Loading…
Loading…
| # | Company | Amount | Status |
|---|---|---|---|
| 1 | ₹14.5 Laccepted-aoc | ₹14.5 L | accepted-aoc |
Tender Value
₹16.9 L
EMD Value
₹43,000
Closing Date
9 Apr 2026, 10:59 pmClosed
Rural Drinking Water and Sanitation Department
DHANALAKSHMI
Drilling of New Borwel and Instaling Pump Motor at Nanjaina Colony, Annuru, Chikkere Hadi and Annuru Girijna Hadi Village and Replacement of Existing Raising Main at Malaradahundi Village in H D Kote Taluk
RWSSD/2025-26/WS/WORK_INDENT9923
RWSSD/2025-26/WS/WORK_INDENT9923
Open
Water supply/sewage lines
Two Tender Document System(Two Cover)
RWSSD Division Office Mysuru
₹500
₹43,000
9 Apr 2026
1 Apr 2026
10 Apr 2026
2 Apr 2026
Drilling of New Borwel and Instaling Pump Motor at Nanjaina Colony, Annuru, Chikkere Hadi and Annuru Girijna Hadi Village and Replacement of Existing Raising Main at Malaradahundi Village in H D Kote Taluk
Sinking of Borewell of 165 mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m.Fixing of casing pipes, collars and ...
Sinking of Borewell of 165 mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m.Fixing of casing pipes, collars and ...
Sinking of Borewell of 165 mm dia clear using super fast hydraulic rig of capacity 300 PSIG & above 1100 CMF & above in all strata including over burdern upto 20 m.Fixing of casing pipes, collars and ...
Supply of ISI mark 175mm nominal bore,plain and steel casing pipe grade of steel Fe 410 of wall thickness conforming to IS 4270-2001 and latest ammendments, electrical resistance welded steel tubes, m...
Providing and laying at site of work MS casing caps as per IS 1239 (part II) 1982 with all latest amendments if any for any dia. The thickness of plate used for covering one end shall be 3mm (minimum)...
Providing Submersible Pump Set of 150mm dia suitable for bore well and confirming to IS 8034-2000;3Phase, SS Bowl & Impeller with Low volt Motor as per specifications, to work site as per necessary am...
Supply and delivery of galvanized mild steel tubes of 6mtr standard length heavy duty (C Class) as per IS 1239 (Part-I) 1990 with latest amendments with ISI Mark (one end fitted with Heavy Duty collar...
Supply and delivery at site Brand new best make PVC insulated cable of Flat 3 core(sheathed) of nominal cross sectional area as per IS 694-1990 with ISI Mark and as per its latest amendments.1x3x6 Sqm...
Labour charges for Erection, Electrification and commissioning of Pump sets, including aligning and balancing of all items including supply and erection of two pair of supporting clamps, bore well cap...
Supply, installing,testing and commissioning COMMON control panel consisting of the following INCOMING:1 No set of Phase indicating lamps with SFU of suitable rating 1 No, Analog Ammeter, 1 No Analog ...
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments: (SR 2023-24 V5 Item no 13.24.1 Page No 154) Size 50 mm
Supply and delivery at site of brand new best make non-return valve as per IS 778/1984 with ISI Mark and as per its latest amendments (SR 2023-24 V5 Item no 13.25 Page No 154) 13.25.1 Size 50 mm
Earth work excavation by manual means for drains,canals, waste weir,draft, approach channels, key trenches, foundation of bridges and such simillar works in all kinds of soils , as per drawing and tec...
Providing and laying in position plain cement concrete for levelling course for all works in foundation. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS...
Providing Coursed rubble masonry (second sort) with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)(1 cement : 6 coarse sand)
Providing Size Stone masonry with hard stone in foundation & plinth with Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and laying in position Cement Concrete for all Foundation works. The granite/trap/basalt crushed graded coarse aggregates and fine aggregates as per relevant IS Codes machine mixed with supe...
RCC hume pipe Circular pump house: Providing precast RCC Circular Hume pipe pump house with M.S door and RCC conical roof as per specification and drawings - Internal dia Mtr. 1200 mm & height of 2.5 ...
Erection and positioning of RCC Hume pipe pump house/Cistern on size stone masory platform including transportation charges and handling,finishing with all necessary tools ,plants and materials etc.,c...
Providing 6 mm cement plaster with cement mortar 1:3 (1 cement : 3 fine sand) on concrete surface / ceilings including rounding off corners wherever required smooth rendering, providing and removing s...
Finishing walls with textured exterior paint of required shade :New work (Two coats applied @ 3.28 ltr/10 m²) over and including priming coat of exterior primer applied @ 2.20kg/10 m² to give an eve...
Earth work excavation for pipelines/cables by Manual means upto 600 mm trench width, as per drawing and technical specifications, including setting out, shoring, strutting, barricading, caution lights...
Providing, laying and jointing HDPE pipes of specified grade and conforming to IS 4984-2016 with latest ammendments and conveying to work site including loading and unloading at both destinations and ...
Supply and delivery at site of brand new best make gate valve as per IS 778/1984 with ISI Mark and as per its latest amendments - 50mm
Supplying and wiring adopting loop system in existing PVC Conduit/casing capping using 2x1.5mm2 (Phase & Neutral) & 1x1.0 mm2 (Earth wire) FRLS multi strand PVC insulated copper wire (confirming to IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Wiring for lighting/power circuit using one of FRLS PVC insulated 1100V grade, multistrand copper wire with low conductor resistance single core in open or concealed system of wiring with specified IS...
Supplying PVC/GI flexible conduit pipe mm dia fixing on surface over inverted tapered wooden plugs or phill plugs or rawl plugs and clamped using heavy gauge saddles at an interval of 300 mm using NF ...
Supplying and fixing of ….mm dia class A GI pipe bracket up to 2 mtrs long bent at suitable angle and fixing to this bracket 1x40/2x40 watts fluorescent tube street light fitting of all capacities t...
Supplying of TPST with rewirable porcelain channels in SM enclosure. Made out of 14 SWG powder coated paint of approved colour. 32A
Supplying & fixing of Porcelain fuse channel with cut out on existing wooden/panel using necessary nuts, bolts and washers.32A
Supplying & fixing miniature circuit breakers on existing MCB distribution boards using necessary fixing materials and 'C' Type curve, indicator ON/OFF, energy cross-3 with Short circuit breaking capa...
Supplying, fixing and wiring heavy duty low voltage capacitors conforming to IS 2834. 3 phase, 400/440 V grade, for power factor improvement of rotating machineries like induction motor.
Supplying fixing and wireing earth electrode for grounding conduits IC cutouts and other equipments on the metal board using 40mm dia, 2.90 mm thick GI pipe 2.5 Mtr. Long burried in a pit. The pit sho...
Providing and laying in position 100mm dia stone ware pipe inexistingtrench.(70/8)
Supplying and fixing of class A (medium duty) GI pipe of wall thick ness not less than 3.25mm on pole/ wall/drain crossing with necessary clamping arrangements for UG cable of 1.1 KV class.(70/9) 40mm...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
kw1 OHT 9923.docx
Tender Document • 0.22 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .