COL BHUPINDER SINGH CWE NAVY VASCO
CWE NAVY VASCO VASCO DA GAMA GOA 403802
REPAIR MAINTENANCE OF HT NETWORK INCLUDING VCB TRANSFORMERS AND OTHER CONNECTED WORKS AT INS MANDOVI
2022_MES_572272_2
85635/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
GE (P) NAVY MANDOVI
₹40,000
Yes
1 Apr 2023
11 Feb 2023
11 Mar 2023
11 Feb 2023
9 Mar 2023
18 Feb 2023
Amount
M&L for Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for laying & removing of cable any sizes and getting out in soft disintegreted rock/ laterite rock complete all as specified and as directed.
M&L for Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata complete all as specified and as directed.
Removing excavated disintegarted rock soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point complete all as specified and as directed.
Supply/ Lay dry river sand /m -sand in trenches for cable protection complete all as specified and as directed. Note : Punned thickness only will be measured & Paid
Supply and lay un-reinforced precast concrete ISI marked cable covers, class HVP , type- I with peak, size 300mm x 180mm x 40mm, all as specified and directed.
Supply and fix in trench/on wall in repairs GI tubing light grade for road crossing and cable protevtion of the following sizes complete all as specified and as directed.
(a) 80 mm dia
(b) 100 mm dia
M & L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate including use and waste of form work of concrete for pole and stay foundation complete all as specified and as directed.
M & L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate including use and waste of form work for pole coping/ any description complete all as specified and as directed.
Earthing complete with galvanised steel earth plate electrode of size 60cm x 60cm x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground ( earthpit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth lead by means of bolts , nuts check nuts and washers of galnanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electric plate No -5 of SSR- Part-1 connected to earth test point all as specifed or indicated including testing on completion and necessary excavation and earth work in soft/loose soil, returning filling, disposal of surplus soil, earth pit in PCC 1 :3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 15 mm diia meduim grade watering pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer complete all as specified and directed
S & F in repairs Galvanaised Iron cross arms channel, bracing, support, clamps etc fabricated structured steel, sections, including nuts, bolts, washers etc and cutting to required length beat to any shape drilling holes, fixed on poles or jointed by means of elect welding complete incl painting with 2 coats of aluminum paint over a coat of red oxide primer after preparation of surfaces incl taking down / dismantling the old items complete all as specified and as directed.
Dismantling of existing old unserviceable earth wire and gradle guard of any size form the position, material and labour for providing new GI wire 4 mm dia (8 SWG) on poles to continuous earth wire and cradle guard etc, complete all as specified and as directed.
Dismantling old unserviceable stay assy complete, material and labour for new stay assembly complete with 20 mm dia stay rod with accessories shown in electric plate No 01 incl stay clamp, (loop insulator, stay wire, excavation and concrete measured seperately) complete all as specified and as directed.
M & L in repairs for Galvanised Stay wire of size 7/4 mm incl dismantling old wire complete all as specified and as directed.
S & F in repairs for loop insulator Vitreous Porcelian white or brown of size 90 X 140 mm clearance hole 25.5 mm complete all as specified and as directed.
S & F in repairs Disc type porcelain vitreous, brown or white insulator suitable for 11 KV HT working Pressure of size 145 mm height, 255 mm dia , including. one galvanised mild steel spindle, two galvanised iron washer and one GI nut complete all as specified and as directed.
S & F in repairs Pin type porcelain vitreous,brown of white insulator suitable for 11 KV HT of working pressure of size 150mm height, 150mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete all as specified and as directed.
S & F in repairs Pin type porcelain vitreous,brown of white insulator to suit 1100 Volt working pressure of size 100 mm height, 65mm dia, including one galvanised mild steel spindle, two galvanished iron washer and one GI nut complete complete all as specified and as directed.
S & F in repairs shackle type porcelain vitreous brown or white 1100 Volt of size, 115 mm dia and 100mm height including GI strap of size of 31 x 5 mm insulator bolt of 14 mm dia, nuts and washers for working pressure 1100 V complete all as specified and as directed.
S & F in repairs incl testing of swing out explusion fuse isolated assembly with fuse carrier out door type 11 KV supply 200 Amp ( DO Fuse ) all as directed.
S & F transmission class type drop out fuses 11000 volts rating 25-50 amps,outdoor type complete.
Supply & Replacement of switch air break gang operated out door type (conforming to IS specifications) 11 KV, 200 Amps capacity triple pole mechanically operated suitable for operation from ground level and for vertical mounting complete with HT insulator 12 Nos, channel, GI pipe light grade/ operating rod with pad lock arrangement and out door drop-out expulsion fuse assembly with fuse carrier fitting all as specified and directed .
S & F in repairs lightning arresters expulsion type complete with all fittings transmission class, discharge capacity 65 kilo amps, suitable for 11 KV all as direcetd.
Supply and fix cable jointing kit for 11KV grade cable for Outdoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size upto 120 sqmm complete all as specified and as directed.
Supply and fix cable jointing kit for 11KV grade cable for Indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 50 to 95 sqmm complete all as specified and as directed.
Supply & Laying in replacement , testing and commissioning XLPE cable , PVC insulated, screened PVC bedded galvanised steel strip or wire armoured electric power cable, heavy duty with aluminium conductor 11000 Volts grade (earthed), 3 core 95 sqmm laid in trenches / floor / duct / fixed on poles / through GI tubing in different locations / areas including taking out old HT cable complete all as specified and as directed. Note:- Contractor will deposit the old unsv retrieved HT XLPE Cable to MES Store Yard.
S & F in repairs post insulator suitable for 11 KV HT working pressure in GOD / DO arrangements of any description all as directed.
Repairing / Servicing the Air break isolating switch HT 11 KV 200/400 Amps by replacing the defective major spares including provn of minor bolts nuts etc all as specified. Note :- Major spare will be measured & priced seperately under relevant item of Sch'A' item No. 28
Supply only 11 KV Airbreak switch spares complete all as specified and as directed.
(a) Male contact/moving Contact Blade
(b) Female contact/Fix Contact Jaw
(c) Tinned copper Flexible jumper 200A/400 A
(d) MS jumper carrier
(e) Back Connector plate
(f) Petroleum Jelly
Supply only All aluminium conductor for binding purpose of not less than 0.9mm dia for tightening the conductors on poles complete all as direcetd.
Taking out / Draining out of any condition of insulating oil from transformers of any size/ type/capacity carefully and kept fully secured in seal tight containers or dehydration & filteration process to be carried out in transformer directly through dehdration machine complete all as specified and as directed.
Draining out existing transformer oil from transformer and after draining out the oil, flush out the bottom of the transformer with fresh transformer oil and after flushing out of bottom supplying and filling new transformer oil EHV grade after filtration attains BDV upto 50 KV for transformer 11 KV/433 V complete all as specified and as directed.
M & L for PVC sleeves suitable for LT / HT ACSR conductor / jumper in any type in R Y B Colours superior quality inserted over the ACSR complete all as specified and as directed..
M & L for preparation of old cement coated surface, cleaning the surface of the RCC pole (HT) 11 Mtr long in 1 / 2 / 4 pole structures above the ground level incl coping area with 2 coats of ACC exterior Emulsion paint over a coat of cement primer after preparation of surface including 12 cm black paint around the pole numbers/letters in white columns all as directed.
S & F in replacement Breather unit with superior quality blue colour silica jel, to maintain the exact value of grade for transformer of capacity 100 KVA to 150 KVA, including taking down unserviceable complete all as specified.
All as per item No 34 above but 200 KVA to 250 KVA Transformer
All as per item No 34 above but 315 to 400 KVA Transformer
S & F in repairs HV insulator with studs nut & washers suitable for 11 KV/433V HV side of transformer 100 KVA to 150 KVA complete all as specified and as directed.
All as per item No 37 above but 200 KVA to 250 KVA Transformer
All as per item No 37 above but 315 to 400 KVA Transformer
S&F in repairs LV insulator with studs nut & washers suitable for11 KV/433V LV side of transformer of Capacity 100 KVA to 150 KVA
All as per item No 40 above but 200 KVA to 250 KVA Transformer
All as per item No 40 above but 315 to 400 KVA Transformer
Supply and fill new silica jel, superior quality in the breather unit of transformer incl taking out the old unserviceable one all as directed
Taking out the existing serviceable Post / disc / pin insulator of 11 KV capacity carefully and re-fixing the same in the new cross arms / structure incl replacement of new hardware such as GI spindle, nut, bolt and washers complete all as directed
Taking out the old HT 11 KV UG serviceable cable of 3 core 95 Sq mm from trenches / floors/ walls and relaying / diversion / jointing the same in the same trenches as directed and connecting all as directed Note: Earth work is deemed to included in quoted rates
M&Lfor anti-climbing device; spike type fabricated out of MS bar ( round'squar and flat) including nuts, bolts, washers and welding in two halves made to shape to suit the cross section of the pole HT/LT
M&L for Danger notice plate of 1.6mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts of approved size for HT,25X20X20mm size
S & F in repairs HT bushing 11 KV porcelain insulator for transformer capacity upto 100 to 150 KVA
All as per Item No. 48 above, but transformer cap 200 to 250 KVA
All as per Item No. 48 above, but transformer cap 315 to 400 KVA
S & F in repairs LT bushing porcelain insulator in transformer 11KV/440V Cap upto 100 to 150 KVA
All as per item No.51 above but transformer cap 200 KVA to 250 KVA
All as per item No.51 above but transformer cap 315 KVA to 400 KVA
S & F in repairs brass studs with nuts,washers for HT bushing for 11 KV transformer upto 100 to 250 KVA Capacity
All as per item No.54 above but from 315 KVA to 400 KVA
S & F in repairs brass studs with nuts,washer for LT bushing for 11KV/440 V transformer Cap upto 100 to 250 KVA
All as per item No.56 above but for transformer Capacity 315 KVA to 400 KVA
M&L for Minor welding work/patch work for any type and any capacity of transformer including drain out and refilling oil,and painting with two coats of synthetic enamel paint to all surfaces of the transformer over a coat of primer to welding/patch work portions for transformer of capacity upto 400 KVA
M & L for painting of transformer outside of body completely, including cleaning the body scrubbing thoroughly and applying one coat of synthetic enamel existing shade of paint to transformer of capacity upto 400 KVA
M&L for dismantling of U/S capacitor bank any type and capacity from any site after disconnecting electric connections and depositing at MES store Yard incl removal from site and making good of disturbed surface all as directed at site.
M & L for fixing of lugs (3 P + N) on LT cable to connecting on LT side bushing by removing old lugs fixed on LT busing complete for 300 to 400 Sqmm 3.5 core cable.
Supply and fixing in repair Temp guage 0-300 degree centigrade Make WIKA
M & L for graded coarse aggregate (broken stone or boulders) of size 12.5 mm in sub - station yard/GOD/ Sub Stn for laying all as directed and specified.
M & L for Opening up the top cover of transformer and Disconnecting HT/LT connections of burnt/defective copper/aluminium wound transformer 11/0.433 KV of capacity up to 400 KVA incl taking down from site of installation with the help of crane and shifting the transformer to trade/contractor's workshop for repair, re-installing (after carrying out repair), testing and commissioning the transformers at site on full load complete all as specified and directed. Note:- 1. T & P required for taking down & transportation of transformer at site & workshop deemed to be included in rate quoted. 2. Repair to transformer shall be measured and paid for separately under respective items here-in-after.
M & L for Rewinding of unserviceable HT/ LT winding with ISI marked new double paper covered copper wire/strip wound coils of capacity up to 400 KVA transformer with suitable size/gauge to match with existing working capacity of the transformer and all as per manufactures design/specifications including provision of Class 'E' insulation and fixing the coils in core assembly complete all as specified and directed.
Supply & Replacement of cork sheet gasket 6 mm thick superior quality on top cover plate of the transformer capacity 100 to 400 KVA Transformers
Supply & Replacement of LT bush assembly brass complete with double check nuts, washers E and oil seal all accessories with bushing insulators suitable for transformer capacity 100 KVA to 160 KVA
Supply & Replacement of LT bush assembly brass complete with check nuts, washers oil seal etc all accessories with bushing insulators for transformer capacity 200 KVA to 400 KVA
Supply & Replacement of HT bush assembly brass complete with double check nuts, washers and oil seal all accessories without bushing insulators for transformer capacity 100 KVA to 160 KVA
All as per description of serial item No 69 here-in-before but capacity 200 KVA to 400 KVA complete all as specified and directed.
Repair to operating mechanism of 11 KV air break gang operating capacity 200/400 Amps with necessary oiling/greasing to moving parts and to set right the alignment of Male/Female contact for proper contact etc all as directed
S&F synthetic hight voltage insulating matsuitable for 3.3 KV to 11 KV grade used in electricial distribution panel/floor/VCB/ACB operation as per IS specification 15652/2006 of size 1m x 2m x 2.5mm or all as specified and directed by Engr in Charge
M & L for cutting the grass & trimming of bushes around the GOD, two pole structure, Four pole structure etc removing the retrieved material out of MoD land all as directed
Servicing and repairing/carrying out for maintenance of 11 KV/440V transformer including the following works for transformer upto 400 KVA capacity as details here under including the following complete all as specified and directed by Engr in Charge:- (a) Removing from platform and disconnecting electrical connection from HT and LT side including transporting the transformer to workshop including loading and unloading complete or to be repaired at site as per requirement. (b) Dismantling the transformer, drain out transformer oil, lift the top coper by opening all nuts, bolts with the help of T&P Chain pully , tepoy at site or in workshop as required for carrying out the following repair/replacement works :-
(i) Replacing HV/LV insulator with studs nuts & washers (ii) Replacing HT & LT side bushing porcelain insulator (iii) Brass studs with nuts and washer of HT or LT bushing (iv) For detection of fault inside the transformer in concern to winding defect, any short etc and intimation to JE/ Engr in Charge for further direction. (c) Re-assembling all dismantled parts including porvision of new gaskets, nuts, bolts washers etc , refilling with drained out transformer oil and transporting back to original location including electrical connection, testing and commissioning all as directed Notes : (a) Oil filteration, supply of new oil will be measured and paid separately. (b) All petty parts including nuts, bolts, gasket, minor welding, oil for cleaning, greasing etc any other minor works and material (other than listed separately) required for reassembling all dismantled parts are deemed to be included in the rates. (c) The rates for transport and lifting of transformer by Crane shall be deemed to be included in this rates.
M & L for repair/maint/ servicing of VCB 11 KVA 630 Amps of Make KIRLOSKAR , by expert service engineer from auth firms which includes removal of VCB trolley,cleaning of all copper male & female contacts,applying anti corresive jelly,tightning of all connections ,refixing the VCB trolley to its original position Checking manual/motorise operation of VCB,checking tripping systems, taking out burnt control wiring and rewiring the same with existing size of conductor/wire including internal cleaning, ,tightning of all connections etc complete all as specified and directed.
S&F in replacement of following spares of VCB while servicing,maint vide Item No 63 above :-
HRC fuse base with HRC fuse 16 Amp
Limit switch for spring charging motor
Micro switch for spring charging motor
11 KV bus bar insulator
Spout bushing (set of 3)
Bakellite sheet
LED indicator
TNC switch
Closing coil 24 VDC
Triping coil 24 VDC
Space heater 100 watt 220 VAC
Fix Contact (set of 6)
Big Gear
Small Gear
Segmented Gear
Spring charging motor
Shree Ram Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .