Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC | L1 | Accepted-AOC Accepted | |
| 2 | L2₹46.2 L+₹58,570 (1.28%)Rejected-Finance | L2 | Rejected-Finance NOT ADMITTED BEING L2 | |
| 3 | L3₹46.3 L+₹73,959 (1.62%)Rejected-Finance FLAT NO 201 GREEN VALLEY CHS PLOT NO 26 SECTOR 19 NERUL EAST NAVI MUMBAI 400 706 | THANE | MAHARASHTRA | 400706 | L3 | Rejected-Finance NOT ADMITTED BEING L3 | |
| 4 | L4₹46.9 L+₹1.3 L (2.90%)Rejected-Finance 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L4 | Rejected-Finance NOT ADMITTED BEING L4 | |
| 5 | L5₹46.9 L+₹1.3 L (2.90%)Rejected-Finance | L5 | Rejected-Finance NOT ADMITTED BEING L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
5 Sept 2024, 6:00 pmClosed
GE NW KARANJA
NAVAL STATION KARANJA, URAN, RAIGAD, MAHARASHTRA
REPAIR REPLACEMENT OF INTERNAL WIRING FITTING FIXTURE ALONGWITH DISTRIBUTION BOARD MCCB METER PANEL LED LIGHT FITTINGS AND OTHER MISC WORKS FOR MD ACCN AT NAVAL STATION KARANJA
2024_MES_662922_1
8931/E8
Open Tender
Electrical and Maintenance Works
Item Rate
243 days
GE NW KARANJA
D and above b i
8 documents required · 8 mandatory
₹500
Yes
GE NW KARANJA
₹96,000
Yes
12 Oct 2024
29 Jun 2024
7 Sept 2024
29 Jun 2024
5 Sept 2024
18 Jul 2024
Amount
Notes : (i) The work consists of 01 job as under:- JOB (A) : TPP 2024-2025 Ser No.57 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
Taking down carefully copper /aluminium point wiring (light, fan socket or power) through stove enamelled steel conduit/pvc conduits including complete fittings such as switches, ceiling roses, pendants, regulators, sockets,, switch sockets, electrical fittings etc removing and making good disturbed surfaces of walls/ceiling etc, all as specified and directed.
M&L for concealed point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in & including in CONCEALED PVC , including all accessories as approved by EIC by cutting charges and making good with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire of green colour for continous earth, including sunken box made out of approx 1.20 mm thick and not less than 60 mm in depth GI/MS/ pressed steel terminal box to be concealed in wall, duly painted including laminated hylum/maonite sheet cover thickness 3mm for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer for the following complete all as specified and directed :- Note :- Wiring to be done as per approved colour code & casing / capping on ceiling deem to be included in point wiring.
One light /fan/ call bell point controlled by one switch
One 5 pin socket outlet 5 Amps on independent board
One 5 pin socket outlet 5 Amps on same board
All as per BOQ Serial item No 3.00 above but, One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item No 3.00 above but, with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board.
M&L for point wiring with 1.5 Sqmm single core, multi stranded copper conductor 1100 V grade, ISI marked , PVC insulated unsheathed cable (with approved colour code) FRLSH cable drawn in and including casing caping of 25 mm wide, with double locking type,including all accessories casing caping as approved by EIC, with PVC 1.5 mm multi stranded insulated unsheathed FRLSH copper wire of green colour for continous earth, including sunken box made out of approx 1.20 mm thick and not less than 60 mm in depth GI/MS/ prssed steel terminal box to be conclead in wall, duly painted including 3mm hylum /masonite sheet cover, for mounting of fittings like switches, sockets, fan regulators etc. fixed with galvanised screw and cup washer complete all as specified and directed. Note : Wiring to be done as per approved colour code.
All as per BOQ Serial item No 5.00 above but for one light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item No 5.00 above but for one 5 amp socket point on same board
All as per BOQ Serial item No 5.00 above but for one 5 amp multi socket indepenedent
All as per BOQ Serial item No 5.00 above, but using 2.5 sqmm ( nominal area) multistranded FRLSH copper conductor cable/wire & 2.5 sqmm size PVC insulated unsheathed copper conductor cable for earth continuity ( green colour) for one 5 pin socket outlet 5 / 15 Amp multi purpose independent point controlled by 15 Amp switch, SP one way, 240 Volts & Socket, complete all as specified and directed.
All as per BOQ Serial item No 5.00 above but using 4 sqmm (nominal area) FRLSH multistranded copper conductor cable/wire for one 5/15 Amp socket point controlled by 15 Amp switch, SP one way 240 Volts & Socket, complete all as specified and directed.
M & L Point wiring with PVC insulated unsheathed electric cable 1100 volts grade, single core,FRLSH cable having multistranded copper conductor of 1.5 Sqmm nominal cross sectional area, drawn in existing concealed conduit/surface conduit with 1.5 Sqmm green PVC insulated unsheathed multistranded copper conductor FRLSH cable, as continuous earth conductor connected to earth dolly by providing suitable lugs including 3.0 mm thick new laminated hylum sheet /masonite sheet cover of suitable sizes to be fixed/ mounting on existing MS/ GI sunkun boxes for mounting of fittings like switches, sockets, fan regulators etc fixed with galvanised screw and cup washer. complete all as specified and directed for the following. Note : Wiring to be done as per approved colour code.
One fan/exhaust fan point controlled by one switch
One 5 pin socket outlet 5 Amps on same board
One 5 pin socket outlet 5 Amps on independent board
One light point controlled by 2 way switch SP, 5 Amp, 240 Volts
All as per BOQ Serial item, No 11.00 above but with 2.5 sqmm multi stranded copper conductor 1100 volts grade FRLSH PVC insulated sheathed cable with FRLSH PVC 2.5 Sqmm multi standard insulated unsheathed copper wire for continues earth on independent board complete all as specified and directed.
S&F switch piano flush button single pole one way, 6 Amp complete all as specified and directed.
S&F Switch socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
S&F Socket outlet 2 in 1, 3 pin, 6 Amp flush type complete all as specified and directed.
S&F Switch bell push flush type 5 Amp all as per complete all as specified and directed.
S&F Switch socket combination outlet 15 Amp, 5-in-1, controlled by one switch complete all as specified and directed.
S&F Switch flush button, single pole two way, 6 Amp complete all as specified and directed.
S&F Socket type EME fan 5 step regulator for ceiling fan of suitable size, complete all as specified and directed.
S&F Lamp holder/angle holder insulated body with black/white plate for batten fittings complete all as specified and directed
S&F modular step type fan regulator 120 watt ,AC, 220V, 50hz complete all specified and directed.
S&F modular switch 1 module 6 amp one way complete all specified and directed.
S&F modular switch 1 module 16 amp one way complete all specified and directed.
S&F modular socket 2 module universal type 5/6 amp one way complete all specified and directed.
S&F modular socket 2 module universal type 6/16 amp one way complete all as specified and directed
S&F modular bell push 6A 1 module complete all as specified and directed all specified and directed.
S&F Bell buzzer, ding dong AC,230V, 50hz single pole complete all as specified and directed . Note :- (BOQ Serial item No 12.00 to 26.00) This item shall also be used as 'in repairs' of existing ones as per site requirement and nothing extra shall be paid.
S&F in repairs modular cover plates with frame up 1 /2 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes complete all as specified and directed.
S&F in repairs modular cover plates with frame up 3 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes complete all as specified and directed.
S&F modular cover plates with frame up 4 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes complete all as specified and directed.
S&F in repiars modular cover plates with frame up 6 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes complete all as specified and directed
S&F in repairs modular cover plates with frame 8 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes complete all as specified and directed
S&F in repairs modular cover plates with frame 12 module as per site requirements apart from the rates included in the point wiring for cover plates and metal flush boxes complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 1/2 modules complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 4 modules complete all as specified and directed. Note :- Metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs.
S&F in repairs modular metal flush box as per site requirements 6 modules complete all as specified and directed. Note :-Metal flush boxes considered in this item only for the maintanance of switches of existing modular fitting qtrs.
S&F in repairs modular metal flush box as per site requirements 8 modules complete all as specified and directed.
S&F in repairs modular metal flush box as per site requirements 12 modules complete all as specified and directed.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn and including non metallic rigid PVC conduit of 25mm dia/casing capping , including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down complete all as specified and directed. Note :- For concealed submain work cutting and chasing measured and paid seperately.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in and including non metallic rigid PVC conduit of 25mm dia/casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete including taking down complete all as specified and directed.. Note :- For concealed submain work cutting and chasing measured and paid seperately.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in and including non metallic rigid PVC conduit of 25mm dia/casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 10.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surface/ recess complete including taking down complete all as specified and directed. Note :- For concealed submain work cutting and chasing measured and paid seperately.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 4.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 4.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly complete including taking down complete all as specified and directed.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 6.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking down complete all as specified and directed.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 10.0 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 6.0 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking down complete all as specified and directed. Note :- For concealed submain work cutting and chasing measured and paid seperately.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in and including non metallic rigid PVC conduit of 20mm dia/casing capping , including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly in surfaces/ recess complete including taking down complete all as specified and directed.
M&L for Sub main wiring with two runs of single core PVC insulated unsheathed cable 1100 volts grade, multistranded copper conductor FRLSH cable of 2.5 Sqmm (with colour code), drawn in existing surface/ recessed steel/ PVC conduit/ PVC casing capping, including one run of PVC insulated unsheathed, multistranded copper conductor FRLSH cable of 2.5 Sqmm (Green colour) as contineous earth conductor cable connected to earth dolly including taking downall complete all as specified and directed . Note :- For concealed submain work cutting and chasing measured and paid seperately.
M&L cutting of wall/ceiling/column for laying submain of any size including plastering ,white wash complete all as specified and directed
S&F in repairs LED building security light fitting with suitable size bracket/angle with three core flexible wire to fit security light of 45 w IP 66 protection LED complete all as specified and directed.
S&F in repairs LED batten with 20/22W LED tube light 4 feet in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed
S&F in repairs LED batten with 24W LED tube light 4 feet in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed
S&F DB 12 way, 100 Amp bus bar openable type double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection including taking out old unsv MCB DB any size/type complete all as specified and directed
S&F DB 8 way 100 Amp bus bar double door openable type double door MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection , including taking out old unsv MCB DB any size/type complete all as specified and directed
S&F, DB 4 way double door, openable type MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection ,including taking out old unsv MCB DB of any size/type complete all as specified and directed.
S&F, DB 2 way MCB DB made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection including taking out old unsv MCB DB of any size/type complete all as specified and directed.
S&F double door MCB VTPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar ,including taking out old unsv MCB DB of any size/type complete all as specified and directed
S&F double door MCB TPN DB 4 WAY made out of 18SWG CRCA steel sheets, Phosphates powder coated with copper bus bar, Earth stud, Din Rail, Polyamide Terminal Blocks for incoming and outgoing circuits, inbuilt loose wire box, Ground terminal blocks, duly pre-wired with thimble flame retardant copper conductors and poly layer for protection SP 240 volts 200 Amps rated bus bar 4 way ,including taking out old unsv MCB DB of any size/type complete all as specified and directed
S&F 6 to 32 AMP MCB single pole 240 V 10 KA (C-Series) complete all as specified and directed.
S&F SPN 32 AMP MCB DP 240 V 10 KA (C-Series) complete all as specified and directed.
S&F in repairs LED recess/surface mounted 2x2 luminarie 36w fitting, 220 V, AC,50HZ suitable surge protection, high power factror,driver etc complete including flexible wire and connected accessories complete all as specified and directed
S&F in repairs LED Bulk head fittings 9/10W luminaire including LED light driver holder 220 V, AC,50HZ connecting up with three core flexible copper conductor calbe of suitable size complete with all acccessories complete all as specified and directed.
S&F in repairs LED tube rod 20 watt, 4 feet, 220V,AC,50HZ change with existing any tube rod including flexible wire and connected accessories complete all as specified and directed.
S&F in repairs batten MS suitable 4 feet for 18/22/24W LED rod 220V,AC,50HZ with accessories including suitable 1.5 sqmm 2 core wire for connecting with ceiling rose complete all as specified and directed.
S&F in repairs LED batten 10w, 2 feet with LED tube light 220V,AC,50HZ in wall/surface connecting with all required accessories like flexible cable from ceiling rose etc complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 100 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified.
S&F in repairs MCCB 4 pole, thermal magnetic release range 125 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified.
M& L for daily complaint checking & repairing of DBs/meter panel board/circuits/submain wiring/switches/sockets etc and other connected work including rectification of faults complete all as specified and directed
S&F in repairs MCCB 4 pole, thermal magnetic release range 63 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified.
S&F in repairs MCCB 4 pole, thermal magnetic release range 40 Amps of breaking capacity 16 kA, 415 Volts, 50 Hz, complete all as specified.
Taking out cover plate of bus conductor duct of multistoreyied building,inspection cleaning, servicing including replacement of rusted nuts bolts,insulators etc ,cutting of damage end of outgoing cables and reconnection using proper size of cable lugs and preparation of old painted surface by scrapping and brooming down and material and labour for two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F in repairs three pin top of capacity 15 amp ,AC,220V complete all as specified and directed
S&F in repairs PCRD plug of capacity 15 amp ,AC,220V complete all as specified and directed
S&F in repairs epoxy coated connector of capacity 100A post type for bus bar trunking system complete all as specified and directed
Taking out two wire from meter and bus bar/MCB SPN/SP with keeping in veiw safety and replaced with 2 run of 6 sqmm wire of meter with suitable size of cable lugs both end and reconnection with meter and bus bar/MCB SPN/SP complete all as specified and directed. NOTE : Rate of lugs will deemed to be included in quoted rate by the contractor.
S&F in repair sunken/terminal box of size 10x10cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
S&F in repair sunken/terminal box of size 15x7.5cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
Taking down carefully by unscrewing from boards/ outlet boxes, fittings and fixtures such as switches, sockets, ceiling roses, lamp holders, brackets, ceilingfittings, bulk head fittings, tube light fittings and regulators, etc. for reuse at site or carrying to the store/ take in soc complete all as specified and directed
S&F in repair sunken/terminal box of size 20x15cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
S&F in repair sunken/terminal box of size 20x25cm, concealed/surface mounted alongwith hylam sheet for fixing existing switches, sockets & regulators etc and making good disturbed surfaces of walls complete all as specified and directed
S&F in repairs emergency bulb LED 10W, 230V, 50Hz, with 4 hour backup complete all as specified and directed.
S&F in repairs round/square type, recessed /surface 12W/14W warm white LED downlight dimmable with high lumen 230V, compatible with Legrand Dimmer as per sample complete all as specified and directed
S&F in repairs RCCBs 63 Amps double pole 100mA breaking capacity complete all as specified and directed.
S&F in repairs RCCBs 40 Amps double pole 100mA breaking capacity complete all as specified and directed.
S&F in repairs decorative light suitable for holder B-22/E-27 complete all as specified and directed
M&L for taking out and refixing of tube light,mirror light etc after cleaning and any type rectifiying defect complete all as specified and directed
S&F in repairs LED batten with 20W LED tube light (four feet) with sensor in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified
S&F LED batten with 9/10 W LED tube light two feet mirror type with sensor in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as directed and specified
S&F in repairs LED batten with 20W LED tube light (four feet) with inverter type with 2 hrs backup in wall/surface connecting with all required accessories like PVC box base,flexible cable from ceiling rose etc Surface and wall mounted LED batten, Engineering plastic batten with accessories complete all as specified and directed
S&F in repairs LED bulb of 9/10 watt acomplete all as specified and directed
M&L for servicing and cleaning of geyser of any capacity including taking out from existing position and refixing complete all as specified and directed
M&L for checking ceiling fan of size 1200/1400mm and change defective part cotter pin/ nut bolt etc complete all as specified and directed
S&F in repairs fan rod of size 1/1.5 feet suitable for mounting ceiling fan of size 1200/1400 mm complete all as specified and directed
S&F LT PANEL consisting space to fix a 9 nos meter and providing 9 nos MCB DP 40 with enclosure for protection of METER. single door fixed type wall mounted PTTA A DLEC model CRCA sheet enclousure. The rates including taking down old meter and connecting in new panel with required wires with out any extra cost complete all as specified and directed.The panel should cosists of the following :- INCOMING (1) MCCB 100 AMP 4 P 25 Ka thermal magnetic based with o/c, s/c protection & ROH - 01 nos (2) Indicating lamps RYB-03 nos. (3) Digital type voltmeter and ammeter. OUT GOING : (1) 40 amp MCB DP 10 ka with enclosure-9 nos. (2) Space for refixing existing/Automatic meter electrical meter -09 nos. NOTE-Contractor shall visit the site to prepare panel as per size required to fit in below stair case.
S&F LT PANEL consisting space to fix 5 nos meter and providing 5 nos MCB DP 40 with enclosure for protection of METER . single door fixed type wall mounted PTTA A DLEC model CRCA sheet enclousure. The rates including taking down old meter and connecting in new panel with required wires with out any extra cost complete all as specified and directed.The panel should cosists of the following :- INCOMING (1) MCCB 100 AMP 4 P 25 kA thermal magnetic based with o/c, s/c protection & ROH - 01 nos (2) Indicating lamps RYB - 03 nos. (3) Digital type voltmeter and ammeter. OUT GOING : (1) 40 amp MCB DP 10 ka with enclosure-5 nos. (2) Space for refixing existing /Automatic meter electrical meter -06 nos. NOTE-Contractor shall visit the site and to prepare panel as per size required to fit in below stair case.
S&F in repairs two way sheet metal enclosure with and including three pin socket and plug top and 20 amp single pole MCB complete all as specified and directed .
Nexus Infratech (BID ID -3074350)
M.K Enterprises (BID ID -3073746)
Sagar Electricals (BID ID -3074649)
LAXMI ENTERPRISES (BID ID -3077456)
M/s. Prakash Construction (BID ID -3071480)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .