lm/w, CRI> 80, LED Make :- Nichia/Cree/Osram/Lumined with LED binning as per ANSI Bin C78.377A, Photo biological safety report as per IEC624718 & electrical insulation class 1 , colour temp- 5700k, Ingress protection IP20, Driver efficiency > 85% , 50000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor > 0.95 THD <10%, surge protectionin CM-3KV, two stage isolated constant current operated driver with range 150-270V AC and safety extraa low voltage safe level < 60V DC as per IEC standard, with LM79 & LM80 certification including 3 coreflexible copper conductor cord of size 0.75 Sqmm from ceiling rose to light connector complete all as specfied and directed. by Engr-in-Charge
S&F in replacement 2 ft x 1 ft recess mounted full panel LED luminaire with white powder coted housing acting as heat sink and frame in CRCA sheet, high efficiency LED grade diffuser, in built electronic driver duly wired upto terminal block, power consumption< 28 W, luminaire lumen > 3000lm and system efficiency > 120lm/w, CRI> 80, LED Make :- Nichia/Cree/Osram/Lumined with LED binning as per ANSI Bin C78.377A, Photo biological safety report as per IEC624718 & electrical insulation class 1 , colour temp- 5700k, Ingress protection IP20, Driver efficiency > 85% , 50000 burning hours (min) as per L70 criteria, ambient temp 0 to 500C, power factor > 0.95 THD <10%, surge protectionin CM-3KV, two stage isolated constant current operated driver with range 150-270V AC and safety extraa low voltage safe level < 60V DC as per IEC standard, with LM79 & LM80 certification including 3 coreflexible copper conductor cord of size 0.75 Sqmm from ceiling rose to light connector complete all as specfied and directed.
Supply & fix, surface square mounting type 12 watt LED luminaire with reflector cover electronic driver, connector block etc with internally prewired fixed to ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire from ceiling rose to fittings complete all as specified & directed.
Supply & fix in replacement, LED garden light (Bollard) with aluminium pipe housing withg glare free mushroom shaped PMMA diffiuser 15 W LED luminaire light fitting, IP 65 protection, H=600mm (Available with H=800mm & 1000 mm) with fixing accessories and connecting up with & including twin twisted 3 core flexible copper conductor cord of size 0.75 Sqmm connecting from Main DBs or nearest light point complete all as specfied and directed. by Engr-in-Charge.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required of size 25x4 mm galvanised iron or steel strip complete all as specfied and directed. by Engr-in-Charge.
S&F in replacement of Air termination, single pointed rod 25mm dia and 1800mm long of GI on Hanger roof at height upto 11 mtr with necessary arrengment for fixing on roof with insulating material of minimum 6 mm thick PVC insulation between roof structure amd air termination point including necssary screws, nuts, bolts & washer of GI with suitable size base plate to fixed in a manner to insure non conductivity with bldg structure complete all as directed and specified by Engr-in-Charge. Note:- Rate for required T&P, Ladders/ Lifter & necessary safety equipment deemand to be included to the qoated rate.
S&F in replacement of GI strip 32x6 mm with saddles/insulators and fixing screws not less than 50 mm long with PVC plug & gutties etc. for roof conductors and down conductors above ground on Hanger at height upto 11 mtr all as directed and specified by Engr-in-Charge
S&F in replacement Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm, drilled screwed including 3 Nos, 8mm dia, 25mm long hex head screw all as directed and specified by Engr-in-Charge
S&F in replacement aluminum strip 25 x 3 mm with saddle of porcelain insulator and fixing screws not less than 50 mm long with PVC plug & gutties etc. on roof/wall and connecting from earth pit the lightning rods point on Hanger at height upto 11 mtr etc all as specified and directed by Engr-in-Charge
Refixing of hanging Aluminium/GI strip on same location with saddles/insulators, screws not less than 50 mm long with PVC plug & gutties etc. for roof conductors and down conductors on Hanger at height upto 11 mtr all as specified and directed by Engr-in-Charge
Supply and fixing GI Pipe 40mm Light grade , for Earth strip protection laid in trench under road or path or fixed on pole or wall with clamps with all fittings complete all as specified and as directed by Engr-in-Charge
M & L earthing complete with galvanized steel earth plate electrode 600 x 600 x 6 mm size, buried directly in ground (earth pit not less than 2.25 M deep below normal ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to and including galvanised iron strip 25×4mm as earthing lead, including 40 mm bore GI light grade protection pipe upto 1 Mtr above the floor level of the buildings where main switch, DB etc, situated, earth lead wire connected to the earth plate by means of GI bolts, nuts, washers and earth plate surrounded by 150 mm thick alternate layers of charcoal or cock dust mixed with common salt 20 mm bore medium grade GI watering pipe PCC pit in PCC 1:3:6 type C-1 (using 20 mm graded stone aggregate) cover of precast RCC 1:2:4 type B-1(using 20 mm graded stone aggregate) duly reinforced with 8 mm formed or twisted bars @ 100 mm c/c both ways, GI wire mesh, GI sheet funnel necessary excavation in soft/ Looose soil and deposited the surplus soil to a distance not exceeding 50 mtr away from starting point, all as per electrical plate no:3 of SSR part-1 .
M&L for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing on around lighting protection GI/ aluminium strips to restrict monkey claiming/ demaging pitch not exceeding 3 inch complete all as specified and directed by Engr-in-Charge. Note:- 1. The above maint work is required to be carried out in hangers at the height 12 to 15 Mtrs. 2. The cost of required necessary TNP & Safty features to be included in the quoted units rates by the contractor.
Allied Builders
M/S OM Enterprises
M/S SHRINATH CONTRACTION
M/S NAVIN & ASSOCIATES
JWALA ELECTRIC CONTRACTORS
M/s Kok Singh Sisodia
jmd engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .