Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹9.4 LAccepted-AOC | L-1 | Accepted-AOC Tender accepted due to the lowest tenderer | |
| 2 | L-2₹10.4 L+₹36,595 (3.64%)Rejected-Finance | L-2 | Rejected-Finance Not Being L1 | |
| 3 | L-3₹12.9 L+₹2.8 L (28.0%)Rejected-Finance 93 61 AGARWAL FARM MANSAROVER JAIPUR 302020 | JAIPUR | JAIPUR | RAJASTHAN | 302020 | L-3 | Rejected-Finance Not Being L1 | |
| 4 | L-4₹19.8 L+₹9.8 L (97.0%)Rejected-Finance | L-4 | Rejected-Finance Not Being L1 |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
1 May 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE (I) Niwaru
AGE (I) Niwaru
AGE(I) N-05 OF 2023-24 REPAIR AND MAINT HT CIRCUITS INCLUDING HT SWITCH GEAR AT MUNDOTA AND NIWARU MIL STNUNDER AGE (I) NIWARU
2023_MES_588114_1
AGE (I)/N-05 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE (I) Niwaru
CLASS
6 documents required · 6 mandatory
₹500
Yes
AGE (I) Niwaru
₹30,000
Yes
22 May 2023
3 Apr 2023
3 May 2023
3 Apr 2023
1 May 2023
17 Apr 2023
Amount
S&F in repair of cable end termination jointing kit, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 240/300 Sqmm, 3 core,11 KV grade, Complete all as specified and directed by engineer in charge. NOTE:- Item rate quoted including required T&P. Complete all as specified and directed by Engr-in-charge.
All as per item No. 1 but for HT XLPE cable 95 Sq mm, 3 core,11 KV grade.
All as per item No. 1 but for indoor type, 240/300 Sqmm, 3 core,11 KV grade.
All as per item No. 1 but for indoor type, 95 Sqmm, 3 core,11 KV grade.
S&F in repair of cable straight through jointing kit, heat shrinkable, outdoor type complete with jointing material suitable for HT XLPE cable 240/300 Sqmm, 3 core, 11 KV grade, Complete all as specified and directed by engineer in charge. NOTE:- Item rate quoted including excavating/required T&P/Refixing & Refilling.
All as per item No. 5 but for HT XLPE cable 95 Sq mm, 3 core, 11 KV grade.
Taking shut down and carry out repair to off load rotating type 33KV/ 200 Amp Air break gang operated switch and alignment of isolators, blades, arcing horns moving mechanism oiling greasing to isolators gear box assembly tightening renewal/ replacement of unserviceable spare/components, nut and bolts complete air break switch unit after carrying out fresh lubrication using Lithium base grease/petroleum jelly, and re-fixing the spare parts/components complete all as directed at site, Complete all as specified and directed by engineer in charge. NOTE: New spares/components shall be measured and paid separately as under
(a) Supply only metallic (brass, alloy) fixed contact set, single pole including fixing screwed nuts and washers suitable for air break gang operated switch of capacity 200 Amps, 3 pole, 33000 Volts grade, Complete all as specified and directed by engineer in charge.
(b) Supply only Post insulator with GI post for holding fixed/moving contact assembly including fixing arrangements suitable for Air break gang operated switch 200 Amps, 33000 volts grade, Complete all as specified and directed by engineer in charge.
(c) Supply only GOD operating rod with cover 33000 Volts grade insulation including locking arrangements with 65mm pad lock (Godrej) with two keys, Complete all as specified and directed by engineer-in-charge.
S&F in repair of HT fuse 30 to 200 Amps capacity, Complete all as specified and directed by engineer-in-charge.
S&F in repair of power pack for 33KV and 11 KV Vacuum circuit breaker of incoming 110 volts AC, outgoing 24 Volt DC, Complete all as specified and directed by engineer-in-charge.
M&L for tracing the HT/ UG cable fault with HT cable fault locator of 33 KV/11KV System in any situation/position complete as directed. NOTE:-(i) One Single cable of any length for end to end termination with any number/type of faults will be considered to consitute only one qty for tracing and payment purpose., Complete all as specified and directed by engineer-in-charge.
Supply, laying and commissioning XLPE insulated screened, PVC bedded galvanised steel strip or wire armoured electric power cables (heavy duty) with aluminium conductor 11000 Volts, 95 Sq mm, 3 core cable grade IS-7098 marked, suitable for HT 11 KV (E) System laid in trenches/ ducts/ encased in GI pipe/ fixed to poles including jointing & testing in repair, complete all as specified and directed.
All as per item No. 11 but for 240 Sq mm, 3 core cable.
Supply and fix in repair Plate type cable route indicator shall be made out of 100mmx5mm GI plate welded/bolted on 35mmx35mmx6mm angle iron, 60 Cm long duly inscribed "HT CABLE" on the plate. This plate type marker shall be mounted aong the cable trench at intervals not exceeding 30 meters.angle iron should be fixed on PCC foundation and base of the foundation prepared by aggregate of 20mm dia size of ratio 1:2:4 type B1 and size of the base 150x150x160mm thick all as specified and directed by EIC. (Note:- Item rate quoted includes grouting,excavating/required T&P & Refilling.)
M&L earthing complete as per electrical plate No 3 of MES SSR Part-I with galvanised steel earth plate electrode 60cmx60cmx6.0mm thick, buried directly vertically in ground in a pit depth not less than 2.25 metres below ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level connected to and including galvanised iron or steel earth strip 32mm x 6mm by means of bolts, nuts check nuts and washers of galvanised iron or steel. Earthing strip shall be protected by galvanised iron or steel pipe 40mm bore light grade and connected to continuous earth wire on pole/test point. Watering pipe shall be 20 mm bore GI medium grade. The earthing shall be of inclusive of excavation & earth work in any type of soil, charcoal, salt, funnel PCC pit and RCC cover complete all as specified & tested including taking down of existing earthing, Complete all as specified and directed by engineer-in-charge.
M&L for Dehydration /filtration of transformer oil existing transformer installed at site with portable plant to improve the dielectric strength to 60 KV or above during filling after initial filtration including testing of dielectric strength after dehydration at site. Note- Quoted rates shall be deem to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration plant including transportation complete. (iii) Transformer oil for topping up will be measured and paid in relevant item as required. (iv) Replacement of minor parts like Drain valve,oil seal etc.
S&F in repair of transformer oil in transformer installed/ at site for toping up the level of oil having dielectric strength 40-60 KV.Transformer oil conforming to IS-335 shall be supplied in sealed container , empty barrel of transformer oil will be deposited by contractor in E/M store yard, Complete all as specified and directed by engineer-in-charge.
M&L for testing and checking of di-electric strength of transformer oil with testing equipment/ instruments by maintaining a gap 2.5 mm between electrodes and applying voltage with rate of rise at 2 kV per sec as per indian standards and directed by Engr -incharge .
M&L for rectification of oil leakage from HT side of transformer 11/0.433KV upto 400 KVA by necessary repair/repalcement of bushing/Gasket/seal etc complete with brass terminal including testing complete all as specified and directed by Engineer in charge. Note :- (i) Contractor should make his own arrangement for all necessary T&P & transportation to work shop etc. (ii) Contractor has to rectify the leakage within 8 hrs after opening and dismentelling of transformer for repairing otherwise a penality of Rs 500/- per hrs would be imposed.
All as per item No. 18 above, but for rectification of oil leakage from LT side of transformer 11/0.433KV upto 400 KVA cmplete all as directed.
Supplying and spreading of gravels size 40-63 mm size around transformer plinth, two/ four pole structure and HT yard etc.
S&F of PCC pit and RCC cover for replacement of damaged / broken pit, cover of earthing , Complete all as specified and directed by engineer in charge.
M&L for Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for HT, 25x20cm size fixed in repair, complete all as specified and directed by engineer in charge.
M&L for Lightning arresters expulsion type for 33 KV complete with all fittings, transmission class, discharge capacity 65 kilo amp fixed in repair,, Complete all as specified and directed by engineer in charge.
M&L for Lightning arresters expulsion type for 11 KV complete with all fittings, transmission class, discharge capacity 65 kilo amp fixed in repair, complete all as specified and directed by engineer in charge.
M&L for Triple pole Switch air brake, Gang operated, mechanically operated, mounted on insulator and steel frame, with operating mechanism worked from ground level, for 11 kV ¤t rating upto 200 amps fixed in repair,complete all as specified and directed by engineer in charge.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for foundation etc or for shafts, wells, cess pits, manholes, pier holes, laying cables erection of poles / struts/stays etc not exceeding 10 Sqm on plan, not exceeding 1.5 metre in depth and getting out in any type of soil complete all as specified and directed.
Removing of excavated material (soil) to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.50metre above the starting point complete all as specified and directed
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm in any type of soil complete all as specified and directed.
M&L for sand cushioning to PVC underground cable with crush stone sand and punning down to provide a required cusion to complete all as specified and directed. Note:- Punned thickness shall be considered for payment purpose
Supplying and laying factory made un-reinforced PCC precast cable covers class HV, type I, peak, size 300mm x 180mm x 40mm complete all as specified and directed.
Laying only Bricks for protection cover to under ground cable (retrieved undamaged old sub clas 'B' bricks during excavation for laying of cable), complete all as specified and directed.
SHREE BHAGWATI ENTERPRISES
M/S Anil Enterprises
R K ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .