Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.4 LAccepted-AOC 0 KALAMBAGH CHOWK MUZAFFARPUR BIHAR 842002 UDYAM BR 23 0013096 | MUZAFFARPUR | BIHAR | 842002 | 1 | Accepted-AOC 1 | |
| 2 | 2₹4.5 L+₹5,044 (1.15%)Rejected-Finance H 50 C SHAKARPUR DELHI 110092 | SHAHDARA | DELHI | 110092 | 2 | Rejected-Finance 2 | |
| 3 | 3₹4.7 L+₹27,626 (6.28%)Rejected-Finance | 3 | Rejected-Finance 3 | |
| 4 | 4₹4.7 L+₹33,323 (7.57%)Rejected-Finance R 40 VIKAS MARG SAKAR PUR DELHI 92 | 4 | Rejected-Finance 4 |
Tender Value
₹4.6 L
EMD Value
₹9,508
Closing Date
27 Jun 2023, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EEE-III/RZ
EEE-III/RZ
Improvement of lighting arrangement in various Mpl parks and locations of village Mubarakpur and other area of ward no-39 under Rohini zone
2023_NDMC_158213_1
EEE-III/RZ/TC/2023-24/02.2
Open Tender
Electrical Works
Item Rate
120 days
EEE-III/RZ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
₹9,508
16 May 2025
21 Jun 2023
28 Jun 2023
21 Jun 2023
27 Jun 2023
21 Jun 2023
Amount
7.1.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
2.10.1:Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.2:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
1.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
14.15.1:Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required.63 mm· dia (OD-63 mm & ID-51 mm nominal)
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.15:Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
122.1.3:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*10 sqmm
122.1.36:Supply of XLPE insulated PVC sheathed Al. Conductor Un-Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.1.43:Supply of 17/18 Watt LED retrofit lamp suitable for B22 holder
122.2.2: P/F Hot press sheet moulded compound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof pole box of inner dimension 200x160x98mm (NS) complete with suitable arrangement for fixing of 2 nos of 6 to 32 amp single pole MCB & 63 Amp. Double pole isolator (MCB/Isolator excluded) with neutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plate of suitable size with danger monogram property printed on the cover etc as reqd. as reqd.
122.2.17:Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 250mm long 32 mm dia galvanised pipes with tightening bolts complete as required.
122.2.21:SITC of 25 watt LED IP65 post top fitting made of die cast aluminium spigot spun aluminium powder coated top cover and clear acrylic diffuser with high voltage protection low power LED's connected in series and parallel combination with better heat sink arrangement input voltage 160-260 volts AC, 50 Hz AC Supply power factor >0.95, luminious efficacy >100 lumens/watt, CCT 5700°K ±300°K, Surge protection not less than 10KV complete etc as requred.
122.2.24:Providing and laying of HDPE PIPE OF 40mm outer dia with PN 4 rating by hand Moling/Mannual method Confirming to IS 4984 592
122.2.30.a:SITC of 150W LED Flood Light luminaire fitted with lens, made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =150 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.33:SITC of 60W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =60 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
OD2227/2023-2024:Supplying and fixing of 32 mm dia X 1.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 25mm X 6 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required
OD2230/2023-2024:Providing & laying in position 1:2:4 grade reinforced a cement concrete foundation of size suitable RCC(1:2:4) shallow foundation of size 1m(L) X 2m deep i/c excavation of earth providing cutting bending and placing in position reinforcement of cold twisted bar of 12 mm -2100 long(approx) -16 nos and reinforcement of cold twisted bar of 8 mm-3700 mm (approx)- 13 nos (with 150 mm spacing) as required with Positioning of foundation bolts and providing DWC HDPE pipe for cable entry & exit as required for the high mast Considering the safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material plate as reqd suitable for 12 meter poles.
OD2231/2023-2024:Dismantling/removing transportation and Erection of 12 mtr semi high mast pole by maintaining proper safety rules after removing the base ,stacking the poles at proper place and refilling the pit with loose earth and remaining all removal of malba by maintaining proper safety i.e use rope and crane while shifting the pole.
Iluminators And Circuiteers
Kamal Electricals
VISHU ELECTRICALS
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .