Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.4 CrAccepted-AOC D C COLONY DIPHU KARBI ANGLONG ASSAM | DIPHU | KARBI ANGLONG | ASSAM | ₹2.4 Cr | L1 | Accepted-AOC Awarded Contract Bidder |
| 2 | L2₹3.0 Cr+₹59.2 L (24.7%)Rejected-Finance | ₹3.0 Cr+₹59.2 L (24.7%) | L2 | Rejected-Finance Rejected as L2 Bidder |
| 3 | Rejected-Technical | - | - | Rejected-Technical As per the decision of Bid Evaluation Committee. |
Tender Value
₹3 Cr
EMD Value
₹6 L
Closing Date
6 Sept 2021, 2:00 pmClosed
Chief Engineer,PWRD (EAP),Assam
O/o The Chief Engineer,PWRD (EAP),Assam
Renovation and Upgradation of Warehousing Facilities under the scheme of APART in existing Warehouse Complex at Langhin in Karbi Anglong District
2021_PWD_22121_5
CE/APART/44/2021/7
Open Tender
Civil Works - Building
Lump-sum
360 days
Karbi Anglong District
Please refer Tender documents.
7 documents required · 7 mandatory
₹5,000
State Project Director,ARIAS SOCIETY
₹6 L
O/o The Chief Engineer,PWRD (EAP),Assam
27 Dec 2021
6 Jul 2021
6 Sept 2021
6 Jul 2021
6 Sept 2021
6 Jul 2021
6 Jul 2021 - 19 Jul 2021
19 Jul 2021
Amount
CIVIL WORKS Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. Up to a depth of 2.00m below the existing ground level. In ordinary soil
Providing soling in foundation and under floor with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. (a).Brick on flat soling.
Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With earth or silt or sand obtained by head load with lead upto 90m and lift upto 2m.
Earth/sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading.
Pre construction anti - termite treatment by applying in the junction of walls, column with the floor before laying floor and after operation of item no. 26.1.3 above making a channel 30mmx30mm all over the walls and making rod holes @ 150mm apart up to ground level below and applying emulsion @ 11 litres per square meter of vertical plinth wall surface inside the building so as to soak the soil with the emulsion up to the ground level and refill the holes and channel with the original materials obtained in making channels (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In prop 1cement: 3sand :6coarse aggregate by volume
Plain Cement Concrete floor base in proportion 1:3:6 laid in alteranate bays as specified in co segregrate of size 13 mm to 32 mm including dewatering if necessary and curing etc complete. 50mm.
Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (I) Using Mixer Machine (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser (b)M20 grade concrete or Prop. 1:1.5:3.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (A) In substructure up to plinth level. Foundation, footing, columns with base tie and plinth beam, pile cap, base slab, retaining walls, walls of septic tank, inspection pit and the like and other works not less than 100mm thick up to plinth level. M25 grade concrete.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (B) In super structure above plinth level upto first floor. Walls (thickness not less than 100mm) including attached pillasters, buttresses, plinth and string course etc. N) Without using admixture, plasticiser M20 grade concrete or Prop. 1:1.5:3.
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (B) In super structure above plinth level up to 1st floor level. Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser M20 grade concrete or Prop. 1:1.5:3
Providing and laying plain/reinforced cement croncrete works cement, coarse sand & 20mm down graded stone aggregate including dewatering if necessary, and curing complete but excluding cost of form work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (B) In super structure from plinth level up to 1st floor level. ii) Columns, pillars, posts, struts, suspended floor, roof, landing, shelf and support, balcony, lintel, sill band, beam, girder, bressumer, cantilever, staircase (except spiral staircase and landing ) including preparing the top surface and finishing of nosing. N) Without using admixture, plasticiser c) M25 grade concrete
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides of tie beams, grade beams etc. at or below ground level. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut. Square, Rectangular, polygonal in plan or any shape like Tee/L etc. having plane vertical face. Using 25mm thick plank
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. Using 25mm thick plank
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut of square/ rectangular/ polygonal in plan or any shape like Tee/L etc. having plane vertical face
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Sides and Soffits of Beams, beam haunchings, cantilever girders, bressumers, lintels and horizontal ties. (b) For depth exceeding 1.0M.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Vertical surface such as walls (any thickness), parapet walls, partitions and the like including attached pilasters, butresses, plinth and string courses and the like.
Providing form work of 12mm thick Plywood Board so as to give a rough finish including centering, shattering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in situ reinforced concrete and plain concrete work in: Flat Surfaces such as soffits of suspended floors, roofs, landings, cantelever slabs, chajjas, balconies and the like. (a) Floors etc. upto 200mm in thickness.
REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL TMT Corrosion resistant steel (CRS) reiforcement bar
REINFORCEMENT Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level). From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL. Super Ductile (SD) TMT reinforcement bars
Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) b) Other ISI approved TMT reinforcement bar (SAI/BISCON/THERMAX) (For Assam Type Bldg., drain works,,retaining wall&boundary wall etc. .
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (d) In proportion 1:6.
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level. (b) In proportion 1:4.(1 cement:4 sand)
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. (II) In superstructure above plinth level up to 1st floor level. (c) In proportion 1:5.(1 cement:5 sand)
Brick work in cement morter with 1st class brick including racking out joints and curing complete as directed. In Sub-structure upto plinth level including dewatering if necessary. In proportion 1:4.
1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately). 112mm thick brick wall. In cement mortar in proportion 1:4. (1 cement:4 sand)
Cement concrete works in topping 1:1:2 (1cement :1sand :2 graded aggregates on R.C.C floor, tread and rise of steps finished with a floating coat of neat cement using cement slurry for bond @ 2.75 kg.of cement per sq. m. of floor to be laid in panels including curing complete as directed. 20 mm thick
CERAMIC TILES A) ON FLOOR Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). Delux range Somany/ Orient/Nitco/Qutone Make Of size 600mmx600mm and above
Providing Ceramic Tiles of approved quality, size, shape and thickness not less than 8 mm on floors, skirtings, treads and risers of steps over cement mortar bed 15 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with fix-A Tile Choksey/ Sika/ Pedelite/ Rouf/ White cement slurry mixed with approved pigment to match the shade of granite slab, complete at all levels as specified and directed (coloured pigment should be in conformity with colour of slab and as approved and directed by the Department). Executive range Somany/ Orient/Nitco/Asian Make Of size 400x400 mm and above
CERAMIC TILES B) ON WALLS Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). a) Normal range Somany/ Orient/Nitco/Asian Make ii) Of size 200mmx300mm and above
ANTISKID TILES Providing Antiskid Tiles of approved quality size, shape not less than 8mm on floor, skirting over a cement mortar bed 15mm thick of 1:3 (1 cement: 3 coarse sand) approved make fix with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf)/ white cement complete at all level as specified and directed. (B)VITRIFIED i)Normal range (Sizes 300 mm x 300mm and above) Somany made- Durastone (Unpolished heavy duty Vitrified Tiles) a). Premium
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On Rough Side In cement mortar 1:4
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. On Rough Side In cement mortar 1:5
20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles,chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) c) In cement mortar 1:5
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side c) In cement mortar 1:5
15 mm thick Cement plaster in single coat on single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. A) On rough side d) In cement mortar 1:6
15mm thick plastering of the interior surface of concrete water tanks with cement mortar in prop 1:4 admixed with modified Styrene Butadiene Rubber based polymer like Sika Latex of Sika India Ltd./Dr. Sealkit Masterbond Latex (Asian Chemicals)/Rheomix 141 of BASF @ 200gms per bag of cement as specified and directed by the department complete.
Providing two coats of acrylic water based wall putty/ wall filler of Asian Paints/ Berger/ Dulux over concrete/ cement plaster/ brick walls and ceilings both internal and external after removing all the loosely adhering material from the wall/ ceiling surface with the help of emery stone, putty blade or wire brush, moistening the wall with the help of sufficient quantity of clear water as specified and directed by the department.
(a) White washing with lime on wall surfaces (two coats) to give an even shade including throughly brooming the surface to remove all dirt, dust,mortar drops and other foreign matter.
10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor level including arises, internal rounded angles, not exceeding 80mm girth and finished even and smooth including curing complete as directed. In cement mortar 1:5.
Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Acrylic Emulsion Paint approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Wall painting (two coats) with Plastic emulsion paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a).Plastic Emulsion Paint of approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac)
Finishing wall with two coats of acrylic emulsion exterior coatings of approved brand of required shade by thinning by adding water as per the specification of manufacture after throughly brooming the surfaces to remove all dirt and remains of loose powdered materials as specified and directed by the department. (c) Asian paint / Berger paint / ICI ect.
Finishing old/new wall with water proofing weather coat smooth anti-fungal exterior painting of approved make of Dulux (ICI) paint of required shade after cleaning and clearing the surface etc. including scaffolding complete as directed at all levels (two coats)
Providing two coats of Birla White Wall Care Putty (Water Resistant White Cement based putty for concrete/ mortar walls and ceiling both internal and external) after removing all loosely adhering material from the wall surface with the help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (i) Thickness = 1.5 mm thick
Distempering with dry distemper of approved brand and manufacture(two coats)and of required shade on new wall surface to give an even shade, over and including priming coat of white primer after throughly brushing the surface free from mortar dropings and other foreign matter and including preparing surface even and sand papered smooth.
Applying one coat of cement primer of approved brand and manufacture on new wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth.
Applying one self-priming coat acrylic emulsion paint of approved brand, thinning by adding water as per specification of manufacturer over freshly plastered wall surface after throughly brooming the surfaces free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth as specified and directed by the department. Unicem Shakti.
Applying a floating coat of concrete floor hardner Nitoflor Hardtop or Nitoflor Hardtop standard of Fosroc (india) Ltd. over freshly prepared concrete floors followed by sprinkling of Nitoflor Hardtop or Nitoflor Hardtop standard and finishing surface using power trowel as specified and directed by the department (Concrete floor & base courses to be measured and paid separately). (b) Medium duty
Demolishing RCC work including stacking of steel bars and disposal of unserviceable material as directed for all levels
Demolishing brickwork including stacking of serviceable materials and disposal of unserviceable materials as directed for all levels
Dismantling all types of corrugated/ trapezoidal sheet roofing including ridges, hips, valleys and gutters etc. and stacking the materials as directed by the department for all levels
Demolishing CC floors of various thickness including top layer and base course and disposal of debris as directed for all levels.
Dismantling and removing the existing door and window frame (chowkath) both wooden and steel of different sizes without damaging the walls and removing the frame and necessary repairs to the edges of the walls as directed for all levels. (i) Area of door/window up to 3.00 m2
Demolishing the plastering from walls/ R.C.C. and P.C.C. members without causing any damage to the wall/ member upto any height including disposal of debris as directed for all levels.
Providing, fitting and fixing M.S. grill of required pattern for windows/ clerestory windows/ openingwith M.S. flats at required spacing in frame all round, squre or round M.S bars with round headed bolts and nuts or screws. Plain grill Fixed to Brickwork/PCC/RCC
Structural steel work in single sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. c) In M.S. angles, channels, Tees etc.
Steel work riveted and/ or bolted/ riveted in built up sections, frame work including cutting, hoisting, fixing in position and applying a priming coat of red- lead paint up to 4.6m height above plinth including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. a) In beams and joists with connecting plates/ angle cleats
Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (a) TATA make Circular Hollow section- CHS of Grade YST-310 conforming to I.S. Specification : 1161-1998
Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or conmbination of following sections of (i) Square (ii) Rectangular Hollow section of specification SHS/RHS and including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. a) Using TATA make RHS/SHS of Grade 310 conforming to relevant I.S. code 4923 : 1997
Providing, fitting, hoisting and fixing of roof trusses fabricated using any one or conmbination of following sections of (i) Square (ii) Rectangular Hollow section of specification SHS/RHS and including purlins, bottom runners and providing M.S. cleat, M.S. angle base plank, bolts and nuts with red oxide primer including fitting bottom runner and cleat etc. for fixing ceiling joist as per design complete as directed as per specifications. b) Using other ISI marked approved brand tube
Providing wood work in frame (chowkhats) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mmx3mmx250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsun /Sundi)
Providing Iron Plastic Laminated corrugated coloured sheet Roofing at all levels including fitting and fixing galvanised J or L hooks, bolts and nuts of 8 mm diameter with Bitumen washer 35 mm x 35 mm x 3 mm and G.I. Diamond washer 40 mm x 40 mm x 3 mm complete excluding cost of roof truss, purlins etc. (Roof trusses, Purlins etc. to be measured and paid separately). (a) 0.50 mm thick
Providing Colour Coated (Iron Plastic Laminated Sheet) Ridging including supplying and fixing necessary galvanised screws / washer etc. complete as specified and directed. (A) 0.50 mm thick (i) 150 mm lapping
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (ii) 0.45 mm thick
Providing Pre Painted Galvanized Iron Sheet Roofing (PPGI) at all levels including fitting and fixing with self drilling, self tapping screws complete. (Roof trusses, purlins etc. to be measured and paid separately.) TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (v) 0.60 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (ii) 0.45 mm thick
Providing Pre Painted Galvanized Iron Sheet (PPGI) accessories (Ridges / Valley / Gutter /Flashing) at all levels including fitting and fixing self drilling, self tapping screws complete complete. TATA Blue scope/ Dyna roof / Durakolor /Wonder Roof or equivalent as directed by the Departement (v) 0.60 mm thick
Providing and fixing anodised aluminium framed single leaf door of approved brand with styles size 45mm x 48mm x 3.2mm, top rails 50mm x 45mm x 2.5mm, lock rails 48 mm x 45mm x 2.5mm, bottom rails 100mm x 45mm x 2.5mm fitted with tapper clips of size 20mmx15mmx1.2mm complete with automatic hydraulic floor mounted door closure, butterfly type handles, special cylindrical locks, concealed type tower bolt,neoprene dryset rubber gusket, etc.complete as directed by the Department at all levels. (i)5mm thick frosted glass and 12mm thick prelaminated board
Providing,fitting and fixing anodised aluminuim framed glazed doors with anodised aluminium frame made of 63mm x 38mm x 2.5mm section of approved brand with door style of size 50mm x 45mm x 2.0mm, top rails 50mm x 45mm x 2.5mm, middle rail 100mm x 45mm x 2mm and bottom rails 100mm x 45mm x 2.5mm fitted with glazing clip, special type rubber gasket complete including hydraulic floor spring, pivot, tower bolt in each leaf, aluminium door handle, lock, angles, cleat etc complete as specified and directed by the department at all levels. (ii) 5mm frosted glass
Providing plinth protection with bricks flat laid in cement mortar 1: 4 and finished with 15mm thick cement plaster in prop. 1:2 with a floating coat of neat cement finish.
Providing drain with cement concrete (1:3:6)10cm thick sides 10cm thick bed over brickflat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing and fixing rolling shutters of approved make made of 80mm wide M.S. laths interlocked together through their entire length and jointed together at the ends by end-locks mounted on specially designed pipe shaft with bracket plates, guide channels and arrangements for inside and outside locking with push-pull operation complete including cost of wire, spring and hood cover for the shutters.
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections having thickness at least 1.9 mm of approved brand(HINDALCO/JINDAL/BHAGWATI/SAI)with proof of purchase of ingot of primary producer)/ other equivalent without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (a)2 Track sliding window (iv) 5 mm clear glass
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections having thickness atleast 1.9mm of approved brand (HINDALCO/JINDAL/BHAGWATI SAI (with proof of purchase of ignot from priamry producer)/Other equivalentwithout horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. 2 Track sliding window. 5mm frosted glass
Providing, fitting and fixing anodised aluminium sliding windows and ventilators of standard sections of approved brand without horizontal glazing bars, joints mitred and welded (manufactured to relevant IS specifications) and providing and fixing handles, angle cleat, rubber gasket, roller, bolting device, locking arrangements, screws etc as required complete as specified and directed for all levels. (b)3 Track sliding window (iv) 5 mm clear glass
Surface Dressing of ground including removing vegitation and/or undulation of ground not exceeding 150mm deep and disposal of rubbish outside the periphery and lift upto 1800mm in all kinds of soil.
Supplying, fitting and fixing double leaf heavy duty iron gate, frame made from 50mm x 6mm M.S. flat iron with another horizontal flat at the middle, 20mm dia M.S bars at 200mm apart from bottom flat to top flat and 20 mm dia M.S. bars at 200mm apart from bottom flat to middle flat including drilling, welding etc. complete. All vertical bars are to be protruded at least 100mm above the middle and top flat is to be flattended and pointed as directed. Necessary locking arrangement on both faces, arrangement for temporary closing the gate and 2 nos.( minium) strong iron hinges of M.S bars and flat of same sizes on each leaf to be embeded in C.C brick pillars as necessary including a red oxide painting to all iron works as directed and specified. (Separate payment will be made for posts).
Structural steel work in sigle sections including cutting, hoisting, fixing in position and applying a priming coat of red lead paint (up to 4.6m height) from plinth level including drilling holes, supplying, fitting and fixing with bolts and nuts or welding, if necessary as directed. a) In beams and joists fitted independently without connecting plates.
Providing drain with cement concrete (1:3:6) 10cm thick sides 10cm thick bed over brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shttering for sides and earth work in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. ii). 300mm wide and average 250mm deep with bed slope 1 in 150 with initial depth of 100mm.
Providing precast R.C.C slab over drain ,septic tank etc. in prop. 1:2:4 reinforced with 10mm M.S. bar @ 150mm centre both ways tying with 20 gauge black annealed wire with necessary shuttering , curing etc. complete including fixing in position as directed. b) 75mm thick slab
Extra for scraping, cleaning and straightening reinforcement from RCC or RB work at all levels
Dismantling wood work in frames, trusses, purlins and rafters including stacking the materials as directed by the department for all levels.
Dismantling steel work in single sections (R.S.Joists, channels, angles, tees and flats etc.) including dismembering and stacking the materials as directed by the Department for all levels.
Dismantling steel work in built up sections in joists, angles, channels, tees, flats etc. including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking the materials as directed by the Department for all levels
Chipping and breaking / cutting of loose concrete , mortars etc. Using Electrical chipping hammers to the satisfaction of the Engineer - in - charge for successful execution of the subsequent rehabilition works at all heights with all leads , lifts etc. complete with all tools and machineries required for the job , operator , applicator , labour , scaffolding for staging and supervision etc.
Providing and applying two coats of Nitozinc Primer a two component epoxy zinc rich Primer / Sika Top Armatec - 108 or equivalent product on the properly cleaned and prepared steel bars after the required chipping and cleaning of the concrete surface as per the manufacturer's specifications.
Before laying of the Micro Conctrete , the substrate shall be coated with a bonding agent , Nitobond EP Std. / Sikadur - 32 LP or equivalent product and the micro concrete shall be poured within 6hrs / 4hrs or as applicable of the application of the Bonding agent.
Providing and placing free flow micro concrete Renderoc RG /Sika Micro - Concrete -2 or equivalent product of after fixing slurry tight shuttering.The micro concrete should be mixed mechanically while maintaining water , powder ratio of 0.16 strictly in accordance with the manufacturer's instructions and as per the direction of the Engineer - in - charge. The micro concrete should develop a compressive strength of 10N/mm2 within 1day , 40N/mm2 within 7 days and 50N/mm2 within 28 days. The cost is inclusive of materials , transportation , labour , taxes etc .all complete.
Drilling 12mm dia X 100mm hole into the concrete surface using concrete hammer drill machine. Providing 10mm PGMS nozzles in a grid of 0.25m both and injecting with high strength cementitous grout - Cebex 100/Sika Intraplast EP or equivalent product till completion and refusal of grout complete as per manufacturer's specification. The nozzles are to be sealed off after grouting using Renderoc Plug/Sika - 2 mortar or equivalent product injecting with high. strength cementitious grout - Cebex 100/ Sika Intraplast EP or equivalent product of Fosroc complete as per the specifications of the manufacturer.
Providing and applying two component epoxy resin based moisture intensive low viscous Sikadur - 53 UF for high pressure injection grout with drilling & fixing of nozzle at 0.30 mt centre to centre as per manufacture specification. The cost is inclusive of material , labour, tools & tackles etc all completes.
Cracks openings should be chiselled out to approximately 20mm X 20mm , and should always be undercut to avoid formation of a 'V' shape and cut back to a minium depth of 15 mm and given a good mechanical key to apply Renderoc Plug /Sikadur - 31 or equivalent product based per manufacture's specification.
Providing and applying Nitobond SBR Latex/Ska Latex or equivalent priming coat followed by placement of Renderoc S2/ Sika Top - 122 or equivalent high build Light weight polymer modified mortar to give a composite thickness of 10mm. The Mortar should be mixed mechanically white maintaining water powder ratio strictly in accordance with the manufacture's instructions as per the direction of the Engineer - in - charge. The cost is inclusive of materials and application and exclusive of scaffolding.
Taking out from position and repairing steel window shutters including steel frames at all levels after cutting out the heavily rusted and damaged portion of the shutters and frames and welded with the new 'Z' section of steel members, corner, hinges, stay etc. including fitting and fixing in position and riveting with new rivets adjusting, cleaning, cutting the holes and making good the damages to metal with existing one. Window grills to be removed during carrying out the work and to be re-fixed in position after completion of work. The glass panes damaged during execution should also be changed.
Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in Formwork Flat surfaces such as soffits of suspended floors , roofs landing ,cantilaever slabs chajjas , balconies and like ii) 25mm thk. plank
Providing polished ceramic wall tiles of approved quality, size, shape and thickness not less than 8mm on walls and skirtings over cement mortar bed 10 mm thick in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey / Sika / Pedelite / Rouf) /white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. (Cement plastering to be measured and paid separately). (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department). (Walls means both interior and exterior walls). a) Normal range Somany/ Orient/Nitco/Asian Make i) Of size 200mmx200mm and above
15mm thick cement plaster in single coat on rough side of single or half brick wall for interior plastering up to 1st floor level including arises, internal rounded angles not exceeding 80mm girth and finished even and smooth including curing complete as directed. (d) In cement mortar 1:5
20mm thick cement plaster in two coats,backing coat 15mm and finishing Coat 5mm thick on rough side of single Or half brick walls for interior plastering Up to 1st floor level including arises, internal rounded angles, chamfers and/or rounded angles not exceeding 80mm in girth and finished Even and smooth including curing complete as directed. (d) In cement mortar 1:5
Providing 0.63 mm thick(24 gauge) galvd plain sheet in valley , lining, flashing etc. and fitted with gavd. Iron J or L hook bolts and nuts, G.I. limpet and bitumen washer complete, bent to shape and fixed in a positions as directed.
Providing bracket made out of M.S. flat, bent to proper size and shape as per drawing and fitting with necessary bolts, nuts, sand washers etc. for fixing A.C / G.I. sheet gutters with purlins.
Synthetic enamel paint, aluminium paint / bituminus paint on steel and other metal surfeces. (i).Removing old paint from steel and other metal surface and making the surface even. (a). With hand scraping
Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint of approved brand and manufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surface of all dirt, dust and other foreign matter. (ii).Surfaces up to 100mm in width or girth. (a). General purpose (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac).
Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measured and paid separately ) (B) With 1st class local wood (Gamari/Hollock/Bonsum ) (ii) 35 mm thick.
Providing, fitting & fixing plain MS grill of required pattern for windows/ ventilators/fixed glazing & other openings with MS sq bars & flats as per details provided including welding to the frames & finishing with one coat of red oxide primer and two coats of enamel paint. (a) Fixed to wooden Frames. (b) Plain grill.
Pre construction anti - termite treatment by applying in the entire levelled area after plinth filling and before laying floor by applying the emulsion @ 5 (five) litres per square meter of the surface to be spread with light rodding so as to ensure proper absorption by the filled up earth (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. (a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution
Pre construction anti - termite treatment at the bottom of foundation pits and walls on either side up to a height of 300mm from bottom of the excavation made for column plinth beam, wall, trenches etc. by applying the emulsion @ 5 (five) litres per square meter of the surface area before starting construction work (supplying of necessary tools and accessories by the contractor) as per the direction of the Department complete. a) with aqueous emulsion having concentration 1:19 with chloropirophose solution (tricel or euivalent) and water, i.e. 1% solution.
Providing and fixing flush door shutters solid core construction with frame of 1st class hard wood with cross band and face veneered ply wood face panels conforming to relevent I.S code including oxidised iron butt hinges (100mm x 75mm x 3.5mm) 6 nos with necessary wood screws. b) Non decorative type and block board core. (iii) 30 mm thick .
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed. (a) M. S. Angles…….
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed. (b) M. S. Flats
Supplying fitting and fixing M.S.angles, M.S. flat, M.S. bolts and nuts including painting with red lead paint one coat complete as directed. (c) M. S. Bolts & Nuts
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) (a) Sliding door bol (i) 300mm x 16mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) (b) Tower bolts (i) 300mm x 12mm
Supplying, fitting, fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.( anodised to bright natural matt & satin finished ) (c) Door handles (iii) 300mm
ELECTRICAL WORKS Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Short point up to 3.00 metre. length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Medium point up to 6.00 metre. Length.
Wiring for light/fan/call bell point with 3x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick / heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) ceiling rose etc. complete Long point up to 10.00 metre. Length.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq.mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537. Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including earth continuity in surface/ recessed 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit wiring system. With 2 x 10 sq. mm. + earth continuity with 1x 6 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS: 9537 Part - III conduit.
Wiring for 5 pin 6 amp plug with 1.5 sq mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) and 6 amp flush type switch (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.)make) earthing the 3rd pin of the socket as required on the switch board in surface/ recessed P.V.C. conduit wiring system. When fitted on same board of light and fan.
Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system including earth continuity with 2.5 sq. mm cable to the 3rd pin of the socket as required complete with 20 mm. dia. 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) Long point up to 10.00 metre. Length.
Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed 2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) wiring system including earth continuity with 1.5 sq. mm. cable to third pin of the plug socket etc. as required complete. Medium point up to 6.00 metre. Length.
Supplying including installation of socket outlet 6/16 Amps 3/5 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying including installation of socket outlet 6 Amps 3 pin combine shuttered complete , MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 16 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting fixing of 6 amp one way modular clip in switch, MODEL RANGE LEGRAND (MYLINC), ANCHOR (ROMA), MK (IVORY), ABB (CLASSIC), KOLORS (KRAZE), SCHNEIDER (OPAL), PHILIPS, Havells including making necessary connection as per direction of department.
Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door (IP-43) surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager, Crabtree xpro make) 12 way SPN double door
Supplying with fitting and fixing MCCB incomer and MCB outgoing sheet steel, phosphatised, powder painted double door IP-43 surface mounting vertical TPN MCB DB incorporated with bas-bar up to 250A, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider MG, legrand, Hager make, Crabtree Xpro make) 4 way TPN (4+12) double door
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager, Crabtree Xpro make) 6 to 32A
Supplying with fitting and fixing single Pole 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing 30/100/300mA sensitivity 240/415V 50Hz DP RCCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 100/300mA sensitivity DP RCCB (ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. C Series(ABB, Schneider MG, legrand, Hager, Crabtree Xpro make) 40A
Supplying with fitting and fixing panel mounting open execution 35/36KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 35/36 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Hager make) 250A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 40A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 63A
Supplying with fitting and fixing panel mounting open execution 25KA 415V 50Hz 4P MCCB (Ics=Icu, adjustable Ir setting 0.7) (without enclosure) of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 25 KA 415V 50 Hz 4P MCCB (Schneider, legrand, Siemens, Indo Asian, Hager make) 100 A
Supplying with fitting and fixing Four Pole 415V Front handle operated On Load Change over switch (IP-20 protection powder painted sheet steel enclosure fitted on angle iron frame of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. (ABB, Schneider, legrand, L&T make) 200A
Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipe with necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement 300 mmx300 mmx6 mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 K and Charcoal 64 K in pipe Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt.
Supply, installation & testing of Copper Plate earth station with 600 mmx600 mmx3 mm copper earth plate with necessary 40 mm dia. G.I. medium duty watering pipe with G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mmx40 mm G.I. reducing socket for funnel including locking arrangement with 300 mmx300 mmx6 mm C.I. hinged cover plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt .
Extra for using salt 5 K and Charcoal 96 K in G.I./Copper plate Earth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the deptt .
Supplying & laying of 6 SWG G.I. earth from Earth Electrode (below G.L.) to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25x5 mm size G.I. strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of G.I. nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supplying & laying of 25x4 mm size Copper strips drawn on surface from earth electrode to Electrical switch gears, machineries etc complete with supply of Brass nuts & bolts, screws etc including riveting, soldering & making necessary connection as approved, specified and directed by the deptt.
Supply, fitting & fixing of Lighting Finial Arrestor made of 25 mm dia 300 mm long solid G.I. tube having 85 mm dia. single prong at top and 3 mm base plate at bottom complete with fitting & fixing with G.I. nuts & bolts on roof, RCC slab, top of column etc. as specified and directed by the deptt.
Supply, fitting & fixing 20 mmx5 mm G.I. strips drawn on vertically or horizontally on building wall/parapet wall in surface system complete with supply of G.I. Nuts & Bolts, Screws etc including riveting, soldering and making connection as approved by the Deptt.)with earth electrode G.I. strips and Lightning Arrestor etc. as specified and directed by the deptt.
Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.)as required complete and as directed by the Department. Domestic Heavy Duty 450 mm sweep 900 RPM Single phase (ORIENT make)
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 3 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 4-5 module type Metal
Supplying including and fixing of following Metal boxes for MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE), CRABTREE in surface/ recessed system complete as per direction of department. 6-8 module type Metal
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE),CRABTREE as per direction of department. 3 module
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE),CRABTREE as per direction of department. 4 module
Supplying including fitting fixing of following front plate of suitable colour MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS), ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE),CRABTREE as per direction of department. 6 module
Supplying with fitting fixing of blank plate single in modular switch system MODEL RANGE LEGRAND (MYRIUS), ANCHOR (VIOLA), MK (WRAPAROUND/ PLUS),ABB (CHEIRON), KOLORS (KREST), SCHNEIDER (VIVACE),CRABTREE complete as per direction of department.
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 Core A2XWY A2XFY 4.00 Sq.mm 3 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 Core A2XWY A2XFY 6.00 Sq.mm 3 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 Core A2XWY A2XFY 10.00 Sq.mm 3 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 & 1/2 Core A2XFY 25.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 & 1/2 Core A2XFY 70.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size PVC/XLPE insulated and PVC sheathed 1.1 KV G Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988 armoured U.G. cable U.G. cable laid in ground/partially in air (as required for termination over ground including excavation of cable trench up to depth of 75cm, refilling, protective brick covering, Sand cushioning etc complete handling of surplus spoil, debris et to proper place as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) . 3 & 1/2 Core A2XFY 120.00 Sq. mm.3 & 1/2 Core armoured U.G. cable
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 A2XWY A2XFY 4.00 Sq.mm 3 Core U.G. cable in 25mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 A2XWY A2XFY 6.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 A2XWY A2XFY 10.00 Sq.mm 3 Core U.G. cable in 32mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 & 1/2 A2XWY A2XFY 25.00 Sq.mm 3&1/2 Core U.G. cable in 40mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 & 1/2 A2XWY A2XFY 70.00 Sq.mm 3&1/2 Core U.G. cable in 50mm dia medium duty G.I. pipe
Supply and laying of following size Solid Aluminium conductor up to 10 sq mm balance stranded conductor, XLPE Insulated, cores laid up, PVC tape inner sheathed, Armour (Aluminium for single core up to 70 sq mm balance Aluminium strip, Galvanised for cables up to 2x10 sq mm.3x10 sq mm,4x6 sq mm balance all galvanised steel strip) , extruded PVC Type ST2 sheathed, 650/1100V grade as per IS 7908(Part 1) 1988, LT armoured U.G. cable laid in pucca flooring, road crossing, drain crossing as per site requirement and partially in air to connection as approved by the Depts. the control switch, through medium duty G.I. pipe (Tata/ Nezone make or equivalent as approved by the Deptt) bend and socket including excavation and refilling the trench and making good damage done as specified and directed by the deptt. (Nicco/ Havells/ RPG/CCI/Polycab/Gloster/ Finolex make or euivalent) Core - 3 & 1/2 A2XWY A2XFY 120.00 Sq.mm 3&1/2 Core U.G. cable in 65 mm dia medium duty hot dip galvanised pipe (AKG or equivalent as approved by the Deptt.)
Supply including fitting and fixing of 1.1 KV PVC/XLPE cable INDOOR/OUTDOOR end termination Kits (Raychem RPG make) HEAT SHRINK TYPE including all accessories for the following sizes including testing and commissioning as specified and directed by the Deptt. 70-150 Sq.mm., 3/ 3.5/ 4 Core cable.
Supplying including installation of cast iron cable marker as specified and directed by the deptt.
Supplying and fitting fixing of H.T. danger plate complete as required and as directed by the department.
Supplying including installation of the Octagonal poles shall be designed to withstand the maximum wind speed of 169 km/hr. The top loading i.e. area and weight of fixtures are to be considered to calculate maximum deflection of the poles and the same shall meet the requirement of BS:5649 Part VI 1982. The pole shaft shall have octagonal cross section and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding of the pole shaft. The welding of the pole shaft shall be done by Submerged Welding process. All octagonal pole shafts shall be provided with the rigid flange plate of suitable thickness with provision for fixing 4 foundation bolts. The base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside. The welding shall be done as per process approved by Third Party Inspection agency. (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Pole Type BOP or equivalent-9030 Height 9m The materials of the pole as follows : Conforming to grade S355JO Conforming to grade S355JO, Base Plate :- Fe 410 Conforming to IS 226/ IS 2062, Foundation Bolts:- 6.8 Gr. As per IS 1367, Pole Sections:- The Octagonal Poles shall be in single piece with single longitudinal welding join, Galvanization :- The poles shall be hot dip galvanized as per IS 2629 / IS 2633 / IS 4759 standards with average coating thickness of 65 micron. The galvanizing shall be done in single dipping. Door opening:- The Octagonal poles shall have door of approximate 500 mm length at the elevation of 500 mm from the base plate. The door shall be vandal resistance and shall be weather proof to ensure safety of inside connection as approved by the Depts.. The door shall be flush with the exterior surface and shall have suitable locking arrangement. The pole shall be adequately strengthened at the location of the door compensate for the loss in section. There shall also be suitable arrangement for the purpose of earthing, Smart pack Junction box with 6 MCB & Terminals for mounting inside base compartment of Pole. Top Dia. :- (A/ 70, Bottom Dia.:- (A/ 155 , Sheet Thickness :- 3mm , Base Plate Dimensions :- (L x B x 260 x 260 x 16, Foundation Bolt Size :- (no. x dia.) 4 x 24 Dia, Pitch Circle Dia.:- (PC 250 Bolt Length:- 750, Projected Bolt Length :-125 Anchor plate thickness :- 4 mm , Pole Foundation :- The octagonal poles shall be bolted on a pre- cast foundation with a set of four foundation bolts for greater rigidity. Foundation:- The foundation shall be done with ( Earth work 2.04 cubic Meters.RCC 1:1.5 : 3 proportion 0.65 cubic metres. Steel 22.43 Kg. Shuttering 4.32 square metres. = 22.43 Kg.
Supplying including installation, connection as approved by the Deptt., testing and commissioning of CENTRIFUGAL MONOBLOCK PUMP SET complete as directed and specified by the deptt. 3 HP single Phase Centrifugal monoblock pump set (Crompton Greaves/ Aquatic/ CRI/ V-Guard/Calma make) 2900 rpm with DOL Starter ( Crompton Greaves/ Control & Switch Gear/ BCH/ L& T / Siemens make) .
Supplying including installation, connection as approved by the Deptt., testing and commissioning of SUBMERSIBLE PUMP SET 3 (Three Phase) with steel cable rope and submersible cable complete as directed and specified by the deptt. Three phase Submersible motor pump set (Texmo / Crompton Greaves/ Aquatic/ CRI/ V-Guard/Calma Make) suitable for 100 mm bore well and above. 5 HP STAGE 14 to 50 with MCB controlled Submersible motor pump set control panel.
Supplying and installation and commissioning of vermin and dust proof totally enclosed double door cubical type compartmental floor mounting panel board of size 1.20 m ×1.00 m ×0.50 m made of 16 SWG1.66mm) thick CR sheet and 35 mm × 35 mm × 6 mm size angle and 35 mm ×6 mm flat iron having 4 nos legs at the bottom and G.I. Sheet reefing on the top complete painting with 2 coats of red oxide metal primer and 2 coats of enameled paint. The panel board is to be erected in 1:3:6 RCC pole foundation including excavation of trench and brick soling etc. complete neatly internal wiring done as specified and directed by the department comprising of the following electrical items. 1. 40 Amp 4 pole 415 Volt 50 Hz MCCB as incomer - 1 no 2. 32 Amp 2 pole open execution with HBC fuse SDFU unit as outgoing - 3 nos. 3. 25 mm × 5 mm size 4 strip copper Bus-Bar- 1 set 4. 40 Amp 4 pole ON-OFF poser contactor - 1 No. 5. Surface mounting timer switch - 1 No. 6. 63 Amp bakelite HBC fuse kit-kat - 3 Nos
Supplying including fitting and fixing of Hot Dip galvanised arm bracket for installation of luminaries. Header with top cap 300 mm long pipe of thickness 3 with arrangement to fix on pole top with 3 Nos. of bolts. i Armed of required length size 48.3mm out side dia x 3.25mm thick (BAJAJ/ PHILIPS/ VALMONT/ PARUTHI ENGR/Nezone make) Stiffener plate from arm of the following types : Single arm bracket 1500mm long for 3m to 10 metre. Poles.
SANITARY WORKS Providing fitting and fixing vitreous water closet squatting pan (Indian type W.C Orissa pattern) with all fittings and fixtures complete including cutting and making good to the walls and floors whereever required. (Flushing Cistern to be paid separately) Indian type W.C Orissa pattern of size 580 x 440 mm a) White i) Parryware make
Supplying, fiting and fixing automatic flushing cistern with all internal fittings with CI brackets including fitting and fixing standard size CP flush pipe, union clamps etc. compete as directed and specified (pipes will be measured separately) ii) Hindware make a) White Auto Cister 10 litre (Cat. No.C61002)
Providing vitreous China wash basin with CI/MS brackets, C.P brass chain with plug,PVC waste pipe including painting of fittings and brackets, cutting and making good the walls wherever required. (Pillar cock, stop cocks, waste coupling are to be paid separately) PEDESTAL BASIN (with pedestal) Parryware Make White Cascade NXT 550 x 440 with long Pedestal (Cat. No.C0404/C0380)
Providing fitting and fixing vitreous china flat back type lipped front urinal basin with standard flush pipe and CP brass spreader andbrass unions, etc. complete including painting of fittings and brackets, cutting and making good the walls & floors wherever required. Parryware Make White (iv) Flat Back (Cat. No.C0501/72)
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches. 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches. 75mm dia
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying, fitting and fixing PVC pipes of 6 Kg/cm2 (Supreme/Prince) or other ISI approved including joining ,fitting and fixing wiyh clamps etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 75mm dia
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing 87.5 degree PVC bend with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii)75mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iv) 75 mm dia.
Supplying fiting and fixing 45degree PVC bend of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm dia
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC Plain single tee of (Supreme/ Prince) or other ISI approved including joining, fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75 mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches. 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surface or trenches. 75mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC single tee with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and a) In exposed surfaces or in trenches. (ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iv) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 75 mm dia.
Supplying fiting and fixing PVC single ‘Y’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 75 mm dia.
Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 75 mm dia.
Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm dia.
Supplying fiting and fixing PVC double ‘Y’ plain of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 75 mm dia.
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (i) 110mm x110mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. a) In exposed surfaces or in trenches. (ii) 75 mm x 75mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110mm x110mm
Supplying fiting and fixing PVC cross ‘T’ with door of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (ii) 75 mm x 75mm
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 110mm dia
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. In exposed surfaces or in trenches. 75mm dia
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (i) 110 mm dia
Supplying fiting and fixing PVC coupler of (Supreme / Prince)or other ISI approved including joining , fitting and fixing etc. as necessary complete at all levels including below G.L. as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. (iii) 75 mm dia
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. 110mm dia
Supplying fiting and fixing PVC socket plug of (Supreme/Prince) or other ISI approved including joining , fitting and fixing etc. in exposed surface or trences as necessary complete at all levels including below G.L. as directed and specified. 75mm dia
Providing fitting and fixing PVC cowel of ISI make complete as directed and specified. (iii) 90mm dia. PVC cowel of ISI make
Providing fiting & fixing C.I. Grating to the floors complete as directed and specified. 110mm dia
Supplying fitting and fixing C.P. bib cock 15mm dia of approved brand directed and specified. (G.I. & C.P pipes will be measured separately). Essco make (Delux/Sumthing spl./Tropical) (a) Bib cock short body
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (i)15mm dia
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (ii)20mm dia
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (iii)25mm dia
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (iv)32mm dia
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (v)40mm dia
STOP COCK Supplying fitting and fixing stop-cock of approved brand of size as mentioned below and directed and specified (G.I. & C.P. pipes will be measured and paid separately) I) Brass stop cock (heavy) of Sant make (vi)50mm dia
PUSH BIB COCK Supplying fitting and fixing push bib cock 15mm dia complete as directed and specified as follows. (pipes will be measured and paid separately). a) C.P.C.H. (a) Light type
PILLAR COCK Supplying and fitting fixing C.P. pillar cock of 15mm dia of approved brand as specified and directed. SONA make (a) Light type
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 50mm dia
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 40mm dia
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 25mm dia
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 20mm dia
VALVE Supplying and fitting gun metal country pit valve (full way valve) I.S.I. Make as specified and directed. 15mm dia
Supplying and fitting ball valve as specified and directed. a) 25 mm dia. (gun metal)
Supplying and fitting ball valve as specified and directed. b) 20mm dia. (gun metal/Copper)
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. a) 50 mm dia (Heavy type)
Supplying fitting and fixing gun metal check valve including necessary threads to pipes. b) 40 mm dia (Heavy type)
Supplying fitting and fixing G.I. Foot valve with strainer including cutting necessary threads to pipes. a) 50 mm dia (Heavy type)
Supplying fitting and fixing G.I. Foot valve with strainer including cutting necessary threads to pipes. b) 40 mm dia (Heavy type)
Supplying and placing plastic cylindrical vertical claused top (PCVC) tank of Sintex / Plycon / Pattern make over the stagging with manhole cover with locking and cleaning arrangement including providing pads of size as required for inlet and outlet pipes. (I) 500 litre capacity (a) Sintex make
Supplying fitting and fixing Hand pump for 40 mm dia tube well with all accessories complete as directed. i) Maya popular - 6
Construction of inspection pit inside measurement 450mm x450mm x450mm flush with 100mm diameter HCI/PVC pipes and cement concrete base in proportion 1:3:6 over flat brick soling, 12cm brick wall in cement mortar in proportion 1:4 finished with 13mm cement plaster in proportion 1:2 in side wall and floor. 450mm x450mm air tight C.I. inspection pit cover and frame complete including supplying of materials, necessary excavation of pit as directed.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. In exposed surface or trenches. 75mm dia
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 110mm dia.
Supplying, fitting and fixing 87.5 degree PVC bend of (Supreme/Prince) or other ISI approved including joining ,fitting and fixing etc.as necessary complete at all levels including below G.L as directed and specified. b) Concealed by chiselling or breaking brick wall/C.C./R.C.C and making good to the damages. 75mm dia
Providing fitting and fixing Mirror with plastic frame of size 500x400mm complete as directed and specified.
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (A) Exposed or in trenches SFMC/ FUSION brand or other brand of equivalent quality. a) PN-16 Pipe,16mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (A) Exposed or in trenches SFMC/ FUSION brand or other brand of equivalent quality. b) PN-16 Pipe,20 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (A) Exposed or in trenches SFMC/ FUSION brand or other brand of equivalent quality. c) PN-16 Pipe,25 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (A) Exposed or in trenches SFMC/ FUSION brand or other brand of equivalent quality. d) PN-16 Pipe,32 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (A) Exposed or in trenches SFMC/ FUSION brand or other brand of equivalent quality. e) PN-16 Pipe,40 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (A) Exposed or in trenches SFMC/ FUSION brand or other brand of equivalent quality. f) PN-16 Pipe,50 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (B) Concealed pipe with cutting chases & making good the walls SFMC/ FUSION brand or other brand of equivalent quality. a) PN-16 Pipe,16mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (B) Concealed pipe with cutting chases & making good the walls SFMC/ FUSION brand or other brand of equivalent quality. b) PN-16 Pipe,20 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (B) Concealed pipe with cutting chases & making good the walls SFMC/ FUSION brand or other brand of equivalent quality. c) PN-16 Pipe,25 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (B) Concealed pipe with cutting chases & making good the walls SFMC/ FUSION brand or other brand of equivalent quality. e) PN-16 Pipe,40 mm OD,SDR-7.4
Providing and fixing 3 layer (Outer green / GREY coloured UV Stabilised, middle black coloured UV Stabilised and inermost layer white coloured with antimicrobial property) Fusion welded PP-R ( Poly propylene-random copolymer) Pipes, SDR 7.4 having thermal stability for hot and cold water supply conforming IS 15801-2008 including all plain PP-R fittings and brass threaded PP-R fitting and clamping, cutting and making good to the damages. (B) Concealed pipe with cutting chases & making good the walls SFMC/ FUSION brand or other brand of equivalent quality. f) PN-16 Pipe,50 mm OD,SDR-7.4
Providing, fitting and fixing recessed soap tray / soap dish complete as directed and specified. (a) Parryware Make (ii) Wall Soap tray (Cat. No.C9951)
Providing, fitting and fixing Chrome Plated towel ring complete as directed and specified. (b) Sona make (i) Towel ring round (Cat.No.TR-06051)
Providing, fitting and fixing Chrome Plated waste coupling complete as directed and specified. (b) Sona (i) Rupa 32mm (HT/ FT) (Cat.No.WS-0801)
Providing, fitting and fixing Chrome Plated bottle trap complete as directed and specified. (b) Sona make (i) Bottle trap indian 32mm (Cat. No.BT-0751)
Providing, fitting and fixing Chrome Plated bottle trap pipe complete as directed and specified. (a) Sona make (i) Pipe for bottle trap 300mm long (Cat. No.BT-0761)
Construction of filter bed in soak pit including earth work in excavation of soil and then filling up of the trench with brick bats/Charcoal covered with earth over a layer of A.C. plain sheet above brick bat filling complete as directed. (sizes of soak pit may vary depending on the sizes and capacities of the septic tank as well as the number of users as mentioned in the table.
Flushing, clearing, washing and watering of the tube well
Labour for boring hole for inserting tube well pipes through different soil/rock media including hire charge of drill pipes , scaffolding , tools and plants as necessary and taking out the same and lowering pipes , fittings complete as directed by the Department. (i) Bore hole of 75mm diameter
Supplying , fitting and fixing pipes plain/bevel ended for casing , conforming to relevant IS codes of practice including Supplying and fitting of tube well accessories , lowering of assembly pipes concentrically in the borehole followed by supplying and packing of pea gravel free from dirt , dust and other foreign materials in the annular space between the borehole and assembly pipes complete as directed by the Department. II. PVC PIPE SUPREME / PRINCE /FUSION / SFMC Brand (iii) 75mm diameter
Supplying , fitting and fixing suction pipes plain / bevel ended , conforming to relevant IS codes of practice including supplying and fitting of accessories , lowering of assembly pipes concentrically in the casing pipes complete as directed. II. PVC PIPE SUPREME / PRINCE /FUSION / SFMC Brand (iv) 50mm diameter
Supplying fitting and fixing ISI approved PVC filter 3.00 metre long. (ii) 50mm diameter.
Supplying fitting and fixing check value (non return value) including thread to pipes. (iv) 50mm diameter
Supplying including installation , connection as approved by the Deptt. Testing and commissioning of JET PUMP SET (HORIZONTAL) complete as directed and specified by the deptt. 1HP single phase jet pump set (Horizontal (Cromption Greaves / Aquatic / CRI / V - Guard make) 2900 rpm with DOL starter (Cromption Greaves / Control & Switch Gear / BCH / L & T / Siemens make)
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) R.C.C. top slab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. Cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With F.P.S. bricks with class designation 75
Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (heavy duty) 560 mm internal diameter, total weight of cover and frame to be not less than 208 kg (weight of cover 108 kg and weight of frame 100 kg) : With F.P.S. bricks class designation 75
NON SCHEDULE ITEMS Providing integrated Trimix flooring of mixed M-15 grade (1:2:4)& of specified thickness by Vaccum dewatering in fresh cement concrete works laid by levelling with screed vibrator ,dewatering of excess water in fresh vaccum pump with bottom filter mat & top filter mat duly sealing edges allround finishing with power floater & trowel to attain hard surface with all lead & lift etc.all labour materials 40 HPgenerator for power supply,tools & plants to be borne by the contractor & work as directed by the engineer incharge. : (Only labour Charge)
Repairing brick wall with cement concrete (1:2:4) of thickness varing from 25mm to 100mm after cleaning of the surface of the brick wall applying bonding agent Nitobond EP Std./Sikadur- 32LP or equivalent product to cover up the damaged portion of existing brick wall including fixing of chicken wire netin postion to hold the c.concrete if necessary. Finished and complete as per direction of Engineer in Charge.
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. 8" Gravel filling
Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. Boulder filling
Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In prop. 1 cement : 2 sand : 4 coarse aggregate by volume
PITLESS WEIGHT BRIDGE (SIZE-15MT.X3mt.) with foundation and ramp
Concentra wire
Providing fitting and fixing of ACP sheet over necessary aluminium frame with 8mm thick plywood as per directed.
Barbed Wire
Steelwork in single section for air inlet made of frame of MS Angle 40 x 40 x 6mm joints metred with 4 nos. 15cm long lugs of MS flat 20 x 6mm to act as hold to be fixed in cement concrete blocks of size 230 x 100 x 100mm in cement concrete mix (1:2:4) including & fixing G.I wire fibric to be fixed with 15 x 3 mm MS Flat beading tack welding including applying priming coat of Zinc chromate yellow prime cleats are to be provide on inner side without or support the covering slanted MS flat strip of size 40 x 40 x 6mm to be provided as per the drawing . complete air inlet to be manufactured & fixed in position as per the drawing as per the direction of Engineering Ingharge Note :- Cement concrete block shall be paid separately under relevant item.
Providing and fixing horizontal single/multi stage pumping set with CI body, bronze impeller, stainless steel sheet and connected by a flexible coupling to a totally enclosed fan cooled indication motor mounted on common structural base plate with all pump accessories complete as per specificaions including rubber neoprendined vibration eliminators mounting pad and expansion bellow in suction discharge connection between pump and piping, motor to be suitable for 415V 3 phase 50 Hz AC supply. A.MAIN PUMP FOR HYDRANT & SPRINKLER Type of pump - Centrifugal End Suction/ Vertical on line Capacity - 2280 LPM Head -56 MWC HP - ( Power requirements as per Clause 7.4.1.5 of TAC's Fire Protection Manual)` Motor RPM - 2850
Providing and fixing horizontal single/multi stage pumping set with CI body, bronze impeller, stainless steel sheet and connected by a flexible coupling to a totally enclosed fan cooled indication motor mounted on common structural base plate with all pump accessories complete as per specificaions including rubber neoprendined vibration eliminators mounting pad and expansion bellow in suction discharge connection between pump and piping, motor to be suitable for 415V 3 phase 50 Hz AC supply. B.JOCKEY PUMP FOR HYDRANT & SPRINKLER Type of Pump - Centrifugal End suction/ Vertical on line Capacity - 180 LPM Head -56 MWC HP- 10 H.P. Motor RPM- 2900
Providing and fixing standby single/multistage horizontal centrifugal pump set of CI body bronze impeller, stainless steel shaft. The pump shall be connected by a flexible coupling to a suitable capacity of diesel engine with automatic starting alongwith battery charger, panel, including MS base plate and mountings. The diesel driven pump shall be complete with diesel tank with level indicator, exhaust piping insulated etc. complete as described in technical specifications. Type of Pump - Centrifugal End suction Capacity - 2280 LPM Engine BHP- (As per Clause No. 74.5.2.3 TAC's of Fire Protection Manual ) Head -56 MWC RPM - 1800
Providing and fixing pressure switches for every individual pump to operate at drop of pressure set for.
Providing and fixing double flanged vertical air vessel fabricated from 8mm MS plate with dished ends 450mm dia and 2m high common for fire and jockey pumps complete with Air release valve and GM gate valves in drain and all connecting nozzles etc.
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 120 sq.mm
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 25 sq.mm
Supplying, laying, termination & testing of undernoted sizes of copper conductor FRLS insulated both inner and outer sheath, PVC sheathed and sleeved 1.1 KV grade power distribution cables conforming to relevant IS code and laying through and clamping the wall/racks/cable trays including dressing and clamping the cable with M.S. zinc passivated clamps etc. as required. 3C x 4 sq.mm
Supply and fixing of perforated 2mm thick CRCA sheet steel powder coated cable tray of following sizes complete with bends/tees/joints, coupling plate and nuts, bolts etc. including providing and fixing of MS painted hanger etc. as required. 75x50mm
Supply and fixing of perforated 2mm thick CRCA sheet steel powder coated cable tray of following sizes complete with bends/tees/joints, coupling plate and nuts, bolts etc. including providing and fixing of MS painted hanger etc. as required. 150x75mm
Structural supports as required for cable trays complete with installation with anchor fastner/grouting as applicable. Painting with red oxide and 2 coats of enamel paint of colour as specified by Owner/Consultant.
Providing, laying, terminations of copper wire and strip of undernoted sizes in surface for connection etc. with lugs. 8 SWG wire
Providing, laying, terminations of copper wire and strip of undernoted sizes in surface for connection etc. with lugs. 25x6mm (strip)
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 25mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 50mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 100mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 150mm
Providing and fixing of Mild steel black pipes (IS: 1239 Part-I heavy class including cutting, welding/threaded joint and all fittings viz. Flanges, bends, tees, elbows, reducers, clamps, hangers, structural supports, nuts and bolts, gasket etc. Also cutting holes/ chasing in brick or RCC walls/slabs and making good complete, painting with one coat of primer (red oxide) and two or more coat of synthetic enamel paint to give and even shade of approved shade (for above ground piping). 200mm(6mm thick)
Providing and fixing FOOT VALVE WITH STRAINER with M.S. flanged connection. 100mm
Providing and fixing FOOT VALVE WITH STRAINER with M.S. flanged connection. 200 mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 80mm
Providing and fixing cast iron Dual plate spring loaded type non-return valve (as per technical specification) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects (PN 1.6) 150mm
Providing and fixing pressure gauge (0-10 Kg/Cm. Sq.) complete with isolation valve.
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 65 mm
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 80mm
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 100mm
Providing and fixing cast iron butterfly valve as per IS:13095 (PN: 1.0) including nuts, bolts, Minimum 1.5mm thick CAF gasket sheets, complete in all respects. 150mm
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 25mm
Providing and fixing G.M. stop valve ISI marked screws type tested as per IS: 778 of following size: 50mm
Providing and fixing gunmetal four way collecting head with 63mm dia instantaneous type inlet with built in check valve for fire brigade connection to underground tanks as per IS: 904.
Providing and fixing standard draw out connection with 63mm dia instantaneous type coupling with all accessories as approved by fire authorities for installation at under ground tank.
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 25mm
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 80mm
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 100mm
Providing and fixing black steel pipes to IS: 1239/3589 heavy class including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges etc. welding as required painting with one coat of red-odixe primer and two or more coats of synthetic enamel paints to give an even shade, cutting holes and chases in brick or RCC walls and making good complete. (For above ground piping). 150mm
Providing and fixing black steel pipe to IS: 1239 (Heavy Class) including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges, gasket etc. welding as required painting with coat of solvent based primer and wrapping with 5 layered corrosion protection tape 4.0mm or (4mm thick) conforming to IS: 10221 including necessary earth excavation and refilling, masonary supports complete in all respect. (For under ground piping). 80mm
Providing and fixing black steel pipe to IS: 1239 (Heavy Class) including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges, gasket etc. welding as required painting with coat of solvent based primer and wrapping with 5 layered corrosion protection tape 4.0mm or (4mm thick) conforming to IS: 10221 including necessary earth excavation and refilling, masonary supports complete in all respect. (For under ground piping). 100mm
Providing and fixing black steel pipe to IS: 1239 (Heavy Class) including all fittings like anchor fastners, couplings, bends, elbows, tees, flanges, gasket etc. welding as required painting with coat of solvent based primer and wrapping with 5 layered corrosion protection tape 4.0mm or (4mm thick) conforming to IS: 10221 including necessary earth excavation and refilling, masonary supports complete in all respect. (For under ground piping). 150mm
Providing and fixing gunmetal ISI marked obligue pattern fire hydrant valve with 80mm dia flanged inlet and 63mm dia instantaneous type female type lug and all accessories as per IS: 290-1983 'Type 'A' with hydrant matching flanges, gasket, nuts and bolts etc. complete in all respects. Single headed
Providing and fixing 63mm dia 15 Mtr. long flexible hose including gunmetal male and female instantaneous type coupling (IS: 903), machine wound with copper wire complete in all respects with ISI certification. RRL Hose pipe
Providing and fixing 63mm dia 15 Mtr. long flexible hose including gunmetal male and female instantaneous type coupling (IS: 903), machine wound with copper wire complete in all respects with ISI certification. CP Hose pipe
Providing and fixing of gun metal 63mm dia short branch pipe with 20mm dia nozzle, ISI marked (IS: 903).
Providing and fixing fire hose cabinet of size 900x600x300 fabricated from 16 gauge MS sheet of fully welded construction with hinged double front door with locking arrangements and partially glazed with 5mm thick glass stove enamelled fire red finish with fire hose written on front suitable to house 2x15 hose with couplings, one branch pipe (for external yard hydrants). Design to be got approved by Engineer-in-Charge before fabrication.
Providing and fixing first aid fire hose reel drum wall mounting swinging type fitted with 36 mtrs. 20mm dia high pressure rubber hose to IS: 5132 with 5mm outlet gunmetal nozzle with shut off valve (IS: 884).
Providing and fixing G.M. stop valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes. 25mm
Construction of brick masonary chamber 1200x1200 inside 75 class designation brick work in cement mortar 1:5 for sluice valve with CI surface box 400x400x75mm inside with hinged cover fixed in M-15 grade cement slab and necessary excavation foundation concrete 1:5:10 and inside plastering with cement mortar 1:3 finished with a floating coat of neat cement complete as per standard design with FPS bricks.
Providing and laying of hume pipe NP-2 class conforming to IS: 458 at road crosing with excavation, back filling, ramming and making good in all respects. 300mm
Providing and fixing cast iron slim seal wafer type non-return valve (as per IS: 5312) including nuts, bolts, 1.5mm thick CAF gasket sheets complete in all respects. 100mm
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 80mm
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 100mm
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 150mm
Providing and fixing gunmetal 2 way fire brigade connection head with 63mm dia instantaneous type inlet with built in check valves for fire brigade connection to fire risers (IS: 904-1965). A wall mounted box of MS construction with glass door to house the above mentioned components.
Providing and fixing portable fire extinguisher water type (gas cartridge) with cylinder fully charged of 9 litres capacity complete with standard discharged valve with tube CI bracket for wall mounting etc. conforming to IS: 940.
Providing and fixing portable fire extinguisher, dry powder type (gas cartridge) with cylinder initially fully charged with dry powder (ABC type) of 5 Kg. Complete with standard discharge valve with tube, CI bracket for wall mounting etc. conforming to IS: 2171.
Providing and fixing portable fire extinguisher carbon dioxide type with cylinder initially fully charged with CO2 gas of 4.5 Kg. Capacity, complete with discharge valve, dishcarge tube, horn, CI bracket for wall mounting etc. conforming to IS: 2878.
Providing and fixing portable fire extinguisher mechanical foam type with cylinder initially fully charged with foam compound of 9 litres capacity, complete with standard discharge valve with tube CI bracket for wall mounting etc. conforming to IS: 10204.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 25mm dia.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 65mm dia.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 80mm dia.
Providing, fixing, testing and commissioning of mild steel black pipes (IS: 1239 Part-I) heavy class including cutting welding etc. and providing all fittings viz., flanges, bends, tees, elbows, reducers, clamps, hangers etc. wall/slabs and making good complete including painting with one coat of primer and two or more coats of synthetic enamel paint of approved shade. 100mm dia.
Providing, fixing, testing and commissioning of gun-metal ball valves ISI marked screwed type tested to pressure as per IS: 778 of following sizes: 25mm dia.
Providing, fixing, testing and commissioning of 15mm dia horizontal (side wall type) bulb type sprinkler set to operate at 57 Deg. C (UL/FM/FOC/TAC listed/approved).
Providing, fixing, testing and commissioning of 15mm dia horizontal (extended side wall throw) bulb type sprinkler set to operate at 57 Deg. C (UL/FM/FOC/TAC listed/approved).
Providing, fixing, testing and commissioning pendent/upright of 15mm dia quartzoid bulb type sprinkler set to operate at 57 deg. C (UL/FM/FOC/TAC listed approved).
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 80mm dia.
Providing and fixing double flanged cast iron butterfly valves complete with bolts, nuts 1.5mm CAF gasket complete conforming to IS: 13095. 100mm dia.
Providing and fixing M.S cabinet fabricated from 16 gauge M.S. sheet with double front glass door and locking arrangement with suitable shelves including space for 50 spare sprinkler and one spanner properly fixed in the shelves and cabinet painted with enamel paint of approved shade, size 900x600x150mm.
Providing and fixing installation control valve with turbine type automatic alarm gong with quarter mile hooter, also with control valve drain and test drive as per manufacturer's speicifcations. (Size 80mm dia).
Providing and fixing gunmetal 2 way fire brigade connection head with 63mm dia instantaneous type inlet with built in check valves for fire brigade connection to sprinkler system (IS: 904-1965). A wall mounted box of MS construction with glass door to House the above mentioned components.
Providing and fixing cast iron slim seal wafer type non-return valve (as per IS: 5312) including nuts, bolts 1.5mm thick CAF gasket sheets complete in all respects. 100mm
Supplying, fitting fixing of LED Batten Tubes high quality aluminium extruded with decorative end caps connection with 1.5 Sq.mm 1 core PVC insulated round copper conductor as required and as directed by the department. BN021C LED 20 PSU CW GR S2 [TL]
Supplying,installation,testing and commissioning of the following integral flood lighting luminaires conforming to IP 65 / IP 66 suitable for vertical and horizontal mounting applications pressure die cast powder coated aluminium alloy housing with corrosion resistance powder coating using nano Technology transparent injection moulded poly carbonate UV stabilized diffuser having high impact strength to withstand min IK09 with high power LED and unique flood optics to ensure uniform light distribution and maintenance free system ideal for area lighting, high mast lighting, sports lighting and billboard. The luminaires should be equiped with external surge protection device to withstand 10 KV / 5KV including connection with 2.5 sqmm 3 core PVC insulated round copper conductor as required and as directed by the department. BVP 120 LED 35 CW FG S1 PSU GR [CH ]
Supply, Installation antistatic rubber mat suitable for 1.1 KV Voltage grade
Supply, Fitting Fixing of Shock Treatment Chart
Supplying, installation, testing and commissioning of pressure die cast powder coated aluminium alloy housing frosted PC diffuser, IP65/IP66 protection with build in LED of the following landscape luminarie ( POST TOP ) suitable for 38mm dia post top mounting applications including connections with 2.50 sq.mm 3core multistrand P.V.C. insulated round copper cable as required and directed by the department. [PTL] CROMPTON MAPLE CAT REF: LPTO-60-CDL/M
Providing and fixing multi vent roof ventilators(Turbo ventilator)on the top of roof with high performance industrial multi vent room ventilator of minumum 530 mm dia neck/throat of Aluminium alloy designed to a capacity of 1850 CFM including FRP(Fibre Reinforced Plastic) venture dome 1.5 mm thick and all require accessories as per technical specification.Multi roof ventilators to be got approved from E.I.C. before installation .The rate includes cutting /making holes in the roofing sheet
Providing and Laying Block masonary out of best available 1st class Aerated Autoclave Blocks of specified thickness of desired conpressive strength(certificate to be produced) as per drawing and details,inline,level and plumb for superstructure at all heights,including galabid ,bagle wall,load walls ,columns, pillasters,etc , in cement motor 1:6 includingscaffolding,racking of joints,curing etc,complete as per drawing and specification(rate should be including scaffolding.
Granular Sub-base with Well Graded Material (Table 400.1)(Only for PMGSY work) (A) By Mix in Place Method Construction of granular sub-base by providing well graded material, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with smooth wheel roller to achieve the desired density, complete as per Technical Specification Clause 401. (ii) For Grading II Material
WBM Grading 2 Using stone screening Type-B 11.2 mm for Gr.II Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening/binding materials to fill- up the interstices of coarse aggregate, watering and compacting to the required density grading 2 as per Technical Specification Clause 405. (A) By Manual Means
WBM Grading 3 Using stone screening Type-B 11.2 mm for Gr.III Providing, laying, spreading and compacting stone aggregates of specific sizes to water bound macadam specification including spreading in uniform thickness, hand packing, rolling with smooth wheel roller 80-100 kN in stages to proper grade and camber, applying and brooming, stone screening to fill-up the interstices of coarse aggregate, watering and compacting to the required density Grading 3 as per Technical Specification Clause 405. (A) By Manual Means
Inter locking concrete Block pavement (A) Interlocking pavement block i Providing and laying interlocking concrete block pavement (M40) having thickness 80mm as per technical specification clause 1504 complete a) Including Edge block/ Edge restraintscarriage
A provisional sum of Rs 5,85,000.00 (Rupees Five Lakh Eighty Five Thousand Only) for resettlement of existing temporary market sheds and EMP requirements is provided and to be operated and expended in whole or in part at the instruction of Engineer-in-Charge
Md. AsabUddin Choudhury
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .