Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹6.8 CrAccepted-AOC 14 CHAHAR CONSTRUCTION CO ADARSH NAGAR NEAR ROHILLA COMMUNICAION 124103 | JHAJJAR | HARYANA | 124103 | ₹6.8 Cr Quoted ₹5.6 Cr | L-1 | Accepted-AOC ok |
| 2 | L-2₹5.6 Cr+₹5.1 L (0.92%)Rejected-AOC DHANI CHANDPUR BAWAL ROAD REWARI DHANI CHANDPUR BAWAL ROAD REWARI 123401 | REWARI | REWARI | HARYANA | 123401 | ₹5.6 Cr+₹5.1 L (0.92%) | L-2 | Rejected-AOC ok |
| 3 | Not Admitted-Fee/PreQual/Technical JUI ROAD VILLAGE DULHERI TEHSIL TOSHAM DISTT BHIWANI 127040 | BHIWANI | BHIWANI | HARYANA | 127040 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 4 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
| 5 | Not Admitted-Fee/PreQual/Technical N H NO 6 BAMBHORI JALGAON MAHARASHTRA 425001 | JALGAON | MAHARASHTRA | 425001 | - | - | Not Admitted-Fee/PreQual/Technical Not Complied with technical specification |
Tender Value
₹6.3 Cr
EMD Value
₹12.6 L
Closing Date
23 Aug 2024, 2:00 pmClosed
SONIT RAHTEE RAHTEE
MICAD Divsion Mahendergarh
Micro Irrigation Infrastructure on Reservoirs of Village Bigopur , Dochana , Koriwas , Nayan and Dhanota
2024_HBC_399034_1
2024DD8B4A26 296C 4800 9831 CC62DC64EB151865CAD
Open Tender
Civil Works
Works
365 days
BIGOPUR DOCHANA KORIAWAS NAYAN DHANOTA
Micro Irrigation Infrastructure on Reservoirs of Village Bigopur , Dochana , Koriwas , Nayan and Dhanota
3 documents required · 3 mandatory
₹20,000
₹12.6 L
Yes
Executive Engineer, MICAD Elect. Divn Mahendergarh
29 Nov 2024
10 Aug 2024
23 Aug 2024
10 Aug 2024
23 Aug 2024
10 Aug 2024
21 Aug 2024
Amount
Galvanizes steel chain link both end twisted fence fabric having opening size 7.5x7.5 cm and 3.15 mm dia wire, 2.2 meter height of mesh, with 2.8 meter ht of MS Angle 50x50x5 mm supports fixing at spacing of 3 meter centre to centre, supports with MS Flat 35x5 mm. Fencing supported with MS Angle 35x35x5 at top and bottom. The M.S Angle supports shall be anchored in cement concrete (1:3:6) blocks 45x45x60 cm additional razor barbed wire fencing shall be provided at the top of mesh, fencing including gate
Horizontal directional drilling with micro tunnelling methods, for pipe laying under pucca rasta /road crossing( Rates approved ni TAC,MICADA Haryana meeting on 09.02.2022)
Providing, fixing, testing and commissioning of pressure gauge 2` dial with Glycerin filled to be fixed before and after filtration unit (Rates approved in TAC,MICADA Haryana meeting on 09.02.2022)
Providing and fixing 12 Watt LED Street Lighting of 75 watt solar panel, 12.8 volt 30 Ah Lithium Ferro Phosphate battery, 12 Watt White LED Luminaire and Pole of 5 Meter above ground level with dusk to dawn operation {first 4 hours full light Systemding , fixing and testing of Solar light including battery: min. 24 lux) , rest of the time at lower light (50% Min. 12 lux) level} and 3 days or minimum 36 operating hours autonomy or as per direction of engineer-in-charge (As per rates approved by HAREDA)
Hydrant assembly for Nakka in field, Rates including Tee, riser pipe, butterfly valve, Flange and labour for fixing butter fly valve should be as per IS 13095-2020
Providing fixing of Header Assembly/Manifold 3’ Rates approved vide memo No.MICADA/2021/3068- 70 dated 07.06.2021
Providing and lowering of HDPE floater manufactured with 225 mm dia PE pipe having PE-80 and PN-10 to float the submersible open well pump/motor
roviding and fixing Tank Type (Make of Metal) Fertilizer and Chemical Injector System confirming to IS 14483 (Part 3) of 2018 for demonstration and guiding the farmers regarding fertilization and chemicalisation of system. (rates include ventury with manifold 1.0`=1300 and 60 liter fertilizer tank= 4400) Rates approved vide memo No.MICADA/2021/3068-70 dated 07.06.2021
NS Item -Preparation and implementation of warabandi of the complete chak and Identification of training needs of the farmers, preparation of training modules on various subjects concerning operation and maintenance of the MI systems, Solar array and pumping systems and cropping pattern etc., and providing necessary training to the farmers as per the identified needs including operation maintenance , watch and ward up to 04 years. Necessary training shall be provided to the WUA members and the staff identified by the Engineer also for all activities involved in the O and M Note :- The work will be considered completed after successful completion of entire project exclusive of training and O and M of work. 10% security will be deducted in each bill of the work, which will be released after completion of work on the production of Bank Guarantee of same value , out of which 2% will be released annually after successful running and annual maintenance of the system, on the production of satisfaction certificate by concerned Executive Engineer .
Supply Installation testing commissioning of Solar Photovoltaic Stand alone Plant conforming to MNRE specifications as amended, consisting of Mono Crystalline silicon solar cells, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength, anti-theft screws. Including lightning and surge voltage protection, Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required, built in metering system to monitor plant performance (Amp-meter, Volt-meter, Frequency meter, Energy meter, Watt-meter, and other instrument/equipment as required) Note:- PV modules used must qualify to the latest edition of IEC PV module qualification test or equivalent BIS standards Mono Crystalline Silicon Solar Cell Modules IEC 61215/IS14286. In addition, the modules must conform to IEC 61730 Part-1- requirements for construction and Part 2 – requirements for testing, for safety qualification or equivalent IS and be mounted on fixed Aluminium/GI structure of adequate strength and design as per IEC/IS specification. Including field-based electroluminescence (EL) study be performed after receiving the modules at site and after installation. Module mounting structure (MMS) including suitable foundation, design and drawing shall be duly vetted from government institute Including third party inspection. Solar plant complete in all respect
Supplying, erection, testing and commissioning of Variable Frequency (VFD Drive ) complete with all accessories for the required power capacity of Solar Pump. VFD Drive for Pump set of power capacity 20 HP
NS Item -Survey, planning, design, drawing and hydro analysis of the complete piping system, pumping units and solar plant to check adequacy of the complete MI infrastructure and vetting it from the Government institute to the satisfaction of Engineer Incharge in hard copy as well as in digital format, as estimated quantities are based on the tentative design parameters.
Supplying, erection, testing and commissioning of Solar AC Openwell Submersible Pump Set of 20 HP with three phase motor having casing of Alloy Steel for the required power capacity, discharge and Head including all PVC insulated polymer sheathed 3 core flat type cabling in conduit, required from solar plant to solar pump through control room
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISi marked HDPE pipe of PE-80 grade, SDR-17 and PN - 6 for Irrigation as per IS 4984 : 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. 140 mm dia HDPE Pipe
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISi marked HDPE pipe of PE-80 grade, SDR-17 and PN - 6 for Irrigation as per IS 4984 : 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. 110 mm dia HDPE Pipe.
NS Item -Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISI marked HDPE pipe of PE-80 grade, SDR-26 and PN - 4 for Irrigation as per IS 4984 : 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer.Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. 110 mm HDPE Pipe
Providing, lowering, laying, aligning, fixing in position and jointing at all level/ depths ISi marked HDPE pipe of PE-80 grade, SDR-26 and PN - 4 for Irrigation as per IS 4984 : 2016 (amended up to date) in trenches in complete including cost of HDPE Specials, labour, sectional hydro testing (including the cost and conveyance of water to site for testing) and commissioning as per Technical Specifications and as per direction of Engineer. Rate includes cost of all specials like bends , tees required during laying of pipe line along required alignment. 140 mm dia HDPE pipe
Construction of 8` x 10` control room constructed with 9` thick brick masonry inner side covered with 6’ thick RCC slab in 1:1.5:3 concrete slab of size 9.5’x12` mix with proper door and 2 No. windows and electric installation as per approved design and drawing inner size 8 x 10 and Height 9` from DPC level complete in all respects
Bidder Name
Amount
Chahar Construction Co (GSTN-06AAMFC2979A1ZI) BID ID -1146924
Rakesh Yadav Contractor (GSTN-NA) BID ID -1145501
Rakesh Yadav Contractor (BID ID -1145501)
Rakesh Yadav Contractor (BID ID -1145501)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .