Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹25.3 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹27.4 L+₹89,577 (3.38%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder | |
| 3 | L3₹28.8 L+₹2.3 L (8.75%)Rejected-Finance 61 ABHAY GARH SCHEME AIR FORCE JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | L3 | Rejected-Finance Not Lowest Bidder | |
| 4 | L4₹29.1 L+₹2.6 L (9.97%)Rejected-Finance 40 VISHNU VIHAR KHERAI SHAMSHABAD ROAD KHERAI AGRA UTTAR PRADESH 282001 | AGRA | UTTAR PRADESH | 282001 | L4 | Rejected-Finance Not Lowest Bidder | |
| 5 | L5₹29.2 L+₹2.7 L (10.4%)Rejected-Finance 5 L LEHAL COLONY PATIALA 147001 | PATIALA | PATIALA | PUNJAB | 147001 | L5 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹29.3 L
EMD Value
₹58,500
Closing Date
23 Mar 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Jaisalmer
GE (AF) Jaisalmer
REPAIR /REPLACEMENT TO MISC E/M SERVICES AND ALLIED WORK AT GCA AND CERTAIN BPs AT AF STN JAISALMER
2023_MES_582481_1
8886/GE/E8
Open Tender
Miscellaneous Works
Item Rate
270 days
GE (AF) Jaisalmer
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE (AF) Jaisalmer
₹58,500
Yes
28 Mar 2023
23 Feb 2023
25 Mar 2023
23 Feb 2023
23 Mar 2023
9 Mar 2023
24 Feb 2023 - 27 Feb 2023
Amount
Taking down carefully existing unserviceable/perished conduit/ batten/ casing caping aluminium/copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/ conduit/casing caping, switches, sockets, ceiling rose, pendent holder, lamp holders, bracket holders, light fittings, top sheet covers, fan regulators etc and making good the disturbed surfaces of wall/ceiling complete all as specified & directed.
Surface point wiring for one light point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor Flame Retardant Low Smoke & Halogen (FRLSH) cable 1100 Volt grade as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non metalic rigid PVC conduit 20mm dia with accessories fixed to cutting chases in walls by cutter and making good the surface in cement and sand mortar 1:3 and to the original specification and PVC conduit on ceiling for steel structure/surfaces conduit with clamps, gutties etc for RCC ceiling with including cast iron/pressed steel/wooden terminal boxes (as per site requirement) including providing new 3 mm thick plastic laminated sheet cover (Hylem) complete all as specified and directed.
All as per serial item No. 2.00 here-in-before but for one 3 Pin, 5/6 Amps, socket outlet controlled by one 5/6 Amps switch on independent board complete all as specified and directed.
All as per SI No 2.00 here-in-before but 3 pin socket outlet 5/6 Amp on the same board with other switches complete all as specified and directed .
All as per SI No 2.00 here-in-before but with multi stranded copper conductor FRLS-H cable, 1100 volts grade (ISI marked), PVC insulated and unsheathed of size 2.5 Sqmm single core and with and including 2.5 Sqmm PVC insulated unsheathed single core copper conductor cable as earth continuity conductor to common earth and earth dolly for one 15 Amp and 5 Amp socket outlet point on the independent board with terminal box of size 175 mm x 100 mm x 3.15 mm complete all as specified and directed .
Switch piano, flush type, Single Pole, one way, 5/6 Amp, 240 Volts (ISI Marked) complete all as specified and directed.
Switch piano, flush type, Single Pole, one way, 15 Amp, 240 Volts (ISI Marked) complete all as specified and directed.
Socket outlet , 2 in 1, 3 pin, 5 Amps, multipurpose ,flush type, 240 Volts (ISI Marked) complete all as specified and directed.
Socket outlet , 2 in 1, 3 pin,15 Amps, multipurpose ,flush type, 240 Volts (ISI Marked) complete all as specified and directed.
Ceiling rose surface bakelite with two or three terminal PVC /Polycarbonate, isolated body (ISI Marked), 240 volts in repair complete all as specified and directed.
LED integrated batten fitting,20W, four feet , 230V surface mounted on PVC square box with all necessary fixing arrangement etc, complete with 20W LED tube rod with all accessories pre-wired including connecting up with twin core twisted flexible copper conductor cable of suitable size including taking down old unserviceble LED fittings complete all as specified and directed.
Supply and fixing cygnus series Recess mounting LED 36 watt 2' x 2' LED Slim Panel - 595x595 mm white powder coated aluminium extruded housing with LEDs including LED driver and fixing in recess ceiling suitable size of aluminium strip size as required for fixing of LED fitting complete with all accessories prewired fixed on ceiling and connecting up complete with 3 core flexible cable of size 23 / 0.0076 including taking down existing complete all as specified and directed.
Sheet metal enclosure powder coated single phase DB SPN 8 ways and neutral 240 Volts, AC supply, 50 Hz, with 200 Amps rated bus bar Double Door (IP-43 IK 09 with metal door) suitable for fixing of MCBs including fixing of lugs in main incomming and outgoing line and fixing of cable glands of suitable size including grouting flush in the wall by means of nuts, bolts, angle iron and making good disturbed surfaces including taking down old unserviceable DB complete all as specified and directed.
Supply and fixing flush mounting factory made sheet metal enclosure for VTPN DB 4 way, 415 Volt, Double door, IP-43 protection, IK-09, No. of modules (8+20) with metal door with 200 Amps copper bus bar, with neutral bar, earth bar and cables ties for cable management fully insulated bus bar including taking down existing complete all as specified and directed .
MCB, Single Pole, 6 to 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles including taking down existing complete all as specified & directed.
MCB, SPN, 32 Amps rating, with over load and short circuit protection 'C' curve and rupturing capacity 10 kA, 240 Volt grade, AC supply, 50 Hz and making connections using suitable size copper lugs/thimbles, including disconnecting & taking down old unserviceable MCB, complete all as specified & directed.
MCCB, 4 Pole, 100 Amps rating, rupturing capacity 16 kA, 415 Volt grade, AC supply, 50 Hz, thermal Magnetic protection unit and making connections using suitable size copper lugs/thimbles and crimping tool, including disconnecting & taking down old unserviceable MCCB, complete all as specified & directed.
Sub main wiring with 2 run of single core 4.0 Sqmm multi-stranded copper conductor 1100 volts grade heavy duty FRLS-H PVC insulated unsheathed cable drawn through and including non metalic PVC conduit medium grade of suitable size on wall surface conduit including 4.0 Sqmm PVC insulated unsheathed single core copper conductor earth wire including taking down old unserviceable submain wiring complete all as specified. Note : Two run of 4.00 sqmm cable and one run of 4.00 sqmm cable as earth wire continuity conductor and PVC conduit shall be measured & paid as one unit.
Sub main wiring with 4 run of single core 6.0 Sqmm multi-stranded copper conductor 1100 volts grade heavy duty FRLS-H PVC insulated unsheathed cable drawn through and including non metalic PVC conduit medium grade of suitable size on wall surface conduit including 6.0 Sqmm PVC insulated unsheathed single core copper conductor earth wire including taking down old unserviceable submain wiring complete all as specified. Note : Four run of 6.00 sqmm cable and one run of 6.00 sqmm cable as earth wire continuity conductor and PVC conduit shall be measured & paid as one unit.
Supply and fixing in wall/on wall with necessary fixing material sheet metal enclosures with socket plug top tripple pole and earth enclosure with a three pin and earth plug with socket complete with one triple pole MCB 63 Ams, 415 volts and TPN MCB complete including taking down of old nserviceable complete all as specified and directed.
Single pole and neutral enclosure with a two pin and earth plug and socket , 20 Amps 230 Volts with & including one MCB SP ‘C’ Curve 10 kA 20 Amps including taking down old unserviceable complete all as specified and directed.
LED flood lights not less than 150 watts, nominal voltage 240 volts, 50 Hz, high efficiency long life LED module with SMD LED package mounted on MCPCB, lumen efficacy of LED shall not be less than 150 lumen/W, Colour temp (CCT) -5700K and viewing angle of 120 degree to ensure better uniformity, epoxy powder coated pressure die cast aluminium housing elegantly designed heat sink for efficient thermal management, high quality toughened glass IK 07 fixed to housing, having electronic driver, integral, isolated electronic driver with lower THD, output open/short circuit protection, over voltage protection, surge voltage protection with external SPD not less than 10 KV and other safety test as per IS 15885 Part-2/Sec 13, having adjustable MS cradle of thickness 5mm provided in and including taking down of existing lights of any type complete all as specified and directed.
Earthing complete with galvanished earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of plate not less than 1.5 deep below normal ground level and connected to galvanished iron earth lead strip 32mmx6mm upto 7.50 metre, by means of GI nuts, bolt, check nuts, washers, thimbles, etc as shown in electrical plate No. 5 SSR Part-I and connection to main switch board or panel and testing on completion including excavation and earth work in any type to soil, returning fitting in and removal of surface spoil to a distance not exceeding 50 metre, PCC chamber (1:2:4) type B-1, charcoal and salt mixed layer 15cm thick all around the earth plate electrode, MS funnel with wire mesh, 20mm bore, Galvanised Iron pipe light grade, 1.50 metre long for watering and 40mm bore Galvanised Iron pipe light grade for earth lead protection 5.00 metre long fixed with poles with two clamps, made from earth lead strip 32mm x 6mm, bolts, nuts and washers, 80mm thick pre cast RCC cover 1:2:4, type B-1, reinforced with hard drawn steel wire fabric wieghing not less than 4 Kg/Sqm in lieu of CI cover etc including dismantling & taking out old unserviceable earthing complete all as specified & as directed. Note : (i) Excavation and earth work for drilling hole for electrode in any type of soil shall be included in this item. (ii) The unit rate shall be deemed to included for Test Point, 32mmx6mm GI strip from top of the earth plate upto 7.50m above ground level. In case, GI protection pipe required is less than 7.50m, no price adjustment shall be made. (iii) PCC Pit shall be provided at least 500mm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junctions, elbow etc shall be deemed to be included in the unit rate quoted by the tenderer.
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in soft/loose soil complete all as specified and as directed .
Excavation in trenches, n exc 1.5m wide and n exc 1.5m in depth , for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, laying of cables etc. n exc 10sqm on plan and n exc 1.5m in depth and getting out in hard /disintegrated soil/ rock complete all as specified and as directed .
Sand cushioning and cover (using local tibba sand), 80 mm thick before laying of cable and 150 mm thick after the cable is laid, complete all as specified and as directed by Engineer-in-Charge. (Note : 1. Approved local tibba dry sand after removal of vegetations, grass and other deleterious substances shall be used for sand cushioning and cover).
Jodhpur stone rough dressed slab, 40 mm to 50 mm thick, 25 cm to 35 cm wide of not less than 60 cm long dry abuttting each other for protection to under groung cable , complete all as specified and as directed .
Removing surplus soil to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed .
Returning, filling in approved soft/loose soil including spreading, leveling, watering and well ramming in layers each n.exc 25cm complete all as specified and as directed .
Supply, laying, jointing and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade cross sectional area 240 sq mm 3.5 core confirming to IS-7098 (Part-I-1988) laid in trenches, along poles through pipes etc. including taking out old unservicable cable complete all as specified. Notes :- (i) Sand cushioning, cable protection, GI pipe and excavation & earth work shall be measured & paid for separately (ii) Road cutting/ floor cutting/ cutting holes etc in walls required for laying/ fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.
80 mm bore GI tube, light grade galvanised with clamp of 25 x3 flat iron for protection of cable , with all fitting lead in trenches /under road / with wall /in wall /pole /under floor where required complete all as specified and as directed.
Drilling (Horizontally) of holes under road width 110 mm dia , pavement , hard standing by trench less technology ( manually ) with out disturbing the top surface of road (maximum 10 mtr wide) for laying of cable/ GI pipes complete all as specified and as directed .
Polypropylene random copolymer concealed (PPR) Pipes, 3 Layer, UV stabilised having thermal stability upto 93 degree centrigrade complete and fixed with the pole by providing Flat Iron clamps, nuts and bolts of size 25x25x3mm with nuts & bolts for protection of connecting wires, connection from Junction box to light fittings complete for outer dia 20mm (PN-16), including taking up or down old unserviceable pipe complete all as specified and directed.
Supply, laying, jointing and testing 1100 volts grade heavy duty cable PVC insulated aluminium solid conductor cable 10 sqmm, twin core, served with inner sheathing of PVC tape and overall PVC sheathed drawn through in and including suitable size non metallic PVC rigid conduit of suitable size including taking down old unserviceable cable complete all as specified and directed.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 630 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom with angle iron legs 04 Nos of size 75x75x6mm of length 0.90 mtr and embbded in PCC. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complete and including the followings : CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges. CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables
INCOMING :- MCCB 400 Amps, 4 pole, 415 volts, 50 kA, 50 Hz, , thermal magnetic release, adjustable type 70% to 100% -01 Nos (b) On load change over 400 Amps, 4 pole, 415 volts, 50 Hz, -01 Nos OUTGOING : (a) MCCB 250 Amps, 4 pole, 415 volts, 35/36 KA, 50 Hz, thermal magnetic release, Adjustable type 70 % to 100% - 02 Nos (b) MCCB 200 Amps, 4 pole, 415 volts, 25 KA, 50 Hz, thermal magnetic release, Iadjustable type 70% to 100% - 02 Nos (c ) MCCB 160 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, adjustable type 70 % to 100% - 01 Nos (d) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos (e) Digital Ammeter 96mm x 96mm suitable to read 0 to 630 Amps, accuracy class 1% - 01 Nos (f) Current transformer (CT) of rating 400/5, tape wound, rated burden 5 VA - 03 Nos (g) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (h) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (j) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.(k) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (l) Danger Notice Plate -02 Nos (m) Power contactor four pole with coil voltage 230 volt of capacity 63 Amps 50 cycles. Of Make - Legrand, ABB, L&T - 01 Nos (n) Time switch microrex analog time switch Cat part No 412814 of Legrand -01 Nos (o) Panel box made up of CRCA mild steel 3.15mm thick, duly powder coated with bus bar and internal wiring all as per CPRI approved (The panel shall not be less than 1.50 Sqm front area) 'Note : Panel will be manufactured by CPRI approved firm . The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instructions of manufacturer and rate of foundation shall be deemed to be included in the quoted rates.
Disconnecting, dismantling of existing old unserviceable LT Panel/Feeder pillar box and Design, supply, erection, commissioning and testing of outdoor type LT Panel, platform mounted, suitable for 3 phase 4 wire, 415 volts AC supply and having 4 Nos stepped type main copper bus bars of 250 Amps, looping & branch connection system shall be made with suitable rating copper bus bar having sleeves of colour coded .The chamber shall be painted with powder coated paint (Shade : RAL-7032) after 9 tank pre-treatment of surfaces. The LT Panel shall be provided with suitable Neoprene rubber gasket to make it completely dust and vermin proof and degree of protection not less than IP-55 and general construction conforming to IS : 13947. The LT Panel shall be made out of 3.15mm thick CRCA mild steel sheet and 3.00mm thick gland plate , front door (02 layers) and rear Door (01 layer) opening facility and 4 side slanting canopy type roof on top and mild steel channel (75 MC) base frame at bottom with angle iron legs 04 Nos of size 75x75x6mm of length 0.90 mtr and embbded in PCC. All incoming MCCBs shall be marked with location and rating of MCCBs. The Feeder Pillar shall be provided with ventilation facility in the form of louvers for better heat dissipation in and including dismantling of old unserviceable LT Panel complere and including the followings :CONTROL WIRING : All control wirings shall have to be carried out with 1100 volts rated FR grade PVC insulated multi-flexible type copper wire of cross sectional area 1.50Sqmm and shall be properly bunched, tied and dressed, ferrule marked for proper identification and crimped with suitable size and type of tinned copper lugs and shall be wrapped with PVC spring type tube near the door hinges.CABLE ALLEY- Cable alley shall be provided in both side of the panel of suitable space for all incoming and outgoing cables. Cable terminals shall be provided for conecting of all incoming and outgoing cables . INCOMING :- MCCB 160 Amps, 4 pole, 415 volts, 25 kA, 50 Hz, , thermal magnetic release, adjustable type 70% to 100% -01 Nos OUTGOING : (a) MCCB 100 Amps, 4 pole, 415 volts, 16 KA, 50 Hz, thermal magnetic release, Adjustable type 70 % to 100% - 02 Nos (b) Digital volt meter 96mm x 96mm suitable to read 0 to 500 volts, accuracy class 1% - 01 Nos
(c) Digital Ammeter 96mm x 96mm suitable to read 0 to 160 Amps, accuracy class 1% - 01 Nos (d) Current transformer (CT) of rating 160/5, tape wound, rated burden 5 VA - 03 Nos (e) LED indicator lamps complete with integral circuit and cluster LED, suitable to operate in 230-240 Volts AC supply - 1set of 03 Nos (Red - 01, Yellow- 01, Blue - 01) (f) Control fuse holder, made of bakellite, 16 Amps rating, stud type, pannel door mounting complete with 01 No 02 Amps HRC fuse of suitable type- 03 Nos (g) Copper bus bar 20mm wide,5mm thick, of suitable length duly mounted on FRP bus bar insulators and marked with standard colour coded sleeves / tapes for all outgoing MCCBs - 04 Nos.(h) LED Pilot Lamp of following colours : (i) RED - 01 No, YELLOW - 01 No, BLUE - 01 No. (j) Danger Notice Plate -02 Nos (k) Pannel box made up of CRCA mild steel 3.15mm thick, duly powder coated with busbar and internal wiring all as per CPRI approved (The panel shall not be less than 1.0 Sqm front area) Note : Panel will be manufactured by CPRI approved firm as indicated above. The contractor shall submit drawing of the panels to Engr-in-charge before procurement of LT panel for approval alongwith CPRI approval. Foundation will prepared as per instructions of manufacturer and rate of fondation shall be deemed to be included in the quoted rates.
MS Cross arms, bracings, supports, clamp and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot drilling holes for bolts in any type, shape or as indicated and directed inclusive of one coat of red oxide primer and two coat of aluminium paint including taking down existing complete all as specified and directed .
Excavation in post holes(or similar holes) each n. exc 0.5 cum getting out ,returning filling in and ramming earth or broken rubble mixed with around in layer n.exc.25 cm thick, watering and removing surplus soil to a distance n. exc 50 m and making good surface all complete all as specified and as directed .
Plain cement concrete (1:2:4) type B-1 (using 20mm graded stone aggregate) in lintel, cill, bed block coping ,bed plate, bond stone etc including weathering slightly rounded or chamfered angles and throating and necessary form work complete all as specified and directed .
Supply and fix junction box made out of polycarbonate with IP 55/IP 65 protection of size not less than 200 x 160 x 98 mm , 5 way having terminals for termination of cable with necessary nuts and bolts including -02 Nos polycarbonate cable gland, 01 Nos DIN rail for mounting of MCB and 01 No, MCB SP, 10 KA, 6 Amps in and including fixing clamp of FI 25 x 3mm with necessary nuts and bolts in and including taking down of old junction box of any type and size complete all as specified and directed.
PVC elastomer insulated and fire retardant PVC sheathed, round or flat cable size 1.5 sqmm, 3 core multicore, industrial flexible cable with bright annealed, copper conductor, 1100 volts grade confirming to IS-694-1990 including taking down old unserviceable cable complete all as specified and directed.
prem enterprises
SANJOLI CONSTRUCTION COMPANY
S.D. And Company
M/s Shree Construction Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .