Bangalore University
University Engineer
REPLACEMENT OF WORN OUT HT AND LT POWER TRANSMISSION LINES, RCC POLES, PIN & DISC INSULATORS
BU/2026-27/EL/WORK_INDENT66/CALL-3
BU/2026-27/EL/WORK_INDENT66/CALL-3
Open
Electrical
Two Tender Document System(Two Cover)
Registrar Office Bangalore University
9 documents required · 9 mandatory
Minimum financial turnover (civil engineering construction works) not less than two times the annual payments from this contract (Rs. xxxxx Lakhs)
Satisfactoriy completed (atleast 90%) as prime contractor at-least one such similar work of value not less than Rs. xxxxxxx (80% of estimated cost of tender)
Executed in any one year the following minimum quantities of work (Cement Concrete - xxxx cum, Earthwork - xxxx cum, etc) (80% of peak rate of construction)
Tenderer or his identified Sub Contractor should possess valid Electrical License for executing building electrificatio works and should have executed similar electrical works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Tenderer or his identified Sub Contractor should possess valid license for executing water supply / sanitary engineering works and should have executed similar works totallng Rs. xxxxxx (not less than 50% of electrical works) n any one year
Owning the following key and critical equipment for this work (xxxx, xxxx, xxxx)
Liquid assets and /or availability of credit facilities of no less than Rs. xxxxxx Lakhs (estimated cash flow for 3 months of peak construction period)
Total value of civl engineering works executed and payments received in the last five years (year-wise)
List of existing commitments and ongoing works
List of works for which tenders already submitted
Banker Details for reference
Construction equipment owned by the tenderer and equipment proposed to be deployed on this contract, if awarded
Reports on the financial standing of the tenderer, such as profit and loss statements and auditor’s reports for the last five years
Qualification and experience of the key technical and management personnel in permanent employment with the tenderer and those that are proposed to be deployed on this contract, if awarded
List of Financial Resources with Certificates
The tenderer should have completed satisfactorily one similar nature of Electrical HT work within the stipulated period of value not less than Rs.32.30 Lakhs during last Five years
Contractors with Karnataka PWD license of Class-III and above Electrical Licence
Statements showing the value of existing commitments and on-going works as well as the stipulated period of completion for each of the work listed should be countersigned by the employer in-charge, not below the rank of Executive Engineer or equivalent
Calculated Assessed available tender capacity and self attested in their respective company letter heads
Should submit details for Executed in any one year during past 5 Years the following minimum quantities of work (ACSR Conductor- 14.00KM, LT Cable-2 KM and Pole (RCC, PCC or equivalent)-100 Nos. etc)
Liquid assets and / or availability of credit facilities of not less than Rs. 19.40 Lakhs (Credit lines/letter of credit/ certificates from banks for meeting the fund requirement) from nationalized/Scheduled banks issued after the date of notification for this work
Minimum financial turnover of Rs. 64.57 Lakhs should be achieved in any two years during the last five years
Income Tax Returns filed by the contractor during the last three Financial years should be
₹1,620
₹1.3 L
13 Jul 2026
13 Jul 2026
30 Jul 2026
28 Jul 2026
REPLACEMENT OF WORN OUT HT AND LT POWER TRANSMISSION LINES, RCC POLES, PIN & DISC INSULATORS AT JNANABHARATHI CAMPUS, BANGALORE UNIVERSITY, BANGALORE.
Drawing of ACSR conductor as per IS: 398 (Part - 2/1996) are the latest revision including labour charge complete.Rabbit ACSR (6/3.35 mm Al+1/3.35 mm st) std wt:214 Kg/KM ---- With all lead and lift i...
Drawing of ACSR conductor as per IS: 398 (Part - 2/1996) are the latest revision including labour charge complete. Conductor Coyote ACSR ---- With all lead and lift including cost and conveyance of al...
Drawing of 1.1 kV, LT Aerial Bunched Cable, confirming to IS:14255:1995 XLPE insulation Parameter.3x95 + 1x70 + 1x16 Sqmm Street light (Insulated Messenger cum Neutra ---- With all lead and lift inclu...
Accessories for ABC cable as per NF-33, as per IS-13573 for joints and terminations Suspension clamp suitable for insulated messenger wire of size 25 to 95 sq mm ---- With all lead and lift including ...
Supplying of RCC Pole 9 mtr long 145 Kg WL Dwg No. BESCOM GM QS S 02 dtd 24.11.2018 as per IS 785. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of al...
Erection of RCC Pole 9 -10 mtr long in a pit of 1.8 Mtr depth ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all ...
Supplying 11KV Horizontal cross arm - Galvanised Iron (Dwg No. BESCOM/GM/QS&S/02 dtd 24.11.2018 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all m...
Fixing of V-shape /Horizontal cross arm including single top support brace and insulator fixing. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all ...
Supplying LT 4pin Cross arm Galvanised Iron ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental c...
Fixing of 4pin cross arm with insulator and braces fixing ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all othe...
Supplying 11KV GI pin for 11KV Ceramic Shell Insulator ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other i...
Releasing and fixing Insulator of 11KV Pin Insulator ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other inc...
Supplying 1.1KV GI pin for 1.1KV Ceramic Shell Insulator ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other...
Supplying 90 KN Disc insulator for HT Line for GOS ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incid...
Labour charge for digging of Pit for Guy set. Hard Soil ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other ...
Fixing of GUY set with break insulator making use of 7/3.15mm (7/10 SWG) galvanised steel wire with turn buckle and anchoring arrangements as per approved drawing.(Excluding excavation of PIT ---- Wit...
Supplying 11KV HG Fuse Unit with solid core insulator. (Dwg No. BESCOM/GM/QS&S/02 dtd 24.11.2018 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all ...
Supplying 11KV DOLO cutout REC specification. (Dwg No. BESCOM/GM/QS&S/35&63. dtd 24.11.2018 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machi...
Fixing DOLO cutout/Horn Gap fuse including fixing of cross arms and wiring. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equip...
Supplying LT line spacer for 4wire ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges et...
Fixing LT line spacer for 4wire ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and equipments and all other incidental charges etc.,...
Supplying and fixing of 200A procelian fuse channel with cut out on existing wooden panel/panel using necessary nuts, bolts and washers ---- With all lead and lift including cost and conveyance of all...
Supplying of Heavy duty Copper terminal Long barrel. 95 sq mm copper terminal, Apprx wt: 58 Gm ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all ma...
Supplying of Heavy duty Copper terminal Long barrel. 240 sq mm copper terminal, Apprx wt: 218 Gm. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all...
Supplying of Heavy duty Copper terminal Long barrel. 300 sq mm copper terminal. ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineries and e...
Supplying of 11 KV 200 Amps single break GOS (Dwg. No. BESCOM/GM/QS&S/23 Dtd 24.11.2018 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineri...
Supplying of 11 KV 400 Amps single break GOS (Dwg. No. BESCOM/GM/QS&S/22 Dtd 24.11.2018 ---- With all lead and lift including cost and conveyance of all materials,labour, hire charges of all machineri...
Fixing of 11 KV GOS single break or double break including wiring on old existing structure (Were only fixing of GOS work is involved ---- With all lead and lift including cost and conveyance of all m...
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
Call3-TN -HT LT -Others.doc
Instructions to Tenderers • 0.15 MB
Call-3 kw3 HT LT Line -Others.docx
Tender Document • 0.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .